• Title/Summary/Keyword: time-and-motion study

Search Result 2,264, Processing Time 0.039 seconds

Improvements for Atmospheric Motion Vectors Algorithm Using First Guess by Optical Flow Method (옵티컬 플로우 방법으로 계산된 초기 바람 추정치에 따른 대기운동벡터 알고리즘 개선 연구)

  • Oh, Yurim;Park, Hyungmin;Kim, Jae Hwan;Kim, Somyoung
    • Korean Journal of Remote Sensing
    • /
    • v.36 no.5_1
    • /
    • pp.763-774
    • /
    • 2020
  • Wind data forecasted from the numerical weather prediction (NWP) model is generally used as the first-guess of the target tracking process to obtain the atmospheric motion vectors(AMVs) because it increases tracking accuracy and reduce computational time. However, there is a contradiction that the NWP model used as the first-guess is used again as the reference in the AMVs verification process. To overcome this problem, model-independent first guesses are required. In this study, we propose the AMVs derivation from Lucas and Kanade optical flow method and then using it as the first guess. To retrieve AMVs, Himawari-8/AHI geostationary satellite level-1B data were used at 00, 06, 12, and 18 UTC from August 19 to September 5, 2015. To evaluate the impact of applying the optical flow method on the AMV derivation, cross-validation has been conducted in three ways as follows. (1) Without the first-guess, (2) NWP (KMA/UM) forecasted wind as the first-guess, and (3) Optical flow method based wind as the first-guess. As the results of verification using ECMWF ERA-Interim reanalysis data, the highest precision (RMSVD: 5.296-5.804 ms-1) was obtained using optical flow based winds as the first-guess. In addition, the computation speed for AMVs derivation was the slowest without the first-guess test, but the other two had similar performance. Thus, applying the optical flow method in the target tracking process of AMVs algorithm, this study showed that the optical flow method is very effective as a first guess for model-independent AMVs derivation.

A Study on the Clauses of the Work-Related Disease due to Overwork in the Workmen's Compensation Law (과로로 인한 업무상 질병의 산재보상 인정기준에 관한 연구)

  • Kim, Eun Hee
    • Korean Journal of Occupational Health Nursing
    • /
    • v.6 no.1
    • /
    • pp.23-43
    • /
    • 1997
  • The work-related diseases due to continuous overwork are mainly cerebro- and cardio-vascular ones, which is commonly called 'Karoshi', death from overwork. Many factors are capable for Karoshi : occupational stress in relation to technological renovation and industrial rationalization, competitive social structure, and accumulated fatigue accured to long time or irregular working. And its occurence is on the rise. The World Labor Report 1993 released by ILO, pointed out the diseases related to overwork and stress as one of the most important occupational health problem. In Korea, social awareness of Karoshi is at an infant stage, and reliable statistics for its occurence are not compiled in a convenient manner. Despite the rising Karoshi, there are no reliable clauses in workmen's compensation enough to settle down the disputes. Therefore, it is not uncommon that the Labour Ministry and Civil Court find difficulties in reaching an agreement. This study was intended to provide proper compensation and prevention program for workers by suggesting reasonable compensation clauses for the death from overwork. This study consists of two comparative reviews on the compensaton clauses for the death from overwork. One is to review legal standards of Karoshi among three countries, such as Korea, Japan and Taiwan. The other is to investigate the cases of Karoshi in Korea, 121 cases identified at the Labor Welfare Corperation and the Labour Ministrial process of examination and reexamination, and 73 leading cases at the High Court of Justice. The main findings of the study are as follows : 1. Comparisons of comperative review on compensation clauses for the death from overwork among three countries. 1) All of three countries have the same kinds of disease for compensation, which were cerebro-and cardiao-vascular diseases, while for cardiac disease group, Korea has the smaller number of diseases for compensation than Japan. 2) As for the definition of overwork, the three countries share equally that overload for one week prior to collapse is considered as an important factor, but accumulated chronic fatigue is disregarded. 3) As the basis of overwork, in Japan, there is a tendency to move from the conditions of an ordinary healthy adult to those of the individual concerned in Japan, whereas there is no such concern yet in Korea. 4) All the three countries use a common standard of medical judgement in demonstrating causal relationship between a job and a disease. However, Korea is progressive in the sense that in the case of CVA at worksite, the worker himself has no obligation to prove the cause. 2. The results of a comparative review on excutive decisions by Labor Ministry and judicial decisions by the Court in Korea : A judicial decision is based on the legalistic probability, but a excutive decision is not. Therefore, excutive decisions have such restrictions that : 1) TIA (transitory ischemic cerebral attack) and myocarditis are excluded from compensation, and there is little consistency of decision in the case of cause-unknown death. 2) There is a tendency not to compensate for the death from overwork since the work terms such as repeated long-time working, shift work or night-shift work are not considered as overloading. 3) There is a tendency to regard the conditions of a ordinary healthy adult rather than those of the individual concerned(age, existing diseases, health state, etc.) as the comparative basis of overload. 4) There remains a tendency not to compensate for the death from overwork in the case of collapse occuring out of workplace, on the ground of 'on the course of working' and 'in the cause of accident'. Through the study, the fact manifests itself that Korea's compensation clauses for work-related diseases due to overwork are very restrictive. So, it is necessary to extend the Labor Ministry's clauses of compensation for the death from overwork following to the recent changes of other countries and internal judicial decisions. This is very important in the perspective of occupational health that aims at health promotion of workers including prevention of the Karoshi.

