• 제목/요약/키워드: torsional design

검색결과 533건 처리시간 0.025초

비대칭 벽식구조의 최적 비틀림 설계 (An optimized torsional design of asymmetric wall structures)

  • 조봉호;홍성걸
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 2002년도 춘계 학술발표회 논문집
    • /
    • pp.327-334
    • /
    • 2002
  • This paper develops an optimized torsional design method of asymmetric wall structures considering deformation capacities of walls. Contrary to the current torsional provisions, a deformation based torsional design is based on the assumption that stiffness and strength are dependent. Current torsional provisions specify two design eccentricity of stiffness to calculate the design forces of members. But such a methodology leads to an excessive over-strength of some members and an optimal torsional behavior is not ensured. Deformation-based torsional design uses displacement and rotation angle as design parameters and calculates base shear for inelastic torsional response directly. Because optimal torsional behavior can be defined based on the deformation of members, deformation based torsional design procedure can be applied to the optimal and performance-based torsional design. To consider the effect of accidental eccentricity, an over-strength factor is defined. The over-strength factor is determined from performance level, torsional resistance and arrangement of walls.

  • PDF

변형에 기초한 비대칭 벽식 주초의 내진설계 (Deformation Based Seismic Design of Asymmetric Wall Structures)

  • 홍성걸;조봉호
    • 한국지진공학회논문집
    • /
    • 제6권1호
    • /
    • pp.43-53
    • /
    • 2002
  • 기존의 비틀림 설계법은 구조 벽체의 강성은 강도에 무관하게 결정된다는 기본 가정하에 강성을 설계 변수로 비대칭 벽식 구조의 비틀림 효과를 최소화 하기 위한 각 부재의 강도를 결정한다. 이와는 달리 최근의 연구에 의하면 구조 벽체의 강성과 강도는 상호 연관성을 갖는 것으로 알려졌다. 이 경우 벽체의 실제 강성은 비틀림설계를 모두 마친 후에야 결정되므로 강성에 기초하여 비틀림 설계를 수행한다는 것은 모순이다. 이와 같은 문제점을 해결하기 위해 본 논문은 강성이 아닌 변형에 기초한 비대칭 벽식 구조의 비틀림 설계법을 제안한다. 기존의 비틀림 설계법은 탄성 비틀림 응답과 반응수정계수를 이용하여 비탄성 응답에 대한 설계 하중을 간접적으로 계산하지만 변형에 기초한 비틀림 설계법은 변위와 비틀림 회전각을 설계 변수로 비탄성 응답에 대한 설계 하중을 직접적으로 계산한다. 기존의 비틀림 설계법이 비틀림 효과를 최소화하는 것을 목적으로 하는 데 비하여, 변형에 기초한 비틀림 설계법은 내진역량설계법의 기본 개념에 의거하여 설계자가 의도한 비틀림 미케니즘을 발휘하는 데 그 목적을 둔다. 변위와 회전각은 비대칭 구조의 성능수준을 직접적으로 나타내는 성능 지표이므로 본 설계법은 성능기초 내진설계에 효과적으로 사용될 수 있다.

Thickness of shear flow path in RC beams at maximum torsional strength

  • Kim, Hyeong-Gook;Lee, Jung-Yoon;Kim, Kil-Hee
    • Computers and Concrete
    • /
    • 제29권 5호
    • /
    • pp.303-321
    • /
    • 2022
  • The current design equations for predicting the torsional capacity of RC members underestimate the torsional strength of under-reinforced members and overestimate the torsional strength of over-reinforced members. This is because the design equations consider only the yield strength of torsional reinforcement and the cross-sectional properties of members in determining the torsional capacity. This paper presents an analytical model to predict the thickness of shear flow path in RC beams subjected to pure torsion. The analytical model assumes that torsional reinforcement resists torsional moment with a sufficient deformation capacity until concrete fails by crushing. The ACI 318 code is modified by applying analytical results from the proposed model such as the average stress of torsional reinforcement and the effective gross area enclosed by the shear flow path. Comparison of the calculated and observed torsional strengths of existing 129 test beams showed good agreement. Two design variables related to the compressive strength of concrete in the proposed model are approximated for design application. The accuracy of the ACI 318 code for the over-reinforced test beams improved somewhat with the use of the approximations for the average stresses of reinforcements and the effective gross area enclosed by the shear flow path.

