• Title/Summary/Keyword: time-delayed controller

Search Result 97, Processing Time 0.025 seconds

Vehicle Maintenance Support System using CAN Communication (CAN 통신을 이용한 자동차 유지관리 지원 시스템)

  • Jiwon, Park;Seunghong, Han;Jaehyun, Park
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.27 no.6
    • /
    • pp.59-68
    • /
    • 2022
  • We propose the vehicle maintenance support system to alarm consumable replacement reminders to the vehicle owner. Since the delayed replacement of the consumables makes the condition of the vehicle worse, it is crucial to replace consumables in a recommended period. The vehicle maintenance support system alarms the replacement time, which is set by the vehicle owner, based on the mileage of the installed vehicle. It integrates speed information acquired from the Controller Area Network interface for communication between Electronic Control Unit and instrument panel, exposed at the On Board Diagnostics-II port, to calculate the vehicle mileage. By this, there is no additional wiring required for the system. We verify the system has only 0.28% error by comparing the mileage on the system with the instrument cluster on the vehicle. It automatically enters low-power mode consuming 15mW, which is a negligible amount for the typical conditions of the car, to prevent the vehicle battery from discharging when the ignition is off.

Quantitative Evaluation of the Semi-Actuated Signal Control Systems (반감응 신호제어의 정량적 효과 평가에 관한 연구)

  • Kim, Seung-Jin;Lee, Sang-Soo;Lee, Choul-Ki;Park, Sung-Kyun;Lee, Ho-Jun
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.12 no.3
    • /
    • pp.19-28
    • /
    • 2013
  • This study evaluated the quantitative effects of the deployment of semi-actuated signal systems using field data. For this, a semi-actuted signal system was deployed in the regional roadway network extensively. This paper investigated an operating strategy of semi-actuated signal systems for field application, and implemented the functional strategy into the standard signal controller. The performance was evaluated using three measures of effectiveness such as traffic volume, travel time, and the number of delayed vehicle. From the analysis results, traffic volume increased about 9.4% and 11.3% for morning and evening peak periods, respectively. The average travel time was reduced about 6.3% and 7.8% during morning and evening peak periods, respectively because of the expansion of bandwidths for major streets. In addition, the number of delayed vehicles was reduced about 36.4% and 23.9% for morning and evening peak periods, respectively. It is expected that the effectiveness of signal control system can be improved by incorporating a properly designed semi-actuated signal system in regional roadways with directional demand variation.

H Control for Networked Control Systems with Randomly Occurring Packet Losses and Disturbances (임의적 패킷 손실과 외란입력을 고려한 네트워크 제어 시스템의 H 제어기 설계)

  • Lee, Tae H.;Park, Ju H.;Kwon, Oh-Min;Lee, Sang-Moon
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.62 no.8
    • /
    • pp.1132-1137
    • /
    • 2013
  • This paper considers the $H_{\infty}$ control problem for networked control systems(NCSs). In order to solve the problem which comes from discontinuous control signal in NCSs, an approach that discontinuous control signals treat time-varying delayed continuous signals is applied to achieve $H_{\infty}$ stability of NCSs. In addition, randomly occurring packet losses and disturbances are considered by introducing stochastic variables with Bernoulli distribution. Based on Lyapunov stability theory, a new stability condition is obtained via linear matrix inequality formulation to find the $H_{\infty}$ controller which achieves the mean square stability of NCSs. Finally, the proposed method is applied to a numerical example in order to show the effectiveness of our results.

Adaptive Feedforward Rejection of Microactuator Resonance in Hard Disk Drive Dual-stage Actuator Servo (하드디스크 드라이브 마이크로 구동기의 공진 영향 제거를 위한 적응 피드포워드 제어)

  • Oh, Dong-Ho;Lee, Seung-Hi;Baek, Sang-Eun;Na, Hee-Seung
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2000.06a
    • /
    • pp.1596-1600
    • /
    • 2000
  • We propose a novel adaptive feed forward controller (AFC) design method for rejecting the effect of micro actuator resonance in the design of dual-stage actuator servo systems for disk drives. Microactuator's resonance is one of important issues in dual-stage actuator servo, which varies up to ${\pm}10%$ per product and even during operation. We derive an adaptive algorithm for the proposed AFC design, which turns out to be identical to the delayed-x LMS algorithm which is a special form of the filtered-x LMS algorithm. In the algorithm, coefficients of the AFC are adapted by the residuals of constrained structure defined in such a way that the coefficients become time invariant. Contrary to the conventional AFC, it considers the phase delay of closed-loop transfer function at resonance frequency for system stability. We also apply an adaptive algorithm with frequency tracking capability. The frequency tracking algorithm is induced by the orthogonality of AFC coefficients. Computer simulations are carried out to demonstrate effect of the proposed AFCs.

