• 제목/요약/키워드: tip position

검색결과 372건 처리시간 0.026초

The effect of micro pore on the characteristics of crack tip plastic zone in concrete

  • Haeri, Hadi;Sarfarazi, V.
    • Computers and Concrete
    • /
    • 제17권1호
    • /
    • pp.107-127
    • /
    • 2016
  • Concrete is a heterogeneous material containing many weaknesses such as micro-cracks, pores and grain boundaries. The crack growth mechanism and failure behavior of concrete structures depend on the plastic deformation created by these weaknesses. In this article the non-linear finite element method is used to analyze the effect of presence of micro pore near a crack tip on both of the characteristics of crack tip plastic zone (its shape and size) and crack growth properties (such as crack growth length and crack initiation angle) under pure shear loading. The FE Code Franc2D/L is used to carry out these objectives. The effects of the crack-pore configurations and the spacing between micro pore and pre-excising crack tip on the characteristics of crack tip plastic zone and crack growth properties is highlighted. Based on the obtained results, the relative distance between the crack tip and the micro pore affects in very significant way the shape and the size of the crack tip plastic zone. Furthermore, crack growth length and crack initiation angle are mostly influenced by size and shape of plastic zone ahead of crack tip. Also the effects of pore decrease on the crack tip by variation of pore situation from linear to perpendicular configuration. The critical position for a micro pore is in front of the crack tip.

분무실 밀도 변화가 충돌 디젤분무 특성에 미치는 영향 (The Effect of Ambient Gas Density on the Development of Impinging Diesel Spray)

  • 김종현;이봉수;구자예
    • 한국분무공학회지
    • /
    • 제4권2호
    • /
    • pp.40-46
    • /
    • 1999
  • Experimental investigation of unsteady impinging diesel spray on the flat plate have been carried out using high speed camera and Malvern system. The density ratios of ambient gas to diesel fuel were varied using $N_2$ and Ar gas in the case of 14.9, 21.2, 28.4, 35.1, 40.4, and 50.1. With the increase of gas density ratio, the radial penetration is decreased due to the resistance of the ambient gas. With the increase of the gas density ratio and the distance between nozzle tip and flat plate, the height of spray is increased due to the entrance and circulation. With the increase of gas density ratio, SMD is decreased on the nearby position at the center of flat plate, but SMD is increased on the far position. As the distance between nozzle tip and flat plate is increased, SMD is always decreased.

  • PDF

Outcomes of Internal Fixation with Compression Hip Screws in Lateral Decubitus Position for Treatment of Femoral Intertrochanteric Fractures

  • Park, Cheon-Gon;Yoon, Taek-Rim;Park, Kyung-Soon
    • Hip & pelvis
    • /
    • 제30권4호
    • /
    • pp.254-259
    • /
    • 2018
  • Purpose: Internal fixation using compression hip screws (CHS) and traction tables placing patients in the supine position is a gold standard option for treating intertrochanteric fractures; however, at our institution, we approach this treatment with patients in a lateral decubitus position. Here, the results of 100 consecutive elderly (i.e., ${\geq}45$ years of age) patients who underwent internal fixation with CHS in lateral decubitus position are analyzed. Materials and Methods: Between March 2009 and May 2011, 100 consecutive elderly patients who underwent internal fixation with CHS for femoral intertrochanteric fracture were retrospectively reviewed. Clinical outcomes (i.e., Koval score, Harris hip score [HHS]) and radiographic outcomes (i.e., bone union time, amount of sliding of lag screw, tip-apex distance [TAD]) were evaluated. Results: Clinical assessments revealed that the average postoperative Koval score decreased from 1.4 to 2.6 (range, 0-5; P<0.05); HHS was 85 (range, 72-90); and mean bone union time was 5.0 (range, 2.0-8.2) months. Radiographic assessments revealed that anteroposterior average TAD was 6.95 (range, 1.27-14.63) mm; lateral average TAD was 7.26 (range, 1.20-18.43) mm; total average TAD was 14.21 (range, 2.47-28.66) mm; average lag screw sliding was 4.63 (range, 0-44.81) mm; and average angulation was varus $0.72^{\circ}$(range, $-7.6^{\circ}-12.7^{\circ}$). There were no cases of screw tip migration or nonunion, however, there were four cases of excessive screw sliding and six cases of varus angulation at more than $5^{\circ}$. Conclusion: CHS fixation in lateral decubitus position provides favorable clinical and radiological outcomes. This technique is advisable for regular CHS fixation of intertrochanteric fractures.

