• Title/Summary/Keyword: tooth color

Search Result 225, Processing Time 0.022 seconds

TETRACYCLINE에 의한 변색치의 심미적 치료

  • Hwang, Byeong-Gak;Lee, Cheol-Won;Kim, Seok-Gyun
    • Journal of the Korean Academy of Esthetic Dentistry
    • /
    • v.1 no.1
    • /
    • pp.50-57
    • /
    • 1992
  • Intrinsic discoloration of permanent anterior teeth is a continuing esthetic problem. Tetracycline ingested during amelogenesis has long been recognized as predisposing factor in intrinsic staining. Methods for restoring original tooth color have included (1) complete PFM crown coverage (2) porcelain laminate veneers (3) direct bonding of composite resin, and (4) bleaching. In the case of tetracycline-stained upper anterior teeth, We authors, obtained the satisfactory results by means of gingivectomy, preliminary bleaching and porcelain laminate veneer restoration.

  • PDF

Color Distribution of Maxillary Permanent Incisors in Korean Pediatric Patients Using a Spectrophotometer (분광광도계를 이용한 한국 소아 환자의 상악 영구 절치 색조 분석)

  • Seunghyun, Oh;Hyuntae, Kim;Teo Jeon, Shin;Hong-Keun, Hyun;Young-Jae, Kim;Jung-Wook, Kim;Ki-Taeg, Jang;Ji-Soo, Song
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.49 no.4
    • /
    • pp.414-427
    • /
    • 2022
  • This study aims to analyze the color distribution of maxillary permanent incisors in Korean pediatric patients and determine the effects of age and root developmental stage on tooth color. The L*a*b* values of 404 sound and fully erupted maxillary incisors without dental caries, restorations, trauma history or discoloration from 101 Korean patients between ages 7 and 15, with a mean age 10.0 ± 1.5, were analyzed with a spectrophotometer. CIE L*a*b* values were 84.01, 0.17, and 24.07 in maxillary central incisors, and 82.33, 0.31, and 25.99 in maxillary lateral incisors. L* values of maxillary central incisors were higher, and b* values of maxillary central incisors were lower than those of maxillary lateral incisors (p < 0.001). The color differences among the subregions exceeded the clinical perceptibility threshold in both of the maxillary central and lateral incisors. L* value for children at age 10 and younger was 84.13 in maxillary central incisors and 84.04 in maxillary lateral incisors, and those of older patients were 80.62 and 80.56, respectively. L* value of maxillary incisors of children at age 10 and younger was significantly higher than that of older patients. The root developmental stage did not affect tooth color. This study suggests that the color differences between maxillary central and lateral incisors and among the subregions of a tooth and the effects of age should be considered for aesthetic restorations of permanent incisors in pediatric patients.

Oral health and eating habits characteristics relating to maxillary central incisor color of the university students in their twenties (20대 대학생들의 상악중절치 색조와 구강보건 및 식습관 관련 특성)

  • Lee, Ji-Young;Yoon, Young-Suk
    • Journal of Korean society of Dental Hygiene
    • /
    • v.12 no.2
    • /
    • pp.261-273
    • /
    • 2012
  • Objectives : This study aims to prepare the basic data of the teeth color by measuring tooth mode using the color of the maxillary central incisor of the college students in their twenties as the dental colorimeter, and oral health and eating habit characteristics were examined. Methods : The maxillary central incisor(1 teeth) of the subjects of study as 467 students(male 89, female 378) was measured during the period from November 14, December 2 2011, so the color of total 467 teeth were examined, and oral health and eating habit characteristics were researched. Results : 1. As the results of measurement of the shade, value, hue of maxillary central incisor by the general characteristics of the subject, the major(shipbuilding information, special rehabilitation for young children) was higher at 3.3 of the shade, and the grade(1), age($$\geq_-20$$), major(beauty culture & cosmetic, occupational therapy) showed higher at +2 of the value, and the grade(1) and all major showed higher at R3 of the hue. 2. As the results of measurement of the shade, value, hue of maxillary central incisor by the oral health characteristics, the subjective teeth color(yellow) and the education of oral health(no) showed higher at 2.5 of the shade. 3. As the results of measurement of the shade, value, hue of maxillary central incisor by the eating habit characteristics of the subjects, the chocolate showed higher at 3.0 and 2.0 of the shade, and the red pepper paste showed higher at +2 and STD of the value, and the green tea showed higher at $R_3$ of the hue. Conclusions : This study demonstrates that the color of the maxillary central incisor showed differences various tendency according to the oral health and eating habit characteristics.

