Effect of Gamma Irradiation on Anti Nutritional Factors and Nutritional Value of Canola Meal for Broiler Chickens

  • Gharaghani, Hossein;Zaghari, Mojtaba;Shahhosseini, Gholamreza;Moravej, Hossein
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.21 no.10
    • /
    • pp.1479-1485
    • /
    • 2008
  • Two completely randomized block design experiments were conducted to evaluate the effect of gamma irradiation processing of canola meal on performance parameters of broiler chicks (Ross 308) and protein quality of canola meal. Protein efficiency ratio (PER) and net protein ratio (NPR) were measured as indices of canola meal protein quality. Samples of canola meal were tested for nutritional value after being irradiated at dose levels 10, 20 and 30 kGy. Glucosinolate content was reduced 40, 70 and 89 percent at irradiation dose levels of 10, 20 and 30 kGy respectively (p<0.01). Percent of erucic acid in total fatty acid content increased 44, 58 and 48% as a function of radiation dose (p<0.01). Dose levels did not affect feed conversion ratio (FCR) and body weight gain of chicks (p>0.05). Liver weight was decreased by irradiation dose (p<0.05). The same trend was observed for kidney weights, but this trend was not significant (p>0.05). Gamma irradiation processing of canola meal had no significant effect on $T_3$ level in blood of chickens that consumed canola meal, but $T_4$ level of chicken blood at the 30 kGy dose decreased significantly (p<0.05). PER and NPR were not affected by radiation dose level (p>0.05). Gamma irradiation seems to be a good procedure to improve the nutritional quality of canola meal.

Factors associated with pulmonary toxicity after myeloablative conditioning using fractionated total body irradiation

  • Byun, Hwa Kyung;Yoon, Hong In;Cho, Jaeho;Kim, Hyun Ju;Min, Yoo Hong;Lyu, Chuhl Joo;Cheong, June-Won;Kim, Jin Seok;Kim, Hyo Sun;Kim, Soo-Jeong;Yang, Andrew Jihoon;Lee, Byung Min;Lee, Won Hee;Lee, Joongyo;Ahn, Ki Jung;Suh, Chang-Ok
    • Radiation Oncology Journal
    • /
    • v.35 no.3
    • /
    • pp.257-267
    • /
    • 2017
  • Purpose: Pulmonary toxicities, including infectious pneumonia (IP) and idiopathic pneumonia syndrome (IPS), are serious side effects of total body irradiation (TBI) used for myeloablative conditioning. This study aimed to evaluate clinical factors associated with IP and IPS following TBI. Materials and Methods: Fifty-eight patients with hematologic malignancies who underwent TBI before allogeneic hematopoietic stem cell transplantation between 2005 and 2014 were reviewed. Most patients (91%) received 12 Gy in 1.5 Gy fractions twice a day. Pulmonary toxicities were diagnosed based on either radiographic evidence or reduced pulmonary function, and were subdivided into IP and IPS based on the presence or absence of concurrent infection. Results: Pulmonary toxicities developed in 36 patients (62%); 16 (28%) had IP and 20 (34%) had IPS. IP was significantly associated with increased treatment-related mortality (p = 0.028) and decreased survival (p = 0.039). Multivariate analysis revealed that the risk of developing IPS was significantly higher in patients who received stem cells from a matched unrelated donor than from a matched sibling donor (p = 0.021; hazard ratio [HR] = 12.67; 95% confidence interval [CI], 1.46-110.30). Combining other conditioning agents with cyclophosphamide produced a higher tendency to develop IP (p = 0.064; HR = 6.19; 95% CI, 0.90-42.56). Conclusion: IP and IPS involve different risk factors and distinct pathogeneses that should be considered when planning treatments before and after TBI.

Effects of total body irradiation-based conditioning on allogeneic stem cell transplantation for pediatric acute leukemia: a single-institution study