  • PDF

Is It Appropriate to Insert Pedicle Screws at an Infected Vertebral Body in the Treatment of Lumbar Pyogenic Spondylodiscitis? (요추부 화농성 척추염의 수술적 치료: 이환된 추체에 척추경 나사 고정이 타당한가?)

  • Na, Hwa-Yeop;Jung, Yu-Hun;Lee, Joo-Young;Kim, Hyung-Do
    • Journal of the Korean Orthopaedic Association
    • /
    • v.56 no.5
    • /
    • pp.419-426
    • /
    • 2021
  • Purpose: In the surgical treatment of pyogenic lumbar spondylodiscitis, screw insertion at the affected vertebra has been avoided because of biofilm formation, and the risk of infection recurrence. The authors analyzed the success rate of infection treatment while minimizing the number of instrumented segments by inserting pedicle screws into the affected vertebrae. Therefore, this study examined the usefulness of this technique. Materials and Methods: From January 2000 to June 2018, among patients with pyogenic lumbar spondylodiscitis treated surgically, group A consisted of patients with pedicle screws inserted directly at the affected vertebrae (28 cases), and group B underwent fusion by inserting screws at the adjacent normal vertebrae due to bone destruction of the affected vertebral pedicle (20 cases). The classified clinical results were analyzed retrospectively. All patients were treated via the posterior-only approach, so the affected disc and sequestrum were removed. Posterior interbody fusion was performed with an autogenous strut bone graft, and the segments were then stabilized with pedicle screw systems. The hospitalization period, operation time, amount of blood loss, EQ-5D index, duration of intravenous antibiotics, and the clinical and radiological results were analyzed. Results: In group A, the number of instrumented segments, operation time, blood loss, and EQ-5D index at one month postoperatively showed significant improvement compared to group B. There were no significant differences in the duration of antibiotic use, hospitalization, radiological bone union time, sagittal angle correction rate, and recurrence rate. Conclusion: Minimal segmental fixation, in which pedicle screws were inserted directly into the affected vertebrae through the posterior approach, reduced the surgery time and blood loss, preserved the lumbar motion by minimizing fixed segments and showed rapid recovery without spreading or recurrence of infection. Therefore, this procedure recommended for the surgical treatment of lumbar pyogenic spondyodiscitis.

Utility Estimation of the Manufactured Stereotactic Body Radiotherapy Immobilization (자체 제작한 정위적체부방사선치료(Stereotactic Body Radiotherapy) 고정용구의 유용성 평가)

