• 제목/요약/키워드: time of loading

Search Result 2,546, Processing Time 0.036 seconds

Comparison of Virtual Wedge versus Physical Wedge Affecting on Dose Distribution of Treated Breast and Adjacent Normal Tissue for Tangential Breast Irradiation (유방암의 방사선치료에서 Virtual Wedge와 Physical Wedge사용에 따른 유방선량 및 주변조직선량의 차이)

  • Kim Yeon-Sil;Kim Sung-Whan;Yoon Sel-Chul;Lee Jung-Seok;Son Seok-Hyun;Choi Ihl-Bong
    • Radiation Oncology Journal
    • /
    • v.22 no.3
    • /
    • pp.225-233
    • /
    • 2004
  • Purpose: The Ideal breast irradiation method should provide an optimal dose distribution In the treated breast volume and a minimum scatter dose to the nearby normal tissue. Physical wedges have been used to Improve the dose distribution In the treated breast, but unfortunately Introduce an Increased scatter dose outside the treatment yield, pavllculariy to the contralateral breast. The typical physical wedge (FW) was compared with 4he virtual wedge (VW) to do)ermine the difference In the dose distribution affecting on the treated breast and the contralateral breast, lung, heart and surrounding perlpheral soft tissue. Methods and Materials: The data collected consisted of a measurement taken with solid water, a Humanoid Alderson Rando phantom and patients. The radiation doses at the ipsllateral breast and skin, contralateral breast and skin, surrounding peripheral soft tissue, and Ipsllateral lung and heart were compared using the physical wedge and virtual wedge and the radiation dose distribution and DVH of the treated breast were compared. The beam-on time of each treatment technique was also compared Furthermore, the doses at treated breast skin, contralateral breast skin and skin 1.5 cm away from 4he field margin were also measured using TLD in 7 patients of tangential breast Irradiation and compared the results with phantom measurements. Results: The virtual wedge showed a decreased peripheral dose than those of a typical physical wedge at 15$^{\circ}$, 30$^{\circ}$, 45$^{\circ}$, and 60$^{\circ}$. According to the TLD measurements with 15$^{\circ}$ and 30$^{\circ}$ virtual wedge, the Irradiation dose decreased by 1.35$\%$ and 2.55$\%$ In the contralateral breast and by 0.87$\%$ and 1.9$\%$ In the skin of the contralateral breast respectively. Furthermore, the Irradiation dose decreased by 2.7$\%$ and 6.0$\%$ in the Ipsllateral lung and by 0.96$\%$ and 2.5$\%$ in the heart. The VW fields had lower peripheral doses than those of the PW fields by 1.8$\%$ and 2.33$\%$. However the skin dose Increased by 2.4$\%$ and 4.58$\%$ In the Ipsliateral breast. VW fields, In general, use less monitor units than PW fields and shoriened beam-on time about half of PW. The DVH analysis showed that each delivery technique results In comparable dose distribution in treated breast. Conclusion: A modest dose reduction to the surrounding normal tissue and uniform target homogeneity were observed using the VW technique compare to the PW beam in tangential breast Irradiation The VW field is dosmetrically superlor to the PW beam and can be an efficient method for minimizing acute, late radiation morbidity and reduce 4he linear accelerator loading bV decreasing the radiation delivery time.

A Survey on the Break-down and Repair of the Power Tillers in Korea (동력경운기(動力耕耘機) 이용실태(利用實態) 조사분석(調査分析)(II) -고장(故障) 및 수리(修理)에 관(關)하여-)