  • Park, Jongmoo;Choi, Eun Kyung;Kim, Jong Hoon;Lee, Sang-Wook;Song, Si Yeol;Yoon, Sang Min;Kim, Young Seok;Kim, Su Ssan;Park, Jin-Hong;Park, Jaehyeon;Ahn, Seung Do
    • Radiation Oncology Journal
    • /
    • v.32 no.3
    • /
    • pp.198-207
    • /
    • 2014
  • Purpose: To evaluate the effects of total body irradiation (TBI), as a conditioning regimen prior to allogeneic stem cell transplantation (allo-SCT), in pediatric acute leukemia patients. Materials and Methods: From January 2001 to December 2011, 28 patients, aged less than 18 years, were treated with TBI-based conditioning for allo-SCT in our institution. Of the 28 patients, 21 patients were diagnosed with acute lymphoblastic leukemia (ALL, 75%) and 7 were diagnosed with acute myeloid leukemia (AML, 25%). TBI was completed 4 days or 1 day before stem cell infusion. Patients underwent radiation therapy with bilateral parallel opposing fields and 6-MV X-rays. The Kaplan-Meier method was used to calculate survival outcomes. Results: The 2-year event-free survival and overall survival rates were 66% and 56%, respectively (71.4% and 60.0% in AML patients vs. 64.3% and 52.4% in ALL patients, respectively). Treatment related mortality rate were 25%. Acute and chronic graft-versus-host disease was a major complication; other complications included endocrine dysfunction and pulmonary complications. Common complications from TBI were nausea (89%) and cataracts (7.1%). Conclusion: The efficacy and toxicity data in this study of TBI-based conditioning to pediatric acute leukemia patients were comparable with previous studies. However, clinicians need to focus on the acute and chronic complications related to allo-SCT.

Total Body Irradiation for MyastHenia Gravis with Thvmoma - Case Report - (흉선종을 동반한 중증근무력증 환자에서 전신 방사선치료)

  • Kang, Ki-Mun;Choi, Ihl-Bohng;Kim, In-Ah
    • Radiation Oncology Journal
    • /
    • v.17 no.2
    • /
    • pp.146-150
    • /
    • 1999
  • Myasthenia gravis (MG) is relatively rare ouuring as one of important autoimmune disease to affect neuromuscular junction. This study was clinically to evaluate total body irradiation (TBI) against two patients including 33-year and 39-year females for chronic MG with thymoma who hospitalized in the St. Mary's Hospital, Catholic University since 1994 as well as who showed no response by thymectomy, immunotherapy and hormonal therapy. TBI designed by the dose of 150$\~$180 cGy consisting of 10 cGy per fraction, three times a week, for 5~e weeks using linear accelerator of 6 MV. During the treatment of TBI, they did complain acute side effect such as vomiting and also appear improved physical condition from 4$\~$6 weeks after TBI. Through the follow-up period of 18 or 42 months after TBI, they did not have any symptomatic recurrence. Consequently, the results suggest that TBI can be used as an alternative tool for the patients concurrently for MG with thymoma who had been refractory to various conventional therapies like thymectomy, immunotherapy and hormonal therapy.

  • PDF

The Dosimetric Data of 10 MV Linear Accelerator Photon Beam for Total Body Irradiation (전신 방사선조사를 위한 10MV 선형가속기의 선량측정)

  • Ahn Sung Ja;Kang Wee-Saing;Park Seung Jin;Nam Taek Keun;Chung Woong Ki;Nah Byung Sik
    • Radiation Oncology Journal
    • /
    • v.12 no.2
    • /
    • pp.225-232
    • /
    • 1994
  • Purpose : This study was to obtain the basic dosimetric data using the 10 MV X-ray for the total body irradiation. Materials and Methods : A linear accelerator photon beam is planned to be used as a radiation source for total body irradiation (TBI) in Chonnam University Hospital. The planned distance from the target to the midplane of a patient is 360cm and the maximum geometric field size is 144cm x 144cm. Polystyrene phantom sized $30{\times}30{\times}30.2cm^3$ and consisted of several sheets with various thickness, and a parallel plate ionization chamber were used to measure surface dose and percent depth dose (PDD) at 345cm SSD, and dose profiles. To evaluate whether a beam modifier is necessary for TBI, dosimetry in build up region was made first with no modifier and next with an 1cm thick acryl plate 20cm far from the polystyrene phantom surface. For a fixed sourec-chamber distance, output factors were measured for various depth. Results : As any beam modifier was not on the way of radiation of 10MV X-ray, the $d_{max}$ and surface dose was 1.8cm and $61\%$, respectively, for 345cm SSD. When an 1cm thick acryl plate was put 20cm far from polystyrene phantom for the SSD, the $d_{max}$ and surface dose were 0.8cm and $94\%$, respectively. With acryl as a beam spoiler, the PDD at 10cm depth was $78.4\%$ and exit dose was a little higher than expected dose at interface of exit surface. For two-opposing fields for a 30cm phantom thick phantom, the surface dose and maximum dose relative to mid-depth dose in our experiments were $102.5\%$ and $106.3\%$, respectively. The off-axis distance of that point of $95\%$ of beam axis dose were 70cm on principal axis and 80cm on diagonal axis. Conclusion: 1. To increase surface dose for TBI by 10MV X-ray at 360cm SAD, 1cm thick acrylic spoiler was sufficient when distance from phantom surface to spoiler was 20cm. 2. At 345cm SSD, 10MV X-ray beam of full field produced a satisfiable dose uniformity for TBI within $7\%$ in the phantom of 30cm thickness by two-opposing irradiation technique. 3. The uniform dose distribution region was 67cm on principal axis of the beam and 80cm on diagonal axis from beam axis. 4. The output factors at mid-point of various thickness revealed linear relation with depth, and it could be applicable to practical TBI.