  • Lee, Dong-Hoon;Ahn, Jong-Ho;Seo, Jeong-Min;Shin, Eun-Hyeok;Choi, Byeong-Gi;Song, Gi-Won
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.23 no.1
    • /
    • pp.1-6
    • /
    • 2011
  • Purpose: Immobilizations used in order to maintain the reproducibility of a patient set-up and the stable posture for a long period are important more than anything else for the accurate treatment when the stereotactic body radiotherapy is underway. So the purpose of this study is to adapt the optimum immobilizations for the stereotactic body radiotherapy by comparing two commercial immobilizations with the self-manufactured immobilizations. Materials and Methods: Five people were selected for the experiment and three different immobilizations (A: Wing-board, B: BodyFix system, C: Arm up holder with vac-lock) were used to each target. After deciding on the target's most stable respiratory cycles, the targets were asked to wear a goggle monitor and maintain their respiration regularly for thirty minutes to obtain the respiratory signals. To analyze the respiratory signal, the standard deviation and the variation value of the peak value and the valley value of the respiratory signal were separated by time zone with the self-developed program at the hospital and each tie-downs were compared for the estimation by calculating a comparative index using the above. Results: The stability of each immobilizations were measured in consideration of deviation changes studied in each respiratory time lapse. Comparative indexes of each immobilizations of each experimenter are shown to be A: 11.20, B: 4.87, C: 1.63 / A: 3.94, B: 0.67, C: 0.13 / A: 2.41, B: 0.29, C: 0.04 / A: 0.16, B: 0.19, C: 0.007 / A: 35.70, B: 2.37, C: 1.86. And when all five experimenters wore the immobilizations C, the test proved the most stable value while four people wearing A and one man wearing D expressed relatively the most unstable respiratory outcomes. Conclusion: The self-developed immobilizations, so called the arm up holder vac-lock for the stereotactic body radiotherapy is expected to improve the effect of the treatment by decreasing the intra-fraction organ motions because it keeps the respiration more stable than other two immobilizations. Particularly in case of the stereotactic body therapy which requires the maintenance of set-up state for a long time, the self-developed immobilizations is thought to more useful for stereotactic body radiotherapy rather than the rest two immobilizations with instable respiratory cycle as time passes.

  • PDF

Processing and Quality Control of Flux Data at Gwangneung Forest (광릉 산림의 플럭스 자료 처리와 품질 관리)

  • Lim, Hee-Jeong;Lee, Young-Hee
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.10 no.3
    • /
    • pp.82-93
    • /
    • 2008
  • In order to ensure a standardized data analysis of the eddy covariance measurements, Hong and Kim's quality control program has been updated and used to process eddy covariance data measured at two levels on the main flux tower at Gwangneung site from January to May in 2005. The updated program was allowed to remove outliers automatically for $CO_2$ and latent heat fluxes. The flag system consists of four quality groups(G, D, B and M). During the study period, the missing data were about 25% of the total records. About 60% of the good quality data were obtained after the quality control. The number of record in G group was larger at 40m than at 20m. It is due that the level of 20m was within the roughness sublayer where the presence of the canopy influences directly on the character of the turbulence. About 60% of the bad data were due to low wind speed. Energy balance closure at this site was about 40% during the study period. Large imbalance is attributed partly to the combined effects of the neglected heat storage terms, inaccuracy of ground heat flux and advection due to local wind system near the surface. The analysis of wind direction indicates that the frequent occurrence of positive momentum flux was closely associated with mountain valley wind system at this site. The negative $CO_2$ flux at night was examined in terms of averaging time. The results show that when averaging time is larger than 10min, the magnitude of calculated $CO_2$ fluxes increases rapidly, suggesting that the 30min $CO_2$ flux is influenced severely by the mesoscale motion or nonstationarity. A proper choice of averaging time needs to be considered to get accurate turbulent fluxes during nighttime.

A Study on the Manufacture of the Artificial Cardiac Tissue Valve (생체판의 제작 및 실험)

