• 제목/요약/키워드: time-resolution

검색결과 3,320건 처리시간 0.043초

직장암 치료 시 치료계획에 따른 선량평가 연구 (A study of the plan dosimetic evaluation on the rectal cancer treatment)

  • 정현학;안범석;김대일;이양훈;이제희
    • 대한방사선치료학회지
    • /
    • 제28권2호
    • /
    • pp.171-178
    • /
    • 2016
  • 목 적 : 직장암 방사선 치료 시 대퇴골두의 선량을 최소화하기 위해, 보편적인 치료방법인 3문 입체조형치료계획(3D Conformal radiation therapy)과 5문 입체조형치료계획 그리고 용적변조방사선치료(Volumetric Modulated Arc Therapy, 이하 VMAT) 계획의 유용성을 비교, 평가하고자 한다. 대상 및 방법 : 본원에서 21EX(Varian Medical Systems, USA)를 이용하여 치료 받은 직장암 환자 10명을 대상으로 3문, 5문 입체조형치료계획과 VMAT 전산화치료계획을 각각 세우고 이에 대한 선량분포를 비교분석하였다. 전산화 치료계획은 Eclipse(Ver 10.0.42, Varian, USA)를 이용하였으며, 선량계산을 위해 PRO3(Progressive Resolution Optimizer 10.0.28), AAA(Anisotropic Analytic Algorithm Ver 10.0.28) 알고리즘을 사용하였다. 3문 치료계획은 6MV POST field 와 15MV LT, RT field를 갠트리 각도 $0^{\circ}$, $270^{\circ}$, $90^{\circ}$로 구성하였고, 5문 치료계획은 6MV POST field와 15MV RAO, RPO, LAO, LPO field를 갠트리 각도 $0^{\circ}$, $95^{\circ}$, $45^{\circ}$, $315^{\circ}$, $265^{\circ}$ 로 환자 체표면을 감싸는 형태로 구성하였다. VMAT 치료계획은 갠트리 회전반경이 $360^{\circ}$인 1개의 ARC를 이용하여 수립하였다. 처방선량은 30회에 걸쳐 직장에 총 선량이 54Gy가 되도록 하였다. VMAT 치료계획시 최적화(Optimization) 과정에서 나타나는 선량 차이의 무작위성을 최소화하기 위하여 2회의 최적화와 선량계산과정을 거쳤으며 처방선량의 100%가 표적용적의 95%를 포함할 수 있도록 Plan normalization을 조절하였다. 각 치료 계획의 Total MU, 대퇴골두와 acetabular fossa의 최대선량, PTV의 H.I. (Homogeneity Index), C.I.(Conformity Index)를 평가 지표로 설정하였고, 전자영상유도장치를 이용하여 임상 적용 가능 여부 확인을 위한 IMRT verification Q.A. (Gamma test)를 실시하였다. 결 과 : Rt. femoral head 최대선량은 3문, 5문, VMAT 치료계획 순으로 평균 53.08 Gy, 50.27 Gy, 30.92 Gy를 나타냈다. 마찬가지로 Lt. femoral head 에서도 같은 순으로 평균 53.68 Gy, 51.01 Gy, 평균 29.23 Gy를 나타냈다. Rt. Aceta fossa 의 최대선량은 3문, 5문, VMAT 치료계획 순으로 평균 54.86 Gy, 52.40 Gy, 30.37 Gy의 값을 보였다. Lt. Aceta fossa에서 또한 같은 순으로 평균 54.90 Gy, 52.77 Gy, 평균 31.79 Gy를 나타내어, both femoral head 와 aceta fossa의 최대선량이 3문, 5문, VMAT 치료계획 순으로 높았다. PTV에 대한 H.I.는 모두 서로 비슷한 결과를 나타냈고, C.I.는 3문, 5문, VMAT 치료계획 순으로 평균 1.64, 1.48, 평균 0.99로 VMAT 치료계획이 가장 낮은 것으로 나타났다. Total MU는 VMAT 치료계획이 3문과 5문 치료계획에 비해 각각 평균 124.4MU, 299MU 더 많이 사용하는 것으로 나타났다. VMAT 치료계획에 대한 IMRT verification Q.A. 결과 2mm / 2%, Gamma pass rate 90.0% 기준을 모두 초과하여 통과하였다. 결 론 : VMAT 치료계획은 3D 치료계획과 비교하여 대부분의 평가지표에서 우수한 것으로 나타났다. 특히 대퇴골두의 선량을 크게 감소 시켰으며, 저선량 영역에서는 소장이 받는 선량이 증가 하였으나 오히려 고선량 영역에서는 우수한 선량분포를 보였다. 하지만 VMAT을 지원하지 않는 장비와 치료계획 시 추가되는 Contouring, 그리고 정도관리에 관한 수고 등의 현실적인 제약 때문에 VMAT 치료계획을 선택하기 어려운 경우가 있을 수 있다. 5문 치료계획은 기존 3문 치료계획에 비해, 추가적인 문제에 구애받지 않고 대퇴골두의 선량을 줄일 수 있는 장점이 있다. 따라서 각 병원 상황에 맞게 치료계획을 선택하여 방사선 치료 효과를 높인다면, 직장암 환자의 효율적인 방사선치료 및 생존 기간의 연장뿐만 아니라 삶의 질 향상에도 도움이 될 것으로 판단한다.