  • Hong, Jong Ho;Lee, Chai Shik
    • Journal of Biosystems Engineering
    • /
    • v.6 no.1
    • /
    • pp.28-38
    • /
    • 1981
  • A survey has been conducted to investigate the presents of breaks down and repair of power tiller for efficient use. Eight provinces were covered for this study. The results are summarized as follows. A. Frequency of breaks down. 1) Power tiller was breaken down 9.05 times a year and it represents a break down every 39.1 hours of use. High frequency of breaks down was found from the fuel and ignition system. For only these system, the number of breaks down were 2.02 and it represents 23.3% among total breaks down. It was followed by attachments, cylinder system, and traction device. 2) For the power tiller which was more than six years old, breaks down accured 37.7 hours of use and every 38.6 hours for the power tiller which was purchased in less than 2 years. 3) For the kerosene engine power tiller, breaks down occured every 36.8 hours of use, which is a higher value compared with diesel engine power tiller which break down every 42.8 hours of use. The 8HP kerosene engine power tiller showed higher frequency of break down compared with any other horse power tiller. 4) In October, the lowest frequency of break down was found with the value of once for every 51.5 hours of use, and it was followed by the frequency of break down in June. The more hours of use, the less breaks down was found. E. Repair place 1) 45.3% among total breaks down of power tiller was repaired by the owner, and 54.7% was repaired at repair shop. More power tiller were repaired at repair shop than by owner of power tiller. 2) The older the power tiller is, the higher percentage of repairing at the repair shop was found compared with the repairing by the owner. 3) Higher percentage of repairing by the owner was found for the diesel engine power tiller compared with the kerosene engine power tiller. It was 10 HP power tiller for the kerosene power tiller and 8 HP for the diesel engine power tiller. 4) 66.7% among total breaks down of steering device was repaired by the owner. It was the highest value compared with the percentage of repairing of any other parts of power tiller. The lowest percentage of repairing by owner was found for the attachments to the power tiller with the value of 26.5%. C. Cause of break down 1) Among the total breaks down of power tiller, 57.2% is caused by the old parts of power tiller with the value of 5.18 times break down a year and 34.7% was caused by the poor maintenance and over loading. 2) For the power tiller which was purchased in less than two years, more breaks down were caused by poor maintenance in comparison to the old parts of power tiller. 3) For the both 8-10 HP kerosene and diesel engine power tiller, the aspects of breaks down was almost the same. But for the 5 HP power tiller, more breaks down was caused by over loading in comparison to the old parts of power tiller. 4) For the cylinder system and traction device, most of the breaks down was caused by the old parts and for the fuel and ignition system, breaks down was caused mainly by the poor maintenance. D. Repair Cost 1) For each power tiller, repair cost was 34,509 won a year and it was 97 won for one hoar operation. 2) Repair cost of kerosene engine power tiller was 40,697 won a year, and it use 28,320 won for a diesel engine power tiller. 3) Average repair cost for one hour operation of kerosene engine power tiller was 103 won, and 86 won for a diesel engine power tiller. No differences were found between the horse power of engines. 4) Annual repair cost of cylinder system was 13,036 won which is the highest one compared with the repair cost of any other parts 362 won a year was required to repair the steering device, and it was the least among repair cost of parts. 5) Average cost for repairing the power tiller one time was 3,183 won. It was 10,598 won for a cylinder system and 1,006 won for a steering device of power tiller. E. Time requirement for repairing by owner. 1) Average time requirements for repairing the break down of a power tiller by owner himself was 8.36 hours, power tiller could not be used for operation for 93.58 hours a year due to the break down. 2) 21.3 hours were required for repairing by owner himself the break down of a power tiller which was more than 6 years old. This value is the highest one compared with the repairing time of power tiller which were purchased in different years. Due to the break down of the power tiller, it could not be used for operation annually 127.13 hours. 3) 10.66 hours were required for repairing by the owner himself a break down of a diesel engine power tiller and 6.48 hours for kerosene engine power tiller could not be used annually 99.14 hours for operation due to the break down and it was 88.67 hour for the diesel engine power tiller. 4) For both diesel and kerosene engine power tiller 8 HP power tiller required the least time for repairing by owner himself a break down compared with any other horse power tiller. It was 2.78 hours for kerosene engine power tiller and 8.25 hours fur diesel engine power tiller. 5) For the cylinder system of power tiller 32.02 hours were required for repairing a break down by the owner himself. Power tiller could not be used 39.30 hours a year due to the break down of the cylinder system.

