• 제목/요약/키워드: tomography, x-ray

검색결과 804건 처리시간 0.029초

미세 X선 단층촬영 기법의 개발과 적용 (Development of X-ray Micro Computed Tomography and Applications)

  • 김승곤;임재홍;김보흠;이의재;이상준
    • 한국가시화정보학회지
    • /
    • 제8권2호
    • /
    • pp.45-50
    • /
    • 2010
  • The objective of this study is to elucidate the feasibility of synchrotron X-ray micro CT as a non-destructive imaging method to visualize the three-dimensional morphological structures of biological and non-biological samples. The experiments were conducted in 7B2 X-ray micro CT beamline in Pohang Accelerate Laboratory (PAL). A rotational 3-axis stage was specially designed for $0^{\circ}-180^{\circ}$ scanning of test samples. Preliminary tests were performed for opaque samples including a mosquito head, a plant seed and gas diffusion layer (GDL) of polymer electrolyte fuel cell to verify the feasibility of the X-ray micro CT. It visualized clearly the internal structure of all the test samples, supporting its usefulness.

Performance analysis of improved hybrid median filter applied to X-ray computed tomography images obtained with high-resolution photon-counting CZT detector: A pilot study

  • Lee, Youngjin
    • Nuclear Engineering and Technology
    • /
    • 제54권9호
    • /
    • pp.3380-3389
    • /
    • 2022
  • We evaluated the performance of an improved hybrid median filter (IHMF) applied to X-ray computed tomography (CT) images obtained using a high-resolution photon-counting cadmium zinc telluride (CZT) detector. To study how the proposed approach improves the image quality, we measured the noise levels and the overall CT-image quality. We established a CZT imaging system with a detector length of 5.12 cm and thickness of 0.3 cm and acquired phantom images. To evaluate the efficacy of the proposed filter, we first modeled two conventional median filters. Subsequently, we were able to achieve a normalized noise power spectrum result of ~10-8 mm2, and furthermore, the proposed method improved the contrast-to-noise ratio by a factor of ~1.51 and the coefficient of variation by 1.55 relative to the counterpart values of the no-filter image. In addition, the IHMF exhibited the best performance among the three filters considered as regards the peak signal-to-noise ratio and no-reference-based image-quality evaluation parameters. Thus, our results demonstrate that the IHMF approach provides a superior image performance over conventional median filtering methods when applied to actual CZT X-ray CT images.

X-ray tomography 분석과 기계 학습을 활용한 금속 3D 프린팅 소재 내의 기공 형태 분류 (Characterization and Classification of Pores in Metal 3D Printing Materials with X-ray Tomography and Machine Learning)

  • 김은아;권세훈;양동열;유지훈;김권일;이학성
    • 한국분말재료학회지
    • /
    • 제28권3호
    • /
    • pp.208-215
    • /
    • 2021
  • Metal three-dimensional (3D) printing is an important emerging processing method in powder metallurgy. There are many successful applications of additive manufacturing. However, processing parameters such as laser power and scan speed must be manually optimized despite the development of artificial intelligence. Automatic calibration using information in an additive manufacturing database is desirable. In this study, 15 commercial pure titanium samples are processed under different conditions, and the 3D pore structures are characterized by X-ray tomography. These samples are easily classified into three categories, unmelted, well melted, or overmelted, depending on the laser energy density. Using more than 10,000 projected images for each category, convolutional neural networks are applied, and almost perfect classification of these samples is obtained. This result demonstrates that machine learning methods based on X-ray tomography can be helpful to automatically identify more suitable processing parameters.

Spectral Computed Tomography: Fundamental Principles and Recent Developments

  • Aaron So;Savvas Nicolaou
    • Korean Journal of Radiology
    • /
    • 제22권1호
    • /
    • pp.86-96
    • /
    • 2021
  • CT is a diagnostic tool with many clinical applications. The CT voxel intensity is related to the magnitude of X-ray attenuation, which is not unique to a given material. Substances with different chemical compositions can be represented by similar voxel intensities, making the classification of different tissue types challenging. Compared to the conventional single-energy CT, spectral CT is an emerging technology offering superior material differentiation, which is achieved using the energy dependence of X-ray attenuation in any material. A specific form of spectral CT is dual-energy imaging, in which an additional X-ray attenuation measurement is obtained at a second X-ray energy. Dual-energy CT has been implemented in clinical settings with great success. This paper reviews the theoretical basis and practical implementation of spectral/dual-energy CT.

