• Title/Summary/Keyword: time sharing control

Search Result 246, Processing Time 0.032 seconds

Time Optimal Performance of a Varying-Time Sharing Sequential Paired Thrusting Logic (순차적 가변시간할당 추력방식 최적성능 분석)

  • Oh, Hwa-Suk;Lee, Byung-Hoon;Lee, Bong-Un
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.11 no.3
    • /
    • pp.254-261
    • /
    • 2005
  • Time-optimal performances are analyzed in the sense of inner loop. A varying-time sharing thrusting logic is suggested as a new sequential paired thrusting logic for fast maneuvers of satellites with coupled thruster configuration. Its time-optimal maneuvering performance is compared with two conventional thrusting logics: separate thrusting logic and constant-time sharing sequential paired thrusting logic. It is found that the newly suggested varying-time sharing thrusting logic can be easily implemented by adjusting the conventional constant-time logic with its thrust on-time, while it can reduce the maneuvering time enormously as much as the separate thrusting logic. The performance of the logic is simulated on the agile maneuvering spacecraft model KOMPSAT-II.

Power Conditioning Inverter Controlled by Sinewave Tracking Boost Chopper without DC Smoothing Capacitor Stage

  • Ahmed, Nabil A.;Miyatake, Masafumi;Kang, Tae-Kyung;Lee, Hyun-Woo;Nakaoka, Mutsuo
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.179-185
    • /
    • 2005
  • This paper presents a novel circuit topology of a high efficiency single-phase power conditioner. This power conditioner is composed of time-sharing sinewave absolute pulse width modulated boost chopper with a bypass diode in the first power processing stage and time-sharing sinewave pulse width modulated full-bridge inverter in the second power processing stage operated by time-sharing dual mode pulse pattern control scheme. The unique operating principle of the two power processing stage with time-sharing dual mode sinewave modulation scheme is described with a design example. This paper proposes also a sinewave tracking voltage controlled soft switching PWM boost chopper with a passive auxiliary edge-resonant snubber. The new conceptual operating principle of this novel power conditioner related to new energy utilization system is presented and discussed through the experimental results.

  • PDF

Hybrid Control with Thrusters and Reaction Wheels for Time Optimal Attitude Maneuvers of Spacecraft (위성자세 최소시간 거동을 위한 추력기와 반작용 휠 통합제어)

  • Lee, Byung-Hoon;Lee, Bong-Woon;Oh, Hwa-Suk;Lee, Seon-Ho;Lee, Seung-Wu
    • Proceedings of the KSME Conference
    • /
    • 2003.11a
    • /
    • pp.1578-1583
    • /
    • 2003
  • Time-Optimal solutions for attitude control with reaction wheels as well as with thrusters are studied. The suggested varying-time-sharing ratio thrusting is found to reduce the maneuvering time enormously. The hybrid control such as sequential hybrid and simultaneous hybrid with reaction wheels and thrusters are considered. The results show that simultaneous hybrid method reduces the maneuver time very much. Spacecraft model is KOrea Multi-Purpose SATellite(KOMPSAT)-II, which is being developed by KARI in KOREA as an agile maneuvering satellite.

  • PDF

Implementing Onetime Password based Access Control System for Secure Sharing Service

  • Kang, Namhi
    • International Journal of Internet, Broadcasting and Communication
    • /
    • v.13 no.3
    • /
    • pp.1-11
    • /
    • 2021
  • Development of ICT technologies leads exponential growth of various sharing economy over the last couple of years. The intuitive advantage of the sharing economy is efficient utilization of idle goods and services, but there are safety and security concerns. In this paper, we propose a onetime password based access control system to support secure accommodation sharing service and show the implementation results. To provide a secure service to both the provider and the user, the proposed system issues a onetime access password that is valid only during the sharing period reserved by the user, thereafter access returns to the accommodation owner. Especially, our system provides secure user access by merging the two elements of speaker recognition using voice and a one-time password to open and close the door lock. In this paper, we propose a secure system for accommodation sharing services as a use-case, but the proposed system can be applicable to various sharing services utilizing security-sensitive facilities.

Time Optimal Attitude Maneuver Strategies for the Agile Spacecraft with Reaction Wheels and Thrusters

  • Lee Byung-Hoon;Lee Bong-Un;Oh Hwa-Suk;Lee Seon-Ho;Rhee Seung-Wu
    • Journal of Mechanical Science and Technology
    • /
    • v.19 no.9
    • /
    • pp.1695-1705
    • /
    • 2005
  • Reaction wheels and thrusters are commonly used for the satellite attitude control. Since satellites frequently need fast maneuvers, the minimum time maneuvers have been extensively studied. When the speed of attitude maneuver is restricted due to the wheel torque capacity of low level, the combinational use of wheel and thruster is considered. In this paper, minimum time optimal control performances with reaction wheels and thrusters are studied. We first identify the features of the maneuvers of the satellite with reaction wheels only. It is shown that the time-optimal maneuver for the satellite with four reaction wheels in a pyramid configuration occurs on the fashion of single axis rotation. Pseudo control logic for reaction wheels is successfully adopted for smooth and chattering-free time-optimal maneuvers. Secondly, two different thrusting logics for satellite time-optimal attitude maneuver are compared with each other: constant time-sharing thrusting logic and varying time-sharing thrusting logic. The newly suggested varying time-sharing thrusting logic is found to reduce the maneuvering time dramatically. Finally, the hybrid control with reaction wheels and thrusters are considered. The simulation results show that the simultaneous actuation of reaction wheels and thrusters with varying time-sharing logic reduces the maneuvering time enormously. Spacecraft model is Korea Multi-Purpose Satellite (KOMPSAT)-2 which is being developed in Korea as an agile maneuvering satellite.

