• 제목/요약/키워드: times

검색결과 70,834건 처리시간 0.071초

한강유역의 수중미생물 오염도 조사 (Bacteriological Contamination of Water in Han River basin)

  • 최한영;박정오
    • 환경위생공학
    • /
    • 제4권2호
    • /
    • pp.47-59
    • /
    • 1989
  • In order to investigate the bacteriological contamination of water in Han river, the survey was carried out in eight reservoirs of Seoul water supply during the period from January to December in 1985. 1. The counts by means of total bacteria in eight reservoirs by standard plate count method were as follows: $7.7\times10^2$ per ml in Paldang reservior, $9.6\times10^3$ per ml in Gueiri, $8.4\times10^4$ per ml in Doogdo, $1.6\times10^6$ per ml in Bogwang, $2.5\times10^6$ per ml in Noryangjin, $2.2\times10^6$per ml in Seon yoo, $5.9\times10^6$ per ml in Yungdeungpo and $1.9\times10^7$per ml in Gayang. 2. The average counts of total coliform in eight reservoirs by MPN method were as follows : $2.4\times10$ per 100 ml in Paldang, $5.6\times10^2$ per 100 ml in Gueiri, $2.3\times10^3$ per 100 ml in Doogdo, $5.1\times10^4$ per 100 ml in Noryang-jin, $1.2\times10^5$ per 100 ml in Bogwang, $6.2\times10^4$ per 100 ml in Seonyoo, $1.1\times10^5$ per 100 ml in Yungdeungpo and $2.8\times10^5$ per 100 ml Gayang. 3. The counts by means of fecal coliform in eight reservoirs by MPN method were as follows : non detection per 100 ml in Paldang, 5.2 per 100 ml in Gueiri, $1.2\times10^2$ per 100 ml in Doogdo, $1.6\times10^3$ per 100ml in Bogwang, $2.0\times10^3$per 100ml in Noryangjin, $6.6\times10^2$ per 100ml in Seonyoo, $1.2\times10^3$ per 100 ml in Yungdeungpo and $2.5\times10^3$per 100 ml in Gayang. 4. The counts by means of fecal streptococci in eight reservoirs by MPN method were as follows: non detection per 100 ml in Paldang and Gueiri, $6.9\times10$ per 100 ml in Doogdo, $3.2\times10^2$ 102 per 100 ml in Bogwang, $2.9\times10^2$ per 100 ml in Noryangjin, $3.0\times10^2$ per 100 ml in Seonyoo, $4.0\times10^2$ per 100 ml in Yungdeungpo and $14\times10^3$ per 100 ml in Gayang. 5. The counts means of pseudomonas aeruginosa in eight reservoirs by MPN method were as follows; non detection per 100 ml in Paldang, 2.4 per 100 ml in Gueiri, $1.5\times10$ per 100 ml in Doogdo, $2.0\times10$ per 100ml in Bogwang,$6.2\times10$ per 100mI in Noryangjin, $2.1\times10$ per 100ml in Seonyoo, $6.4\times10$ per 100mI in Yungdeungpo and $7.1\times10$ per 100ml in Gaynag.

  • PDF

H.264/AVC 디코더를 위한 효율적인 인터 예측 하드웨어 구조 설계 (An Efficient Inter-Prediction Hardware Design for the H.264/AVC Decoder)

