• Title/Summary/Keyword: time harmonic

Search Result 853, Processing Time 0.03 seconds

Current Differential Relaying Algorithm for Power Transformer Protection Operating in Conjunction with a CT Compensating Algorithm (보상 알고리즘을 적용한 변압기 보호용 전류차동 계전방식)

  • Kang, Yang-Cheol;Park, Jong-Min;Lee, Mi-Sun;Jang, Sung-Il;Kim, Yong-Gyun;So, Soon-Hong
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.11
    • /
    • pp.1873-1878
    • /
    • 2007
  • Current differential relays may maloperate during magnetic inrush and over-excitation because a significant differential current is produced. To prevent maloperation, the relays adopt some harmonic components included in the differential current. The harmonic restraints may increase the security of a relay but cause the operating time delay of a relay when an internal fault occurs. Moreover, the operating time delay is more increased if a current transformer (CT) is saturated. This paper describes a current differential relaying algorithm for power transformer protection with a compensating algorithm for the secondary current of a CT. The comparative study was conducted with and without the compensating algorithm. The performance of the proposed algorithm was investigated when the measurement CT (C400) and the protection CT (C400) are used. The proposed algorithm can compensate the distorted current of a CT and thus reduce the operating time delay of the relay significantly for an internal fault with CT saturation.

A Novel Interleaving Control Scheme for Boost Converters Operating in Critical Conduction Mode

  • Yang, Xu;Ying, Yanping;Chen, Wenjie
    • Journal of Power Electronics
    • /
    • v.10 no.2
    • /
    • pp.132-137
    • /
    • 2010
  • Interleaving techniques are widely used to reduce input/output ripples and to increase the power capacity of boost converters operating in critical conduction mode. Two types of phase-shift control schemes are studied in this paper, the turn-on time shifting method and the turn-off time shifting method. It is found that although the turn-off time shifting method exhibits better performance, it suffers from sub-harmonic oscillations at high input voltages. To solve this problem, an intensive quantitative analysis of the sub-harmonic oscillation phenomenon is made in this paper. Based upon that, a novel modified turn off time shifting control scheme for interleaved boost converters operating in critical conduction mode is proposed. An important advantage of this scheme is that both the master phase and the slave phase can operate stably in critical conduction mode without any oscillations in the full input voltage range. This method is implemented with a FPGA based digital PWM control platform, and tests were carried out on a two-phase interleaved boost PFC converter prototype. Experimental results demonstrated the feasibility and performance of the proposed phase-shift control scheme.

Characteristics of Time Stepping and Harmonic Finite Element Models for Coastal Hydrodynamic Simulation (연안 수훈력학 모난를 위한 시간진행 및 조화 유한요소모형 특성)

  • 서승원
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.5 no.4
    • /
    • pp.406-413
    • /
    • 1993
  • Among 2-dimensional coastal hydrodynamic finite element models time stepping ADCIRC and STEPM. and harmonic FUNDY and TEA models were compared in order to find out their characteristics and analyze ernr. General feasibility and capability of models were studied by comparing model results with an analytical solution on some reference points and L$_2$norm error in quarter annular domain where analytical solution can be obtained. According to these tests harmonic models FUNDY and TEA were nearly coinciding with analytical solutions and gave better results than time stepping models. STEPM was at least 5 times better than ADCIRC in L$_2$norm error test and it was 7 times worse than harmonic models. It was expected and concluded that these errors might come from phase lag due to cold start condition and nonlinear effect in basic equations of time stepping models.

  • PDF

Characteristics Analysis of Induction Motor by Operation of Non-lineal Loads (비선형 부하의 운전시 유도전동기의 특성 해석)

  • Kim, Jong-Gyeum;Park, Young-Jeen;Lee, Eun-Woong
    • Proceedings of the KIEE Conference
    • /
    • 2006.10b
    • /
    • pp.147-153
    • /
    • 2006
  • Voltage unbalance will be generated by the load unbalance operation such as combination operation of single & three phase load and current unbalance will be more severe by the deteriorated voltage quality. Under the these unbalance conditions, all power electronic converters used in different types of electronic systems can increase harmonic disturbances by injecting harmonic currents directly into the feeder grid of three phase 4-wire. Harmonic current may cause torque to decrease. it may also overheat or become noisy and torque oscillation in the rotor can lead to mechanical resonance and vibration. This paper presents a scheme on the characteristics of induction motor under the combination of linear & non-linear loads at the three phase 4-wire power distribution system by the unbalance and harmonic components. It was able to confirm that the number of torque pulsation decreased and torque ripple values increased by the harmonics that reduction was difficult by five harmonics filters at additional driving time of single-phase non-linear load.