콘크리트의 비틀림강도를 포함한 RC보의 공칭비틀림강도 (Nominal Torsional Moment Strength of RC Beam with Torsional Moment Strength of Concrete)

  • 박창규
    • 한국농공학회지
    • /
    • 제44권3호
    • /
    • pp.73-84
    • /
    • 2002
  • Nominal shear strength of concrete beam is the combined strength of concrete shear strength and steel shear strength in current design code. But Torsional moment strength of concrete is neglected in calculation of the nominal torsional moment strength of reinforced concrete beam in current revised code. Tensile stress of concrete strut between cracks is still in effect due to tension stiffening effect. But the tensile stresses of concrete after cracking are neglected in bending and torsion in design. The torsional behavior is similar to the shear behavior in mechanics. Therefore the torsional moment strength of concrete should be concluded to the nominal torsional moment strength of reinforced concrete beam. To verify the validity of the proposed model, the nominal torsional moment strengths according to CEB, two ACI codes(89, 99) and proposed model are compared to experimental torsional strengths of 55 test specimens found in literature. The nominal torsional moment strengths by the proposed model show the best results.

Flexural-torsional buckling tests of cold-formed steel compression members at elevated temperatures

  • Heva, Yasintha Bandula;Mahendran, Mahen
    • Steel and Composite Structures
    • /
    • 제14권3호
    • /
    • pp.205-227
    • /
    • 2013
  • Current design standards do not provide adequate guidelines for the fire design of cold-formed steel compression members subject to flexural-torsional buckling. Eurocode 3 Part 1.2 (2005) recommends the same fire design guidelines for both hot-rolled and cold-formed steel compression members subject to flexural-torsional buckling although considerable behavioural differences exist between cold-formed and hot-rolled steel members. Past research has recommended the use of ambient temperature cold-formed steel design rules for the fire design of cold-formed steel compression members provided appropriately reduced mechanical properties are used at elevated temperatures. To assess the accuracy of flexural-torsional buckling design rules in both ambient temperature cold-formed steel design and fire design standards, an experimental study of slender cold-formed steel compression members was undertaken at both ambient and elevated temperatures. This paper presents the details of this experimental study, its results, and their comparison with the predictions from the current design rules. It was found that the current ambient temperature design rules are conservative while the fire design rules are overly conservative. Suitable recommendations have been made in relation to the currently available design rules for flexural-torsional buckling including methods of improvement. Most importantly, this paper has addressed the lack of experimental results for slender cold-formed steel columns at elevated temperatures.

주행시 비틀림진동 저감을 위한 클러치 비틀림특성 연구 (A Study on Clutch Torsional Characteristics for the Torsional Vibration Reduction at Driving)

  • 정태진;홍동표;태신호;윤영진;김상수
    • 소음진동
    • /
    • 제5권1호
    • /
    • pp.75-83
    • /
    • 1995
  • The fluctuation of the engine torque appears to be the major source of the torsional vibration of the automotive driveline. The reduction of this torsional vibration has become a significant problem, due to an increase in the fluctuation of the torque of recent light weighted and high powered engines, along with the requirements of higher performance. The torsional vibration of the automotive driveline can be reduced by smoothing the fluctuation by adjusting the torsional characteristics of the clutch-disc. This paper presents an experimental and theoretical research on the clutch-disc torsional characteristics for the reduction of the torsional vibration at driving. The effects of clutch-damper on diminishing the torsional vibration were investigated experimentally. A dynamic model for the automotive driveline was developed, and the engine torque of the model were evaluated with experimental data. By executing a simulation using the model, it has become possible to obtain the clutch-disc torsional characteristics and the clutch-disc torsional characteristics for reducing the torsional vibration has been suggested. The results are as follows: (1) By exceuting simulations using nonlinear model of four degrees of freedom, a design technique to determine the clutch-disc torsional characteristics for reducing the torsional vibration at driving was developed. (2) The influence of barious torsional characteristics of the clutch has been studied in examining design parameters, which indicates that the domain to minimize the torsional vibration at driving depends on the characteristics of the clutch-damper, i. e., spring constant and hysteresis.

  • PDF

전단과 비틀림모멘트 설계의 조합 (Combined Design Method for Shear and Torsional Moment)