  • 김선철;류광기
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국해양정보통신학회 2009년도 춘계학술대회
    • /
    • pp.112-115
    • /
    • 2009
  • 본 논문에서는 H.264/AVC 베이스라인 프로파일 가운데서 병목현상을 일으키는 주요한 부분인 인터 예측의 효율적인 하드웨어 구조에 관한 설계에 대해 기술한다. H.264/AVC 디코더는 $16{\times}16$, $16{\times}8$, $8{\times}16$, $8{\times}8$, $8{\times}4$, $4{\times}8$, $4{\times}4$ 등 다양한 블록 모드를 지원하는데 레퍼런스 소프트웨어(JM)에서는 중복 픽셀에 대해 제거 하지 않고 항상 $4{\times}4$ 블록에 대한 $9{\times}9$ 참조 블록을 패취하게 된다. 기존에 이미 설계된 디자인에서는 이러한 문제를 해결하기 위하여 $8{\times}8$ 블록 모드와 $4{\times}4$ 블록 모드를 고려하여 설계하였다. 블록 모드가 $8{\times}8$ 사이즈보다 크거나 같을 경우 여러 개의 $8{\times}8$ 블록으로 나뉘어서 그에 대한 $13{\times}13$ 레퍼런스 블록을 패취하고 $8{\times}8$ 블록 보다 작을 경우 여러 개의 $4{\times}4$ 블록으로 나뉘어서 그에 대한 $9{\times}9$ 레퍼런스 블록을 패취하는 방법을 사용하여 중복픽셀을 제거 하여 패취 사이클을 줄였다. 본 논문에서는 더 큰 성능 향상을 위하여 $8{\times}8$$4{\times}4$ 블록 모드뿐만이 아닌 다양한 블록 모드에 대한 레퍼런스 블록 패취를 진행하여 더 많은 중복픽셀을 제거 하였고 메모리 패취 사이클을 줄여 최대 18.6%의 참조 블록 패취 사이클 감소를 가져 왔다.

  • PDF

살균시유(殺菌市乳)의 세균오염원(細菌汚染源)에 관한 연구(硏究) (Studies on the Sources of Bacterial Contamination in U. H. T. Processed Milk)

  • 김종우
    • 농업과학연구
    • /
    • 제7권2호
    • /
    • pp.103-108
    • /
    • 1980
  • U. H. T. 처리우유(處理牛乳)의 처리공정별(處理工程別) 세균함유수(細菌含有數)를 추적하므로서 살균시유(殺菌市乳)의 세균오염원(細菌汚染源)을 확인(確認)하고 보다 위생적(衛生的)인 시유(市乳)의 생산방법(生産方法)을 검토(檢討)코자 U. H. T. 시유(市乳) 치리장(處理場)에서 각(各) 공정(工程) 처리유(處理乳) 및 용기(容器), 공기(空氣), 처리수등(處理水等)이 함유(含有)하고 있는 중온성균(中溫性菌), 호열성균(好熱性菌), 호냉성균(好冷性菌) 및 대장균등(大腸菌等)의 소장(消長)을 시험(試驗)하여 다음과 같은 결과(結果)를 얻었다. 1. U. H. T. 처리중(處理中) 저유(貯乳) tank로부터 예열전(豫熱前) pipe line까지의 우유중(牛乳中)에는 $1.2{\times}10^7{\sim}1.9{\times}10^7/ml$의 중온성균수(中溫性菌數)를 나타내고 있으나 예열(豫熱) 및 균질과정(均質過程)에서 $7.0{\times}10{\sim}3.4{\times}10^2/ml$로 감소(減少)되었고, 균과정(殺菌過程)에서 $1.0{\times}10/ml$ 이하로 격감되었으며 포장과정(包裝過程)에서는 $1.0{\times}10{\sim}1.2{\times}10^2/ml$로 균수(菌數)의 증가(增加)를 나타내었다. 2. 호열성균(好熱性菌)은 저유(貯乳) tank로 부터 예열전(豫熱前) 우유(牛乳)까지 $5.0{\times}10{\sim}1.0{\times}10^2/ml$의 균수(菌數) 나타내었으나 예열(豫熱) 및 균질과정(均質過程)에서는 $3.0{\times}10{\sim}5.0{\times}10/ml$의 균수(菌數)를, 살균기(殺菌機) 및 surge tank에서는 균수(菌數)를 나타내지 않았으며 포장후(包裝後)에는 $1.0{\times}10{\sim}3.0{\times}10/ml$의 적은 균수(菌數)를 표시(表示)하였다. 3. 호냉성균(好冷性菌)에 있어서는 저유(貯乳) tank로 부터 예열전(豫熱前) 우유(牛乳)까지 $1.0{\times}10^6{\sim}3.7{\times}10^6/ml$의 균수(菌數)를 나타냈으나 예열(豫熱)과 균질과정(均質過程)을 거쳐 $1.0{\times}10{\sim}4.0{\times}10/ml$으로 감소(減少)되었고 살균후(殺菌後)에는 $1.0{\times}10/ml$로 감소(減少)되었다가 포장후(包裝後)에는 $2.0{\times}10{\sim}2.5{\times}10^2$ 까지 증가(增加)되었다. 4. 대장균(大腸園)에 있어서는 예열전(豫熱前)까지 $2.1{\times}10^4{\sim}6.5{\times}10^5/ml$의 균수(菌數)를 나타냈으나 가열처리(加熟處理) 이후(以後)에는 균수(菌數)를 나타내지 않았다. 5. 포장용기(包裝容器), 처리실(處理室) 공기(空氣) 및 처리수(處理水)에 대한 세균(細菌)의 함량조사결과(含量調査結果)에서는 공기(空氣), 처리수(處理水) 및 포장병(包裝甁)에서 $3.0{\times}10{\sim}7.4{\times}10^2$의 중온성균(中溫性菌)을, 공기(空氣)와 세척수(洗滌水)에서 $1.0{\times}10{\sim}3.0{\times}10$의 호열성균(好熱性菌)을, 공기(空氣), 세척수(洗滌水) 및 포장용기등(包裝容器等)에서 $1.0{\times}10{\sim}1.0{\times}10^2$의 호냉성균(好冷性菌)을 발견(發見)할 수 있었고 대장균(大腸菌)은 검출(檢出)되지 않았다.