  • PDF

Study on Development of Acute Index Through Peripheral Blood Test in Total Body Irradiation Patients (방사선 전신조사 환자의 말초혈액 검사를 통한 급성장애 지표개발에 관한 연구)

  • Park, Young-Hwan
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.13 no.1
    • /
    • pp.91-103
    • /
    • 2001
  • In those patients who underwent radiation therapy with 10 MV X-ray for bone marrow transfer, compared the effect of high dose irradiation on peripheral blood were investigated in randomly selecting 18 patients. thus, changes in the levels of peripheral blood (WBC, Seg. neutrophil, Lymphocyte, RBC, Hemoglobin, Hematocrit ratio, GOT, GPT) were observed for 25 days after irradiation with the peripheral blood levels before irradiation in these patients and in 32 controls. Among changes in peripheral blood, the level of WBC was $8.63\%$ after radiation therapy with as much decrease as $0.22{\times}103{\pm}0.19{\times}103/mm^3$ compared with $2.51{\times}103{\pm}1.29{\times}103/mm^3$ before radiation therapy, and was only $6.35\%$ of $7.17{\times}103/mm^3{\pm}1.46{\times}103/mm^3$ in the controls, showing statistical significance (P<0.01, r2=0.9151). In the morphologic test of WBC, the level of Seg. neutrophil was decreased as much as to $20.53\%$ with $14.17{\pm}21.60\%$ compared with $69.00{\pm}25.60\%$ before irradiation, and decreased down to $24.39\%$ compared with $58.09{\pm}7.62\%$ in the controls (P<0.05, r2=0.6316). The number of lymphocyte increased as much as 3.94 folds at $79.91{\pm}27.30\%$ compared with $20.29{\pm}21.15\%$ before irradiation and was 2.39 times higher than $33.46{\pm}6.79\%$ in the controls (P<0.05, r2=0.7337). Although the change in the number of RBC was little with $3.18{\times}106{\pm}0.41{\times}106/mm^3$ before irradiation and $4.66{\times}106{\pm}0.43{\times}106/mm^3$ in the controls, no statistical significance was present (P>0.05). In addition, The number of hemoglobin was low compared with before irradiation and with the controls, but none showed statistical significance (P>0.05). Similarly, although the hematocrit ratio was low compared with before irradiation and with the controls, no statistical significance was present (P>0.05). In the values of the histologic examinations GOT and GPT, there is statistical significance between those from with before irradiation and with the controls (P<0.05). Thus, among peripheral blood, the number of WBC decreased drastically for a certain period after total body irradiation with high dose radiation, and the levels of Seg. neutriphil and lymphocyte decreased significantly after irradiation in the lymphocyte morphologic test. The results of the present study suggest that the possibility of developing the first to determine initially those patients who might develop radiation acute impairment using the usual peripheral blood test of patients to be exposed to high dose irradiation.

  • PDF

THE EFFECT OF LOW DIETARY CALCIUM AND IRRADIATION ON MANDIBLE IN RATS (저칼슘식이와 방사선조사가 백서 악골에 미치는 영향의 실험적 연구)