  • PDF

LONGEVITY AND FAILURE ANALYSIS OF FIXED RESTORATIONS SERVICED IN KOREA (국내에서 제작된 고정성 보철물의 수명과 실패 요인 및 양상)

  • Shin Woo-Jin;Jeon Young-Sik;Lee Keun-Woo;Lee Ho-Yong;Han Dong-Hoo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.43 no.2
    • /
    • pp.158-175
    • /
    • 2005
  • Statement of problem. Every effort has been continually made to obtain objectivity in measuring the longevity of fixed restorations, such as by establishing unified judgement standard for deciding success and adopting statistical method that analyzes the data of successful and failed cases at the same time. In Korea, however desired level of development has not to be made in this field yet. Purpose. This study, adopting California Dental Association (CDA) quality evaluation system, established objective standard for deciding success, and inferred the longevity of fixed restorations and their failure analysis through adopting Kaplan-Meier survival analysis. Material and method. In order to assess the longevity of flxed restorations serviced in Korea and causes of failure, a total of 1109 individuals (aged 15-74, 716 women and 393 men loaded with 2551 unit fixed restorations, and 1934 abutments) who lived in Kyung-In Province were examined and the findings were as follows : Results. 1. Length of service of fixed restorations serviced in Korea was 6.86$\pm$0.15 yr (mean), 5.5 yr (median), and the rate of success was 65.82% in 5 year survival, and 21.15% in 10 year survival. 2. When there was patient's need for replacing old prosthetics, longevity of fixed restorations was 7.51$\pm$0.27 yr (mean), 7 yr (median), and the rate of success was 61.08% in 5 year survival, and 17.57% in 10 year survival. 3. Longevity of fixed restorations was longest in the over-sixty age group(9.21$\pm$0.66) and that of the teen age group(3.39$\pm$0.28) was shortest (p<0.05). 4. Longevity of fixed restorations of women (7.38$\pm$0.18 years) was longer than that of men (6.00$\pm$0.26) (p<0.05). 5. As for the provider factor (such as unlicensed performers, university hospitals, and private clinic), there was no statistically significant difference in longevity of fixed restorations. 6. Defective margin (34.78%). periodontal disease (12.15%), periapical involvement (11.73%), was the most frequent causes of failure and poor esthetics group showed the longest life above all (p<0.05). Actual frequent causes of failure after removing old prosthetics were defective margin, periapical involvement, periodontal disease and uncemented restoration. In 75.67% of the cases, abutment state after removing old prosthetics was good enough for loading another prosthetics. 7. There was found to have statistically significant influence between longevity of single crown (6.35$\pm$0.20 yr) and that of 3 unit fixed restorations (7.60$\pm$0.30 y) (p<0.05). In each case the most frequent cause of failure was defective margin. 8. The number of cantilever pontic, pontic/abutment ratio, oral hygiene status were found to have no statistically significant influence on longevity of fixed restorations in all groups (p>0.05). 9. Longevity of fixed restorations made of non precious metal was longest (9.60$\pm$0.40 yr) semi precious and precious trailing behind(p<0.05). 10. Group function group (37.04%) and partial group function group (44.62%) were predominant in frequency but showed no correlation between them and among different types of occlusal plane and different types of occlusal surface (p>0.05). 11. Longevity of fixed restorations was longest in the centric interference group(9.35$\pm$0.62) (p<0.05) among different types of occlusal interference. Conclusion. We found that longevity of fixed restorations serviced in Korea is affected by age, gender and type of material, and that most frequent cause of failure is defective margin. In order to assess the accurate longevity of axed restorations, unified research design. overcoming inter-observer difference and establishing the objective research items are needed. Furthermore, it is thought that prospective approach through thorough study and regular follow-ups is needed just from the start of research. Nationwide detailed studies on length of service of fixed restorations manufactured in Korea are hoped to be conducted hereafter.

