• 제목/요약/키워드: tissue level

검색결과 2,396건 처리시간 0.03초

어유가 흰쥐조직내 당, 지방대사에 관여하는 효소활성도에 미치는 영향 (Effect of Fish Oil Diet on Activities of Lipogenic Enzymes and Glucose-6-phosphatase in Rat Liver and Adipose Tissue)

  • 정승은
    • 대한간호학회지
    • /
    • 제19권3호
    • /
    • pp.299-306
    • /
    • 1989
  • In order to evaluate the effect of fish oil on lipid drogenase(G6PDH), malic enzyme(ME), glucose-6-phosphatase(G6Pase) activities were measured in liver and adipose tissue of rats fed 13 days supplemented fish oil at the level of 10% (W/W). Two other groups of rats were fed 10% soybean oil or lard to compare with the effect of fish oil. In all groups, activities of hepatic G6PDH and ME were depressed from the beginning of feeding. This effect was greatest (50%) in fish oil group. Hepatic G6Pase was highest in rats fed lard. When the level of fish oil was reduced to half, as total fat content was maintained at the level of 10% by complementary lard, lipogenic enzyme depressing effect of fish oil was as significant as shown in 10% fish oil diet. Hepatic G6PDH was depressed significantly(14%) in rats fed fish oil as low as 2%. On the other hand, changes in adipose tissue G6PDH and ME activities were small. Adipose tissue G6Page activity increased slightly in rats fed with increasing fish oil(above 0.5%). It is suggested that fish oil alter, more markedly than either soybean oil or lard, cellular lipid metabolism by reducing activities of hepatic lipogenic enzymes.

  • PDF

Relationship between Nurse Staffing and Changes in Pain Level, Infection Severity, and Tissue Integrity: Skin and Mucous Membranes

  • Moon, Mi-Kyung
    • 재활간호학회지
    • /
    • 제14권1호
    • /
    • pp.62-69
    • /
    • 2011
  • Purpose: The study assessed whether nurse staffing was associated with 3 nursing sensitive outcomes used in intensive care unit (ICU) nursing care plans. Methods: This study was a retrospective and descriptive study using clinical data extracted from the data warehouse of a large acute care hospital in the Midwest. One-way analysis of variance was used to analyze the records of 578 ICU patients admitted from March 25 to May 31, 2010. Results: 79 Nursing Outcomes Classification (NOC) outcomes were used in the nursing care plans. The 3 most commonly used NOC outcomes (Pain Level, Infection Severity, and Tissue Integrity: Skin and Mucous Membranes) were analyzed to determine their relationship to nurse staffing. As a nurse staffing ratio, the skill mix of nursing caregivers ranged from 0.74 to 1 with an average of 0.90. This skill mix of nursing caregivers significantly differed among the changes in Infection Severity scores. However, the mean difference was only 0.02. Conclusion: The results did not support that greater nurse staffing was associated with better outcomes. More research is still needed to determine the usefulness of Pain Level, Infection Severity, and Tissue Integrity: Skin and Mucous Membranes in evaluating the impact of nurse staffing.

Evaluation of Robust Classifier Algorithm for Tissue Classification under Various Noise Levels

  • Youn, Su Hyun;Shin, Ki Young;Choi, Ahnryul;Mun, Joung Hwan
    • ETRI Journal
    • /
    • 제39권1호
    • /
    • pp.87-96
    • /
    • 2017
  • Ultrasonic surgical devices are routinely used for surgical procedures. The incision and coagulation of tissue generate a temperature of $40^{\circ}C-150^{\circ}C$ and depend on the controllable output power level of the surgical device. Recently, research on the classification of grasped tissues to automatically control the power level was published. However, this research did not consider the specific characteristics of the surgical device, tissue denaturalization, and so on. Therefore, this research proposes a robust algorithm that simulates noise to resemble real situations and classifies tissue using conventional classifier algorithms. In this research, the bioimpedance spectrum for six tissues (liver, large intestine, kidney, lung, muscle, and fat) is measured, and five classifier algorithms are used. A signal-to-noise ratio of additive white Gaussian noise diversifies the testing sets, and as a result, each classifier's performance exhibits a difference. The k-nearest neighbors algorithm shows the highest classification rate of 92.09% (p < 0.01) and a standard deviation of 1.92%, which confirms high reproducibility.