  • PDF

우리나라 공군의 우주력 건설을 위한 정책적.법적고찰 (Research for Space Activities of Korea Air Force - Political and Legal Perspective)

  • 신성환
    • 항공우주정책ㆍ법학회지
    • /
    • 제18권
    • /
    • pp.135-183
    • /
    • 2003
  • 1957년 이래 1999년 8월까지 약 313회의 우주발사 실패가 있었다. NASA의 '우주수송을 발전시킨다'라는 목표하에서, 제6의 목적은 우주선의 사고발생위험을 10년내에 1/40으로, 25년내에 1/140으로 낮춘다는 것이다. 이는 곧 우주개발이 아직도 얼마나 위험한 것인가를 보여주는 통계자료이다. 왜 이렇게 위험한 우주여행을 감수하면서, 우주개발에 뛰어드는 것인가? 우주개발은 경제적인 측면에서 인공위성을 이용한 통신 및 방송산업은 21세기 초에이룩될 우주산업의 가장 큰 분야가 될 전망이다. 특히, 우주의 특수한 환경인 무중력상태와 지구상보다 1,000 배나 높은 진공상태를 이용한 새로운 반도체의 개발 및 생산 그리고 신약의 개발 등이 활발하게 이루어질 것인데, 지난 1986년부터 지난달까지 운용되던 러시아의 "미르" 우주정거장에서는 수정을 생산하여 판매 하였다. 현재 우주산업은 미국, EU, 일본 등 소수 선진국들이 주도하고 있으며, 세계우주산업 시장규모는 년 평균 10% 이상 지속적인 신장이 이루어질 것으로 전망하고 있으며, 특히 민간용 이동통신산업 확대, 우주탐사활동 증대, 우주정거장사업 추진등으로 우주산업 규모는 비약적으로 신장할 것으로 예측되며, 최근 5년간 ED와 일본은 연평균 15${\sim}$20 %의 고성장을 유지하고 있다. 미국 NASA가 1993년 가을부터 1996년 10월까지 3년동안 민간기업에 기술을 이전한 결과를 보면, 거시적 안목을 가지고 우주산업을 추진해야 함을 알 수 있다. NASA는 미국 전역에서 16,300개의 일자리를 창출하였으며, NASA 의 기술 이전으로 새로 생긴 상품은 938개에 달하며, NASA가 민간에 이전한 기술을 경제적 가치로 환산하면 매년 16억 달러에 달하며, 또한 기술지원을 받은 미국기업을 5,600개가 넘는다. 또한, 경제외적인 측면에서 국가의 안보, 자주국방을 위한 정보수집을 위해 결정적인 역할을 한다. 우리나라는 외국에서 발사한 7개의 위성을 운영하고 있으며, '03년 8월 8일 고흥 외나로도에 인공위성발사장 기공식을 함으로써, 국내우주개발계획에 박차를 가하고 았다. 이러한 국가적인 우주개발계획과 함께 공군의 우주력건설에 따른 고찰이 필요하다. 우리나라는 미국과의 MTCR 협의로 인하여, 사정거리 300km 이상의 미사일발사체를 개발하지 않도록 되어 있으므로, 현실적으로 국방부(공군) 자체에서 우주발사체를 개발하는 것은 어렵다. 현대전에서 항공우주력은 곧 전쟁의 승패를 결정하는 필수적인 요소이며, 이미 전장이 우주로 화대되어 있는 현실에 있어서, 군의 우주력건설은 '우주력건설의 당위성'을 논할 때가 아니고, '어떻게 군의 우주력건설'을 하여야 하는 가 '우주력건설의 방법론'에 대한 구체적인 연구가 되어야 할 때이다. 우주의 군사적이용에 대한 제한은 미국의 주장대로 "비침략적 이용(non-aggressive use)"이 옳은 판단이며, 구소련의 "비군사적 이용(non-military)"에 대한 주장은 옳지 않다. 이러한 구 소련의 주장은 러시아정부에서는 적극적으로 주장하고 있지도 않고 현실성도 없는 주장이다. 따라서, 미국의 우주의 평화적 이용에 대한 개념에 의하면, 다목적위성의 군정찰목적으로의 이용이나, 상업위성의 군통신 이용은 자유롭다고 할 것이다. 즉, 공군은 군정찰위성, 통신위성 개발을 민간연구부서와 자유롭게 할 수 있다고 본다, 다만, 미국과의 MTCR 협정상 우주발사체 개발에 대해서는 제한을 받고 있으나, 우주발사체개발은 한국항공우주연구원에 위임하고, 궤도에 있는 위성을 운용하면 문제가 없다고 본다. 다목적위성은 주 임무가 Remote Sensing 인데 High resolution 특히 SAR 센서는 주로 군사목적으로 이용되고 있다. 따라서, 다목적위성은 공군과 한국항공우주연구원, 국방과학연구소간의 공동으로 연구개발을 할 수 있는 제도가 마련되어야 한다. 미 공군도 현재 사용 중인 발사체를 단계적으로 제거하며 기업 발사체 이용을 증가시킨다. 또한, 군 통신의 특수성 때문에 민수용 통신 및 방송 서비스와는 독립적으로 운영되어 왔으나 군 통신 중계기와 민간 통신 중계기가 혼합되어 운용됨으로써 군 위성 통신의 단독에서 오는 경제적인 부담을 줄이기 위한 방안으로 각광을 받고 있다. 걸프전에서도 미국은 상용통신위성을 군 통신에 사용하였다. 우리나라의 우주과학기술 연구에의 착수는 다른 나라들과의 경제적 개발 정도와 비교해 볼 때 늦었으며, 우주개발예산 또한 상대적으로 일본은 2조원/년인데 비하여 우리는 5조원/15년으로 부족하다. 우주산업은 산업의 특성상 초기 육성기간은 산업체 수익사업으로 전개될 수 없으므로, 정부예산에 의한 사업추진이 불가피하다. 외국의 경우에도 우주개발 프로그램은 모두 정부사업이며, 최근 들어 통신 방송위성 등 극히 제한된 분야에 한해 민간사업이 추진되고 있을 뿐이다. 더욱이 우리나라와 같이 우주산업이 초창기에 있는 경우에는 이러한 필요성이 더욱 절박하며, 정부사업의 추진 시에도 정부지원예산의 회수를 전제로 하지 않는 정부출현 혹은 투자사업으로 추진되어야하는 것이 필수적 요소이다. 우주연구인력수준에 있어서도, 세계적으로 우주개발선전국들에 비하여 예산이 부족하며, 전문인력도 부족하다. 따라서, 국가 우주개발의 효율적이고 체계적인 추진과 사업 추진시의 힘의 분산 및 혼돈을 방지하기 위해서도 한국의 우주개발 체계에 대한 선명한 제시와 함께 국내 우주개발 관련 법령의 제정이 시급하다. 또한, 우리나라 우주개발은 각기다른 법령하에 각기 다른 주무부처에서 사업을 진행하고 있으므로, 국가적으로 집중적인 우주개발체제를 확립하는 것이 필요하다. 우주력건설을 위해서는 항공우주연구분야 즉 국방과학연구소와 한국항공우주연구원의 항공우주분야를 어떻게 협력 또는 통합하느냐에 대한 연구이전에, 우주력을 어떻게 운용할 것인가에 대한 근본적인 전략과 정책을 수립할 '우주작전본부'를 공군에 설립하는 것이 선과제이다.'우주작전본부'를 설립하기 위해서는 무엇보다도 국방부와 합참의 전략적인 의사결정이 필요하다. 특히, 일본의 군의 우주력건설에 대한 계획을 참고하여, 자주국방을 위한 최소한의 군사목적의 정찰위성, 통신위성, 우주감시체계의 확보가 필요하다. MTCR협정 등의 문제를 해결하기 위해서는 한국항공우주연구원의 발사체개발을 이용하고, 또한 다목적위성, 통신위성개발을 활용하기 위하여 국방예산을 확보하여야 하겠으며, 우선적으로 일본의 정찰위성 운용예산인 약 2조 5천억원정도의 우주예산을 국방부에서 먼저 확보할 필요가 있다.

