• Title/Summary/Keyword: titanium oxide film

Search Result 130, Processing Time 0.022 seconds

Electrochemical Synthesis of TiO2 Photocatalyst with Anodic Porous Alumina

  • Hattori, Takanori;Fujino, Takayoshi;Ito, Seishiro
    • Korean Journal of Materials Research
    • /
    • v.17 no.11
    • /
    • pp.593-600
    • /
    • 2007
  • Aluminum was anodized in a $H_2SO_4$ solution, and titanium (IV) oxide ($TiO_2$) was electrodeposited into nanopores of anodic porous alumina in a mixed solution of $TiOSO_4$ and $(COOH)_2$. The photocatalytic activity of the prepared film was analyzed for photodegradation of methylene blue aqueous solution. Consequently, we found it was possible to electrodeposit $TiO_2$ onto anodic porous alumina, and synthesized it into the nanopores by hydrolysis of a titanium complex ion under AC 8-9 V when film thickness was about $15-20{\mu}m$. The photocatalytic activity of $TiO_2$-loaded anodic porous alumina ($TiO_2/Al_2O_3$) at an impressed voltage of 9 V was the highest in every condition, being about 12 times as high as sol-gel $TiO_2$ on anodic porous alumina. The results revealed that anodic porous alumina is effective as a substrate for photocatalytic film and that high-activity $TiO_2$ film can be prepared at low cost.

BIOLOGICAL RESPONSES OF OSTEOBLAST-LIKE CELLS TO DIFFERENT TITANIUM SURFACE BY ANODIZING MODIFICATION

  • Kim Myung-Joo;Kim Chang-Whe;Lim Young-Jun;Park Hyun-Joo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.43 no.6
    • /
    • pp.751-763
    • /
    • 2005
  • Statement of problem. To improve a direct implant fixation to the bone, various strategies have been developed focusing on the surface of materials. The surface quality of the implant depends on the chemical, physical, mechanical and topographical properties of the surface. The different properties will interact with each other and a change in thickness of the oxide layer may also result in a change in surface energy, the surface topography and surface, chemical composition. However, there is limited the comprehensive study with regard to changed surface and biologic behavior of osteoblast by anodization. Purpose of study. The aim of this study was to analyze the characteristics of an oxide layer formed and to evaluate the cellular biologic behaviors on titanium by anodic oxidation (anodization) by cellular proliferation, differentiation, ECM formation and gene expression. And the phospholipase activity was measured on the anodized surface as preliminary study to understand how surface properties of Ti implant are transduced into downstream cellular events. Methods and Materials. The surface of a commercially pure titanium(Grade 2) was modified by anodic oxidation. The group 1 samples had a machined surface and other three experimental specimens were anodized under a constant voltage of 270 V(Group 2), 350 V(Group 3), and 450 V(Group 4). The specimen characteristics were inspected using the following five categories; the surface morphology, the surface roughness, the thickness of oxide layer, the crystallinity, and the chemical composition of the oxide layer. Cell numbers were taken as a marker for cell proliferation. While the expression of alkaline phosphatase and Runx2 (Cbfa1) was used as early differentiation marker for osteoblast. The type I collagen production was determined, which constitutes the main structural protein of the extracellular matrix. Phospholipase $A_2$ and D activity were detected. Results. (1) The anodized titanium had a porous oxide layer, and there was increase in both the size and number of pores with increasing anodizing voltage. (2) With increasing voltage, the surface roughness and thickness of the oxide film increased significantly (p<0.01), the $TiO_2$phase changed from anatase to rutile. During the anodic oxidization, Ca and P ions were more incorporated into the oxide layer. (3) The in vitro cell responses of the specimen were also dependant on the oxidation conditions. With increasing voltage, the ALP activity, type I collagen production, and Cbfa 1 gene expression increased significantly (p<0.01), while the cell proliferation decreased. (4) In preliminary study on the relation of surface property and phospholipase, PLD activity was increased but $PLA_2$ activity did not changed according to applied voltage. Conclusion. The anodized titanium shows improved surface characteristics than the machined titanium. The surface properties acquired by anodization appear to give rise more mature osteoblast characteristics and might result in increased bone growth, and contribute to the achievement of a tight fixation. The precise mechanism of surface property signaling is not known, may be related to phospholipase D.