  • Kim, Hyoung-Mook;Song, Yo-Jun;Sohn, Kwang-Hyun
    • Journal of Chest Surgery
    • /
    • v.12 no.4
    • /
    • pp.383-394
    • /
    • 1979
  • Treatment of valvular heart disease with valve replacement has been one of the most popular procedures in cardiac surgery recently. Although, first effort was directed toward the prosthetic valve, it soon became popular that bioprosthesis, the valvular xenograft, was prefered in the majority cases. Valvular xenograft has some superiority to the artificial prosthetic valve in some points of thromboembolism and hemolytic anemia, and it also has some inferiority of durability, immunologic reaction and resistance to Infection. Tremendous efforts were made to cover the inferiority with several methods of collection, preservation, and valve mounting of the porcine valve or pericardium of the calf, and also with surgical technique of the valvular xenograft replacement. Auther has collected 320 porcine aortic valves immediately after slaughter, and aortic cusps were coapted with cotton balls in the Valsalva sinuses to protect valve deformity after immersion in the Hanks' solution, and oxidation, cross-linking and reduction procedures were completed after the proposal of Carpentier in 1972. Well preserved aortic valves were suture mounted in the hand-made tissue valve frame of 19, 21, and 23 mm J.d., and also in the prosthetic vascular segment of 19 mm Ld. with 4-0 nylon sutures after careful trimming of the aortic valves. Completed valves were evaluated with bacteriologic culture, pressure tolerance test with tolerane gauge, valve durability test in the saline glycerine mixed solution with tolerance test machine in the speed of 300 rpm, and again with pathologic changes to obtain following results: 1. Bacteriologic culture of the valve tissue in five different preservation method for two weeks revealed excellent and satisfactory result in view of sterilization including 0.65% glutaraldehyde preservation group for one week bacteriologic culture except one tissue with Citobacter freundii in 75% ethanol preserved group. 2. Pressure tolerance test was done with an apparatus composed of V-connected manometer and pressure applicator. Tolerable limit of pressure was recorded when central leaking jet of saline was observed. Average pressure tolerated in each group was 168 mmHg in glutaraldehyde, 128 mmHg in formaldehyde, 92 mmHg in Dakin's solution, 48 mmHg in ethylene oxide gas, and 26 mmHg in ethanol preserved group in relation to the control group of Ringer's 90 mmHg respectively. 3. Prolonged durability test was performed in the group of frame mounted xenograft tissue valve with 300 up-and-down motion tolerance test machine/min. There were no specific valve deformity or wearing in both 19, 21, and 23 mm valves at the end of 3 months (actually 15 months), and another 3 months durability test revealed minimal valve leakage during pressure tolerance test due to contraction deformity of the non-coronary cusp at the end of 6 months (actually 30 months) in the largest 23 mm group. 4. Histopathologic observation was focussed in three view points, endothelial cell lining, collagen and elastic fiber destructions in each preservation methods and long durable valvular tolerance test group. Endothel ial cell lining and collagen fiber were well preserved in the glutaraldehyde and formaldehyde treated group with minimal destruction of elastic fiber. In long durable tolerance test group revealed complete destruction of the endothelial cell lining with minimal destruction of the collagen and elastic fiber in 3 month and 6 month group in relation to the time and severity. In conclusion, porcine xenograft treated after the proposal of Carpentier in 1972 and preserved in the glutaraldehyde solution was the best method of collection, preservation and valve mounting. Pressure tolerance and valve motion tolerance test, also, revealed most satisfactory results in the glutaraldehyde preserved group.

  • PDF

Gait Analysis of a Pediatric-Patient with Femoral Nerve Injury : A Case Study (대퇴신경 손상 환아의 보행분석 : 사례연구)

  • Hwang, S.H.;Park, S.W.;Son, J.S.;Park, J.M.;Kwon, S.J.;Choi, I.S.;Kim, Y.H.
    • Journal of Biomedical Engineering Research
    • /
    • v.32 no.2
    • /
    • pp.165-176
    • /
    • 2011
  • The femoral nerve innervates the quadriceps muscles and its dermatome supplies anteromedial thigh and medial foot. Paralysis of the quadriceps muscles due to the injury of the femoral nerve results in disability of the knee joint extension and loss of sensory of the thigh. A child could walk independently even though he had injured his femoral nerve severely due to the penetrating wound in the medial thigh. We measured and analyzed his gait performance in order to find the mechanisms that enabled him to walk independently. The child was eleven-year-old boy and he could not extend his knee voluntarily at all during a month after the injury. His gait analysis was performed five times (GA1~GA5) for sixteen months. His temporal-spatial parameters were not significantly different after the GA2 or GA3 test, and significant asymmetry was not observed except the single support time in GA1 results. The Lower limb joint angles in affected side had large differences in GA1 compared with the normal normative patterns. There were little knee joint flexion and extension motion during the stance phase in GA1 The maximum ankle plantar/dorsi flexion angles and the maximum knee extension angles were different from the normal values in the sound side. Asymmetries of the joint angles were analyzed by using the peak values. Significant asymmetries were found in GA1with seven parameters (ankle: peak planter flexion angle in stance phase, range of motion; ROM, knee: peak flexion angles during both stance and swing phase, ROM, hip: peak extension angle, ROM) while only two parameters (maximum hip extension angle and ROM of hip joint) had significant differences in GA5. The mid-stance valleys were not observed in both right and left sides of vertical ground reaction force (GRF) in the GA1, GA2. The loading response peak was far larger than the terminal stance peak of vertical ground reaction curve in the affected side of the GA3, GA4, GA5. The measured joint moment curves of the GA1, GA2, GA3 had large deviations and all of kinetic results had differences with the normal patterns. EMG signals described an absence of the rectus femoris muscle activity in the GA1 and GA2 (affected side). The EMG signals were detected in the GA3 and GA4 but their patterns were not normal yet, then their normal patterns were detected in the GA5. Through these following gait analysis of a child who had selective injuries on the knee extensor muscles, we could verify the actual functions of the knee extensor muscles during gait, and we also could observe his recovery and asymmetry with quantitative data during his rehabilitation.