The study on the dimensional stability of digitized dental stone replicas according to difference color of gypsum materials (치과용 모형재 색상에 따른 디지털 모형의 체적 안정성 연구)

  • Choi, Seog-Soon;Kim, Ki-Baek;Lee, Gyeong-Tak;Jeon, Jin-Hun;Kim, Jae-Hong
    • Journal of Technologic Dentistry
    • /
    • v.34 no.4
    • /
    • pp.369-377
    • /
    • 2012
  • Purpose: The aim of study was to compare the dimensional stability of digitized dental stone replica using different color of gypsum materials using a white light scanner with three-dimensional software. Methods: A master model(500B-1, Nissin dental product, Japan) with the prepared lower full arch tooth was used. Several type IV stones(white, yellow, green) were used for 30 stone casts(10 casts each) duplicated a master model of mandible. The master model and the replicas were digitized with the non-contacting white light scanner to create 3-dimensional digital models. The linear distance between the reference points were measured and analyzed on the Delcam Copycad$^{(R)}$(Delcam plc, UK) 3D graphic software. One-way analysis of variance(ANOVA) combined with a Tukey multiple-range test were used to analysis the data(${\alpha}$=0.05). Results: There were considerable differences in mean values between gypsum materials within each color(white, yellow, green), and this difference was statistically significant, p=0.001. Conclusion: Digitization of dental materials on optical scanner was affected by color. Three different color of gypsum materials showed clinically acceptable accuracies of full arch digital model produced by them. Besides, these results will have to be confirmed in further clinical studies.

AN ACCELERATED TEST FOR COLOR STABILITY AND OPACITY CHANGE OF LIGHT CURING COMPOSITE RESINS (광중합 복합레진의 색안정성 및 투명도 변화에 관한 가속시험)

  • Hwang, Inn-Nam;Oh, Won-Mann
    • Restorative Dentistry and Endodontics
    • /
    • v.18 no.1
    • /
    • pp.215-226
    • /
    • 1993
  • Color stability of tooth colored restorative resins is an important factor, particularly in anterior teeth restoration. The purpose of this study was to evaluate the color stability and opacity change of several light curing composite resins. Specimens of eight composite resins(Prisma AP. H., Brilliant Enamel, Charisma, Durafil, Helio Progress, Herculite XR, P-50 and Silux Plus) were divided into two groups : In Group 1, the specimens were polymerized by visible light curing unit for 60 seconds on both sides and in Group 2, the post-cured specimens were heat tempered by light/heat curing unit for 45 units(about 18 min.). All specimens were stored in distilled water at $60^{\circ}C$ for 30 days. The color characteristics($L^*,a^*,b^*$) and opacity of the specimens before and after immersion were measured by spectrocolorimetry and the total color difference(${\Delta}E^*$) and opacity change (${\Delta}Y%$) were computed. The results obtained were as follows : 1. SP and APH in both groups, DF, HP and HXR in Group 1 showed ${\Delta}E^*$-value above 2.0. 2. DF, HP, SP and HXR in Group 1 showed higher ${\Delta}E^*$-value than in Group 2, but the others had no significant difference. 3. The opacity of CH and HXR in Group 1, and of CH and BE in Group 2 decreased after immersion, while that of the others increased. 4. Opacity change of BE, P50 and HXR was significantly different between Group 1 and 2. These results suggest that color change in the post-cure heat tempered specimens by light/heat curing unit was smaller than that of the specimens polymerized by visible light curing unit. No clinically detectable opacity changes were noted for any materials in either goup.

  • PDF

Influence of toothbrush abrasion and surface treatments on the color and translucency of resin infiltrated hybrid ceramics