3차원 X-ray CT 영상을 이용한 화성암 불균질 지수와 역학적 특성과의 상관관계에 대한 연구 (A Study on Correlation between Heterogeneity Index and Mechanical Properties of Igneous Rocks using 3D X-ray Computed Tomography Image)

  • 정연종;김광염;윤태섭
    • 터널과지하공간
    • /
    • 제27권5호
    • /
    • pp.333-342
    • /
    • 2017
  • 본 연구에서는 국내의 다양한 화성암에 대해 내부구조의 불균질성을 정량화하고, 이와 탄성파속도 및 점하중강도간의 상관관계를 분석하였다. 3차원 X-ray Computed Tomography(CT)를 통해 암석 시편 내부 구조에 대한 정보를 획득하였으며, 3차원 영상에 통계적 기법을 적용하여 뷸균질성 대표계수(representative unit length, LR)를 계산하였다. 또한 암석의 탄성파 속도 및 점하중강도와 LR간의 상관관계로부터 암석의 역학적 특성치를 예측하는 추정식을 제안하였다. 본 연구에서 제안한 방법을 통해 3차원 X-ray 영상에 기반한 내부 특성 분석값을 이용해 실내실험을 수행하지 않고도 암석의 역학적 물성을 평가할 수 있는 간접적인 인자를 도출할 수 있는 가능성을 확인하였다.

Cone beam형 전산화단층영상에서 골의 형태와 밀도의 평가 (Evaluation of imaging reformation with cone beam computed tomography for the assessment of bone density and shape in mandible)

  • 홍상우;김규태;최용석;황의환
    • Imaging Science in Dentistry
    • /
    • 제38권1호
    • /
    • pp.49-56
    • /
    • 2008
  • Purpose: Diagnostic estimation of destruction and formation of bone has the typical limit according to capacity of x-ray generator and image detector. So the aim of this study was to find out how much it can reproduce the shape and the density of bone in the case of using recently developed dental type of cone beam computed tomography, and which image is applied by new detector and mathematic calculation. Materials and Methods: Cone beam computed tomography (PSR 9000N, Asahi Roentgen Ind. Co., Ltd., Japan) and soft x-ray radiography were executed on dry mandible that was already decalcified during 5 hours, 10 hours, 15 hours, 20 hours, and 25 hours. Estimating and comparing of those came to the following results. Results: The change of inferior border of mandible and anterior border of ramus in the region of cortical bone was observed between first 5 and 10 hours of decalcification. The reproduction of shape and density in the region of cortical bone and cancellous bone can be hardly observed at cone beam computed tomography compared with soft x-ray radiography. The difference of decrease of bone density according to hours of decalcification increase wasn't reproduced at cone beam computed tomography compared with soft x-ray radiography. Conclusion: CBCT images revealed higher spatial resolution. However, contrast resolution in region of low contrast sensitivity is the inferiority of images' property.

  • PDF

형광 X선 CT에서 촬상 시간의 단축화 알고리즘 (Algorithm to Shorten Imaging Time in Fluorescent X-ray Computed Tomogrpahy)

  • 정남채
    • 융합신호처리학회논문지
    • /
    • 제2권4호
    • /
    • pp.46-52
    • /
    • 2001
  • 방사광을 이용한 형강 X선 CT 이미징의 고속화를 위한 촬상 시스템과 처리 알고리즘을 검토하였다. 본 논문에서 사용된 촬상시스템은 고계수율 영역에서 안정된 동작을 한 전자 시스템으로 불감시간이 약 6%로 감소되고 계측시간의 경우도 1 점 당 3초로 단축되었다. 또한 재구성 알고리즘의 효율화를 증명하였고, 메모리와 계산량을 약 1/100로 감소시켰다. 물리적 phantom으로 그 정량성을 확인하였고, 시험관내의 갑상선의 화상으로부터 요드 분포를 추정하였다. 이러한 결과는 생체내에서 형광 X선 CT 계측의 실현 가능성을 보여준 것이다.

  • PDF

핵연료 펠릿의 X-선 단층촬영 기반 시뮬레이션 타당성 해석 (X-Ray Tomography Based Simulation Feasibility Analysis of Nuclear Fuel Pellets)

  • 김재준
    • 비파괴검사학회지
    • /
    • 제30권4호
    • /
    • pp.324-329
    • /
    • 2010
  • 원자력발전소에서 사용되고 있는 연료봉은 지르코늄 합금 튜브에 동봉되어 있는 이산화우라늄 펠릿으로 구성되어 있다. 펠릿 표면은 원자로를 가동시키는 동안 국부 핫스팟을 예방하기 위해 튜브로 장전된 후 작은 구멍, 균열, 칩핑 결함이 없어야 한다. 본 논문은 X-선 단층촬영 시뮬레이션을 통하여 핵 연료봉 펠릿의 표면 결함을 검출하기 위한 타당성을 조사하였다. 병렬과 팬빔 여과후 역투영 방법을 이용하여 재구성된 영상은 시뮬레이션 데이터와 MPS(missing pellet surface) 영상데이터의 접근성을 확인하였다.