GMA용접에서 콘택트 팁 재질에 따른 용접특성 평가 (Evaluation of Gas Metal Arc Welding Characteristics according to Contact Tip Materials)

  • 김동윤;황인성;김동철;강문진
    • Journal of Welding and Joining
    • /
    • 제32권6호
    • /
    • pp.35-40
    • /
    • 2014
  • The contact tip for gas metal arc welding has important functions to transmit the welding current to the wire and to guide the wire to molten pool. If the contact tip is damaged, it is a cause of lowering the welding productivity due to removal of welding defects and replacement of contact tip. In case of the use of a contact tip for a long time the arc is unstable because the processed hole in the contact tip center is larger, and the variation of aiming position of the welding wire causes a seam tracking error. In this study, gas metal arc welding experiments using contact tip of three different materials were performed. The contact tips with Cu-P, Cu-Cr, and Cu-ODS were used at the experiments, and the welding characteristics by each contact tip were evaluated. After welding contact tip appearance, welding spatter adhesion amount of the nozzle, and weld bead appearance were evaluated. The welding current and welding voltage were measured to verify arc stability during arc welding.

플럭스 코어드 와이어에 따른 용접 중 콘택트 팁 내마모성 평가 (Wear Resistance Evaluation of Contact Tip according to Flux Cored Wire)

  • 김동윤;황인성;김동철;강문진
    • Journal of Welding and Joining
    • /
    • 제31권4호
    • /
    • pp.42-46
    • /
    • 2013
  • The contact tip for flux cored arc welding has important functions to transmit the welding current to the wire and to guide the wire to molten pool. A damaged contact tip causes a productivity reduction and a welding quality problem. In this study, the welding experiments for the wear resistance of contact tip regarding flux cored wire types were performed. With two fold type and a seamless type flux cored wires, the wear rates of contact tips were compared. In addition, the wear rate was checked according to the contact tip position.

Fe-Co-W 소결체와 탄소강의 레이저 용융부 결함형성에 미치는 공정변수의 영향 (The effect of welding parameters on the formation of discontinuities in the laser fusion zone between Fe-Co-W sintered segment and mild steel)

  • 김성욱;윤병현;정우광;이창희
    • 한국레이저가공학회지
    • /
    • 제7권3호
    • /
    • pp.25-36
    • /
    • 2004
  • This study was performed to clarification of the formation of weld discontinuities in the dissimilar laser fusion zone. Welding parameters were beam power of 1300, 1430, 1560, and 1700 W and travel speed of 1, 1.3, and 1.7 m/min. Most cavities in the fusion zone were observed near the tip. Cavities in the fusion zone observed to be formed and grown from pores in the tip. More cavities were formed as the beam position moves to the tip side. Small cavities were decreased but large cavities were increased when the energy input increased. W content in the fusion zone was increased with heat input and as the beam position close to the tip. In the fusion zone, W content in the dendrite boundary was increased with heat input. Considering the propagation path and fracture morphology, cracks were solidification cracking, and were initiated and propagated along the dendrite boundaries. The formation of cracks might be related with the W rich ${\mu}$ phase which was formed in the grain boundaries and dendrite boundaries.