  • PDF

Sensory Information Processing

  • Yoshimoto, Chiyoshi
    • 대한의용생체공학회:의공학회지
    • /
    • 제6권2호
    • /
    • pp.1-8
    • /
    • 1985
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70$\pm$1.32mmHg/min)compared to CF dialyzers(4.32$\pm$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500, 550, 570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500, 550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100, 300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3, 000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.SpO2 with Plethysmograph.

  • PDF

SCS-CN 산정을 위한 수치세부정밀토양도 활용과 괴산군 소수면 소유역의 물 유출량 평가 (Estimation of SCS Runoff Curve Number and Hydrograph by Using Highly Detailed Soil Map(1:5,000) in a Small Watershed, Sosu-myeon, Goesan-gun)

  • 홍석영;정강호;최철웅;장민원;김이현;손연규;하상건
    • 한국토양비료학회지
    • /
    • 제43권3호
    • /
    • pp.363-373
    • /
    • 2010
  • 수문 수자원 분야에서의 활용도를 제고하기 위하여 HSG 1995와 HSG 2006 두가지 분류법에 의한 우리나라 수문학적 토양유형의 분포에 대한 정보를 제공하고 이를 각각 충북 괴산군 소수면의 소유역의 수치세부정밀토양도 (1:5,000)에 적용하여 SCS-CN법을 이용한 유효 우량 산정과 유출곡선을 작성한 결과는 다음과 같다. 산악지에서 주로 침투능이 크고 하성 또는 해안평탄지로 가면서 낮아지는 경향을 보였다. HSG 1995 토양 유형 중 A군은 전체의 42.2%로 가장 넓게 분포하는 것으로 나타났고, B군 29.4%, C군 18.5%, D군 9.9% 순으로 나타났다. HSG 2006 토양유형은 A군 35.1%, B군 15.7%, C군 5.5%, D군 43.7%로 D군이 가장 넓게 분포하는 특징을 가진다. HSG 1995에서 A, B, C군으로 분류되었다가 HSG 2006에서 D군으로 분류된 토양 유형의 비율이 약 34.1%로 나타나 국립농업과학원에 의해 분류된 토양유형 중 D군의 면적이 크게 늘어난 것을 알 수 있었다. 충북 괴산군 소수면 소유역의 수치세부정밀토양도에 기반한 수문학적 토양유형 분포특성을 나타낸 것으로 산림과 밭으로 이용되는 토양의 유형이 A로 분류되는 것은 일치하는 경향을 보였다. HSG 2006의 토양유형은 유역에서 C 유형이 거의 없거나 적게 분포하고 HSG 1995에 비해 D 유형이 많게 나타난다. 미계측 유역에 대한 직접유출량 산정에 가장 많이 사용되는 SCS-CN법을 이용하여, 충북 괴산군 소수면 소유역에서 직접유출에 기여하는 유효우량을 산정하고 SCS 삼각단위도를 사용하여 첨두유량과 첨두시간을 계산한 결과는 다음과 같다. HSG 1995와 HSG 2006 수문학적 토양유형과 토지 이용별 CN값을 적용하여 유역의 CN값 (AMC II)을 구한 결과는 각각 54와 62로 나타났다. 이 때, 우량계가 설치된 지점의 강우자료를 평균하여 2004년~2005년 강우사상별로 정리하여 초기손실량 (I)이 총강우량 (P)보다 큰 경우를 제외한 강우사상을 선택하였고, 8월 16일에서 강우사상 전까지 내린 강수에 따라 선행수분조건 III으로 조정하여 유효우량 산출을 위한 CN값을 각각 73과 79로 하여 사용하였다. 강우사상에 대한 HSG 2006 기준의 유효우량이 56.67 mm로 HSG 1995 기준의 44.87 mm 보다 약 25% 많게 나타났다. 두 가지 수문학적 토양 유형 분류 기준에 따라 계산된 각 유효 우량에 대하여 수문곡선을 합성하여 실제 관측치와 비교한 결과 두 개 기준 모두 관측치와 유사한 변화 패턴을 보이고 있으나 실측치보다 감수부에서 급격하게 감소되는 특징을 나타냈다. 첨두유량은 HSG 1995 보다는 HSG 2006 기준을 사용할 때 관측치와 더 가까운 값을 나타내었다.

