• 제목/요약/키워드: titanium surface

검색결과 1,169건 처리시간 0.04초

임플란트-지대주-나사의 적합에 관한 연구 (A STUDY ON THE FIT OF THE IMPLANT-ABUTMENT-SCREW INTERFACE)

  • 김낙형;정재헌;손미경;백대화
    • 대한치과보철학회지
    • /
    • 제41권4호
    • /
    • pp.503-518
    • /
    • 2003
  • Statement of problem : There have been previous studies about considerable variations in machining accuracy and consistency in the implant-abutment-screw interfaces. Purpose : The purpose of this study was to evaluate the machining accuracy and consistency of implant/abutment/screw combinations on two randomly selected implants from each of four manufactures. Material and methods : In this study, screws were respectively used to secure a cemented abutment, to a hexlock implant fixture ; teflon coated titanium alloy screw(Torq-Tite) and titanium alloy screw in Steri--Oss system, gold-plated gold-palladium alloy screw(Gold-Tite) and titanium alloy screw in 3i system gild screw ana titanium screw in AVANA Dental Implant system, and titanium screws in Paragon System. The implants were perpendicularly mounted in polymethyl methacrylate autopolymerizing acrylic resin block(Orthodontic resin, Densply International Inc. USA) by use of dental surveyer. Each abutment screw was secured to the implant with recommended torque value using a digital torque controller. Each screw was again tightened after 10 minutes. All samples were cross sectioned with grinder-polisher unit(Omnilap 2000 SBT Inc) after embeded in liquid unsaturated polyester (Epovia, Cray Valley Inc) Results : There were the largest gaps in the neck areas of screws in hexagonal extension implants which were examined in this study. The leading edge of the abutment screw thread (superior surface) was in contact with the implant body thread, and the majority of the contacting surfaces were localized to the middle portion of the mating threads. Considerable variation in the contacting surfaces was noted in the samples evaluated. Amounts of contact in the abutment screw thread were larger for assemblies with Gold-Tite screw, gold alloy screw. Torq-Tite screw than those with titanium screws. The findings of intimate contact between the screw and screw seat were seen in all samples, regardless of manufacturers. However, microgap between the head and lateral neck surface of the screw and the abutment could be dectected in all samples. The findings of intimate contact between the platform of the implant and the bottom of the abutment were consistent in all samples, regardless of manufacturers. However, microgaps between the lateral surface of external hex of the fixture and the abutment could be dectected in all samples. Conclusion : Considerable variations in machining accuracy and consistency were noted in the samples and the implant-abutment-screw interfaces were incomplete. From the results of this study, further development of the system will be required, including improvements in pattern design.

가토의 두개골에서 Pore의 유무에 따른 티타늄 반구에서의 골형성 능 (The Bone Formation Potency on the Titanium Cap According to the Pore on the Rabbit Calvarium)

  • 박정표;오철중;정승곤;박홍주;오희균;유선열;국민석
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제35권1호
    • /
    • pp.18-24
    • /
    • 2013
  • Purpose: This study is performed to determine the effects of titanium cap with various sizes of pores on bone formation during guided bone regeneration (GBR). Methods: Calvaria from 10 adult male rabbits were chosen as the recipient sites. A trephine bur with a diameter of 10 mm was used to form one round groove on each side of sagittal suture of the cranium, and a round bur with a diameter of 1.5 mm was used to form 6 small holes on the inner circles of round grooves to induce bleeding. In the control group, bone graft was not conducted, and closed titanium cap was fixed in the round groove. Bone graft was not performed in groups 1 and 2, but fixed on titanium caps with 0.2 mm, and 0.5 mm sized pores, respectively. For groups 3, 4, and 5, a synthetic bone graft material (${\beta}$-tricalcium phosphate, Cerasorb$^{(R)}$, Germany) was transplanted, and titanium caps without pore, with 0.2 mm and 0.5 mm sized pore were fixed, respectively. The animals were sacrificed 4 weeks after, and clinical, radiographical, and histomorphometrical evaluation of bone regeneration was performed. Results: In all groups, there were no clinical signs of infection, inflammation or wound dehiscence. Radiographic evaluation revealed well-defined semi-circular radiopacity inside the titanium cap of groups 3, 4, and 5. Histologically, the inner surface of the hemisphere was evenly lined with newly formed bone tissue, as well as grafted bone material in the group 3. In groups 4 and 5, the insertion of connective tissue was observed along the inner surface. However, the overall surface area between the grafts with different holes yielded no statistical significance in the histomorphometrical evaluation. Conclusion: Although the total area of newly formed bone showed no significant difference, excellent bone formation tendency was observed histologically when closed caps were used with bone graft was accompanied.