  • 민창식
    • 콘크리트학회논문집
    • /
    • 제23권1호
    • /
    • pp.57-65
    • /
    • 2011
  • 전단과 비틀림모멘트가 동시에 작용하는 경우에 단면에는 각각의 영향으로 인하여 전단응력이 발생하므로 이 두 응력을 더하여 설계할 수 있다. 그러나 현행 콘크리트구조설계기준에서는 전단과 비틀림모멘트 설계식을 단위가 서로 틀린 단면력으로 표현하여 분포도를 그리기 위해서는 각각의 좌표에 분리해서 그려야만 한다. 만약에 이 두 하중으로 인한 단면력을 응력으로 표현하게 되면 두 전단응력을 더하여 하나의 좌표에 표현할 수 있고, 설계 결과도 동시에 그려 넣을 수 있으므로 쉽게 설계과정을 인식하여 실수를 최소화 할 수 있을 것이다. 게다가 현행 기준에서는 전단과 비틀림모멘트에 대한 설계식을 단위 길이 당 스터럽의 단면적으로 표현되는 $A_{\upsilon}/s$$2A_{\upsilon}/s$로 제시하여, 설계과정에서 이 값들의 크기나 상황을 정확하게 인식하기 거의 불가능하게 된다. 설계에서 먼저 스터럽의 종류를 결정하여 단면적 $A_{\upsilon}$$A_t$가 결정되므로 설계식들을 스터럽의 간격에 대한 식으로 정리하면 설계과정을 명확하게 인식할 수 있고 또한 여러 설계과정도 간단하게 정리되어 이해하기 쉽도록 할 것이다.

An experimental and numerical investigation on the effect of longitudinal reinforcements in torsional resistance of RC beams

  • Khagehhosseini, A.H.;Porhosseini, R.;Morshed, R.;Eslami, A.
    • Structural Engineering and Mechanics
    • /
    • 제47권2호
    • /
    • pp.247-263
    • /
    • 2013
  • It is evident that torsional resistance of a reinforced concrete (RC) member is attributed to both concrete and steel reinforcement. However, recent structural design codes neglect the contribution of concrete because of cracking. This paper reports on the results of an experimental and numerical investigation into the torsional capacity of concrete beams reinforced only by longitudinal rebars without transverse reinforcement. The experimental investigation involves six specimens tested under pure torsion. Each specimen was made using a cast-in-place concrete with different amounts of longitudinal reinforcements. To create the torsional moment, an eccentric load was applied at the end of the beam whereas the other end was fixed against twist, vertical, and transverse displacement. The experimental results were also compared with the results obtained from the nonlinear finite element analysis performed in ANSYS. The outcomes showed a good agreement between experimental and numerical investigation, indicating the capability of numerical analysis in predicting the torsional capacity of RC beams. Both experimental and numerical results showed a considerable torsional post-cracking resistance in high twist angle in test specimen. This post-cracking resistance is neglected in torsional design of RC members. This strength could be considered in the design of RC members subjected to torsion forces, leading to a more economical and precise design.

Effective torsional strength of axially restricted RC beams

  • Taborda, Catia S.B.;Bernardo, Luis F.A.;Gama, Jorge M.R.
    • Structural Engineering and Mechanics
    • /
    • 제67권5호
    • /
    • pp.465-479
    • /
    • 2018
  • In a previous study, design charts where proposed to help the torsional design of axially restricted reinforced concrete (RC) beams with squared cross section. In this article, new design charts are proposed to cover RC beams with rectangular cross section. The influence of the height to width ratio of the cross section on the behavior of RC beams under torsion is firstly shown by using theoretical and experimental results. Next, the effective torsional strength of a reference RC beam is computed for several values and combinations of the study variables, namely: height to width ratio of the cross section, concrete compressive strength, torsional reinforcement ratio and level of the axial restraint. To compute the torsional strength, the modified Variable Angle Truss Model for axially restricted RC beams is used. Then, an extensive parametric analysis based on multivariable and nonlinear correlation analysis is performed to obtain nonlinear regression equations which allow to build the new design charts. These charts allow to correct the torsional strength in order to consider the favourable influence of the compressive axial stress that arises from the axial restraint.

추진축계 비틀림 진동 감쇠를 위한 점성 댐퍼의 최적 설계 (Optimum Design of Viscous Fluid Damper for Reducing the Torsional Vibration of Propulsion Shaft System)

  • 박상윤;한국현;박주민;권성훈;송오섭
    • 한국소음진동공학회논문집
    • /
    • 제25권9호
    • /
    • pp.606-613
    • /
    • 2015
  • In this study, the torsional vibration analysis for a marine propulsion system is carried out by using the transfer matrix method(TMM). The torsional moment produced by gas pressure and reciprocating inertia force may yield severe torsional vibration problem in the shaft system which results in a damage of engine system. There are several ways to control the torsional vibration problem at hand, firstly natural frequencies can be changed by adjusting shaft dimensions and/or inertia quantities, secondly firing order and crank arrangement are modified to reduce excitation force, and finally lower the vibration energy by adopting torsional vibration damper. In this paper, the viscous torsional vibration damper is used for reducing the torsional vibration stresses of shaft system and it is conformed that optimum model of the viscous damper can be determined by selecting the geometric design parameters of damper and silicon oil viscosity.