Cisternography 검사 시 사용되는 방사성의약품의 안정성 확보를 위한 검사도입 및 유용성 평가 (Evaluation of Usefulness and Procedures for Safety of Radiopharmaceuticals in Cisternography)

  • 김다은;유연욱;최호용;김윤철;김영석;원우재;김석기
    • 핵의학기술
    • /
    • 제14권2호
    • /
    • pp.45-49
    • /
    • 2010
  • 뇌조 조영술에 이용되는 방사성의약품들 중 최근에는 Tc-99m DTPA를 이용한 뇌 척수액 영상이 대부분이다. 하지만 Tc-99m DTPA는 사용 시 무균수막염, 근육강직, 경련 등 여러 부작용이 발생할 우려가 있다. 따라서 Tc-99m DTPA의 이러한 부작용의 발생을 사전에 예방하기 위하여 안정성검사를 시행하였으며 그 유용성을 알아보고자 한다. 방사성의약품 Vial검사는 2008년 12월 16일 - 2009년 12월 30일에 뇌조조영술을 시행한 환자(n=12)를 대상으로 시행하였으며, 시술시 사용한 vial내의 DTPA 성분 (Mallinckrodt사의 Techscan-DTPA사용), NaPertechnate radiation dose 및 volume, 생리 식염수량, 환자주사용 용량 및 activity 등을 측정하여 순수 DTPA의 양을 계산하였다. 방사성의약품의 내독소평가(Bacterial endotoxin)는 2008년 12월 16일-2009년 12월 30일에 뇌조 조영술을 시행한 환자(n=12)를 대상으로 하였고, 이 때 사용한 DTPA vial의 Pyrogen test (LAL test)를 시행하였다. 시약이 함유된 Positive/Negative control vial(표준액)에 normal saline 0.2 mL을 주입하고, 동일한 Test control vial(실험액)에 normal saline 0.1mL 와 Tc-99m DTPA 0.1 mL로 주입하였으며 Digital hot plate에서 $37.5^{\circ}C$로 1시간 반응시킨 후 응고여부를 표준액과 대조하여 관찰하였다. 안정적인 제조절차 준수는 보존제(방부제)가 없는 미 개봉한 CaNa3 DTPA kit를 사용하였으며 Tc-99m DTPA는 한 Vial당 한명의 환자선량으로 뽑아 투여한다. 이때 적정 용량을 맞추기 위해 0.9% NaCl 멸균 생리 식염수를 사용하여 희석하였다. 방사성의약품 Vial검사는 측정된 성분값들로 순수 DTPA의 양을 얻어내었으며 이는 2가지의 계산식을 이용하여 선량 대비 DTPA의 용량(평균 0.88 mg), 용량 대비 DTPA의 용량(평균 0.74 mg)을 도출해내었다. 방사성의약품의 내독소 평가에서는 동일한 조건으로 시험(n=12)을 시행한 결과 모두 Bacterial endotoxin이 기준치인 단위 선량 당 14 endotoxin units (EU)미만의 반응인 Negative(-)로 나왔다. 안정적인 제조절차 준수에서는 검사 관련 sheet를 만들어 작성 및 제조절차 준수 여부를 확인하였으며 결과 모두 준수하여 제조과정 내에서 방사성의약품에 의하여 발생할 수 있는 부작용이 없었다. Tc-99m DTPA를 이용한 Cisternography 검사 시 항상 방사성의약품의 안정성문제가 제기되어 왔다. 수막강 내 주입용 방사성의약품으로서 제조 및 사용 시 불안정한 취급으로 부작용이 발생할 우려가 있으며, 이에 따른 사용지침이 확립되어야 한다고 생각되었다. 수막강 내 주입용 방사선의약품으로써 free acid 혹은 sodium을 포함하는 DTPA는 적절하지 않으며, 반면 Calcium이 포함된 DTPA는 적절한 것으로 알려져 있다. 위와 같이 Techscan-DTPA(Mallinckrodt): CaNa3으로 간단하며 편리하게 안정성검사를 시행할 수 있었으며 각 검사결과(n=12) 안정성검사를 모두 통과하여 검사 시 동반될 수 있는 부작용은 나타나지 않았다. 앞으로 위와 같은 SOP (Standard Operating Procedures)를 적용하여 보다 쉽고, 편리하게 안정성검사를 시행할 수 있으리라 사료된다.

