• Title/Summary/Keyword: toe load

Search Result 96, Processing Time 0.027 seconds

Calculation of DSM's Latent capacity for arc-furnace Considered with the Same Time Load Factor (동시부하율을 고려한 전기로의 수요관리 잠재량 산출)

  • Son Hak Sig;Kim In Su;Im Sang Kug;Kim Hyeung Jung;Hur Dong Ryol;Kim Jae Chul
    • Proceedings of the KIEE Conference
    • /
    • summer
    • /
    • pp.82-84
    • /
    • 2004
  • This paper has calculated DSM's latent capacity through a survey investigating electric arc furnaces in over 2,000 toe companies and related organizations. The latent capacity of DSM calculated with the same time load factor is considered in this paper. The time load factor depends on the probability of each electric arc furnace of the value to work and the consideration of experts and technician's experience. Also, this paper verifies the reliability and application of unposed capacity which compared the old latent capacity of Load Management with KEMCO and KEPCO's Direct Load Control gathering capacity.

  • PDF

Hysteretic behaviour of circular tubular T-joints with local chord reinforcement

  • Shao, Y.B.;Wang, Y.M.;Yang, D.P.
    • Steel and Composite Structures
    • /
    • v.21 no.5
    • /
    • pp.1017-1029
    • /
    • 2016
  • When a welded circular hollow section (CHS) tubular joint is subjected to brace axial loading, failure position is located usually at the weld toe on the chord surface due to the weak flexural stiffness of the thin-walled chord. The failure mode is local yielding or buckling in most cases for a tubular joint subjected to axial load at the brace end. Especially when a cyclic axial load is applied, fracture failure at the weld toe may occur because both high stress concentration and welding residual stress along the brace/chord intersection cause the material in this region to become brittle. To improve the ductility as well as to increase the static strength, a tubular joint can be reinforced by increasing the chord thickness locally near the brace/chord intersection. Both experimental investigation and finite element analysis have been carried out to study the hysteretic behaviour of the reinforced tubular joint. In the experimental study, the hysteretic performance of two full-scale circular tubular T-joints subjected to cyclic load in the axial direction of the brace was investigated. The two specimens include a reinforced specimen by increasing the wall thickness of the chord locally at the brace/chord intersection and a corresponding un-reinforced specimen. The hysteretic loops are obtained from the measured load-displacement curves. Based on the hysteretic curves, it is found that the reinforced specimen is more ductile than the un-reinforced one because no fracture failure is observed after experiencing similar loading cycles. The area enclosed by the hysteretic curves of the reinforced specimen is much bigger, which shows that more energy can be dissipated by the reinforced specimen to indicate the advantage of the reinforcing method in resisting seismic action. Additionally, finite element analysis is carried out to study the effect of the thickness and the length of the reinforced chord segment on the hysteretic behaviour of CHS tubular T-joints. The optimized reinforcing method is recommended for design purposes.

A Study on the Fatigue Life Assessment for Load-carrying Fillet Welded Joints using Stress Intensity Factor (응력확대계수를 이용한 하중 전달형 필릿 용접부의 피로강도 평가에 관한 연구)

  • Kim, Myung-Hyun;Kang, Sung-Won;Kim, Hyoung-Rae
    • Journal of Welding and Joining
    • /
    • v.26 no.6
    • /
    • pp.97-102
    • /
    • 2008
  • It is well known that there exist two typical fatigue crack initiation locations in ship structures: one is the weld toe and the other is the weld root where partial penetration weld is performed. In particular, it is important for fillet weldments to avoid weld root cracking in order to prevent catastrophic failure particularly in ship structures. Therefore detail considerations are required for cruciform joints with partial penetration when there is a possibility of weld root crack initiation. For these reasons, fatigue tests on welded joints were performed in this study. Concept of stress intensity factor(SIF) by means of fracture mechanics is applied for predicting fatigue life of fillet welded joints.