IMPACT OF IMMEDIATE AND NON-IMMEDIATE PROVISIONALIZATION ON THE SOFT TISSUE ESTHETICS OF FINAL RESTORATIONS ON IMMEDIATELY PLACED IMPLANTS

  • Han, Chong-Hyun;Paik, Jeong-Won;Lee, Keun-Woo;Han, Dong-Hoo;Chung, Moon-Kyu;Kim, Sun-Jai
    • 대한치과보철학회지
    • /
    • 제46권3호
    • /
    • pp.238-245
    • /
    • 2008
  • STATEMENT OF PROBLEM: Interpoximal papilla could be re-established without immeidate support with a provisional resotration following an immdiate implant placement. PURPOSE: Successful esthetic outcomes were reported utilizing immediate provisionalization following immediate implant placements. The aim of this study was to evaluate the soft tissue esthetics around immediately placed single tooth implant restorations with or without immediate provisional restorations. METHODS: A total of ten patients, who had a hopeless maxillary anterior tooth, were enrolled in this study. Screw retained provisional restorations were delivered to the randomly chosen 5 patients (immediate provisionalization group) on the day of immediate implant placement and maintained for about 5 months. For the remaining five patients (non-immediate provisionalization group), healing abutments were delivered on the day of surgery, replaced with screw retained provisional restorations approximately 3 months afterwards, and the provisional restorations were maintained for about 3 months. Digital photographs were taken at the delivery of final restorations in order to assess following variables; mesial papilla, distal papilla, soft tissue level, soft tissue contour and facial soft tissue prominence. The variables were compared to those of the contralateral natural tooth and scored by prosthodontists, periodontists, orthodontists and dental students. RESULTS: The immediate provisionalization group marked significantly higher scores on the following variables; soft tissue level and facial soft tissue prominence. In evaluating each variable, there were no notable differences in opinion between four dentist groups. CONCLUSION: Immediate provisionalization can be a treatment option to achieve superior soft tissue esthetics around immediately placed single implant restorations rather than non-immediate provisionalization approaches.

Immediate implant placement in conjunction with guided bone regeneration and/or connective tissue grafts: an experimental study in canines

  • Lim, Hyun-Chang;Paeng, Kyeong-Won;Kim, Myong Ji;Jung, Ronald E.;Hammerle, Christoph HF.;Jung, Ui-Won;Thoma, Daniel S.
    • Journal of Periodontal and Implant Science
    • /
    • 제52권2호
    • /
    • pp.170-180
    • /
    • 2022
  • Purpose: This study was conducted to assess the effect of hard and/or soft tissue grafting on immediate implants in a preclinical model. Methods: In 5 mongrel dogs, the distal roots of P2 and P3 were extracted from the maxilla (4 sites in each animal), and immediate implant placement was performed. Each site was randomly assigned to 1 of the following 4 groups: i) gap filling with guided bone regeneration (the GBR group), ii) subepithelial connective tissue grafting (the SCTG group), iii) GBR and SCTG (the GBR/SCTG group), and iv) no further treatment (control). Non-submerged healing was provided for 4 months. Histological and histomorphometric analyses were performed. Results: Peri-implant tissue height and thickness favored the SCTG group (height of periimplant mucosa: 1.14 mm; tissue thickness at the implant shoulder and ±1 mm from the shoulder: 1.14 mm, 0.78 mm, and 1.57 mm, respectively; median value) over the other groups. Bone grafting was not effective at the level of the implant shoulder and on the coronal level of the shoulder. In addition, simultaneous soft and hard tissue augmentation (the GBR/SCTG group) led to a less favorable tissue contour compared to GBR or SCTG alone (height of periimplant mucosa: 3.06 mm; thickness of peri-implant mucosa at the implant shoulder and ±1 mm from the shoulder: 0.72 mm, 0.3 mm, and 1.09 mm, respectively). Conclusion: SCTG tended to have positive effects on the thickness and height of the periimplant mucosa in immediate implant placement. However, simultaneous soft and hard tissue augmentation might not allow a satisfactory tissue contour in cases where the relationship between implant position and neighboring bone housing is unfavorable.

Neuronatin Is Associated with an Anti-Inflammatory Role in the White Adipose Tissue

  • Ka, Hye In;Han, Sora;Jeong, Ae Lee;Lee, Sunyi;Yong, Hyo Jeong;Boldbaatar, Ariundavaa;Joo, Hyun Jeong;Soh, Su Jung;Park, Ji Young;Lim, Jong-Seok;Lee, Myung Sok;Yang, Young
    • Journal of Microbiology and Biotechnology
    • /
    • 제27권6호
    • /
    • pp.1180-1188
    • /
    • 2017
  • Neuronatin (NNAT) is known to regulate ion channels during brain development and plays a role in maintaining the structure of the nervous system. A previous in silico analysis showed that Nnat was overexpressed in the adipose tissue of an obese rodent model relative to the wild type. Therefore, the aim of the present study was to investigate the function of Nnat in the adipose tissue. Because obesity is known to systemically induce low-grade inflammation, the Nnat expression level was examined in the adipose tissue obtained from C57BL/6 mice administered lipopolysaccharide (LPS). Unexpectedly, the Nnat expression level decreased in the white adipose tissue after LPS administration. To determine the role of NNAT in inflammation, 3T3-L1 cells overexpressing Nnat were treated with LPS. The level of the p65 subunit of nuclear factor-kappa B ($NF-{\kappa}B$) and the activity of $NF-{\kappa}B$ luciferase decreased following LPS treatment. These results indicate that NNAT plays an anti-inflammatory role in the adipose tissue.