  • PDF

피보험체계측치(被保險體計測値)의 평가(評價)에 관한 연구(硏究) 제3보(第3報) 한국성인(韓國成人)의 표준체중(標準休重) 산출(算出)을 위한 변형(變形)Broca지수(指數)에 관한 연구(硏究) (A Study on the Rating of the Insureds' Anthropometric Data III. A study on the Modified Broca's Index to Estimate Standard Body Weight of Korean Adults)

  • 임영훈
    • 보험의학회지
    • /
    • 제4권1호
    • /
    • pp.44-76
    • /
    • 1987
  • Present study was undertaken to establish the modified Broca's indices to estimate standard body weight by using a total of 5,496 insured persons who were medically examined at the Honam Medical Room of Dong Bang Life Insurance Company Ltd. from January, 1983 to January, 1986. The results were as follows: 1. The linear regression equations of body weight to $height^3$ to estimate standard body weight were as follows: In male, for $18{\sim}19$ age group $y=7.272{\times}10^{-6}{\times}x^3+23.560$ for $20{\sim}29$ age group $y=8.187{\times}10^{-6}{\times}x^3+22.031$ for $30{\sim}39$ age group $y=8.627{\times}10^{-6}{\times}x^3+23.169$ for $40{\sim}49$ age group $y=9.561{\times}10^{-6}{\times}x^3+20.994$ for $50{\sim}59$ age group $y=8.604{\times}10^{-6}{\times}x^3+23.081$ and for all ages group $y=7.778{\times}10^{-6}{\times}x^3+25.929$ In female, for $18{\sim}19$ age group $y=8.252{\times}10^{-6}{\times}x^3+18.920$ for $20{\sim}29$ age group $y=7.715{\times}10^{-6}{\times}x^3+22.409$ for $30{\sim}39$ age group $y=8.808{\times}10^{-6}{\times}x^3+21.440$ for $40{\sim}49$ age group $y=9.691{\times}10^{-6}{\times}x^3+21.940$ for $50{\sim}59$ age group $y=12.550{\times}10^{-6}{\times}x^3+11.031$ and for all ages group $y=7.300{\times}10^{-6}{\times}x^3+26.601$ In both sexes, for all ages group $y=8.342{\times}10^{-6}{\times}x^3+22.998$ 2. The modified Broca's index is expressed by formula $\{height(cm)-100\}{\times}K(kg)$. K is obtained from the following formula standard weight to average height estimated $\frac{by\;means\;of\;linear\;regression\;equation(kg)}{\{Average\;height(cm)-100\}{\times}K(kg)}$=1 Author's modified Broca's indices are as follows: In male, for $18{\sim}19$ age group $\{height(cm)-100\}{\times}0.85(kg)$ for $20{\sim}29$ age group $\{height(cm)-100\}{\times}0.90(kg)$ for $30{\sim}39$ age group $\{height(cm)-100\}{\times}0.95(kg)$ for $40{\sim}49$ age group $\{height(cm)-100\}{\times}1.00(kg)$ for $50{\sim}59$ age group $\{height(cm)-100\}{\times}0.95(kg)$ and for all ages group $\{height(cm)-100\}{\times}0.95(kg)$ In female, for $18{\sim}19$ age group $\{height(cm)-100\}{\times}0.90(kg)$ for $20{\sim}29$ age group $\{height(cm)-100\}{\times}0.90(kg)$ for $30{\sim}39$ age group $\{height(cm)-100\}{\times}1.00(kg)$ for $40{\sim}49$ age group $\{height(cm)-100\}{\times}1.05(kg)$ for $50{\sim}59$ age group $\{height(cm)-100\}{\times}1.05(kg)$ and for all ages group $\{height(cm)-100\}{\times}1.00(kg)$ In both sexes, for all age group $\{height(cm)-100\}{\times}0.95(kg)$ 3. Several types of modified Broca's index recommended by author are as follows: I. In male, for $18{\sim}29$ age group $\{height(cm)-100\}{\times}0.90(kg)$ and for $30{\sim}59$ age group $\{height(cm)-100\}{\times}0.95(kg)$ In female, for $18{\sim}29$ age group $\{height(cm)-100\}{\times}0.90(kg)$ and for $30{\sim}39$ age group $\{height(cm)-100\}{\times}1.00(kg)$ II. In male, for all ages group $\{height(cm)-100\}{\times}0.95(kg)$ In female, for all ages group $\{height(cm)-100\}{\times}1.00(kg)$ III. In both sexes, for all ages group $\{height(cm)-100\}{\times}0.95(kg)$ Note: The first type of modified Broca's index is the most precise one in estimating standard body weight among several types established by author. 4. Error of estimated standard body weight appearing by applying modified Broca's indices is generally greater in short build persons than in tall build persons and is more dominant especially in female group.

  • PDF

수영만 양식 미역, 모자반 및 환경해수의 수은, 카드뮴, 납, 구리의 농도에 대하여 (CONCENTRATIONS OF MERCURY, CADMIUM, LEAD AND CUPPER IN THE SURROUNDING SEAWATER AND IN SEAWEEDS, UNDARIA PINNNATIFIDA AND SARGASSUM FULVELLUM, FROM SUYEONG BAY IN BUSAN)

  • 김장양;원중훈
    • 한국수산과학회지
    • /
    • 제7권3호
    • /
    • pp.169-178
    • /
    • 1974
  • 1. 수영만내 미역 양식장외 환경해수와 미역 및 모자반의 수은 카드뮴 납 및 구리의 농도를 측정하였다. 2. 환경해수의 수은농도는 $0.00\~0.39ppb$에 평균이 0.16 ppb, 카드뮴은 $0.00\~0.46ppb$에 평균이 0.18ppb, 납은 $0.00\~0.94ppb$에 평균이 0.26 ppb, 주리는 $0.00\~0.86ppb$에 평균이 0.25 ppb였다. 3. 수영만해수의 중금속 농도는 물때에 따라 약간의 차가 생긴다. 4. 미역의 수은농도는 풍건물로서 $0.02\~0.48ppm$에 평균 0.07 ppm근 농축계수는 $0.13\times10^3\~1.0\times10^3$에 평균이 $0.42\times10^3$이다. 카드뮴의 농도는 $0.14\~3.2ppm$에 평균이 0.37 ppm고, 농축계수는 $0.8\times10^3\~4.9\times10^3$에 평균이 $2.1\times10^3$이다. 납은 $0.8\~5.0ppm$에 2.3 ppm, 농축계수는 $3.1\times10^3\~19\times10^3$에 평균이 $8.9\times10^3$이다. 구리는 $1.4\~6.9ppm$에 평균이 3.7 ppm고, 농축계수는 $6.0\times10^3\~28\times10^3$에 평균이 $15\times10^3$이다. 5, 미역의 중금속농도는 체장과는 뚜렷한 상관성이 보이지 않는다. 그러나 귀 부분이 엽체부보다 큰 차는 없지만 대체로는 낮은 경향이다. 6, 모자반의 수은농도 및 농축계수는 풍건물로서 $0.01\~0.09ppm$ 및 0.04 ppm에 $0.06\times10^3\~0.56\times10^3$$0.25\times10^3$, 카드뮴은 $0.11\~0.31ppm$ 및 0.18 ppm에 $0.61\times10^3\~1.7\times10^3$$1.0\times10^3$이고, 납은 $0.8\~2.2ppm$ 및 1.4 ppm에 $3.1\times10^3\~8.5\times10^3$$5.4\times10^3$, 구리는 $3.6\~13.1ppm$ 및 5.7 ppm에 $14.4\times10^3\~52.4\times10^3$$22.8\times10^3$이다. 7, 미역의 수은 카드뮴 및 납의 농축계수는 모자반의 약 3배가되고 구리의 그것은 오히려 모자반이 크다. (이 연구는 1973년도 문교부 연구조성비로 되었으며, 시료를 제공해 주신 해운대 김경재씨에 감사드립니다)