A Study on the Consumer's Service Quality Perception Based on the Types of Life-style (소비자의 라이프스타일에 따른 서비스품질 지각 차이에 관한 연구)

  • Park, Yoon-Seo;Lee, Seung-In;Choi, In
    • Journal of Global Scholars of Marketing Science
    • /
    • v.19 no.2
    • /
    • pp.53-67
    • /
    • 2009
  • For the last decades, service quality has been studied as one of the most important tools for a service company to compete with the other companies. Based on these past researches, it has been agreed that the service quality is a basic and powerful tool to create the competitive advantage. Due to similar reason, many service marketing practitioners have been also focused on the service quality to retain the existing consumers and collect the new consumers. However, service quality is subjectively perceived by individual consumers. Consumer evaluation of service quality can be different from each other. Especially consumers with one life-style may evaluate the service quality differently from the consumers with the other life-styles. Therefore we need to know whether there are differences in service quality perception on the categories of life-style. Life-style refers to a distinctive mode of living in its aggregate and broadest sense. It embodies the patterns that were developed and emerged from the dynamics of living in a society. Since the concept of life-style and its relationship to marketing was introduced in 1963 by William Lazer, methods of measuring the life-style and their application have been developed. Life-style has been usually used to segment the marketplace because it offers marketers a unique and important view of the market. When Life-style is combined with clustering methods, life-style segmentation can generate identifiable whole persons rather than isolated fragment. Life-style segmentation begins with people instead of products and classifies them into different life-style types, each characterized by a unique style of living based on a wide range of activities, interests, and opinions(Plummer, 1974). In this study we applies the life-style segmentation based on the AIO(Activities, Interests, and Opinions) to the consumers of the large discount stores. In Korea, the large discount store market has entered into maturity stage so that the market differentiation strategy is becoming a more critical issue to the marketing practitioners. One of the most important tools to differentiate from the competitors in large discount store market is continuously to provide service of better quality than competitors. This study tries to find answers about the following questions: 1) How can we categorize the consumer life-styles in the large discount store? 2) What are the characteristics of the categorized groups? 3) Are there any differences in service quality perception among the consumers with different life-styles 4) Are there any differences in consumer behavior among them in the large discount store? For the purpose, we collected survey data from consumers and analyzed the data with the SPSS package where we had $X^2$-test, factor analysis, ANOVA, MANOVA, and cluster analysis. The survey was made during one month in the April of 2008. Among the collected 306 copies of questionnaires, 281 copies were chosen as the effective samples for empirical analysis except 25 copies with wrong responses. To identify the life-style patterns, we used the measures employed by Kim and Kwon(1999), where 44 items on a seven-point scale were used to measure factors of the life-style patterns. The Principal Component Method was used for factor extraction, and the VARIMAX orthogonal factor rotation was employed. The 7 items showing low factor loading were eliminated. The results of the factor analysis suggested that nine factors of the life-style patterns were identified as follows: 1) the equality-of-sexes and pursuit-of-independence tendency 2) self-management tendency 3) sociable tendency 4) self-display tendency 5) degree of a dilettante life 6) pursuit-of-information tendency 7) bargain hunter tendency 8) TV preference tendency 9) pursuit-of-leisure tendency. Next, after the K-means cluster analysis was performed with nine factors of the life-style patterns, the life-styles of the respondents were classified into four groups which are named as the 'progressive practicality-oriented group', 'positive success-oriented group', 'sociable ostentation-oriented group', 'stable conservation-oriented group'. The analysis results for usage behavior between the market segments showed statistically significant differences in the frequency of usage, duration time in the store, consumer satisfaction, and loyalty. Also, we tried to investigate whether the large discount store consumers differently perceive the quality of service based upon the types of life-style. To measure the service quality of large discount store, we adapted several measurement models measuring the service quality such as SERVPERF, BCP, R-SERVPERF, R-BCP. MANOVA and One-Way ANOVA were performed to confirm the difference in service quality perception based on the market segments. The results have also shown significant differences between life-style types in service quality perception. These findings show that the large discount store marketers should consider consumer life-style as one of the most important market segments for marketing and understand the difference in service quality perception between life-style types. Our findings give important implications to marketers of large discount stores as well as life-style researchers. First, this study showed there were significant differences in consumer's service quality perception and usage behavior between the types of life-style. It provides evidence that the life-style approach can be a important basis in segmenting the large discount store market and will make consumers perceive the service quality high. Second, most previous researches on service quality have been in aggregate level. However, our results imply that the future research on service quality have to focus on segment level.

