• Title/Summary/Keyword: time-clipping

Search Result 101, Processing Time 0.028 seconds

Design and Construction of Multi-wire Proportional Counter and Preamplifier for Measurement of Charged Particle (하전입자의 측정을 위한 다중선 비례계수기와 전치증폭기의 설계 제작)

  • Kim, Jong-Soo;Yoon, Suk-Chull
    • Journal of Radiation Protection and Research
    • /
    • v.21 no.2
    • /
    • pp.139-143
    • /
    • 1996
  • A multi-wire proportional counter with large sensitive area was designed and constructed considering diameter of anode wire. its material and space. A preamplifier connecting detector to main amplifier or counter was also designed and constructed for measurement output pulse from multi-wire proportional counter. The preamplifier was composed of charge-sensitive differential circuit. clipping circuit and amplification circuit. To test the performance of this equipment, terminal output pulse from the preamplifier was measured and compared with noise For these tests $^{239}Pu(360 Bq)\;and\; ^{90}Sr/^{90}Y(250 Bq)$ were used as radiation sources. The noise ingredient contributing to the maximum amplitude(180mV from $^{239}Pu$ and 200 mV from $^{90}Sr/^{90}Y$) was found to be very small(8 mV) Piled up pulse occurring at the output pulse of charge-sensitive differential circuit was measured as an independent pulse since this affected the amplification in the clipping circuit and amplification circuit. This information can be used to improve the loss of measurement due to piled up pulse.

  • PDF

Seasonal Growth Inhibition of Perennial Ryegrass (Lolium perenne L.) after Applying Two Plant Growth Regulators (생장조정제 처리 후 생육 시기별 퍼레니얼 라이그래스의 억제 효과)

  • Seung Jae Lim;Tae Wooung Kim;Young-Sun Kim
    • Journal of Bio-Environment Control
    • /
    • v.32 no.3
    • /
    • pp.242-248
    • /
    • 2023
  • This study was conducted to evaluate the effects of trinexapac-ethyl (TE) and prohexadione-calcium (PC) on the growth and turf quality of perennial ryegrass (Lolium perenne L.). Treatments were designed as follows; control (non-treatment), TE (TE 0.01 a.i. g·m-2·100mL-1), and PC (PC 0.01 a.i. g·m-2·100mL-1). Compared with control, turf color index and chlorophyll content of TE and PC treatments were not significantly different. As applied plant growth regulators (PGRs), shoot length in the TE and PC was decreased by 8.9-12.4% and 6.7-13.6%, respectively, and clipping yield by 44.4-45.8% and 40.6-40.9%. When evaluated with the growth of shoot length after applying PGRs, residual days of TE and PC were 43.6 and 37.9 days after treatment of PGRs (DAT) in the 1st experiment (July 29-August 26), respectively, and 38.3 and 39.5 DATs in the 2nd experiment (September 30-October 28). These results indicated that an application of TE or PC decreased shoot length and clipping yield in the perennial ryegrass, and their residual time was about 40±3 DATs. Perennial ryegrass applied with PGRs like TE and PC was not significant seasonal difference, and might be not phytotoxic.

Camera Tracking Method based on Model with Multiple Planes (다수의 평면을 가지는 모델기반 카메라 추적방법)

  • Lee, In-Pyo;Nam, Bo-Dam;Hong, Hyun-Ki
    • Journal of Korea Game Society
    • /
    • v.11 no.4
    • /
    • pp.143-149
    • /
    • 2011
  • This paper presents a novel camera tracking method based on model with multiple planes. The proposed algorithm detects QR code that is one of the most popular types of two-dimensional barcodes. A 3D model is imported from the detected QR code for augmented reality application. Based on the geometric property of the model, the vertices are detected and tracked using optical flow. A clipping algorithm is applied to identify each plane from model surfaces. The proposed method estimates the homography from coplanar feature correspondences, which is used to obtain the initial camera motion parameters. After deriving a linear equation from many feature points on the model and their 3D information, we employ DLT(Direct Linear Transform) to compute camera information. In the final step, the error of camera poses in every frame are minimized with local Bundle Adjustment algorithm in real-time.

