• Title/Summary/Keyword: tomogram

Search Result 178, Processing Time 0.028 seconds

A RADIOGRAPHIC STUDY OF EXPERIMENTALLY PRODUCED BONE DEFECTS IN THE POSTERIOR WALL OF THE MAXILLARY SINUS (상악동 후벽의 실험적 골결손부에 관한 방사선학적 연구)

  • Choi Eui-Hwan;Park Won-Kyl
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.26 no.2
    • /
    • pp.153-163
    • /
    • 1996
  • The purpose of this study was to evaluate the ability of radiographs in detecting experimental bony defect in the posterior wall of the maxillary sinus. For this study, experimentally five skulls were used, the bony defects with a diameter of 5mm were created at different locations in the posterior wall of the right maxillary sinus and the bony defects of 10mm were created at different locations in the posterior wall of th maxillary sinus. Panoramic view, panoramic sinus view, water's view, and computed tomogram were taken and the results analyzed. The obtanined results were as follows: 1. The panoramic view was superior to the panoramic sinus view in detecting the bony defects in the posterior wall of the maxillary sinus. 2. Panoramic view, panoramic sinus view, and waters's view were limitation to the detection of the bony defects in the posterior wall of the maillary sinus. 3. All the bony defects in the posterior wall of the maxillary sinus were excellently visualized on the computed tomogram.

  • PDF

Evaluation of fracture density distribution for the design of grouting works in fractured rocks (그라우팅 설계를 위한 절리밀도분포 산출법 개발)

  • 김중열;김유성
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2002.03a
    • /
    • pp.627-634
    • /
    • 2002
  • To facilitate a drilling plan for grouting in fractured rock, an algorithm of practical use associated with a new term “fracture density distribution”or“fracture tomogram”is developed. It is well known that Televiewer data(amplitude and traveltime image) provide detailed information about not only dip and dip direction of each fracture but also its aperture size estimated by an appropriate evaluation algorithm. A selected plane section of medium around a borehole or the cross section between two boreholes is discretized into a two dimensional grid of cells(rectangular elements). As each elongated(straight) fracture passes through the cells, the corresponding aperture size value is successively summed up in each cell, depending on the fracture length segment. In this, the fracture lines can be determined by intersecting of each fracture plane with the selected plane section. If the fracture line does not pass through a particular grid element, the segment length is set to zero. The final value(aperture size value of each cell) derived from all the detected fractures constitutes the fracture density distribution of the selected plane section, Field examples are illustrated, which will prove the benefit of the suggested algorithm for several kinds of grouting works.

  • PDF

Acute Appendicitis in Children: Comparison between Present and 10 Year Ago (소아 급성 충수염의 진단과 치료: 10년간의 변화)

  • Kim, Seong-Min;Kim, Se-Hoon;Choi, Hyun-Ho;Han, Seok-Joo;Choi, Seung-Hoon;Hwang, Eui-Ho;Oh, Jung-Tak
    • Advances in pediatric surgery
    • /
    • v.13 no.1
    • /
    • pp.45-51
    • /
    • 2007
  • Appendicitis is the most common surgical emergency in childhood and the technologic advances of modern medicine have affected the diagnosis and treatment of appendicitis. This study is to evaluate the differences in diagnosis and treatment of appendicitis between present and 10 year ago. The authors retrospectively reviewed the medical records of patients who underwent appendectomy under the diagnosis of the acute appendicitis from July 1993 to June 1995 (Group A, n = 78) and from July 2003 to June 2005 (Group B, n = 105). There are no differences between group A and B in mean age ($8.5{\pm}3.6$ vs. $9.3{\pm}3.1$ year), duration of symptoms ($3.0{\pm}3.2$ vs. $2.6{\pm}3.8$ days), and postoperative hospital stay ($6.6{\pm}4.8$ vs. $5.8{\pm}3.6$ days). Preoperative abdominal ultrasonogram and/or computed tomogram was performed in 7 patients (9.0 %) of group A and in 51 patients (58.5 %) of group B. Thirty-six patients (34.3 %) of group B underwent laparoscopic appendectomy, but none in group A. Incidence of a histologically normal appendix decreased from 15.8 % in group A to 4.8 % in group B (p =0.018). This study suggests that utilization of abdominal ultrasonogram or computed tomogram in preoperative evaluation become more popular and surgical treatment of acute appendicitis become more minimally invasive. The rate of negative appendectomy was also reduced compared with 10 year ago.