  • PDF

The Effects of Aminophylline on the Superoxide Anion Generation of Neutrophils from Established Human Sepsis Caused by Acute Pneumonia (급성 폐렴에 의한 패혈증 환자에서 Aminophylline이 혈중 호중구의 과산화물 음이온 유리에 미치는 영향)

  • Kim, Yong-Hoon;Park, Jun-Young;Cha, Mi-Kyong;Lee, Sang-Moo;Kim, Hyeon-Tae;Uh, Soo-Taek;Chung, Yeon-Tae;Park, Choon-Sik
    • Tuberculosis and Respiratory Diseases
    • /
    • v.40 no.1
    • /
    • pp.16-22
    • /
    • 1993
  • Background: The Microbicidal and cytotoxic activities of neutrophils are to a large extent dependent on a burst of oxidative metabolism which generates superoxide anion, hydrogen peroxide, and other reactive products of oxygen. The respiratory burst of PMN is initiated by intracellular calcium mobilization that follows immune or particular stimulation and is very sensitive to modulation by c-AMP or adenosine. Despite its antagonism against adenosine, earlier study has demonstrated potent theophylline inhibition of the PMN respiratory burst at variable ranges of blood concentrations of theophylline in the healthy normal volunteers and in the septic animals pretreated or early post-treated with aminophylline (AMPH) or pentoxifylline. However it is unclear whether theophylline inhibits the superoxide generation or not in the established human sepsis caused by acute pneumonia, as taking into consideration of the fact that full activation of neutrophils have occurred within minutes after the septic insult in the animal experiments. Methods: We measured the $O_2$ generation of peripheral arterial neutrophils obtained from 11 human septic subjects caused by acute pneumonia before and 1 hour after completion of continuous AMPH infusion. Patients were identified and studied within 48 hour of admission. All subjects were administered an intravenous loading and maintenance dose of AMPH. The generation of $O_2$ was measured at a discrete time point (60 min) by the reduction of ferricytochrome c.PMA (10 ${\mu}g/ml$) was used as a stimulating agent. PMNs were isolated at a concentration of $2{\times}10^6$ cells/ml. The arterial oxygen tension, blood pressure and heart rates were also checked to evaluate the systemic effects of AMPH in the acute pneumonia. Results: The mean serum concentration of AMPH at 60 minutes was $8.8{\pm}0.6{\mu}g/ml$. Sixty minutes after AMPH infusion the generatition of $O_2$ was decreased from $0.076{\pm}0.034$ to $0.013{\pm}0.004$(OD) (p<0.05) and from $0.177{\pm}0.044$ to $0.095{\pm}0.042$(OD) (p<0.01) in the resting and stimulated PMNs respectively. $PaO_2$ was not changed after AMPH infusion. Conclusion: AMPH may compromise host defense by significant inhibition of neutrophil release of superoxide anion and it had no effect on improving $PaO_2$ in the acute pneumonia.