Assessment of The Accuracy of The MR Abdominal Adipose Tissue Volumetry using 3D Gradient Dual Echo 2-Point DIXON Technique using CT as Reference

  • Kang, Sung-Jin
    • Journal of Magnetics
    • /
    • 제21권4호
    • /
    • pp.603-615
    • /
    • 2016
  • In this study, in order to determine the validity and accuracy of MR imaging of 3D gradient dual echo 2-point DIXON technique for measuring abdominal adipose tissue volume and distribution, the measurements obtained by CT were set as a reference for comparison and their correlations were evaluated. CT and MRI scans were performed on each subject (17 healthy male volunteers who were fully informed about this study) to measure abdominal adipose tissue volume. Two skilled investigators individually observed the images acquired by CT and MRI in an independent environment, and directly separated the total volume using region-based thresholding segmentation method, and based on this, the total adipose tissue volume, subcutaneous adipose tissue volume and visceral adipose tissue volume were respectively measured. The correlation of the adipose tissue volume measurements with respect to the observer was examined using the Spearman test and the inter-observer agreement was evaluated using the intra-class correlation test. The correlation of the adipose tissue volume measurements by CT and MRI imaging methods was examined by simple regression analysis. In addition, using the Bland-Altman plot, the degree of agreement between the two imaging methods was evaluated. All of the statistical analysis results showed highly statistically significant correlation (p<0.05) respectively from the results of each adipose tissue volume measurements. In conclusion, MR abdominal adipose volumetry using the technique of 3D gradient dual echo 2-point DIXON showed a very high level of concordance even when compared with the adipose tissue measuring method using CT as reference.

조직공학에서 생체역학의 역할 (The Role of Biomechanics in Tissue Engineering)

  • 박귀덕
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2008년도 추계학술대회A
    • /
    • pp.1458-1460
    • /
    • 2008
  • Tissue engineering is an interdisciplinary field that utilizes the principles of engineering and life sciences toward the creation of biological substitutes. Traditionally, major components of tissue engineering are cells, scaffolds, growth factors and recently biomechanical aspects have been given much attention. A large number of studies have reported that mechanical signals are of particular interest in either encouraging or inhibiting cellular responses. In tissue engineering, cell adhesion is a very important step, because quality of adhesion may determine a cell fate in the future. Elasticity of cell-adhesive substrate is found critical in regulating stem cell differentiation. Cells exert different contractile forces for cell migration, depending on substrate mechanics. Though tissue engineering is very interactive with diverse expertise, for a breakthrough, principles of biomechanics in tissue and cell level needs to be fully understood.

  • PDF

교원병에 동반된 단백소실장질환(Protein Losing Enteropathy)에서의 테크네슘표지 인혈청알부민 스캔 (Diagnosis of Protein Losing Enteropathy in Connective Tissue Diseases with $^{99m}Tc$-human Serum Albumin(HSA))

  • 원경숙;오영석;방신호;박원
    • 대한핵의학회지
    • /
    • 제27권1호
    • /
    • pp.88-97
    • /
    • 1993
  • Anterior abdominal scintigraphy after intravenous injection of $^{99m}Tc$-human serum albumin ($^{99m}Tc$-HSA 20 mCi) was done in 16 patients with connective tissue diseases and 15 healthy control patients. Patients with proteinuria or hepatopathy were excluded. 1) 7 (44%) patients among 16 connective tissue disease patients without the apparent evidence of external protein loss showed abnormal intestinal accumulation of albumin. 6 patients with positive albumin scintigraphy showed bypoalbuminemia. 2) There was no false positive scintigraphic finding in control group. 3) The serum albumin level in connective tissue disease patients ($3.1{\pm}0.6 g/dl$, n=16) was lower than control patients ($3.9{\pm}0.3 g/dl$, n=15) (p<0.0001). 4) The serum albumin level was lower in connective tissue disease patients with positive $^{99m}Tc$-HSA scan ($2.8{\pm}0.6 g/dl$, n=7) than the connective tissue disease patients with negative scan ($3.3{\pm}0.3 g/dl$, n=9) (p<0.05). 5) The hemoglobin level in connective tissue disease patients with positive nan ($10.6{\pm}2.91 g/dl$) was lower than that of the control group ($13.6{\pm}1.5 g/dl$) (p<0.05). Mypoalbuminemia is frequently involved in chronic connective tissue diseases. Protein losing enteropathy (PLE) is also responsible for the majority of the bypoalbuminemia in these patients. But it has been ignored because the conventional method for the diagnosis of PLE was difficult to perform. $^{99m}Tc$-HSA scan also must be validated by more extended study and comparison with the quantitative study such as stool ${\alpha}-1$ antitrypsin measurement. There must be a reevaluation of PLE in various diseases especially in connective tissue diseases with easy, fast, economical, and non-invasive method.

  • PDF