Establishment of an easy Ic measurement method of HTS superconducting tapes using clipped voltage taps

  • Shin, Hyung-Seop;Nisay, Arman;Dedicatoria, Marlon;Sim, KiDeok
    • Progress in Superconductivity and Cryogenics
    • /
    • v.16 no.2
    • /
    • pp.29-32
    • /
    • 2014
  • The critical current, $I_c$ of HTS superconducting tapes can be measured by transport or contactless method. Practically, the transport method using the four-probe method is the most common. In this study, a simple test procedure by clipping the voltage lead taps have been introduced instead of soldering which reduces time and effort and thereby achieving a much faster measurement of $I_c$. When using a pair of iron clips, $I_c$ value decreased as compared with the measured one by standard method using soldered voltage taps and varies with the width of the clipped specimen part. However, when using a pure Cu clip, both by clipping and by soldering voltage taps give a comparable result and $I_c$ measured are equal and close to the samples specification. As a result, material to be used as voltage clip should be considered and should not influence the potential voltage between the leads during $I_c$ measurement. Furthermore, the simulation result of magnetic flux during $I_c$ measurement test showed that the decrease of $I_c$ observed in the experiment is due to the magnetic flux density, $B_y$ produced at the clipped part of the sample by the operating current with iron clips attached to the sample.

Role of Three-dimensional Computed Tomography Angiography in the Follow-up of Patients with Aneurysm Clips

  • Park, Seong-Hyun;Park, Jae-Chan;Hwang, Jeong-Hyun;Hwang, Sung-Kyoo;Hamm, In-Suk
    • Journal of Korean Neurosurgical Society
    • /
    • v.39 no.6
    • /
    • pp.427-431
    • /
    • 2006
  • Objective : The purpose of this study is to assess the usefulness of three-dimensional computed tomography angiography [3D-CTA] as a postoperative follow-up examination after intracranial aneurysms have been clipped. Methods : Between January 2002 and June 2005, 522 consecutive patients received treatment for intracranial aneurysms. A retrospective analysis of 310 patients with postoperative 3D-CTAs was performed to evaluate aneurysmal remnants and de novo aneurysms. This study was conducted in 271 patients with at least immediate and 6-month routine 3D-CT As for postoperative clipped aneurysm and 39 patients with 3D-CTAs for clipped aneurysm before 2002 when there was no 3D-CTA in our hospital. Results : Eight patients had abnormal CT angiographic findings. Aneurysm remnants were revealed in 4 patients and de novo aneurysms were discovered in 5 patients. Two patients were found at the postoperative 6-month 3D-CTA performed routinely. In 1 patient, the aneurysm was demonstrated on the way to the examination of syncope. In 2 patients, the author recommended 3D-CTA although there was no symptom because the patients had visited our institute long time ago [5.1, 4.5 years]. Of the 8 patients, 2 remnants and 1 de novo aneurysm were treated by endovascular treatment. Three de novo aneurysms at the middle cerebral artery and 1 pericallosal artery aneurysm were treated by direct clipping because these aneurysms were not suitable for the endovascular treatment in point of anatomical configuration. One patient with both remnant and de novo aneurysm was treated conservatively. Conclusion : 3D-CTA is an available, non-invasive diagnostic tool for the postoperative follow-up examination of aneurysmal state in patients after clipping.

Study on Preventing Bit Error of Digital Watermark Using Orthogonal Transform

  • Watanabe, Jun;Hasegawa, Madoka;Kato, Shigeo
    • Proceedings of the IEEK Conference
    • /
    • 2002.07a
    • /
    • pp.277-280
    • /
    • 2002
  • Many digital watermarking methods have been proposed for copyright protection. Especially, methods to add a watermark in the frequency domain are often used. In those methods, only a few components of frequencies are changed according to watermark information, so that the pixel values of the image obtained by the inverse transform sometimes exceed the dynamic range and owing to the clipping process at this time watermark information is changed. This phenomenon even occurs without attacks like image processing. In this paper, we propose two methods to prevent loss of watermark information, applicable to such cases, it is said that one is the method called "inversion of increase and decrease" and another is "conservation of amounts of changes." We can extract the watermark information correctly under the condition of no attacks by using these proposed methods.