  • PDF

A multicenter clinical study of installed US II Plus/GS II Osstem implants after bone graft (골 이식술 후 Osstem Implant (US II Plus/GS II)의 다기관 임상연구)

  • Chung, Kwang;Oh, Chul-Jung;Ha, Ji-Won;Kook, Min-Suk;Park, Hong-Ju;Oh, Hee-Kyun;Kim, Su-Gwan;Kim, Young-Kyun;Kim, Woo-Cheol
    • The Journal of the Korean dental association
    • /
    • v.50 no.12
    • /
    • pp.743-754
    • /
    • 2012
  • urpose : The purpose of this study was to evaluate the US II plus/GS II Osstem$^{(R)}$ implants through the study for the clinical success rate during the installation of the Osstem¢Á implants after bone graft. Materials and Methods : This study was researched in the 4 medical institutions: Chonnam National University, Chosun University, Bundang Seoul National University Hospital, and FM dental clinic from May, 2002 to September, 2009. Based on the total number of 60 patients whose treatment was the installation of the US II plus/GS II Osstem¢Á implants after bone graft, we evaluated success rate of implants. We analysis the distribution of patient's age and gender, edentulous area, bone type, fixture length and diameter, installation and loading time, donor site, bone graft material and method, antagonistic teeth, and survival and success rate. From these analyses we got the following results. Results : 1. In this study, the total number of patients who have been installed with US II plus implant was 27, and total of 52 implants were installed. The average age was 38.9, with 16 male, and 11 female patients. 2. The total number of patients who have been installed with GS II implant was 33, and total of 54 implants were installed. The average age was 49.7, with 24 male, and 9 female patients. 3. As for bone graft method, either autogenous bone or a mix of autogenous and heterogenous bone was used(88.4%) for US II plus. Chin, iliac, and Maxillary tuberosity were the donor sites for autogenous bone graft, and onlay method of bone graft was performed. 4. Allogenic bone or a mix of autogenous and heterogenous bone was used(77.8%) for GS II. Chin, ramus, and tibia were the donor sites for autogenous bone graft, and GBR method of bone graft was performed. 5. The duration from the installation of implants to setting of final prosthesis was average of 16 months and 10 months for US II plus and GS II respectively. Also, the final follow up period was average of 31 months and 28 months respectively. During this period, one GS II implant was removed from 1 patient due to failure of early osteointegration. 6. The survival rates were 100% and 98.1%, and success rates were 94.2% and 94.4% for US II plus and GS II implant respectively. Conclusion : On the evaluation of our clinical study, both US II plus and GS II Osstem¢Á implants showed the excellent clinical results after bone graft.

Production of $[^{18}F]F_2$ Gas for Electrophilic Substitution Reaction (친전자성 치환반응을 위한 $[^{18}F]F_2$ Gas의 생산 연구)

  • Moon, Byung-Seok;Kim, Jae-Hong;Lee, Kyo-Chul;An, Gwang-Il;Cheon, Gi-Jeong;Chun, Kwon-Soo
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.40 no.4
    • /
    • pp.228-232
    • /
    • 2006
  • Purpose: electrophilic $^{18}F(T_{1/2}=110\;min)$ radionuclide in the form of $[^{18}F]F_2$ gas is of great significance for labeling radiopharmaceuticals for positron omission tomography (PET). However, its production In high yield and with high specific radioactivity is still a challenge to overcome several problems on targetry. The aim of the present study was to develop a method suitable for the routine production of $[^{18}F]F_2$ for the electrophilic substitution reaction. Materials and Methods: The target was designed water-cooled aluminum target chamber system with a conical bore shape. Production of the elemental fluorine was carried out via the $^{18}O(p,n)^{18}F$ reaction using a two-step irradiation protocol. In the first irradiation, the target filled with highly enriched $^{18}O_2$ was irradiated with protons for $^{18}F$ production, which were adsorbed on the inner surface of target body. In the second irradiation, the mixed gas ($1%[^{19}F]F_2/Ar$) was leaded into the target chamber, fellowing a short irradiation of proton for isotopic exchange between the carrier-fluorine and the radiofluorine absorbed in the target chamber. Optimization of production was performed as the function of irradiation time, the beam current and $^{18}O_2$ loading pressure. Results: Production runs was performed under the following optimum conditions: The 1st irradiation for the nuclear reaction (15.0 bar of 97% enriched $^{18}O_2$, 13.2 MeV protons, 30 ${\mu}A$, 60-90 min irradiation), the recovery of enriched oxygen via cryogenic pumping; The 2nd irradiation for the recovery of absorbed radiofluorine (12.0 bar of 1% $[^{19}F]fluorine/argon$ gas, 13.2 MeV protons, 30 ${\mu}A$, 20-30 min irradiation) the recovery of $[^{18}F]fluorine$ for synthesis. The yield of $[^{18}F]fluorine$ at EOB (end of bombardment) was achieved around $34{\pm}6.0$ GBq (n>10). Conclusion: The production of $^{18}F$ electrophilic agent via $^{18}O(p,n)^{18}F$ reaction was much under investigation. Especially, an aluminum gas target was very advantageous for routine production of $[^{18}F]fluorine$. These results suggest the possibility to use $[^{18}F]F_2$ gas as a electrophilic substitution agent.