Load-Sharing Algorithm using Digital Parallel Communication (디지털 병렬 통신을 이용한 부하분담 알고리즘)

  • Park, Seong-Mi;Kim, Chun-Sung;Lee, Sang-Hyeok;Lee, Sang-Hun;Park, Sung-Jun;Lee, Bae-Ho
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.16 no.1
    • /
    • pp.50-57
    • /
    • 2011
  • In this paper, we proposes a new load-sharing algorithm with a ATmega2560 based digital communication. Proposed algorithm is different from conventional analog method. The high speed communication digital control is performed. To apply the digital communication and real-time control for time-sharing token bus method, we implemented high efficient load-sharing and redundancy. Also this system make down the price by auto ID algorithm and system response is improved by controller's voltage and current integral value sharing. In parallel system prototype, each module have controller and performed load-sharing according to master module integral value. In this paper, we verify the validity of proposed algorithm using PSIM program and prototype.

Secondary Voltage Control for Reactive Power Sharing in an Islanded Microgrid

  • Guo, Qian;Wu, Hongyan;Lin, Liaoyuan;Bai, Zhihong;Ma, Hao
    • Journal of Power Electronics
    • /
    • v.16 no.1
    • /
    • pp.329-339
    • /
    • 2016
  • Owing to mismatched feeder impedances in an islanded microgrid, the conventional droop control method typically results in errors in reactive power sharing among distributed generation (DG) units. In this study, an improved droop control strategy based on secondary voltage control is proposed to enhance the reactive power sharing accuracy in an islanded microgrid. In a DG local controller, an integral term is introduced into the voltage droop function, in which the voltage compensation signal from the secondary voltage control is utilized as the common reactive power reference for each DG unit. Therefore, accurate reactive power sharing can be realized without any power information exchange among DG units or between DG units and the central controller. Meanwhile, the voltage deviation in the microgrid common bus is removed. Communication in the proposed strategy is simple to implement because the information of the voltage compensation signal is broadcasted from the central controller to each DG unit. The reactive power sharing accuracy is also not sensitive to time-delay mismatch in the communication channels. Simulation and experimental results are provided to validate the effectiveness of the proposed method.

A Study on Simultaneous Load Factor of Intelligent Electric Power Reduction System in Korea (한국의 지능형 전력동시부하율 저감시스템에 관한 연구)

  • Kim, Tae-Sung;Lee, Jong-Hwan
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.35 no.1
    • /
    • pp.24-31
    • /
    • 2012
  • This study is designed to predict the overall electric power load, to apply the method of time sharing and to reduce simultaneous load factor of electric power when authorized by user entering demand plans and using schedules into the user's interface for a certain period of time. This is about smart grid, which reduces electric power load through simultaneous load factor of electric power reduction system supervision agent. Also, this study has the following characteristics. First, it is the user interface which enables authorized users to enter and send/receive such data as demand plan and using schedule for a certain period of time. Second, it is the database server, which collects, classifies, analyzes, saves and manages demand forecast data for a certain period of time. Third, is the simultaneous load factor of electric power control agent, which controls usage of electric power by getting control signal, which is intended to reduce the simultaneous load factor of electric power by the use of the time sharing control system, form the user interface, which also integrate and compare the data which were gained from the interface and the demand forecast data of the certain period of time.

Development ofn Sharing Space Access Management System based on Mobile Key and RCU(Room Control Unit) (모바일 키 및 RCU에 기반한 공유공간 출입관리 시스템 개발)

  • Jung, Sang-Joong
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.21 no.4
    • /
    • pp.202-208
    • /
    • 2020
  • Recently, the importance of non-face-to-face has been emphasized due to COVID-19, and the use of sharing spaces is also expanding. The use of uncontact check-in technology for access control of sharing spaces reduces waiting time and optimizes workers' efficiency, resulting in operational cost savings. In this paper, we propose a sharing space access management system based on a mobile key and RCU (Room Control Unit), access to the facility using a mobile key, and monitor the facility using an RCU. Proposal system is for shared accommodation, rental field (residence, sale-selling hotel), shared office, etc. when there is a one-time visitor on a specific day and time, the corresponding password is delivered to the mobile platform to expose and key the existing password. It is supported by a field-adaptive system that can reduce discomfort such as delivery. In order to test the operation of the proposed integrated system, tests were conducted according to scenarios to understand the overall status of the user's reservation, check-in, and check-out, and a 100% success rate was derived for each item by setting performance indicators to prove test reliability.

Modified droop control scheme for load sharing amongst inverters in a micro grid

  • Patel, Urvi N.;Gondalia, Dipakkumar;Patel, Hiren H.
    • Advances in Energy Research
    • /
    • v.3 no.2
    • /
    • pp.81-95
    • /
    • 2015
  • Microgrid, which can be considered as an integration of various dispersed resources (DRs), is characterized by number of DRs interfaced through the power electronics converters. The microgrid comprising these DRs is often operated in an islanded mode. To minimize the cost, reduce complexity and increase reliability, it is preferred to avoid any communication channel between them. Consequently, the droop control method is traditionally adopted to distribute active and reactive power among the DRs operating in parallel. However, the accuracy of distribution of active and reactive power among the DRs controlled by the conventional droop control approach is highly dependent on the value of line impedance, R/X i.e., resistance to reactance ratio of the line, voltage setting of inverters etc. The limitations of the conventional droop control approach are demonstrated and a modified droop control approach to reduce the effect of impedance mis-match and improve the time response is proposed. The error in reactive power sharing is minimized by inserting virtual impedance in line with the inverters to remove the mis-match in impedance. The improved time response is achieved by modifying the real-power frequency droop using arctan function. Simulations results are presented to validate the effectiveness of the control approach.