Fatigue Strength of the Load-Carrying Cruciform Fillet Welded Joints Using the Hot-Spot Stress (Hot-Spot 응력을 이용한 하중전달형 십자형 필렛 용접재의 피로강도 평가)

  • Park, Jong-Min;Choi, Won-Sik;Kwon, Soon-Hong;Noh, Byeong-Wook
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.6 no.1
    • /
    • pp.20-26
    • /
    • 2007
  • In this study, fatigue strength of load-carrying cruciform fillet welded joints were evaluated using a new method proposed by Yamada, for geometric or structural stress in welded joint, that is, one-millimeter stress below the surface in the direction corresponding to the expected crack path. Validity of the method is verified by analyzing fatigue test results for load-carrying cruciform welded specimens has different size of weld toe radius, leg length and plate thickness reported in literature. Structural stress concentration factor for 1mm below the surface was calculated by finite element analysis for each specimen respectively. When compared to the basic fatigue resistance curve offered by BS7608, the one-millimeter stress method shows conservative evaluation for load-carrying cruciform fillet welded joints.

  • PDF

A Study on the Fatigue Strength Evaluation of Load-Carrying Fillet welded Cruciform Joints (하중전달 십자형 필렛 용접부의 피로강도 평가에 관한 연구)

  • Lee, Yong-Bok;Nam, Byung-Chan;Park, In-Kju;Chung, Chin-Sung;Kim, Ho-Kyung
    • Proceedings of the KSME Conference
    • /
    • 2000.04a
    • /
    • pp.200-205
    • /
    • 2000
  • Fatigue failure modes of load-carrying cruciform weld joints are dependent on the characteristics of the fatigue crack initiation and propagation from the weld toe or the weld root. In this study, constant amplitude fatigue tests on load-carrying fillet welded specimen carried out, and fatigue strengths were evaluated. Also, an attempt is made to develop a new analytical model with more accuracy to predict the fatigue crack propagation life of fillet welded cruciform joints of SWS 490B steels containing lack of penetration defects. From the result of this study, fatigue crack growth characteristics of load-carrying fillet welded cruciform joints, containing lack of penetration defects are found to be affected by the weld geometry, stress range and microstructures of the weld zone.

  • PDF

The Study of Load Test Method for In-Site Casting Pile In High Rise Building. (초고층에서의 현장타설말뚝 재하시험방법 고찰)

  • Kim, Dae-Hak;Hong, Young-Kil;Han, Sung-Moo;Gu, Ung-Hwoe;Park, Chan-Duck
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2008.03a
    • /
    • pp.385-392
    • /
    • 2008
  • Modern city have had a lot of high-rise building in high standards and multi-level performance. Using of city space reach better stages by using integration. These skyscraper have increased working load on ground. that building is efficiently designed for that soil capacity is well applied. With material side, big size pile, high strength concrete and high strength steel is used for that getting enough lobby space and resisting load increased of high-rise building. limit load test and load transmitted test can make soil capacity optimized. By the way, method of measuring pile capacity is more advanced and bigger. pile type applied by high rise building have underground excavation space, also reflect regional soil property and have some fact reviewed. A lot of high rise building recently is built as land mark in Seoul, Busan and Incheon. about method of measuring capacity of foundation pile, example of construction field is compared and reviewed.

  • PDF

Characteristics on the Vertical Load Capacity Degradation for Impact driven Open-ended Piles During Simulated Earthquake /sinusoidal Shaking, (타격관입 개단말뚝의 동적진동에 의한 압축지지력 저감특성)

  • 최용규
    • Geotechnical Engineering
    • /
    • v.12 no.6
    • /
    • pp.51-64
    • /
    • 1996
  • After the model open-ended pile attached with strain gages was driven into a pressure chamber, in which the saturated microfine sand was contained, the static compression loading test was performed for that pile. Based on the test results, ultimate pile capacity was determined. Then, either simulated earthquake shaking or sinusoidal shaking was applied to the pile with the sustained certain level OP ultimate pile load. Then, pile capacity degradations characteristics during shaking were studied. Pile capacity degradation during two different shakings were greatly different. During the simulated earthquake shaking, capacity degradation depended upon the magnitude of applied load. When the load applied to the pile top was less than 70% of ultimate pile capacidy, pile capacity degradation rate was less than 8%, and pile with the sustained ultimate pile load had the degradation rate of 90%. Also, most of pile capacity degradation was reduced in outer skin friction and degradation rate was about 80% of ultimate pile capacity reduction. During sinusoidal shaking, pile capacity degradation did not depend on the magnitude of applied load. It depended on the amplitude and the frequency , the larger the amplitude and the fewer the frequency was, the higher the degradation rate was. Reduction pattern of unit soil plugging (once depended on the mode of shaking. Unit soil plugging force by the simulated earthquake shaking was reduced in the bottom 3.0 D, of the toe irrespective of the applied load, while reduction of unit soil plugging force by sinusoidal shaking was occurred in the bottom 1.0-3.0D, of the toe. Also, the soil plugging force was reduced more than that during simulated earthquake shaking and degradation rate of the pile capacity depended on the magnitude of the applied load.