Treatment Level of a Pond System for Ecological Treatment and Recycling of Animal Excreta (생태적 축산폐수 처리 및 재활용 연못시스템의 폐수처리수준)

  • Yang, Hong-Mo;Rhee, Chong-Ouk
    • Korean Journal of Environmental Agriculture
    • /
    • v.17 no.1
    • /
    • pp.70-75
    • /
    • 1998
  • A model of pond system is developed for treatment and recycling of excreta from twenty-five adult dairy cattle. It is composed of wastewater treatment ponds and small fish ponds. Those are three facultative ponds in series; primary-secondary-tertiary pond and these are designed to rear carps without feeding. A pit is constructed at the bottom of primary pond for efficient sludge sedimentation and effective methane fermentation. It is contrived to block into it the penetration of oxygen dissolved in the upper layer of pond water. The excreta from the cattle housed in stalls are diluted by water used for clearing them. The washed excreta flow into the pit. The average yearly $BOD_5$ concentration of influent is 398.7mg/l. That of the effluent from primary, secondary and tertiary pond of the system is 49.18, 27.9, and 19.8.mg/l respectively. Approximate 88, 93, and 95 % of BOD5 are removed in each pond. The mean yearly SS concentration of influent is 360.5 mg/l That of the effluent from each pond is 53.4, 45.7, and32.7mg/l respectively. Approximate 86, 88, and 91% of SS are removed in each pond. The $BOD_5$ concentration of secondary and tertiary pond can satisfy 30mg/l secondary treatment standard. The SS concentration of effluent from tertiary pond, however, is slightly greater than the standard, which results from activities of carps growing in the pond. The average yearly total nitrogen concentration of influent is 206.8mg/l and that of the effluent from each pond is 48.6, 30.8, and 21.0mg/l respectively. Approximate 74, 88, and 90% of total nitrogen are removed in each pond. The mean yearly total phosphorous concentration of influent is 20.7mg/l and that of the effluent from each pond is 5.3, 3.2, and 2.1mg/l respectively. Approximate 97, 98, and 99% of total phosphorous are removed in each pond. The high removal of nitrogen and phosphorous results from active growth of algae in the upper layer of pond water. Important pond design parameters for southern part of Korea -- areal loading of BOD5, liquid depth, hydraulic detention time, free board, and pond arrangement -- are taken up.

  • PDF

Gait Analysis of a Pediatric-Patient with Femoral Nerve Injury : A Case Study (대퇴신경 손상 환아의 보행분석 : 사례연구)