  • PDF

PET/CT 3D 영상에서 감쇠보정 위치 변화 방법을 이용한 영상 재구성법의 평가 (The Evaluation of Reconstruction Method Using Attenuation Correction Position Shifting in 3D PET/CT)

  • 홍건철;박선명;정은경;최춘기;석재동
    • 핵의학기술
    • /
    • 제14권2호
    • /
    • pp.172-176
    • /
    • 2010
  • PET/CT 검사에서 발생하는 환자의 움직임은 감쇠보정의 불일치를 초래하여 정량평가에 영향을 주게 되어 결과의 정확도를 저하시키게 된다. 본 연구에서는 PET/CT 3D 영상촬영에서 투과촬영 후 방출촬영의 위치변화에 따른 감쇠보정 불일치 시 감쇠보정 위치 변화 방법을 이용한 영상재구성법의 유용성에 대하여 평가하였다. GE Discovery STE16 장비에 스티로폼($20{\times}20{\times}10$ cm)의 중심점을 기준으로 x, y축 방향으로 ${\pm}2$, 6, 10 cm까지 1 mL 주사기 삽입 공간을 제작하였다. $^{18}F$-FDG 5 kBq/mL의 주사기를 중심점에서 투과촬영한 후 위치를 변화하여 방출촬영하고 위치 변화에 따른 감쇠보정 방법을 사용하여 영상을 얻었다. 재구성 방법은 반복영상 재구성법으로 반복횟수 2회, 부분집합 수 20을 적용하였으며 모든 방출촬영 데이터는 시간경과에 따른 붕괴보정을 적용하였다. 또한 주사기 위치에 관심영역을 설정한 후 방사능 값(kBq/mL)과 중심점에 대한 각 위치에서의 백분율 오차를 비교하였다. 방출영상의 중심점의 방사능 값은 2.30 kBq/mL이며, +x축 1.95, 1.82, 1.75 kBq/mL, -x축 2.07, 1.75, 1.65 kBq/mL, +y축 2.07, 1.87, 1.90 kBq/mL, -y축 2.17, 1.85, 1.67 kBq/mL로 나타났고, 백분율 오차는 +x축 15, 20, 23%, -x축 9, 23, 28%, +y축 12, 21, 20%, -y축 8, 22, 29%로 산출 되었다. 그리고 방출 영상에서 감쇠보정 위치변화 방법을 사용 하였을 경우 +x축 2.00, 1.95, 1.80 kBq/mL, -x축 2.25, 2.15, 1.90 kBq/mL, +y축 2.07, 1.90, 1.90 kBq/mL, -y축 2.10, 2.02, 1.72 kBq/mL로 나타났으며, 백분율 오차는 +x축 13, 15, 21%, -x축 2, 6, 17%, +y축 9, 17, 17%, -y축 8, 12, 25%로 산출 되었다. 감쇠보정 불일치 시 감쇠보정 위치변화 방법을 사용한 경우의 방사능 농도 값은 x, y축에서 평균 0.14, 0.03 kBq/mL 증가 하였고, 백분율 오차는 6.1, 4.2% 향상되었다. 또한 중심으로부터 멀어질수록 공간분해능이 저하되는 특성상 중심에서 먼 위치일수록 방사능 값의 저하현상은 커짐을 알 수 있었다. 그러나 실제 임상에서는 감약 정도가 더 커지기 때문에 이러한 불일치 시 그 오차는 더 클 것으로 사료된다. 따라서 감쇠보정이 일치하지 않는 부분의 병변에서는 감쇠보정 위치변화 방법을 적용하여 방사능 값의 오차를 감소시킬수 있을 것이다.

  • PDF

국토위성정보 활용기술 및 운영시스템 개발: 성과 및 의의 (CAS 500-1/2 Image Utilization Technology and System Development: Achievement and Contribution)