  • PDF

Development of a self-leveling system for the bucket of an agricultural front-end loader using an electro hydraulic proportional valve and a tilt sensor (전자유압 비례밸브와 경사센서를 이용한 농용 프론트 로더 버켓 능동수평유지 시스템 개발)

  • Lee, Chang Joo;Ha, Jong Woo;Choi, Deok Su;Kim, Hak Jin
    • Journal of Drive and Control
    • /
    • v.12 no.4
    • /
    • pp.60-70
    • /
    • 2015
  • A front-end loader (FEL) mounted on an agricultural tractor is one of the most commonly used implements for farm work. However, when the tractor carries material using the bucket attached to the FEL on a sloping ground, the materials can spill or roll back over the operator due to the tilted body, thereby requiring the bucket surface to remain level at a constant value regardless of varying slopes. In this study, an active system for controlling the angle of the FEL bucket on a tractor based on the real-time measurement of ground slopes was developed to enable the bucket to constantly remain level. A FEL simulator operated based on an electro hydraulic proportional valve (EHPV) was constructed in the laboratory to develop a proportional-integral-derivative (PID) controller forming a virtual electronic control unit (ECU) on the computer, which could automatically adjust the bucket angles depending on varying input angles while sending SAE-J1939 associated messages via CAN BUS to the EHPV. The different parameter values for the PID controller due to the gravity effect of the bucket were determined using a manual PID tuning method while assuming that the tractor travels on either an ascending slope or a descending slope. The developed PID control-based self-leveling system showed a mean of steady-state errors of within $1^{\circ}$ and a mean of delayed times of ~ 0.8s when the step input of $+20^{\circ}$ was given, implying that the developed system and control algorithm would be effective in maintaining the bucket angle at a certain value. Future studies include the improvement of the control algorithm to reduce such a time delay as well as the application of the developed algorithm to the FEL mounted on a tractor tested at a testing ground.

Development of a Nuclear Steam Generator Tube Inspection/maintenance Robot

  • Shin, Ho-Cheol;Kim, Seung-Ho;Seo, Yong-Chil;Jung, Kyung-Min;Jung, Seung-Ho;Choi, Chang-Hwan
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2003.10a
    • /
    • pp.2508-2513
    • /
    • 2003
  • This paper presents a nuclear steam generator tube inspection/maintenance robot system. The robot assists in automatic non-destructive testing and the repair of nuclear steam generator tubes welded into a thick tube sheet that caps a hemispherical or quarter-sphere plenum which is a high-radiation area. For easy carriage and installation, the robot system consists of three separable parts: a manipulator, a water-chamber entering and leaving device for the manipulator and a manipulator base pose adjusting device. A software program to control and manage the robotic system has been developed on the NT based OS to increase the usability. The software program provides a robot installation function, a robot calibration function, a managing and arranging function for the eddy-current test, a real time 3-D graphic simulation function which offers remote reality to operators and so on. The image information acquired from the camera attached to the end-effecter is used to calibrate the end-effecter pose error and the time-delayed control algorithm is applied to calculate the optimal PID gain of the position controller. The developed robotic system has been tested in the Ulchin NPP type steam generator mockup in a laboratory.

  • PDF

The fabrication and evaluation of CdS sensor for diagnostic x-ray detector application (진단 X선 검출기 적용을 위한 CdS 센서 제작 및 성능 평가)

  • Park, Ji-Koon;Lee, Mi-Hyun;Choi, Young-Zoon;Jung, Bong-Zae;Choi, Il-Hong;Kang, Sang-Sik
    • Journal of the Korean Society of Radiology
    • /
    • v.4 no.2
    • /
    • pp.21-25
    • /
    • 2010
  • Recently, various semiconductor compounds as radiation detection material have been researched for a diagnostic x-ray detector application. In this paper, we have fabricated the CdS detecton sensor that has good photosensitivity and high x-ray absorption efficiency among other semiconductor compounds, and evaluated the application feasibility by investigating the detection properties about energy range of diagnostic x-ray generator. We have fabricated the line voltage selector(LCV) for a signal acquisition and quantities of CdS sensor, and designed the voltage detection circuit and rectifying circuit. Also, we have used a relative relation algorithm according to x-ray exposure condition, and fabricated the interface board with DAC controller. Performance evaluation was investigated by data processing using ANOVA program from voltage profile characteristics according to resistive change obtained by a tube voltage, tube current, and exposure time that is a exposure condition of x-ray generator. From experimental results, an error rates were reduced according to increasing of a tube voltage and tube current, and a good properties of 6%(at 90 kVp) and 0.4%(at 320 mA) ere showed. and coefficient of determination was 0.98 with relative relation of 1:1. The error rate according to x-ray exposure time showed exponential reduction because of delayed response velocity of CdS material, and the error rate has 2.3% at 320 msec. Finally, the error rate according to x-ray dose is below 10%, and a high relative relation was showed with coefficient of determination of 0.9898.