  • PDF

유량에 따른 축류홴의 익단누설와류 특성 (Flow Characteristics of a Tip Leakage Vortex at Different Flow Rates in an Axial Flow Fan)

  • 장춘만;김광용
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2004년도 추계학술대회
    • /
    • pp.1383-1388
    • /
    • 2004
  • The flow characteristics in the blade passage of a low speed axial flow fan have been investigated by experimental analysis using a rotating hot-wire sensor for design and off-design operating conditions. The results show that the tip leakage vortex is moved upstream when flow rate is decreased, thus disturbing the formation of wake flow near the rotor tip. The tip leakage vortex interfaces with blade pressure surface, and results in high velocity fluctuation near the pressure surface. From the relative velocity distributions near the rotor tip, large axial velocity decay is observed at near stall condition, which results in large blockage compared to that at the design condition. Througout the flow measurements using a quasi-orthogonal measuring points to the tip leakage vortex, it is noted that the radial position of the tip leakage vortex is distributed between 94 and 96 percent span for all flow conditions. High spectrum density due to the large fluctuation of the tip leakage vortex is observed near the blade suction surface below the frequency of 1000 Hz at near stall condition.

  • PDF

유연한 단일링크 조작기의 적응진동제어 (Adaptive Vibration Control of Flexible One-Lind Manipulator)

  • 박영욱;김재원;박영필
    • 소음진동
    • /
    • 제5권3호
    • /
    • pp.385-394
    • /
    • 1995
  • Recently, since robot manipulator becomes faster and lighter, its link is no longer regarded as rigid body, and robot controller which only controls robot position cannot reduce vibration of the flexible link. Therefore vibration control is needed in robot manipulator control in addition to position control. In the case that tip mass changes when robot manipulator in working, it is clear that the efficiency of the vibration/position controller designed for the fixed system goes down. In this paper, the system with time varying parameters, adaptive control theory is adopted which estimates parameters changed by the variation of the tip mass and re-calculates the gain of the controller. Validify of the proposed adaptive controller and capability of the estimator are evaluated by computer simulations and experiments. Comparison results of the optimal controller for the fixed system and proposed adaptive controller and carried out.

  • PDF

POSITION CONTROL OF A FLEXIBLE ROBOT ARM UNDER IMPULSIVE LOADING THE TIP

  • Chonan, Seiji;Yuki, Yasuhiro
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1990년도 한국자동제어학술회의논문집(국제학술편); KOEX, Seoul; 26-27 Oct. 1990
    • /
    • pp.896-901
    • /
    • 1990
  • A simulation analysis is presented for the position control of a single-link flexible manipulator whose end-effector is subjected to an impulsive force. Arm is rotated by a d.c. servomotor at the shoulder so that the end point stays precisely at its initial position even if the end effector is thumped with the impulsive loading. A gap sensor is used to measure the tip displacement. The control torque based on the PD control law is applied to the motor through the driver circuit. The control strategy is tested by means of computer simulation for the one-link flexible-arm prototype in the authers' laboratory at Tohoku Univ.

  • PDF

Coping design에 따른 도재전장관의 파절강도에 관한 연구 (THE FRACTURE RESISTANCE OF CERAMOMETAL CROWN WITH VARIOUS COPING DESIGN)

  • 정완모;동진근;진태호
    • 대한치과보철학회지
    • /
    • 제30권1호
    • /
    • pp.125-132
    • /
    • 1992
  • The purpose of this study was to evaluate the effect of the metal coping design on the fracture resistance of ceramometal crown. The Ni-Cr alloy(Supranium, Krupp Co., German) and Vaccm-fired porcelain powder(Vita VMK 689, Vita Co., Germany) were used in this study. The measurement of fracture resisitance of ceramometal crown was done with Instron Universial Testing Machine(Instro Co., Model no.4201). The obained results were as fellows : 1. The fracture resistance measured at the buccal cusp tip was the highest value in the group that those position of ceramometal junction was 2mm superior to the lingual finshing margin(100.25Kg) and the fracture resistance revealed on order of the group that those position was 2mm buccal to the central groove(51.64Kg). 2. The fracture resistance measured at the central groove was higher value in the group that those position was 2mm lingual to the central groove than in the group that those position was 2mm lingual to the central groove than in the group that those position was 2mm superior to lingual finishing margin(132.48Kg). 3. In all cases, the fracture resistance at the central groove was higher than that at the buccal cusp tip.

  • PDF