  • 윤성주;손종환;박형준;서정훈;이유진;반승환;최재승;김병국;이현직;이규성;권기억;이계동;정형섭;정윤재;최현;구대성;최명진;신윤수;최재완;어양담;정종철;한유경;오재홍;이수암;장은미;김태정
    • 대한원격탐사학회지
    • /
    • 제36권5_2호
    • /
    • pp.867-879
    • /
    • 2020
  • 본격적인 우주기술 활용시대가 전망되는 현재의 시점에서 고해상도 영상취득이 가능한 국토관측위성의 발사가 2021년으로 예정되어 있다. 이에 따라 국토관측위성의 지상국의 핵심설계요소로 영상사용자의 위성영상 활용성과 작업자의 처리효율성 증대가 강조되어 왔다. 이에 대응하여, 국토관측위성의 수집, 처리, 저장, 관리 및 활용을 위한 핵심기술과 국토관측위성 지상국의 운영시스템을 개발하는 국토관측위성 수집 및 활용기술개발 연구사업이 진행되었다. 본 논문에서는 상기 연구개발사업의 성과로 개발된 국토관측위성 활용핵심기술과 지상국 운영시스템 개발결과를 소개한다. 개발된 지상국 운영시스템은 한반도 전역의 GCP(Ground Control Point) chip DB(Database)와 DEM(Digital Elevation Model) DB를 시스템 내에 구축하여 자동화된 방식으로 정밀정사영상을 생성하기 위한 기술 및 시스템을 구현하였다. 나아가 생성된 정밀정사영상을 1:5,000 도엽단위로 분할한 도엽정사영상을 생산하여 향후 분석준비자료 (ARD(Analysis Ready Data)) 체계로 발전할 수 있도록 개발하였다. 또한 정밀정사영상 및 도엽정사영상으로부터 DSM(Digital Surface Model)자료, 변화탐지지도, 객체추출지도 등 다양한 활용산출물이 체계적으로 생산될 수 있도록 활용산출물 생산 SW를 지상국 운영시스템과 연동시킬 수 있게 개발하였다. 본 연구진이 개발한 국토위성정보 활용기술 및 운영시스템은 국내 최초로 한반도 GCP chip DB구축을 통해서 자동화된 정밀정사영상생성 기술을 확보하고 다양한 활용산출물의 생산을 위성지상국 운영시스템에 접목했다는 점에서 의의가 있다고 판단된다. 개발된 국토위성정보 운영시스템은 국토관측위성의 주 활용부처인 국토지리정보원 국토위성정보활용센터에 설치되었으며, 향후 동 센터의 업무에 크게 기여할 것으로 바라보고 있다. 또한, 향후 발사예정인 여러 저궤도 지구관측위성의 지상국 시스템에 대한 기준을 제시할 수 있을 것으로 기대한다.

N-13 암모니아와 양전자방출단층촬영 동적영상을 이용하여 심근혈류량을 정량화하는 새로운 방법 개발에 관한 연구 (A Refined Method for Quantification of Myocardial Blood Flow using N-13 Ammonia and Dynamic PET)

  • 김준영;이경한;김상은;최연성;주희경;김영진;김병태;최용
    • 대한핵의학회지
    • /
    • 제31권1호
    • /
    • pp.73-82
    • /
    • 1997
  • N-13 암모니아 PET 동적영상을 이용하여 심근혈류량을 측정할 때, 부분용적효과와 스필오버현상을 보정하는 새로운 방법을 고안하고, 이 방법을 이용하여 측정한 심근혈류량을 2구획모델만을 이용한 종래의 방법과 비교, 분석하여 새로운 방법에 대한 효율성과 정확성을 고찰한다. 9명의 관상동맥 환자에서 20mCi의 N-13 암모니아를 안정상태와 부하상태에서 주사한 후, PET 동적영상을 얻어 심근의 3부분(중격, 전면벽, 측면벽)과 좌심실방에 관심영역을 그려 시간-방사능곡선을 얻었다. 심근의 3부분에 대한 심근혈류량과 스필오버분획을 기하학적 관심영역 모델 개념을 2구획모델에 포함시킨 새로운 방법과 종래의 2구획모델 방법으로 각각 구하였다. 이때 관심영역의 위치에 따른 심근혈류량을 알아보기 위해서 심근 밖에서 좌심실 중심쪽으로 20개의 관심영역을 그리고, 위의 두 방법을 이용하여 심근혈류량을 구하였다. 종래의 N-13 암모니아 2구획모델과 기하학적 모델 개념을 2구획모델에 포함시킨 새로운 방법으로 모델 합치 곡선을 구하였다. 관심영역 위치 변화에 대한 심근혈류량의 값을 종래의 방법과 새로운 방법으로 구하고, 부분용적효과를 정확하게 보정하기 위하여 관심영역을 심내막쪽에 설정하였다. 총 108개의 심근관심영역에서 두 가지 방법을 이용하여 구한 심근혈류량 사이의 회귀곡선 기울기는 1.57, 상관계수는 0.88이었다. 그리고 같은 방법으로 얻어진 스필오버분획들도 선형적 상관관계(r=1.00, 기울기=0.98)가 있었다. 결론적으로 N-13 암모니아 PET 동적영상과 기하학적 모델 개념을 2구획모델에 포함시킨 새로운 방법을 이용하여 구한 심근혈류량은 종래의 방법보다 더 효율적이며 정확하게 정량화되어짐을 알 수 있었으며, 앞으로 임상환경에서 심근혈류량 정량분석연구에 유용할 것이라고 생각한다. 환자 군에 비해 유의하게 낮았다(p<0.01). 결론적으로, 흉통을 호소한 환자에서 심근관류 신티그라피상 정상인 경우에는 심장사건의 발생율이 낮음을 알 수 있었고, 특히 관동맥조영술에 관동맥병변이있는 환자와 없는 환자간에 1차 심장사건의 발생율에 유의한 차이가 없는 것을 고려하면, 심근관류 신티그라피가 정상소견을 보이는 흉통환자는 정상 관동맥조영술 소견을 보이는 환자에 준하여 치료하여도 좋을 것으로 사료되었다.리고 0.19, 0.40, 0.53, 0.61이었다. 실제 속도상수의 비 $k_3/k_4$에 대한 (BG-OCC)/OCC와 $R_A,\;R_v$간의 상관계수는 각각 0.983, 0.984, 0.999이었으며 그때의 기울기는 각각 1.76, 0.47, 1.25이었다. 결 론 : IPT 약역학은 시간이 흐름에 따라 혈류량의 변동에 비해 도파민 운반체량의 변동에 더욱 민감한 경향을 보였으며 $k_3/k_4$에 대한 (BG-OCC)/OCC, $R_A,\;R_v$의 결과간에 좋은 상관관계를 가졌다. 따라서 이러한 약역학 컴퓨터시뮬레이션이 SPECT 영상을 이용한 도파민 운반체 또는 수용체 정량분석을 최적화하는데 매우 유용할 것으로 생각된다.TEX>-CIT SPECT는 파킨슨병의 조기진단 및 진행 추적에 임상적으로 유용할 것으로 판단된다., SCC 4예, AC 1예)였으며, 11예 중 9예(81.8%)에서 방사선학적 검사결과와 Tc-99m MIBI섭취율의 변화가 일치하였다. 결론적으로, Tc-99m MIBI SPECT는 폐암병소의 국소화 및 방사선치료 효과의 판정에 어느정도 유용하리라 사료되었다.냈고 4명에서는 low CBD obstruction을 나타내었으며 후에 CBD stone, CBD carcinoma,