  • PDF

곱셈기를 재사용하는 16×16 HEVC 코어 역변환기 설계 (16×16 HEVC Inverse Core Transform Architecture Using Multiplier Reuse)

  • 이종배;이성수
    • 전기전자학회논문지
    • /
    • 제19권3호
    • /
    • pp.378-384
    • /
    • 2015
  • 기존의 HEVC 코어 역변환기에서는 동일한 시간에 동일한 수의 화소를 처리하기 위해서 $2n{\times}2n$ 역변환기에 여분의 $n{\times}n$ 역변환기를 추가하여 한 개의 $2n{\times}2n$ 역변환기 또는 두 개의 $n{\times}n$ 역변환기로 동작하게 하였으나 여분의 $n{\times}n$ 역변환기 때문에 하드웨어 크기가 증가하는 단점이 있다. 이러한 문제점을 해결하기 위해 곱셈기를 재사용하여 여분의 $4{\times}4$ 역변환기를 없앤 새로운 $8{\times}8$ HEVC 코어 역변환기 구조가 제안되었으며, 본 논문에서는 이를 확장한 $16{\times}16$ HEVC 코어 역변환기 구조를 제안한다. 제안하는 $16{\times}16$ HEVC 역변환기는 $4{\times}4$ 역변환, $8{\times}8$ 코어 역 변환, $16{\times}16$ 코어 역변환에서 프레임 처리 시간이 모두 동일하며, 여분의 역변환기를 사용하는 아키텍쳐에 비해 게이트 수를 13% 줄일 수 있다.

생물학적 동등성 시험을 위한 2×k 교차설계법의 통계적 고려 (Some Statistical Considerations on 2×k Crossover Designs for Bioequivalence Trial)

  • 노소영;박상규
    • 응용통계연구
    • /
    • 제26권4호
    • /
    • pp.675-686
    • /
    • 2013
  • 현재 우리나라 식품의약품안전청에서는 $2{\times}2$ 교차설계법을 기초로 제제간의 생물학적 동등성 평가를 수행하도록 규정하고 있다. 하지만 고변동성 제제의 생물학적 동등성 평가에서 $2{\times}2$ 교차설계법에 의한 시험은 지나치게 많은 피험자를 필요로 할 수 있어 윤리적이고 경제적인 고려가 필요하다는 논의가 이루어지고 있다. $2{\times}2$ 교차설계법을 대체할 수 있는 대안으로 $2{\times}4$ 교차설계법은 미국 및 유럽 등에서는 생물학적 동등성 평가에 광범위하게 사용되는 설계 방법이고, $2{\times}3$ 교차설계법도 $2{\times}2$$2{\times}4$ 교차설계법의 단점을 개선할 수 있는 효율적인 대안으로 관심이 많다. 본 연구에서는 $2{\times}4$$2{\times}3$ 교차설계법의 통계적 모형과 제시된 통계적 모형에 연계된 분산분석표를 유도한다. 현행 국내 생물학적 동등성 시험 규정에 의하면 $2{\times}4$$2{\times}3$ 교차설계법의 분산분석표는 반드시 제시되어야 하지만 아직 문헌상에 존재하지 않아 관련 연구에 기여할 것으로 생각된다. 또한 $2{\times}4$$2{\times}3$ 교차설계법에 기초한 피험자 계산을 $2{\times}2$ 교차설계법과 비교 제시하여 고변동성 제제의 생물학적 동등성 시험 연구에 적절한 시험 설계 선택에 정보를 제공한다.