  • Hwang, S.H.;Park, S.W.;Son, J.S.;Park, J.M.;Kwon, S.J.;Choi, I.S.;Kim, Y.H.
    • Journal of Biomedical Engineering Research
    • /
    • v.32 no.2
    • /
    • pp.165-176
    • /
    • 2011
  • The femoral nerve innervates the quadriceps muscles and its dermatome supplies anteromedial thigh and medial foot. Paralysis of the quadriceps muscles due to the injury of the femoral nerve results in disability of the knee joint extension and loss of sensory of the thigh. A child could walk independently even though he had injured his femoral nerve severely due to the penetrating wound in the medial thigh. We measured and analyzed his gait performance in order to find the mechanisms that enabled him to walk independently. The child was eleven-year-old boy and he could not extend his knee voluntarily at all during a month after the injury. His gait analysis was performed five times (GA1~GA5) for sixteen months. His temporal-spatial parameters were not significantly different after the GA2 or GA3 test, and significant asymmetry was not observed except the single support time in GA1 results. The Lower limb joint angles in affected side had large differences in GA1 compared with the normal normative patterns. There were little knee joint flexion and extension motion during the stance phase in GA1 The maximum ankle plantar/dorsi flexion angles and the maximum knee extension angles were different from the normal values in the sound side. Asymmetries of the joint angles were analyzed by using the peak values. Significant asymmetries were found in GA1with seven parameters (ankle: peak planter flexion angle in stance phase, range of motion; ROM, knee: peak flexion angles during both stance and swing phase, ROM, hip: peak extension angle, ROM) while only two parameters (maximum hip extension angle and ROM of hip joint) had significant differences in GA5. The mid-stance valleys were not observed in both right and left sides of vertical ground reaction force (GRF) in the GA1, GA2. The loading response peak was far larger than the terminal stance peak of vertical ground reaction curve in the affected side of the GA3, GA4, GA5. The measured joint moment curves of the GA1, GA2, GA3 had large deviations and all of kinetic results had differences with the normal patterns. EMG signals described an absence of the rectus femoris muscle activity in the GA1 and GA2 (affected side). The EMG signals were detected in the GA3 and GA4 but their patterns were not normal yet, then their normal patterns were detected in the GA5. Through these following gait analysis of a child who had selective injuries on the knee extensor muscles, we could verify the actual functions of the knee extensor muscles during gait, and we also could observe his recovery and asymmetry with quantitative data during his rehabilitation.

A Study on the Optimum Design of Multiple Screw Type Dryer for Treatment of Sewage Sludge (하수슬러지 처리를 위한 다축 스크류 난류 접촉식 건조기의 최적 설계 연구)

  • Na, En-Soo;Shin, Sung-Soo;Shin, Mi-Soo;Jang, Dong-Soon
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.34 no.4
    • /
    • pp.223-231
    • /
    • 2012
  • The purpose of this study is to investigate basically the mechanism of heat transfer by the resolution of complex fluid flow inside a sophisticated designed screw dryer for the treatment of sewage sludge by using numerical analysis and experimental study. By doing this, the result was quite helpful to obtain the design criteria for enhancing drying efficiency, thereby achieving the optimal design of a multiple screw type dryer for treating inorganic and organic sludge wastes. One notable design feature of the dryer was to bypass a certain of fraction of the hot combustion gases into the bottom of the screw cylinder, by the fluid flow induction, across the delicately designed holes on the screw surface to agitate internally the sticky sludges. This offers many benefits not only in the enhancement of thermal efficiency even for the high viscosity material but also greater flexibility in the application of system design and operation. However, one careful precaution was made in operation in that when distributing the hot flue gas over the lump of sludge for internal agitation not to make any pore blocking and to avoid too much pressure drop caused by inertial resistance across the lump of sludge. The optimal retention time for rotating the screw at 1 rpm in order to treat 200 kg/hr of sewage sludge was determined empirically about 100 minutes. The corresponding optimal heat source was found to be 150,000 kcal/hr. A series of numerical calculation is performed to resolve flow characteristics in order to assist in the system design as function of important system and operational variables. The numerical calculation is successfully evaluated against experimental temperature profile and flow field characteristics. In general, the calculation results are physically reasonable and consistent in parametric study. In further studies, more quantitative data analyses such as pressure drop across the type and loading of drying sludge will be made for the system evaluation in experiment and calculation.