  • Lee Sun-Ki;Lee Sang-Rae
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.23 no.2
    • /
    • pp.229-250
    • /
    • 1993
  • This study was performed to investigate the morphological and structural changes of bone tissues and the effects of irradiation on the mandibular bodies of rats which were fed low calcium diets. In order to carry out this experiment, 160 seven-week old Sprague-Dawley strain rats weighing about 150 gm were selected and equally divided into one normal diet group of 80 rats and one low calcium diet group with the remainder. These groups were then subdivided into two groups, 40 were assigned rats for each subdivided group, exposed to radiation. The Group 1 was composed of forty non-irradiated rats with normal diet, Group 2 of forty irradiated rats with normal diet, Group 3 forty non-irradiated rats with low calcium diet, and Group 4 forty irradiated rats with low calcium diet. The two irradiation groups received a single dose of 20 Gy on the jaw area only and irradiated with a cobalt-50 teletherapy unit. The rats with normal and low calcium diet groups were serially terminated by ten on the 3rd, the 7th, the 14th, and the 21st day after irradiation. After termination, both sides of the dead rats mandible were removed and fixed with 10% neutral formalin. The bone density of mandibular body was measured by use of bone mineral densitometer(Model DPX -alpha, Lunar Corp., U.SA). Triga Mark ill nuclear reactor in Korea Atomic Research Institute was used for neutron activation and then calcium contents of mandibular body were measured by using a 4096 multichannel analyzer (EG and G ORTEC 919 MCA, U.SA). Also the mandibular body was radiographed with a soft X-ray apparatus(Hitex Co., Ltd., Japan). Thereafter, the obtained microradiograms were observed by a light microscope and were used for the morphometric analysis using a image analyzer(Leco 2001 System, Leco Co., Canada). The morphometric analysis was performed for parameters such as the total area, the bone area, the inner and outer perimeters of the bone. The obtained results were as follows: 1. In the morphometric analysis, total area and outer perimeter of the mandibular bodies of Group 3 were a little smaller than that of Group 1. The mean bone width and bone area were much smaller than that of Group 1 and the inner perimeter of Group 3 was much longer than that of Group 1. The total area and outer perimeter of Group 2 and Group 4 showed little difference. The mean bone width and bone area of Group 4 were smaller than that of Group 2 and the inner perimeter of Group 4 was longer than that of Group 2. 2. The remarkable decreases of the number and thickness of trabeculae and also the resorption of endosteal surface of cortical bone could be seen in the microradiogram of Group 3, Group 4 since the 3rd day of experiment. On the 21st day of experiment, the above findings could be more clearly seen in Group 4 than in Group 3. 3. The bone mineral density of Group 3 was lesser than that of Group 1 and the bone mineral density of Group 4 was lesser than that of Group 2 on the 7th, 14th, 21st days. The irradiation caused the bone mineral density to be decreased regardless of diet. In the case of Groups with low calcium diet, the bone mineral density was much decreased on the 21st day than on the 3rd day of experiment. 4. The calcium content in mandible of Group 3 was smaller than that of Group 1 throughout the experiment. roup 4 showed the least amount of calcium content. The irradiation caused the calcium content to be decreased regardless of diet. In the case of Groups with low calcium diet, the calcium content was much decreased on the 21st day than on the 3rd day of experiment. In conclusion, the present study demonstrated that morphological changs and decrease of bone mass due to resorption of bone by low calcium diet, and that the resorption of bone could be found in the spongeous bone and endosteal surface of cortical bone. So the problem of resorption of bone must be considered when the old and the postmenopausal women are taken radiotherapy because the irradiation seems to be accelerated the resorption of osteoporotic bone.

  • PDF

Effect of Whole Body Irradiation on Spontaneous Motility and Oxygen Consumption Rate of Mouse Isolated Duodenum and Its Response to Glucose and 5-hydrocytryptamine (X-선(線) 전신조사(全身照射)가 적출(摘出)마우스 십이지장(十二指腸)의 자동성운동(自動性運動) 및 산소(酸素) 소비량(消費量)에 미치는 영향(影響)과 Glucose 및 5-hydroxytryptamine 이 이들에 미치는 효과(效果))

  • Kwon, Yong-Ju;Choo, Young-Eun
    • The Korean Journal of Physiology
    • /
    • v.4 no.2
    • /
    • pp.45-51
    • /
    • 1970
  • In an attempt to better understand the effect of whole body irradiation on the spontaneous motility and oxygen consumption rate of the isolated mouse duodenum, a whole body X-irradiation of 1,000r. was given to albino mouse, and 1) the total length of contraction of isolated duodenum was recorded on kymograph every five minutes for 60 minutes, 2) glucose and 5-hydroxytryptamine(5-HT) were added to the reaction medium of Kreb's-Ringer-bicarbonate buffer(KRB) and response of the isolated duodenum to the drugs was observed, and 3) the oxygen consumption rate $(QO_2)$ of the isolated duodenum as well as the effect of glucose and 5-HT on $QO_2$ were measured by Warburg's standard manometric method and the comparison was made with the control(i.e. normal) group. The results thus obtained are summarized as follows. 1. The spontaneous motility of the isolated duodenum in the irradiated groups showed a significantly elevated pattern for the first 15 minutes comparing with the control. The motility, however, decreased after 15 minutes and remained so in the irradiated groups to the level of the nonirradiated control, but 24 hours post-irradiation group showed a tendency of an increased motility while one hour post-irradiation group showed no difference comparing with the control. 2. Addition of glucose produced generally elevated motility of the isolated duodenum in both irradiated and non-irradiated groups comparing with the control throughout the experiment, but no difference was observed in contractile amplitude between the irradiated and non·irradiated groups. 3. When 5-HT was added to the irradiated group, the contractile amplitude of isolated duodenum was similar to that of the control, and 5-HT alone caused a slight increase of the motility comparing with the control. 4. The oxygen consumption rate $(QO_2)$ of the isolated duodenum was found to be ,slightly increased in one hour post·irradiated group, but similar in 24 hour post·irradiated group comparing with the control. Glucose produced a significant increase of $QO_2$ in all the groups, but 5-HT produced a tendency of decrease of $QO_2$ in all the groups.