Study of PEO Process for Al 7075 and Effect of additives (알루미늄 7075 합금의 PEO 처리 기술 및 첨가제 영향 분석)

  • Jin, Yun-Ho;Yang, Jae-Kyo
    • Journal of the Korean institute of surface engineering
    • /
    • v.53 no.2
    • /
    • pp.53-58
    • /
    • 2020
  • In this study, we developed plasma electrolytic oxidation (PEO) process for aluminum 7075 alloy to improve the corrosion and mechanical properties. The electrolyte consists of potassium hydroxide and sodium silicate. Additionally, sodium stannate was added into the electrolyte to investigate its effect on PEO film formation. Titanium was used as the counter electrode. Plasma generation voltage reduced from 300V to 150 V by adding 4 g/L of sodium stannate. The thin oxide films were observed by SEM(Scanning Electron Microscopy)/EDS (Energy Dispersive Spectroscopy) for quantitative and qualitative analyses. XRD (X-ray diffraction) and XRF (X-ray Fluorescences) analyses were also carried out to identify oxide layer on aluminum 7075 surface. Vicker's hardness test was performed on the PEO-treated aluminum 7075 surface.

Chemical Binding States of Ti and O Elements in Anodic Ti Oxide Films (Ti 양극산화 피막에서 Ti 및 O원소의 화학결합 상태)

  • 유창우;오한준;이종호;장재명;지충수
    • Journal of the Korean institute of surface engineering
    • /
    • v.35 no.6
    • /
    • pp.383-390
    • /
    • 2002
  • To investigate behaviors of Ti and O elements and microstructures of anodic titanium oxide films, the films were prepared by anodizing pure titanium in $H_2$S $O_4$, $H_3$P $O_4$, and $H_2O$$_2$ mixed solution at 180V. The microstructures and chemical states of the elements were analyzed using SEM, X-ray mapping, AFM, XRD, XPS (depth profile). The films formed on a titanium substrate showed porous layers which were composed of pore and wall, And with increasing anodizing time a hexagonal shape of cell structures were dominant and solace roughness increased. From the XRD result the structure of the Ti $O_2$ layer was anatase type of crystal on the whole. In the XPS spectra it was found that Ti and O were chemically binded in forms of Ti $O_2$, TiOH, $Ti_2$ $O_3$ at Ti 2p, and Ti $O_2$, $Ti_2$ $O_3$, $P_2$ $O_{5}$, S $O_4^{2-}$ at O ls respectively. Concentration of Ti $O_2$ decreased as the depth increased from the surface of the oxide film towards the substrate, but to the contrary concentrations of TiOH and $Ti_2$ $O_3$ increased.d.

Characteristics of Fluoride Releasing of Anodized Titanium Implant (양극산화 아크방전 처리한 티타늄 임플란트의 불소방출 특성)

  • Kim, Ha-young;Song, Kwang-yeob;Bae, Tae-sung
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.24 no.4
    • /
    • pp.361-369
    • /
    • 2008
  • The purpose of this study is to make porous oxide film on the surfaces of pure Ti through anodic spark discharge in electrolytic solution containing calcium and phosphate ions, to improve osseointergration by treating fluoride agent. In addition, it is to evaluate the fluoride modified effect on the surface. Commercial pure Ti plate with $20{\times}10{\times}2mm$ and Ti wire with a diameter of 1.5mm and a total length of 15mm were used. After making titanium oxide films converted by anodic spark discharge, anodizing was performed. Fluoride was spreaded to titanium laboratory plate and maintained for 30 minutes after anodizing breakdown. Fluoride ion discharge amount was measured per 24 hours after dipping titanium plate into saline (10ml) and sustaining 90rpm in a pyrostat. Some plates and wires were dipped in Hanks solutions for a month to examine biocompatibility using SEM and XRD. $TiO_2$ film formed by anodic discharge technique showed great roughness and uniform pores which were $1{\sim}3{\mu}m$ in a diameter. Roughness of the films treated with anodic discharge after blasting were higher than the turned ones(P<0.05). Rapid surface activity was observed in the samples treated with $TiF_3$ agent, which immersed in Hanks solution for 30 days. Taking the results into consideration, the fluoride modified implant with anodic discharge demonstrates that it makes uniformly porous oxide film on the surface of implant and properly increase roughness for osseointegration. The implants will achieve greater bone integration after short healing time by improving surface activity.