  • PDF

Application of Simulated Three Dimensional CT Image in Orthognathic Surgery (악교정 수술에서 모의 조종된 3차원 전산화 단층촬영상의 응용)

  • Kim Hyung-Don;Yoo Sun-Kook;Lee Kyoung-Sang;Park Chang-Seo
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.28 no.2
    • /
    • pp.363-385
    • /
    • 1998
  • In orthodontics and orthognathic surgery. cephalogram has been routine practice in diagnosis and treatment evaluation of craniofacial deformity. But its inherent distortion of actual length and angles during projecting three dimensional object to two dimensional plane might cause errors in quantitative analysis of shape and size. Therefore, it is desirable that three dimensional object is diagnosed and evaluated three dimensionally and three dimensional CT image is best for three dimensional analysis. Development of clinic necessitates evaluation of result of treatment and comparison before and after surgery. It is desirable that patient that was diagnosed and planned by three dimensional computed tomography before surgery is evaluated by three dimensional computed tomography after surgery. too. But Because there is no standardized normal values in three dimension now and three dimensional Computed Tomography needs expensive equipments and because of its expenses and amount of exposure to radiation. limitations still remain to be solved in its application to routine practice. If postoperative three dimensional image is constructed by pre and postoperative lateral and postero-anterior cephalograms and preoperative three dimensional computed tomogram. pre and postoperative image will be compared and evaluated three dimensionally without three dimensional computed tomography after surgery and that will contribute to standardize normal values in three dimension. This study introduced new method that computer-simulated three dimensional image was constructed by preoperative three dimensional computed tomogram and pre and postoperative lateral and postero-anterior cephalograms. and for validation of new method. in four cases of dry skull that position of mandible was displaced and four patients of orthognathic surgery. computer-simulated three dimensional image and actual postoperative three dimensional image were compared. The results were as follows. 1. In four cases of dry skull that position of mandible was displaced. range of displacement between computer-simulated three dimensional images and actual postoperative three dimensional images in co-ordinates values was from -1.8 mm to 1.8 mm and 94% in displacement of all co-ordinates values was from -1.0 mm to 1.0 mm and no significant difference between computer-simulated three dimensional images and actual postoperative three dimensional images was noticed(p>0.05). 2. In four cases of orthognathic surgery patients, range of displacement between computer­simulated three dimensional images and actual postoperative three dimensional images in coordinates values was from -6.7 mm to 7.7 mm and 90% in displacement of all co-ordinates values was from -4.0 to 4.0 mm and no significant difference between computer-simulated three dimensional images and actual postoperative three dimensional images was noticed(p>0.05). Conclusively. computer-simulated three dimensional image was constructed by preoperative three dimensional computed tomogram and pre and postoperative lateral and postero-anterior cephalograms. Therefore. potentiality that can construct postoperative three dimensional image without three dimensional computed tomography after surgery was presented.

  • PDF

Comparison of landmark positions between Cone-Beam Computed Tomogram (CBCT) and Adjusted 2D lateral cephalogram (Cone-Beam Computed Tomogram (CBCT)과 Adjusted 2D lateral cephalogram의 계측점 차이에 관한 비교 연구)

  • Son, Soo-Jung;Chun, Youn-Sic;Kim, Minji
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.52 no.3
    • /
    • pp.222-232
    • /
    • 2014
  • Purpose: This study aims to investigate if 2D analysis method is applicable to analysis of CBCT by comparing measuring points of CBCT with those of Adjusted 2D Lateral Cephalogram (Adj-Ceph) with magnification adjusted to 100% and finding out at which landmarks the difference in position appear. Materials and methods: CBCT data and Adj-Ceph (100% magnification) data from 50 adult patients have been extracted as research objects, and the horizontal (Y axis) and vertical (Z axis) coordinates of landmarks were compared. Landmarks have been categorized into 4 groups by the position and whether they are bilaterally overlapped. Paired t-test was used to compare differences between Adj-Ceph and CBCT. Results: Significant difference was found at 11 landmarks including Group B (S, Ar, Ba, PNS), Group C (Po, Or, Hinge axis, Go) and Group D (U1RP, U6CP, L6CP) in the horizontal (Y) axis while all the landmarks in vertical (Z) axis showed significant difference (P<.05). As a result of landmark difference analysis, a meaningful difference with more than 1 mm at 13 landmarks were indentifed in the horizontal axis. In the vertical axis, significant difference over 1 mm was detected from every landmark except Sella. Conclusion: Using the conventional lateral cephalometric measurements on CBCT is insufficient. A new 3D analysis or a modified 2D analysis adjusted on 19 landmarks of the vertical axis and 13 of the horizontal axis are needed when implementing CBCT diagnosis.

Resolution and Image processing Methods of Tomogram and There impact of Computational Velocity Estimation (토모그램의 해상도와 영상처리 기법이 속도예측에 미치는 영향)

  • Lee, Min-Hui;Song, Da-Hee;Keehm, Young-Seuk
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 2009.10a
    • /
    • pp.147-154
    • /
    • 2009
  • Physical properties of rocks, such as velocity, are strongly dependant on detailed pore structures, and recently, pore micro-structures by X-ray tomography techniques have been used to simulate and understand the physical properties. However, the smoothing effect during the tomographic reconstruction procedure often causes an artifact - overestimating the contact areas between grains. The pore nodes near a grain contact are affected by neighboring grain nodes, and are classified into grain nodes. By this artifact, the pore structure has higher contact areas between grains and thus higher velocity estimation than the true one. To reduce this artifact, we tried two image processing techniques - sharpening filter and neural network classification. Both methods gave noticeable improvement on contact areas between grains visually; however, the estimated velocities showed only incremental improvement. We then tried to change the resolutions of tomogram and quantify its impact on velocity estimation. The estimated velocity from the tomogram with higher spatial resolution was improved significantly, and with around 2 micron spatial resolution, the calculated velocity was very close to the lab measurement. In conclusion, the resolution of pore micro-structure is the most important parameter for accurate estimation of velocity using pore-scale simulation techniques. Also the estimation can be incrementally improved if combined with image processing techniques during the pore-grain classification.