Combined Reconstruction of Posterior Cruciate Ligament and Posterolateral Corner with a Fresh Frozen Achilles Tendon Allograft (한 개의 신선동결 동종아킬레스건을 이용한 후방십자인대 및 후외방구조의 동시 재건술)

  • Kyung, Hee-Soo;Oh, Chang-Wug;Lee, Hyun-Joo;Ihn, Joo-Chul
    • Journal of Korean Orthopaedic Sports Medicine
    • /
    • v.8 no.2
    • /
    • pp.102-108
    • /
    • 2009
  • Purpose: The purpose of this study is to report a result of the technique that reconstruct posterior cruciate ligament (PCL) and posterolateral corner (PLC) simultaneously using a fresh-frozen Achilles tendon allograft. Materials and Methods: Forty two patients (45 legs) underwent PCL and PLC reconstruction were included. There were 38 males and 4 females. Mean age was 39 years. Used graft was a fresh frozen Achilles tendon allograft, which was divided by two size, larger one (${\emptyset}$ 10 mm) for PCL reconstruction and smaller one (${\emptyset}$ 8 mm) for PLC reconstruction. Arthroscopic reconstruction of the PCL was performed using transtibial, single incision, and single bundle technique with 10mm fresh frozen Achilles allograft tendon first. After PCL reconstruction, reconstruction procedure for posterolateral instability was performed using modified figure of "8" technique using smaller gtaft. For clinical evaluation, range of motion, posterior drawer test, varus stress test, prone external rotation (dial) test, Lysholm score, Tegner activity scale and posterior stress radiograph were used. Mean follow up period was 25 months. Results: Preoperatively posterior drawer test was 5 cases in grade II and 40 cases in grade III posterior instability. At final follow-up 22 cases returned within normal condition, 18 cases grade I and 5 cases grade II posterior instability. Though all patients showed positive result over 10 degrees in dial and varus stress test preoperatively, but only 9 cases showed positive both test at final follow-up. The range of motion deficit over $10^{\circ}$ flexion was 3 cases. Lysholm score was improved from mean 50 preoperatively to mean 83(p<0.05) and Tegner activity scale improved from mean 2.1 preoperatively to mean 4.6(p<0.05). In posterior stress radiographs, posterior displacement was improve from mean 16mm preoperatively to 4.1mm after treatment(p<0.05). All patients had improved compared to their pre-operative status as measured by physical examination such as posterior drawer test, varus stress test, dial test. Conclusion: We had successful results by combined reconstruction of the PCL & PLC with a fresh frozen Achilles tendon allograft in patients with PCL and posterolateral rotatory instability at a time.

