• Title/Summary/Keyword: timer

Search Result 380, Processing Time 0.026 seconds

Design and Assessment of a Watch Dog Timer for Safety Improvement of an Embedded Railway Signal Controller (철도신호 내장형제어기 안전성 향상을 위한 워치독타이머 설계 및 평가)

  • Shin, Duc-Ko;Lee, Kang-Mi;Lee, Jae-Ho;Kim, Yong-Kyu
    • Journal of the Korean Society for Railway
    • /
    • v.10 no.6
    • /
    • pp.730-734
    • /
    • 2007
  • In this paper, we suggest the criticality of Hidden Failure with regard to the design of watch dog timer, used to detect HALT on railway signaling embedded controller, via FMEA and FTA. Hidden Failure means reliability and safety degradation of the system due to any failure occurred on elements added for fault tolerance. In this paper, therefore, we design vital watch dog timer to prevent the system from operating in low SIL conditions and assess the safety of circuit on failure occurrence to demonstrate that safety degradation problems owing to existing design are supplemented.

A Study on the Actual Conditions of Indoor Air Quality of Underground Dwellings and the Automatic Ventilating Fan Operated by CO2 Controller and Timer (지하주거의 실내공기환경 실태조사와 CO2 조절기 및 타이머에 의한 환기팬 자동운전에 관한 연구)

  • Kwon, Young Cheol;Park, Jin Chul
    • KIEAE Journal
    • /
    • v.8 no.4
    • /
    • pp.3-9
    • /
    • 2008
  • The rapid urbanization after 1970s caused the shortage of dwellings in urban areas. As the result, the underground dwellings were developed to compensate for the insufficient dwelling spaces. While the underground dwellings have some advantage in the respect of thermal and acoustic environment, they usually have the basic problems in the indoor air quality because of the lack of natural ventilation through small window areas. The purpose of this study is to investigate and to improve the indoor air quality of underground dwellings. Thirty Units in Seoul and Gyung-Gi Province were investigated into the indoor environmental conditions. For the purpose of the improvement of their indoor air quality, Automatically-operated ventilating fan was installed in a sample unit which has worst indoor environmental condition. Then the indoor air quality was monitored when it was operated by $CO_2$ control system and timer. Finally economic feasibility study was made considering the effect of the improvement of indoor air quality. The extra cost for installing timer could be paid back only in 10 months, so timer-installed automatic fan is recommended to improve the indoor air quality of underground dwellings.

A Study on the Implementation of the High Speed Timer for SAW Device (SAW용 고속 타이머 구현에 대한 연구)

  • Kim, Ok-Soo;Kim, Young-kil
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.13 no.5
    • /
    • pp.1030-1037
    • /
    • 2009
  • SAW Sensor is greatly developed today and Reader Platform which uses SAW Sensor for temperature or pressure is required to use TDS method for low power and high speed processing. For to use this Platform, high speed timer is required to measure a short interval between reference signal and reflectior's signal. This paper proposes that platform receive SAW Sensor's signals and transform digital signal through comparator. Next the transformed signal is measured by Timer Platform and the measured interval is displayed with time. This paper proposes method of measurment of time with nano sec unit.

Performance Analysis of Multiplexing Gain over Timer_CU in AAL2 on UMTS Network (UMTS망의 AAL2에서 Timer_CU에 따른 다중화 이득 성능분석)

  • 이현진;김재현
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.41 no.8
    • /
    • pp.35-43
    • /
    • 2004
  • An AAL2 transmission scheme is used to deliver voice and data traffic between Node-B and RNC on 3G WCDMA network. To predict performance of AAL2 multiplexing precisely, we derived analytically bandwidth gain and cell packing density using discrete-time Markov chain model for voice service and validated these results with simulation. We also performed detailed simulation for AAL2 multiplexing in a concentrator. Based on the analytical result, we propose the engineering guideline to select the optimal Timer_CU in a Node-B. We found that there is no major benefit of additional AAL2 multiplexing in a concentrator and the benefit of AAL2 switching in tub for data services is much less than that for voice service.

Internet Based Remote Control and Monitoring System using Digital Timer (디지털 타이머를 이용한 인터넷 기반의 원격제어 및 모니터링)

  • Kim, E.J.;Kang, S.Y.;Bark, C.S.;Lim, Y.C.;Kim, G.W.
    • Proceedings of the KIEE Conference
    • /
    • 2001.10a
    • /
    • pp.245-248
    • /
    • 2001
  • Recently, with the advancement of internet network the system has been needed to be controllable and observable through internet at industrial workplace. In this study, we developed the digital timer which has a communication function to control and observe many kinds of devices by combining relay and timer used for each type of control panel to realize control solution based on internet to be easily applicable at workplace with low cost and adding 485 serial communication module to have parallel expansibility and safety. And, this system was experimented and designed for easy system management and status check from remote station through internet. appling the developed digital timer to parallel sequence control of motor. As the result of experiment, the circuit configuration would be more simplified than the existing, and it is expected that multi-connection control and monitoring can be simply implemented with low cost equipment at industrial workplace.