  • PDF

Recurrent Subarachnoid Hemorrhage after Complete Obliteration of Intracranial Aneurysm

  • Yang, Tae-Ki;Kim, Chul-Jin
    • Journal of Korean Neurosurgical Society
    • /
    • v.46 no.5
    • /
    • pp.492-494
    • /
    • 2009
  • The authors report a case of recurrent subarachnoid hemorrhage (SAH) after complete occlusion of an intracranial aneurysm. It is known that regrowth of an aneurysm after the complete clipping is a rare event. For detection of recurrence, however, it may be necessary to follow up with the patient regularly after the initial operation for intracranial aneurysms, because re-rupture of an aneurysm can cause a fatal result, and the cumulative risk of a recurrent SAH is thought to be not low over time.

Thoracoscopic Enucleation of Esophageal Leiomyoma (흉강경을 이용한 식도 평활근종의 절제)

  • 이성호
    • Journal of Chest Surgery
    • /
    • v.28 no.5
    • /
    • pp.518-520
    • /
    • 1995
  • Leiomyoma is the most common benign tumor of the esophagus,and surgical enucleation is the treatment of choice. Recently we successfully performed thoracoscopic enucleation of large esophageal leiomyoma without complication in one patient. The 46 years old male patient complained epigastric discomfort and showed a submucosal mass in lower esophagus under the endoscopic ultrasonography . During operation minimal perforation occurred, it was closed with clipping without conversion to an open procedure.The tumor size was 8cm x 3cm x 1.5cm respectively. There were less post-operative pain,minimal wound size, and early recovery time.Patient was satisfactory these outcome. These result suggest that esophageal enucleation was performed more large size benign tumor and esophageal perforation during operation was treated thoracoscopically.

  • PDF

Coil Embolization of Aneurysm Followed by Stereotactic Aspiration of Hematoma in a Patient with Anterior Communicating Artery Aneurysm Presenting with SAH and ICH

  • Kim, Sung-Ho;Yoon, Seok-Mann;Shim, Jai-Joon;Bae, Hack-Gun
    • Journal of Korean Neurosurgical Society
    • /
    • v.43 no.1
    • /
    • pp.41-44
    • /
    • 2008
  • Even though intracerebral hematoma (ICH) due to ruptured cerebral aneurysm has been treated by aneurysm clipping at the same time of removal of ICH through craniotomy, such management strategy is controversial in an aged patients with poor clinical grade. In this regards, stereotactic aspiration of hematoma following coil embolization can be an alternative treatment modality. Thus, the authors report a case of an aged patient who underwent stereotactic aspiration of ICH following coil embolization for the ruptured aneurysm with a brief review of literature.

High Speed Measurement of Ball Height Data for Ball Grid Arrays (BGA(Ball Grid Array) 높이 데이타의 고속 측정)

  • Cho Tai-Hoon;Joo Hyo-Nam
    • Journal of the Semiconductor & Display Technology
    • /
    • v.5 no.1 s.14
    • /
    • pp.1-4
    • /
    • 2006
  • Recently, Ball Grid Arrays(BGAs) are getting used more frequently for a package type. The connectors on a BGA consist of a large number of small solder balls in a grid shape on its bottom side. However, since balls of BGAs mounted on PCBs are not visible, inspection before mounting them is indispensable. High speed non-contact 3D measurement technologies are necessary far real-time measurement of ball height, the most important inspection item. In this paper, an accurate 3D data acquisition system for BGAs is proposed that can acquire 3D profile at high speed using a 3D smart camera and laser slit ray projection. Some clipping and morphological filtering operations are employed to remove spiky error data, which occur due to reflections from some ball area to camera direction.

  • PDF