  • PDF

Effects of Refraction of Ultrasonic Beam on B-mode Tomograms (B-mode 단층상에서의 초음파 빔의 굴절 영향)

  • 최종수
    • Journal of Biomedical Engineering Research
    • /
    • v.2 no.2
    • /
    • pp.141-144
    • /
    • 1981
  • This paper descirbes about effects of refraction of ultrasonic beam on B-mode tomogram. Both compution based on Snell's law and the experiments performed using B-mode scanner and schlieren optical method are discussed on a circular phantom immersed in water. In these results, if the discrepancy of sound velocity is more than 0. 6%, the distortion of the B-mode image becomes conspicuous and a target beyound the phantom may disappear or displayed as two targets depending on the velocity of the phantom.

  • PDF

Correction of the Refraction Effect on the Real-Time Nonlinear Parameter Tomogram (초음파 비선형 단층영상에 나타나는 굴절의 영향 보정법)

  • 이현주;이강호;최종호;최종수
    • Journal of the Korean Institute of Telematics and Electronics B
    • /
    • v.28B no.5
    • /
    • pp.335-342
    • /
    • 1991
  • A real-tme nonlinear parameter tomography is pumping wave method. This tomorgraphy has a merit which requires no 180$^{\circ}$ projection datum, while the ray-bending effect is remrkably remained on the reconstructed image. In this paper we intend to compensate this ray-bending effect using the perturbation method. Impulsive pumping wave makes derived compensative term simple form, nad the compensative image is easily obtained. We perform computer simulation to confirm the improvement of corrected imate.

  • PDF

A STUDY ON THE LATERAL CEPHALOMETRIC TOMOGRAPHY OF TMJ ARTHROSIS (악관절증의 측방두부계측 단층방사선학적 연구)

  • Lee Ki Hoon
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.17 no.1
    • /
    • pp.89-106
    • /
    • 1987
  • The author obtained individualized lateral cephalometric tomograms from 23 young adults (46 of left and right normal TMJ) with normal occlusion and 20 patients (14 of patient asymptomatic TMJ and 26 of patient symptomatic TMJ) with clicking and painful TMJ after the analysis of submental vertex view. Individualized lateral cephlometric tomogram analysis and TMJ space analysis were performed after tracing each film. All data from these analysis was recorded and statistically processed with CYBER computer system. 1. The results were obtained as follows. In submental vertex view, the mean condylar angulation of Rt. side in normal group was 20.348°±6.358°, Lt. side was 18.870°±7.777° and Rt. side in patient group was 19.350°±7.576° Lt. side was 17.750°±6.146° respectively. The mean condylar angulation of Rt. side was larger than Lt. side in normal and patient group. 2. When the mandible was moved from centric occlusion to centric relation, condylar position relating to the glenoid fossa was placed posteriorly and superiorly in normal TMJ group and patient symptomatic TMJ group. 3. In centric relation position, the proportion of anterior space to posterior space was 1.593 for normal TMJ group, 1.604 for patient asymptomatic TMJ group and 1.671 for patient symptomatic TMJ group. In centric occlusion position, 1.390 for normal TMJ group, 1.539 for patient asymptomatic TMJ group and 1.196 for patient symptomatic group. Normal TMJ group, patient asymptomatic TMJ group and patient symptomatic TMJ group and patient symptomatic TMJ group revealed significant difference in ∠C₂ measurement. (ANOVA-test, p<0.05) 5. Normal group and patient group revealed significant difference in Fh, ∠C₁and ∠C₂ measurement. (T-test, p<0.05) 6. There were strong positive correlation (0.8771) between Fp and Fm, and strong negative correlation (-0.9039) between ∠C₂ and ∠C₁ from the lateral cephalometric tomogram analysis.

  • PDF

Malignant Fibrous Histiocytoma of the Lung - A case report - (폐 악성 섬유성 조직구종 -1예 보고 -)

  • Kim, Dae-Hyun;Kim, Jung-Heon;Kim, Bum-Shik;Park, Joo-Chul
    • Journal of Chest Surgery
    • /
    • v.40 no.11
    • /
    • pp.786-788
    • /
    • 2007
  • Primary malignant fibrous histiocytoma of the lung is extremely rare, A 12-year-old child was admitted to the hospital due to an incidentally detected lung mass. A $2.5{\times}2.5 cm$ sized mass located in the right lower lobe was seen on the chest X-ray, the chest computed tomogram and the positron emission tomogram. We resected the mass through a right lateral thoracotomy and the mass was revealed to be a malignant spindle cell neoplasm on the frozen section diagnosis. So, we performed lobectomy of the right lower lobe with systemic dissection of the mediastinal lymph nodes; the final histopathological diagnosis of the mass was malignant fibrous histiocytoma. The patient was discharged on postoperative day 7 and adjuvant chemotherapy was not applied.