  • Labban, Nawaf;Al Amri, Mohammad;Alhijji, Saleh;Alnafaiy, Sarah;Alfouzan, Afnan;Iskandar, Mounir;Feitosa, Sabrina
    • The Journal of Advanced Prosthodontics
    • /
    • v.13 no.1
    • /
    • pp.1-11
    • /
    • 2021
  • PURPOSE. The study compared the color change, lightness, and translucency of hybrid resin ceramics exposed to toothbrush abrasion and surface treatment. MATERIALS AND METHODS. Four hybrid ceramics [Lava Ultimate (LU), Vita Enamic (EN), Shofu HC (SH), and Crystal Ultra (CU)] were compared with a glass-ceramic (Vita Mark II) control. One hundred and twenty specimen blocks were prepared using a precision saw machine. Specimens in each material were divided into four subgroups based on the surface treatment (polishing or staining) and a storage medium (water or citric acid). Simulated tooth brushing with a mixture of 100 RDA (radioactive abrasives) with 0.3 ml distilled water was used for 3650 cycles (7300 strokes) for each specimen. Measurements for the color change, lightness, and translucency were measured after toothbrushing using a spectrophotometer. Statistical analysis compared outcomes using paired t-test, ANOVA, and Tukey post hoc test. RESULTS. The maximum color change was identified in SH (stained acid) [1.44 (0.40)], whereas the lowest was identified in EN (polished water) [0.66 (0.16)] material. The maximum and minimum loss of surface translucency was observed in SH (polished water) [12.3 (0.52)] and EN (stained acid) [6.5 (0.55)] specimens, respectively. Lastly, loss of lightness was the highest in VM (polished acid) [69 (0.95)], whereas the lowest was observed in CU (stained water) [56.7 (0.86)]. CONCLUSION. The comparison presented a significant effect of toothbrush abrasion on translucency and lightness of the hybrid resin ceramics. Color change was not significantly influenced irrespective of the storage medium employed. Surface staining demonstrated the preservation and stability of color and optical properties under the influence of toothbrush abrasion and chemical trauma.

Ceramic color differences of dental Ni-Cr alloy by compositional change (치과용 Ni-Cr 합금의 조성에 따른 세라믹의 색차 분석)

  • Kim, Sa-Im;Kim, Tae-Yeon;Kim, Se-Ha;Kang, Jeong-Gyu;Lee, Jung-Hwan
    • Journal of Technologic Dentistry
    • /
    • v.43 no.4
    • /
    • pp.168-174
    • /
    • 2021
  • Purpose: This study was conducted to investigate alloys spectrophotometrically including yttrium of nickel-chromium (Ni-Cr) alloys, which are used as substitutes for the regulation of beryllium and provide helpful improvements in Ni-Cr alloys. Methods: Four groups of specimens (ZN, ZY, SN and EM) were prepared for analysis. Color parameters were measured with a spectrophotometer, and color difference (∆E*) was calculated. The t-test and one-way analysis of variance test were used to determine significant difference, and the Tukey test was used to identify where the differences were. To measure the spectroscopic reflectivity, the spectroscopic reflectance was measured and converted into CIE L*, a*, b* color system. Results: The ∆E* value of each metal ceramic group after opaque firing of Ni-Cr alloy with and without yttrium was <2, and the total group color difference (∆E*) was below 1 in the dentin ceramic all experimental group. However, the a* and b* values of the metal ceramic groups were higher than that in the lithium disilicate all ceramic group, and the chroma was higher than the natural tooth. The brightness of all experimental groups was similar to that of the shade guide sample. Conclusion: Yttrium added to Ni-Cr alloys showed similar CIE L*, a*, b* values to Ni-Cr alloys that did not contain yttrium, indicating that yttrium had no effect on color in metallic ceramic systems.

Comparison of fracture strength, surface hardness, and color stain of conventionally fabricated, 3D printed, and CAD-CAM milled interim prosthodontic materials after thermocycling

  • Mesut Yildirim;Filiz Aykent;Mahmut Sertac Ozdogan
    • The Journal of Advanced Prosthodontics
    • /
    • v.16 no.2
    • /
    • pp.115-125
    • /
    • 2024
  • PURPOSE. The purpose of this in vitro study was to investigate the fracture resistance, surface hardness, and color stain of 3D printed, CAD-CAM milled, and conventional interim materials. MATERIALS AND METHODS. A total of 80 specimens were fabricated from auto polymerizing polymethyl methacrylate (PMMA), bis-acryl composite resin, CAD-CAM polymethyl methacrylate resin (milled), and 3D printed composite resin (printed) (n = 20). Forty of them were crown-shaped, on which fracture strength test was performed (n = 10). The others were disc-shaped specimens (10 mm × 2 mm) and divided into two groups for surface hardness and color stainability tests before and after thermal cycling in coffee solution (n = 10). Color parameters were measured with a spectrophotometer before and after each storage period, and color differences (CIEDE2000 [DE00]) were calculated. The distribution of variables was measured with the Kolmogorov Smirnov test, and one-way analysis of variance (ANOVA), Tukey HSD, Kruskal-Wallis, Mann-Whitney U tests were used in the analysis of quantitative independent data. Paired sample t-test was used in the analysis of dependent quantitative data (P < .05). RESULTS. The highest crown fracture resistance values were determined for the 3D printed composite resin (P < .05), and the lowest were observed in the bis-acryl composite resin (P < .05). Before and after thermal cycling, increase in mean hardness values were observed only in 3D printed composite resin (P < .05) and the highest ΔE00 value were observed in PMMA resin for all materials (P < .05). CONCLUSION. 3D printing and CAD-CAM milled interim materials showed better fracture strength. After the coffee thermal cycle, the highest surface hardness value was again found in 3D printing and CAD-CAM milled interim samples and the color change of the bis-acryl resin-based samples and the additive production technique was higher than the PMMA resin and CAD-CAM milled resin samples.