TU 블록 크기에 따른 CNN기반 인루프필터 (CNN-based In-loop Filter on TU Block)

  • 김양우;정세윤;조승현;이영렬
    • 한국방송∙미디어공학회:학술대회논문집
    • /
    • 한국방송∙미디어공학회 2018년도 추계학술대회
    • /
    • pp.15-17
    • /
    • 2018
  • VVC(Versatile Video Coding)는 입력된 영상을 CTU(Coding Tree Unit) 단위로 분할하여 코딩하며, 이를 다시 QTBTT(Quadtree plus binary tree and triple tree)로 분할하고, TU(Transform Unit)도 이와 같은 단위로 분할된다. 따라서 TU의 크기는 $4{\times}4$, $4{\times}8$, $4{\times}16$, $4{\times}32$, $8{\times}4$, $16{\times}4$, $32{\times}4$, $8{\times}8$, $8{\times}16$, $8{\times}32$, $16{\times}8$, $32{\times}8$, $16{\times}16$, $16{\times}32$, $32{\times}16$, $32{\times}32$, $64{\times}64$의 17가지 종류가 있다. 기존의 VVC 참조 Software인 VTM에서는 디블록킹필터와 SAO(Sample Adaptive Offset)로 이루어진 인루프필터를 이용하여 에러를 복원하는데, 본 논문은 TU 크기에 따라서 원본블록과 복원블록의 차이(에러)가 통계적으로 다름을 이용하여 서로 다른 CNN(Convolution Neural Network)을 구축하고 에러를 복원하는 방법으로 VTM의 인루프 필터를 대체한다. 복원영상의 에러를 감소시키기 위하여 TU 블록크기에 따라 DenseNet의 Dense Block기반 CNN을 구성하고, Hyper Parameter와 복잡도의 감소를 위해 네트워크 간에 일부 가중치를 공유하는 모양의 Network를 구성하였다.

  • PDF

스마트 폰 터치스크린에서의 작은 터치 키의 사용성 연구 (Usability Evaluation of the Size of Small Touch Keys for the Smart Phone)

  • 김보람;김태일;임영재;정의승
    • 대한산업공학회지
    • /
    • 제38권2호
    • /
    • pp.80-88
    • /
    • 2012
  • This paper focuses on small touch key size and spacing that affect the usability of the smart phones. The experiments examined thirty-six different touch key designs, combinations of four touch key sizes (width (mm) ${\times}$height (mm); $4{\times}4$, $4{\times}7$, $7{\times}4$, and $7{\times}7$), and nine spacings (horizontal (mm)${\times}$vertical (mm); $0{\times}0$, $0{\times}1$, $0{\times}3$, $1{\times}0$, $1{\times}1$, $1{\times}3$, $3{\times}0$, $3{\times}1$, and $3{\times}3$). Forty participants volunteered in the experiment. The completion time, error rate, identification discomfort, and control discomfort were measured. The results revealed that the touch key sizes of $7{\times}7$ and $7{\times}4$ provide the best performance in terms of the error rate measure, while the touch key size of $7{\times}7$ provides the best results for other measures. In addition, touch key spacings of $1{\times}1$, $1{\times}3$ and $3{\times}1$ are regarded as the best for all the measures. The results of this study suggest a practical approach for the small touch key design for the smart phones.