  • PDF

면역기능저하 환자에서 폐진균증에 대한 임상적 고찰 (Pulmonary Mycoses in Immunocompromised Hosts)

  • 서지영;박상준;강경우;고영민;김태성;정만표;김호중;한정호;최동철;송재훈;권오정;이종헌
    • Tuberculosis and Respiratory Diseases
    • /
    • 제45권6호
    • /
    • pp.1199-1213
    • /
    • 1998
  • 연구배경 : 최근 면역기능저하 환자들이 급증하고 있으며 이들에 있어서 새로 발생된 설명이 불가능한 폐침윤은 매우 흔하면서도 환자의 생명을 위협할 수 있는 상황으로 발전할 수 있다. 폐진균증은 이런 임상상에서 폐침윤의 중요한 원인으로 대두되고 있으나 이에 대한 연구가 많지 않아 본 연구를 시행하였다. 방 법 : 1996년 10월부터 1998년 4월까지 삼성서울병원에서 면역기능저하 환자 중 새로운 폐침윤이 있었던 환자로 조직학적으로 폐에서 진균이 증명되었거나 정상적으로 균이 자리지 않는 부위(sterile)에서 시행한 배양검사장 진균이 배양된 환자들을 대상으로 임상적 특정, 방사선학적 소견, 진단적 검사, 치료 및 그 결과에 대해 후향적인 조사를 시행하였다. 결 과 : 총 13명의 환자 (M : F=8 : 5, 연령 중앙값 47세)에서 14예의 폐진균증이 진단되었다. 진단은 asperogillosis가 12예였고 mucormycosis가 2예였다. 혈액암 환자 9명에서 10예, 장기이식 환자에서 4예의 폐진균증이 진단되었다. 3예에서는 진단당시 경험적 amphotericin B를 중앙값 9일(8-21일)간 투여받고 있었다. 혈액암군 10예 중 9예에서 폐침윤 발견당시 백혈구 감소증이 중앙값 16일동안 지속되었으며 발열(9/10), 기침(6/10), 가래(5/10), 호흡곤란(4/10), 흉통 (5/10), 악설음(4/10) 등의 증상과 징후가 흔하게 관찰되었다. 반면에 장기이식환자군에서는 증상 및 징후가 뚜렸하지 않은 경우가 많았다(p<0.05). 단순 흉부촬영상으로 새로운 폐침윤은 단일 혹은 다발성의 결절(6/14)이나 경결(consolidation)(8/14)의 형태로 나타났으며 흉부 단층촬영상에서는 간유리음영(14/14), 흉수(5/14), 동공형성(7/14) 등의 소견이 관찰되었다. 확진한 방법으로는 개흉술이 10예, 비디오 흉강경술이 2예, 경피적침흡인술이 1예, 농양의 농 배양검사가 1예였다. 모든 환자는 amphotericin B(591-2806mg) 투여를 받았으며 1예에서 liposomal amphotericin B, 1예에서 경구 itraconazole로 치료를 부분적으로 시행하였다. Amphotericin B 투여 후 12/14예에서 폐병변의 호전이 관찰되었으며 14예중 4예에서 사망하거나 회복이 불가능한 상태로 퇴원하였다. 결 론 : 혈액암의 치료로 과립구감소증이 있는 환자나 장기이식 환자에서 새로운 폐침윤이 결절이나 경결의 형태로 발현하면, 증상이 미미하거나 경험적 amphotericin B를 투여하고 있더라도 폐진균증을 의심을 해야하며 적극적인 진단과 치료로써 예후를 호전시킬 수 있을 것으로 기대된다.