The Biocompatibility of HA Film Deposition on Anodized Titanium Alloy

  • Lee, Kang;Choe, Han-Choel;Kim, Byung-Hoon;Ko, Yeong-Mu
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2009.10a
    • /
    • pp.213-214
    • /
    • 2009
  • A thin film hydroxyapatite (HA) films was deposited on anodized titanium by RF sputtering method. The anodized titanium enhanced the biocompatibility of the Ti and the bioactivity was improved further by the HA deposited on the anodized Ti. $TiO_2$ layer with $0.2{\sim}0.5{\mu}$ diameter pore size was formed on the Ti surface by anodization. Anodized $TiO_2$ layer analysis HA film deposited, oxide pore size and number decreased compared with non-HA deposited surface. The corrosion resistance of HA deposited/anodized Ti was higher than that of the non-treatment Ti alloy in Hank's solution, indicating better protective effect. From the results of cell culture using MTT assays, the best cell proliferation showed in HA deposited surface after anodization of Ti surfaces compared with another surface treatment.

  • PDF

Electrochemical Behavior and Morphology of Anodic Titanium Oxide Films (양극산화에 의한 티타늄 산화피막의 전기화학적 거동과 형상)

  • Byeon K.J.;Kim C.S.;Zhu Xiaolong;Kim K.H.
    • Journal of Biomedical Engineering Research
    • /
    • v.21 no.3 s.61
    • /
    • pp.273-277
    • /
    • 2000
  • The galvanostatic anodization of commercially Pure titanium plate (c.p.Ti, grade 2) was investigated in various concentrations of aqueous $H_3PO_4$ from 0.05M to 0.7M. The surfaces of anodic oxide films, formed by the current density in the range between 0.3 and $l.0 A/dm^2$. were analyzed by SEM and XRD. The voltage-time (V-T) curves displayed an initial linear part and a subsequent parabolic part, and the initial slopes increased with an increase in the current density in 0.05M $H_3PO_4$. As the concentration of the electrolyte increased, the V-T corves exhibit no change but the final voltage decreased. The anodic oxide film of titanium developed from fine grains to snowflake-like grains in a layered structure with an increase in the concentration of the electrolyte and current density. Sparking at the interface of the oxide/electrolyte accompanied the local deposition and dissolution of the oxide film through discharging. The crystallinity of the anodic oxide film increased with the anodizing voltage and decreased with an increase in the concentration of the electrolyte.

  • PDF

Aspects of Nanotechnology In Inorganic Sunscreen Dispersions: Efficacy and Aesthetics

  • Arthur Georgalas
    • Proceedings of the SCSK Conference
    • /
    • 2003.09a
    • /
    • pp.97-97
    • /
    • 2003
  • Chemists must take into consideration more factors to formulate with inorganic sunscreens than many other active ingredients including organic sunscreens. Because the UV radiation attenuation grade particles of Titanium Dioxide and Zinc Oxide are in the nanometer range, the state of their dispersion in the product film on the skin governs their efficacy and aesthetics.(omitted)

  • PDF

Study on the Improvement of $TiSi_2$ film for Ti-SALICIDE Process Using Ion Beam Mixing and Rapid Thermal Annealing (Ion Beam Mixing과 급속열처리 방법을 이용한 Ti-SALICIDE용 $TiSi_2$ 박막 개선에 관한 연구)

  • 최병선;구경완;천희곤;조동율
    • Journal of the Korean Vacuum Society
    • /
    • v.1 no.1
    • /
    • pp.168-175
    • /
    • 1992
  • The surface and interface morphology as well as the sheet resistance, and uniformity of TiSiz film are significantly improved and the lateral titanium silicide growth over the oxide spacer is minimized by the use of ion beam mixing and rapid thermal annealing in nitrogen ambient. In addition, TiSiz film formations on TiISi and TiISiOz system were also studied.

  • PDF