Color stability and solubility of Biodentine and NeoPutty in contact with different irrigation solutions

  • Sila Nur Usta;Cangul Keskin
    • Restorative Dentistry and Endodontics
    • /
    • v.49 no.3
    • /
    • pp.25.1-25.9
    • /
    • 2024
  • Objectives: This study aimed to evaluate the color stability and solubility of Biodentine and NeoPutty in contact with different irrigation solutions. Materials and Methods: Biodentine and NeoPutty were set in cylindrical molds with 7 mm diameter and 1.5 mm high and immersed in distilled water, 17% ethylenediaminetetraacetic acid (EDTA), 2% chlorhexidine (CHX), 9% 1-hydroxyethylidene 1,1-diphosphonate (HEDP), and 5% sodium hypochlorite (NaOCl) solutions for 24 hours. The color change was measured with a spectrophotometer. The solubility values were calculated as the mass loss was expressed as a percentage of the original mass using an analytical balance with 10-4 g accuracy. Data were analyzed with Kruskal-Wallis followed by Mann-Whitney U tests, and 2-way analysis of variance test followed by Bonferroni corrections for pairwise comparisons for solubility and color stability with a 5% significance threshold, respectively. Results: Biodentine exhibited higher color changes compared to the NeoPutty contact with all solutions except distilled water (p < 0.05). Both hydraulic cements (HCs) showed higher discoloration values immersion in CHX followed by NaOCl. No statistically significant difference was found between Biodentine and NeoPutty regardless of irrigation solution in terms of solubility (p > 0.05). Solubility values were lower in the distilled water group compared to EDTA and CHX (p < 0.05). Conclusions: Tested HCs showed solubility and color changes at various rates. NeoPutty could be an appropriate material in aesthetic areas. The usage of HEDP as an irrigant solution can be considered suitable for various endodontic treatments due to its relatively lower solubility and discoloration values.

Effects of 3.5% Hydrogen Peroxide Containing Dicalcium Phosphate Dihydrate on the Tooth Enamel Surface (Dicalcium Phosphate Dihydrate를 함유한 3.5% 과산화수소가 치아표면에 미치는 영향)

  • Shim, Youn-Soo
    • Journal of dental hygiene science
    • /
    • v.12 no.4
    • /
    • pp.320-328
    • /
    • 2012
  • The purpose of this study was to evaluate the tooth whitening and properties of an enamel surface after treatments with tooth bleaching agents that contained dicalcium phosphate dihydrate (DCPD) and hydrogen peroxide (HP). Thirty specimens were obtained from fifteen premolar and were randomly divided into three groups (n=10): 1, 3.5% HP + 0 g DCPD; 2, 3.5% HP + 0.1 g DCPD; 3. 3.5% HP + 1 g DCPD. All groups were bleached 8 hours per day for 14 days. With increasing DCPD concentration, the pH values in the agents increased, making it less acidic. However, there was no statistically significant difference (p>.05). As the concentration of DCPD was increased, the concentration of Ca and P was also increased. In all groups, after the tooth whitening, the tooth color was found to have a value of $L^*$ (p<.05). All groups showed significantly decreased enamel microhardness compared to their baseline (p<.05). The percentage microhardness loss (PML) of the group A1 and A2 were significantly lower than that of group A3. The obvious variation of morphology was observed on enamel surfaces in group A1. Following an analysis of the constituents of enamel surface after bleaching, as DCPD content was increased, the amount of Ca and P was increased. In this study, the experimental results suggest that DCPD/HP agent less demineralization changes such as the erosion morphology and hardness loss without compromising whitening efficiency.