  • PDF

니암지대황폐림지(泥岩地帶荒廢林地)의 지피식생(地被植生) 조성방법(造成方法)에 관(關)한 연구(硏究) - 니암특성((泥岩特性)과 조기녹화(早期綠化) - (Studies on the Method of Ground Vegetation Establishment of Denuded Forest Land in the Mudstone Region - The Characteristics of Mudstone and Speeded-up Reforestation -)

  • 정인구
    • 한국산림과학회지
    • /
    • 제19권1호
    • /
    • pp.1-23
    • /
    • 1973
  • 우리나라에서 식물생장(植物生長)이 가장 나쁜 니암지대(泥岩地帶) 황폐림지(荒廢林地)에 지피식생(地被植生)을 조성(造成)시키기 위하여 지피식생(地被植生) 조성시험(造成試驗)을 실시(實施)한 결과(結果)는 다음과 같다. 1. 객토량시험(客土量試驗)에 있어서 객토(客土)는 두께 15cm이상을 하여야만 객토(客土)의 효과(効果)를 인정(認定)할 수있었고, 10cm의 객토(客土)를 하고서도 시비(施肥)를 하지 않으면 생장(生長)이 불량(不良)하여 1cm 객토후(客土後) 비료(肥料)를 충분(充分)히 사용(使用)한 구(區)보다 못하였다. 또 파종혈(播種穴)의 깊이에 있어서 30cm구(區)와 40cm구(區)와는 그 성적차(成績差)를 인정(認定)할 수가 없었다. 식생대피복구(植生袋被覆區)와 무피복구(無被覆區)는 식물(植物)이 발아당시(發芽當時)에는 종자(種子)의 유실여부(流失如否)와 유시(幼時) 생장상(生長上)의 차(差)가 다소(多少)있었으나 가을 성적(成績) 결과(結果)는 차(差)를 인정(認定)할 수 없어서, 이것을 종합(綜合)하여 보면 객토(客土)는 10cm이상(以上)이고 파종혈(播種穴)($30cm{\times}30cm$)당(當) 30g(22:22:11 복비(複肥) 55g)의 시비(施肥)를 하여야 한다. 2. 객토파종별(客土播種別) 시험(試驗)에 있어서 화강암풍화토(花崗巖風化土), 응회암풍화토(凝灰岩風化土), 니암풍화토별(泥岩風化土別) 성적(成績)은 고도(高度)의 유의차(有意差)가 없어고, 각종녹화자재별(各種綠化資材別) 처리(處理)에서도 모연공구(毛筵工區)에서만 1%의 유의차(有意差)를 나타내었다. 이것을 종합(綜合)하면 본 바닥 산록(山麓)의 성취(成就)된 니암풍화토(泥岩風化土)를 객토(客土)로 사용(使用)하는 것이 효과적(効果的)이며 모연공구(毛筵工區)가 좋았다. 3. 니암지대(泥岩地帶)의 임지비암(林地肥岩)임지에는 기존임목(旣存林木)(소나무, 해송)이 1ha당(當) 2,000~3,000본(本) 산재(散在)되어 있으므로 1ah당(當) 22:22:11 복합비료(複合肥料)를 성분량(成分量)으로 110kg을 시용(施用)한 결과(結果) 시비당년(施肥當年)에는 차(差)를 인정(認定)할수 없었으나 다만 엽색(葉色)이 농록색(濃綠色)을 정(呈)하고 엽장(葉長)이 30~40% 더 신장(伸張)하였고 사방오리나무에 있어서 14:37:12 및 9:12:3 복비(複肥)를 본당성분량(本當成分量)으로 20g 구(區)와 40g 구(區)로 나누어 시비(施肥)한 결과(結果) 40g구(區)가 월등(越等)히 생장(生長)이 양호(良好)하였으며 비종간(肥種間)에는 차(差)이를 인정(認定)할수 없었다. 4. 임목(林木)의 근계신장상황(根系伸張狀況)은 소나무는 40년(年)을 자라도 니암(泥岩)을 뚫고 생장(生長)하는 직근신장(直根伸張)은 15cm에 불과(不過)하나 곰솔은 23cm까지 주근(主根)이 신장(伸張)할 수가 있으므로 소나무보다 해송의 직근(直根) 신장력(伸張力)이 강(强)하다. 측근전장(側根全長)은 소나무에서 20m 해송에서 13m이였고, 아까시아나무는 식재당시(植栽當時)에 길이에서 더밑으로 암석을 뚫지 못하고 측근(側根)만 발달(發達)하여 비교적(比較的) 수분(水分)이 보지(保持)되는 소나무밑으로 신장(伸張)하는 것이 통례(通例)이였으며, 니암잔적토(泥岩殘積土)에서는 8~10년(年)만에 고사(枯死)되고 만다. 한편 소나무의 수형(樹型)은 편편상(偏偏狀)인데 해송은 삼각형(三角形)에 수형(樹型)을 이루고 있는 것이 특이하다. 이상(以上)의 사실(事實)을 종합(綜合)하면 인공(人工) 조림시(造林時) 충분(充分)한 식혈(植穴)을 파주지 않으면 임목(林木) 생육(生育)이 어려우므로 충분(充分)한 식혈(植穴)과 비료(肥料)를 시용(施用)하여야만 니암지대(泥岩地帶) 황폐림지(荒廢林地)를 복구(復舊)할수 있을것이다.

  • PDF