  • PDF

A Design and Implementation of Store Management Application using Beacon (비콘을 이용한 매장관리 모바일 어플리케이션 설계 및 구현)

  • Moon, Gabin;Jeon, Seonghee;Kim, Sungrim
    • Journal of Korea Society of Digital Industry and Information Management
    • /
    • v.14 no.2
    • /
    • pp.1-9
    • /
    • 2018
  • Currently, the record of part-timer is mainly written in handwriting or using excel work schedule, paper work recorder, and time attendance program using POS program. And, work table, commute records, paycheck are managed separately. Time-attendance information is not linked and is managed separately, and payment of wages is often not done accurately. And, it is difficult to pay the wages because it is not able to accurately grasp the state of attendance of part-timer. Therefore, it is necessary to have a transparent wage and work management system based on the trust between the owner and the part-timer. In this paper, we design a system that can perform real-time commute check using beacon, transparent wage management, wage calculation by automatic calculation, and smooth communication between owner and the part-timer. We have also implemented a store management mobile application using Android Studio 2.3, Eclipse, Android 5.1 and Beacon devices in a MySQL environment.

Internet Based Remote Control and Monitoring System using Digital Timer (디지털 타이머를 이용한 인터넷 기반의 원격제어 및 모니터링)

  • Kim, E.J.;Kang, S.Y.;Bark, C.S.;Lim, Y.C.;Kim, G.W.
    • Proceedings of the KIEE Conference
    • /
    • 2001.10a
    • /
    • pp.157-160
    • /
    • 2001
  • Recently, with the advancement of internet network the system has been needed to be controllable and observable through internet at industrial workplace. In this study, we developed the digital timer which has a communication function to control and observe many kinds of devices by combining relay and timer used for each type of control panel to realize control solution based on internet to be easily applicable at workplace with low cost and adding 485 serial communication module to have parallel expansibility and safety. And, this system was experimented and designed for easy system management and status check from remote station through internet, appling the developed digital timer to parallel sequence control of motor. As the result of experiment, the circuit configuration would be more simplified than the existing, and it is expected that multi-connection control and monitoring can be simply implemented with low cost equipment at industrial workplace.

  • PDF

VASI RTC of MCM-ERC32 Processor and It's Application to On-Board Time Management (MCM-ERC32 Processor 의 VASI RTC 기능 및 위성 고유 시간 운영에의 적용)

  • Yang, Seung-Eun;Lee, Jae-Seung;Choi, Jong-Wook;Cheon, Yee-Jin
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2010.11a
    • /
    • pp.852-854
    • /
    • 2010
  • MCM-ERC32 는 우주 환경에서 동작하는 시스템에 사용할 목적으로 유럽에서 개발된 집약 프로세서 모듈이다. MCM (Multi Chip Module)은 크게 ERC32 single chip 과 VASI (Very Advanced Sparc Interface) 및 6MByte 의 SRAM, 32MByte 의 DRAM 으로 구성되어 있다. VASI 의 경우 각종 I/O 처리 및 timer 의 기능을 수행하며 특히 VASI RTC 의 경우 VASI cycle, slot 을 이용하여 다양한 형태의 timer 구현이 가능하다. Timer 의 경우 각종 태스크의 관리와 스케줄링에 사용되는 가장 기본적이며 매우 중요한 요소이다. 위성의 고유 시간 역시 timer 를 활용하여 설계하게 되는데 이 부분이 잘 구현 되어야 정확한 임무 수행 및 위성의 제어가 가능하다. 본 논문에서는 VASI RTC 의 구조와 기능에 대해 설명하고 이를 위성의 고유 시간 운영에 적용하는 방법에 대해 다루도록 하겠다.

High power gate driver design using 555 timer and photo coupler for electronic/hybrid car and electroplating rectifier (전기/하이브리드 자동차, 도금용 정류기 등에 적용이 가능한 555 timer와 Photo Coupler를 이용한 대용량 SCR/IGBT용 Gate Driver 설계)

  • Cho, Eun Seok;Ko, Jae Su;Lee, Yong Keun
    • Korea Science and Art Forum
    • /
    • v.20
    • /
    • pp.421-428
    • /
    • 2015
  • Electronic/hybrid car and electroplating rectifier should have switching devices such as SCR, MOSFET, IGBT. And those switching devices should be operated by gate driver. In this paper, we propose high power gate driver that contains H-Bridge using 4 BJTs. H-Bridge and transformer generate isolate power. And gate control signal is transferred to isolated one by photo coupler and operate real switching device. We designed H-Bridge and 555-Timer by PSpice simulation and manufactured real product. Finally we succeed to operate 27V 50,000A electroplating rectifier using proposed gate driver.

Selection of Timer for Token Bus Automation Networks with Genetic Algorithm (유전자 알고리즘을 이용한 토큰버스 네트워크의 타이머 선정)

  • Lee, Sang-Ho;Lee, Gyung-Chang;Kim, Eon-Jun;Lee, Seok
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1996.04a
    • /
    • pp.516-520
    • /
    • 1996
  • This paper focues on development of a timer selection algorithm for IEEE802.4 token bus networks to serve large-scale integrated manufacturing systems. Such factory automation networks have to satisfy delay constraints imposed on time-critical messages while maintaining as much network capacity as possible for non-time-critical messages. Therefore, the object of this paper is to develop timer selection algorithm to minimize a certain penalty function. This paper presents an algorithm based on Genetic Algorithm. The efficacy of the algorithm has been demonstrated by a series of simulation experiments.

  • PDF