  • PDF

Objective Identification of Human Sperm Hyperactivation by Computerized Sperm Motion Analysis (Computerized Sperm Motility Analyzer를 이용한 Human Sperm의 Hyperactivated Motility의 객관적 관찰에 관한 연구)

  • Lee, Hee-Kyung;Lee, Chan;Kim, Hyun-Sook;Kim, Young-Tae;Kim, Sun-Haeng;Ku, Pyoung-Sahm
    • Clinical and Experimental Reproductive Medicine
    • /
    • v.21 no.1
    • /
    • pp.1-11
    • /
    • 1994
  • The occurrence and time course of capacitation, acrosomal loss, and hyperactivated motility require quantitative definition in order to characterize fertile human sperm. Recently the method has been developed to estimate the quality of spermatozoa by using kinematic parameters such as curvilinear velocity(VCL), average path velocity(VAP), linearity(LIN), straightness(STR), amplitude of lateral head displacement(ALH), and beat cross frequence(BCF) from Computer Assisted Sperm Analysis (CASA). In this study, using the Hamilton Thorn motility analyzer HTM 2030(Hamilton Thorn Research, Beverly, MA), we attempted to identify the spermatozoa with hyperactivated motility (HA) objectively and to monitor hyperactivation of human spermatozoa during incubation in capacitating media and after treatment of calcium ionophore as compared with acrosome status. And we examined whether HA are related to the result of SPA. Semen samples obtained from 16 healthy men were prepared by swim up technique and preincubated in a capacitating media(modified BWW medium) for 5 hours and treated with calcium ionophore solution. The acrosome reaction was detected with PSA-FITC labelling of the acrosome and in vitro sperm ferilizing capacity was assessed by the zona free hamster ovum penetration assay (SPA). The incidence of hyperactivated sperm was 2.6% in fresh semen, 14.3% of the swim up population, 13.7% after 5h of incubation. Significant increase of percentage of hyperactivated sperm was observed after the incubation (p<0.05) but after treatment, no significant changes of percentage of hyperactivated sperm(l1.8%) in contrast to significant rise in the percentage of acrosome reacted cells. Correlation analysis failed to show any significant relationship between the percentage of sperm with HA and SPA score. In conclusion, although no direct correlations were found between the results of SPA and HA, hyperactivation of sperm is associated with capacitation and monitoring hyperactivated sperm will be expected as a method of evaluating the functional quality of sperm such as SPA.

  • PDF

A STUDY ON THE CHUMSUNGDAE'S FIGURES AND FUNCTIONS (첨성대 수치와 역할에 대한 연구)

  • Kim, Kwang-Tae
    • Publications of The Korean Astronomical Society
    • /
    • v.28 no.2
    • /
    • pp.25-36
    • /
    • 2013
  • Chumsungdae is an ancient astronomical observatory whose main role was doing 'chunmoon'. It was administrate by a royal advisory agency on state affairs. The observers observed the heaven on the observatory platform, recorded peculiar events, and watched and interpreted the signs displayed in the heaven. Chumsungdae is an stonemasonry which represents almanac principles with its peculiar shapes and the numbers of strata and stones. The numbers were thoroughly invented to match exactly the almanac constants. Chumsungdae is comprised largely of three main parts, namely the square base, the stratified cylindrical body, and the top #-shaped stonework, and the total number of stones is 404. The number of the strata (27) and the height of the cylindrical body (27 尺) stand for the days in a sidereal month (27.3 days), which implies that the motion of the Moon with respect to the stars was given more priority than to the Sun at that time of geocentricism. And the cylindrical body was thoroughly designed to consist of 365 stones, which is of course the number of days in a solar year. In addition, there are 12 strata each under and above the south entrance and this in sum makes the 24 divisions of the year. Also there is 182 stones below the 13th stratum and this represents the number of days in the winter ~ summer solstice period, and the rest 183 stones the vice versa. The #-shaped top stonework was aligned in such a way that one of the diagonals points the direction of sunrise on the winter solstice. The square base also layed with the same manner. The south entrance was built 16 degrees SE, and the upright direction of the right pillar stone coincides with the meridian circle. This was a kind of built-in standard meridian circle facilitating the observations. In a symbolic sense, Chumsungdae was thought as the tunnel reaching the heaven, where the observers wished to be enlightened with the signs and inspirations in need. With the craftsmanship and skill, the builder reinforced the stratified cylindrical body with two sets of #-shaped beam stones, piercing at a right angle at 19th ~ 20th and 25th ~ 26th strata. Likewise, by placing the double #-shaped stonework with 8 beam stones on the platform of the observatory, both the stability of the stonemasonry and a guard rail for the nightly observers were securely provided.