SURFACE CHARACTERISTICS AND BIOLOGICAL RESPONSES OF HYDROXYAPATITE COATING ON TITANIUM BY HYDROTHERMAL METHOD: AN IN VITRO STUDY

  • Kim, Dong-Seok;Kim, Chang-Whe;Jang, Kyung-Soo;Lim, Young-Jun
    • 대한치과보철학회지
    • /
    • 제43권3호
    • /
    • pp.363-378
    • /
    • 2005
  • Statement of problem. Hydroxyapatite(HA) coated titanium surfaces have not yet showed the reliable osseointegration in various conditions. Purpose. This study was aimed to investigate microstructures, chemical composition, and surface roughness of the surface coated by the hydrothermal method and to evaluate the effect of hydrothermal coating on the cell attachment, as well as cell proliferation. Material and Methods. Commercially pure(c.p.) titanium discs were used as substrates. The HA coating on c.p. titanium discs by hydrothermal method was performed in 0.12M HCl solution mixed with HA(group I) and 0.1M NaOH solution mixed with HA(group II). GroupⅠ was heated at 180 $^{\circ}C$ for 24, 48, and 72 hours. GroupⅡ was heated at 180 $^{\circ}C$ for 12, 24, and 36 hours. And the treated surfaces were evaluated by Scanning electron microscopy(SEM), Energy dispersive X-ray spectroscopy(EDS), X-ray photoelectron spectroscopy(XPS), X-ray diffraction method(XRD), Confocal laser scanning microscopy(CLSM). And SEM of fibroblast and 3-(4,5- dimethylthiazol-2-yl)-2,5-diphenyl tetrazolium bromide(MTT) assay were used for cellular responses of the treated surfaces. Results. The color of surface changed in both groups after the hydrothermal process. SEM images showed that coating pattern was homogeneous in group II, while inhomogeneous in group I. H72 had rosette-like precipitates. The crystalline structure grew gradually in group II, according to extending treatment period. The long needle-like crystals were prominent in N36. Calcium(Ca) and phosphorus(P) were not detected in H24 and H48 in EDS. In all specimens of group II and H72, Ca was found. Ca and P were identified in all treated groups through the analysis of XPS, but they were amorphous. Surface roughness did not increase in both groups after hydrothermal treatment. The values of surface roughness were not significantly different between groups I and II. According to the SEM images of fibroblasts, cell attachments were oriented and spread well in both treated groups, while they were not in the control group. However, no substantial amount of difference was found between groups I and II. Conclusions. In this study during the hydrothermal process procedure, coating characteristics, including the HA precipitates, crystal growth, and crystalline phases, were more satisfactory in NaOH treated group than in HCl treated group. Still, the biological responses of the modified surface by this method were not fully understood for the two tested groups did not differ significantly. Therefore, more continuous research on the relationship between the surface features and cellular responses seems to be in need.

산질화 표면에서의 액적 증발 열전달 성능 분석 (Analysis of Heat Transfer Performance of Oxi-nitriding Surface during Droplet Evaporation)

  • 김대윤;이성혁
    • 한국분무공학회지
    • /
    • 제24권4호
    • /
    • pp.203-208
    • /
    • 2019
  • In general, the oxi-nitriding method is well known as such a surface treatment way for substantial enhancement in corrosion resistance, even comparable to that of titanium. However, there are still lacks of information on thermal performance of the oxi-nitriding surface being of additional compound layers on the base substrate. Above all, the quantitative measurement of its thermal performance still was not evaluated yet. Thus, the present study experimentally measures the thermal resistance of the oxi-nitriding surface during droplet evaporation and then estimates heat transfer performance with the use of the onedimensional heat transfer model in vertical direction. From the experimental results, it is found that the total evaporation time slightly increased with the thermal resistance caused by the oxi-nitriding layer, showing a maximum difference of approximately 20% with that of the bare surface. Although the heat transfer performance of oxi-nitriding surface became slightly lower than that of the bare surface, the oxi-nitriding surface exhibits much better heat transfer performance compared to titanium.

The effect of root canal preparation on the surface roughness of WaveOne and WaveOne Gold files: atomic force microscopy study

  • Ozyurek, Taha;Yilmaz, Koray;Uslu, Gulsah;Plotino, Gianluca
    • Restorative Dentistry and Endodontics
    • /
    • 제43권1호
    • /
    • pp.10.1-10.8
    • /
    • 2018
  • Objectives: To examine the surface topography of intact WaveOne (WO; Dentsply Sirona Endodontics) and WaveOne Gold (WOG; Dentsply Sirona Endodontics) nickel-titanium rotary files and to evaluate the presence of alterations to the surface topography after root canal preparations of severely curved root canals in molar teeth. Materials and Methods: Forty-eight severely curved canals of extracted molar teeth were divided into 2 groups (n = 24/each group). In group 1, the canals were prepared using WO and in group 2, the canals were prepared using WOG files. After the preparation of 3 root canals, instruments were subjected to atomic force microscopy analysis. Average roughness and root mean square values were chosen to investigate the surface features of endodontic files. The data was analyzed using one-way analysis of variance and post hoc Tamhane's tests at 5% significant level. Results: The surface roughness values of WO and WOG files significantly changed after use in root canals (p < 0.05). The used WOG files exhibited higher surface roughness change when compared with the used WO files (p < 0.05). Conclusions: Using WO and WOG Primary files in 3 root canals affected the surface topography of the files. After being used in root canals, the WOG files showed a higher level of surface porosity value than the WO files.