  • PDF

Dose Distribution of Rectum and Bladder in Intracavitary Irradiation (자궁경부암 강내 방사선 조사장치에 의한 직장 및 방광의 피폭선량 평가)

  • Chu S. S.;Oh W. Y.;Suh C. O.;Kim G. E.
    • Radiation Oncology Journal
    • /
    • v.2 no.2
    • /
    • pp.261-270
    • /
    • 1984
  • The intrauterine irradiation is essential to achieve adequate tumor dose to central tumor mass of uterine malignancy in radiotherapy. The complications of pelvic organ are known to be directly related to radiation dose and physical parameters. The simulation radiation and medical records of 203 patients who were treated with intrauterine irradiation from Feb. 1983 to Oct. 1983, were critically analized. The physical parameters to include distances between lateral walls of vaginal fornices, longitudinal and lateral angles of tandem applicator to the body axis, the distance from the external os of uterine cervix to the central axis of ovoids were measured for low dose rate irradiation system and high dose rate remote control afterloading system. The radiation doses and dose distributions within cervical area including interesting points and bladder, rectum, according to sources arrangement and location of applicator, were estimated with personal computer. Followings were summary of study results ; 1. In distances between lateral walls of vaginal fornices, the low dose rate system showed as $4\~7cm$ width and high dose rate system showed as $5\~6cm$. 2. In horizontal angulation of tandem to body axis, the low dose rate system revealed mid position$64.6\%$, left deviation $19.2\%$and right deviation $16.2\%$. 3. In longitudinal angulation of tandem to body axis, the mid position was $11.8\%$ and anterior angulation $88.2\%$ in low dose rate system but in high dose rate system, anterior angulation was $98.5\%$. 4. Down ward displacement of ovoids below external os was only $3\%$ in low dose rate system and $66.7\%$ in high dose rate system. 5. In radiation source arrangement, the most activities of tandem and ovoid were 35 by 30 in low dose rate system but 50 by 40 in high dose rate system. 6. In low and high dose rate system, the total doses an4 TDF were 50, 70 Gy and 141, 123, including 40 Gy external irradiation. 7. The doses and TDF in interesting points Co, B, were 93, 47 Gy and 230, 73 in high dose rate system but in low doss rate system, 123, 52 Gy and 262, 75 respectively. 8. Doses and TDF in bladder and rectum were 70, 68 Gy and 124, 120 in low dose rate system, but in high dose rate system, 58, 64 Gy 98, 110 respectively, and then grades of injuries in bladder and rectum were 25, $30\%$ and 18, $23\%$ respectively.

  • PDF

The Relative Biological Effectiveness of KCCH-Cyclotron neutron (원자력병원(原子力病院) 싸이클로트론 속중성자선(速中性子線)의 방사선생물학적효과비(RBE)에 관(關)한 연구(硏究))

  • Yoo, Seong-Yul;Koh, Kyoung-Hwan;Cho, Chul-Koo;Kim, Sung-Ho
    • Journal of Radiation Protection and Research
    • /
    • v.12 no.2
    • /
    • pp.1-8
    • /
    • 1987
  • The relative biological effectiveness has been measured for the biological characterization of $p^+(50.5\;MeV)$ Be neutron of KCCH-Cyclotron prior to clinical application. Measured RBE of mouse jejunal crypt cell in single whole body irradiation was 2.8. This RBE value is changed differently in different biologic systems such as mouse jejunal crypt cells, intestine and bone marrow in different irradiation method, so that in fractionated irradiation RBE is variable to the different fraction size and total dose, and also variable to the number of fractions.

  • PDF