  • PDF

Case Studiy on Measurement of End Bearing Capacity for Large Diameter Drilled Shaft Constructed in Fault Zone using Loading Test (선단유압재하시험을 이용한 단층파쇄대에 설치된 대구경 현장타설말뚝의 선단지지력 측정 사례)

  • Jung, Chang-Kyu;Kim, Tae-Hoon;Jung, Sung-Min;Hwang, Kun-Bae;Choi, Yong-Kyu
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2004.03b
    • /
    • pp.74-81
    • /
    • 2004
  • In this study, static end loading tests with load transfer measurement were accomplished for large diameter drilled shaft constructed in fault zone. Yield pile capacity (or ultimate pile capacity) from load-settlement curve was determined and axial load transfer behavior was measurd. The end bearing capacity was increased 2 times due to grouting the toe ground under pile base.

  • PDF

A Study on the Development of New Rail Fastening Devices (철도레일체결장치의 국내 독자모델 개발에 관한 연구)

  • Kwon, Tae-Soo;Cho, Yong-Hyeon
    • Proceedings of the KSME Conference
    • /
    • 2001.06a
    • /
    • pp.819-824
    • /
    • 2001
  • Most of rail fastening system used in the interior have depended on the foreign technologies. In this study, new rail fastening device is developed to estabilish the domestic technology. Especially, Pandrol and Vossloh rail fastening devices are analyzed to utilize the weak and strong points. New rail fastening device is designed to combine advantages of two other foreign devices.

  • PDF

Changes of relative impulse of foot on carrying 5 types of schoolbag during level walking (가방 휴대 방법에 따른 보행 시 발의 비례추진력 변화)

  • Pack, Soo-Jin;Kim, Min-Hee;Kim, Jin-Sang
    • The Journal of Korean Physical Therapy
    • /
    • v.21 no.3
    • /
    • pp.61-68
    • /
    • 2009
  • Purpose: The purpose of this study was to analyze the changes of the relative impulse of the foot when carrying 5 types of schoolbag during level walking. Methods: Forty-four normal subjects were divided into 5 groups according to the method of carrying a bag: carrying no bag (condition 1), a backpack (condition 2), a shoulder bag (condition 3), a cross bag (condition 4) and a one-hand bag (condition 5). To evaluate the partial relative impulse, 7 areas were measured on the sole of a foot: the hallux, toe, 1st metatarsal head (Met1) and the 2nd & 3rd metatarsal heads (Met2/3), the 4th & 5th metatarsal heads (Met4/5), mid foot and heel. Repeated one-way analysis of variance (ANOVA) and independent t-tests were used to analyze the statistical data. Results: In the right foot, the relative impulses in every areas revealed no significant difference (p>0.05), however, the relative impulses at Met1, Met2/3, Met4/5 and heel were significantly different between the different conditions (p<0.05). There were significant differences on comparing the relative impulse between left and right foot within one condition, the mid foot in condition 2, as well as the hallux and Met1 in condition 3 (p<0.05). In condition 4, the toe, Met1, Met4/5 and mid foot were significantly different (p<0.05). The values at the hallux, toe and Met1 in condition 5 also were significantly different (p<0.05). Conclusion: These findings showed that the symmetrical relative impulse of the foot was present in the case of carrying a backpack, but there was an extra load on specific regions and asymmetrical relative impulses in the case of carrying a shoulder bag, a across bag and a one-hand bag. (ED note: this abstract is not clear. You need to work on it.)

  • PDF