  • PDF

Effect on Molded Case Circuit Breaker of Harmonic Current (고조파 전류가 배선용차단기에 미치는 영향)

  • Yoo, Jae-Geun;Choi, Myung-Il;Park, Chee-Hyun;Son, Jae-Hyun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.9 no.1
    • /
    • pp.53-58
    • /
    • 2008
  • This paper analyze the operating characteristic of MCCB due to the synthesize harmonic current. Four types of MCCBs, divided by the type of operation system and a principle of operation, tested with 200[%] of rated current. The test result nuisance tripping did not occur but the time delay characteristic of the hydraulic magnetic type MCCB is appeared. From the place where the synthesize harmonic content is high it is good the hydraulic magnetic type MCCB not to use.

Thermal Analysis of a High Speed Induction Motor Considering Harmonic Loss Distribution

  • Duong, Minh-Trung;Chun, Yon-Do;Park, Byoung-Gun;Kim, Dong-Jun;Choi, Jae-Hak;Han, Pil-Wan
    • Journal of Electrical Engineering and Technology
    • /
    • v.12 no.4
    • /
    • pp.1503-1510
    • /
    • 2017
  • In this paper, a thermal analysis of a high speed induction motor with a PWM voltage source was performed by considering harmonic loss components. The electromagnetic analysis of the high speed induction motor was conducted using the time-varying finite element method, and its thermal characteristics were carried out using the lump-circuit method. Harmonic losses from tests in the high frequency region were divided into core loss and conductor loss components using various ratios, in order to determine the loss distributions for the thermal analysis. The results from both the calculations and experiment were validated using a high speed induction motor prototype operating at 20,000rpm.

Optimal Placement of Measurements using Genetic Algorithms for Harmonic State Estimation (고조파 상태 추정에 있어서 유전 알고리즘을 이용한 최적 측정위치 선정)

  • Chung, H.H.;Wang, Y.P.;Lee, J.P.;Park, H.C.
    • Proceedings of the KIEE Conference
    • /
    • 2002.07a
    • /
    • pp.298-300
    • /
    • 2002
  • The design of a measurement system to perform Harmonic State Estimation (HSE) is a very complex problem. In particular, the number of available harmonic instruments(Continuous Harmonic Analysis in Real Time : CHART) is always limited. Therefore, a systematic procedure is needed to design the optimal placement of measurement points. This paper presents a new HSE algorithm which is based on an optimal placement of measurement points using Genetic Algorithms (GAs). This HSE has been applied to the New Zealand AC Power System for the validation of the new HSE algorithm. The study results have indicated an economical and effective method for optimal placement of measurement points using GAs in the HSE.

  • PDF

An Optimal Algorithm of Harmonic State Estimation using Immune Algorithm on Power System (IA를 이용한 전력시스템 고조파 상태 추정 최적 알고리즘)

  • Park, I.P.;Wang, Y.P.;Chung, H.H.;Park, H.C.;Ahn, B.C.
    • Proceedings of the KIEE Conference
    • /
    • 2003.07a
    • /
    • pp.92-94
    • /
    • 2003
  • The design of a measurement system to perform Harmonic State Estimation(HSE) is a very complex problem. In particular, the number of available harmonic instruments (Continuous Harmonic Analysis in Real Time : CHART) is always limited. Therefore, a systematic procedure is needed to design the optimal placement of measurement points. This paper presents an optimal algorithm of HSE which is based on an optimal placement of measurement points using Immune Algorithm (IAs). This HSE has been applied to power system for the validation of an optimal algorithm of HSE. The study results have indicated an economical and effective method for optimal placement of measurement points using IAs in the HSE.

  • PDF

A Study on the Optimum Design of Soltless Type PMLSM Using Genetic Algorithm and 3-D Space Harmonic Method (유전 알고리즘과 3차원 공간고조파법을 이용한 Soltless Type PMLSM의 최적설계에 관한 연구)

  • 이동엽;김규탁
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.53 no.8
    • /
    • pp.463-468
    • /
    • 2004
  • This paper was applied space harmonic method as a characteristic analysis technique for slotless PMLSM. There is advantages of active response to the change of design parameters as well as reduction of the calculation time. The method can be overcome disadvantages of finite element analysis that needs long times calculation, repetitions of pre and post-process. In this paper, 3D-space harmonic method was applied to consider the precise description of end turn coil shape and the changes of characteristic according to changes of length of z-axis direction. The thrust of optimal design was performed using genetic algorithm to enhance the thrust which is the disadvantage of slotless type PMLSM. For design parameters, width of permanent magnet, width of coil, width of coil inner and lengths of z-axis direction were selected. For objective functions. thrust per weight. thrust per volume. multi-objective function was selected.

A Study of Harmonics by Arc Furnace Operating for Demand Side Management (수요관리를 위한 아크로 운전 상태에 따른 고조파 연구)

  • Park, Kyung-Ho;Kim, Jae-Chul;Park, Hyun-Teak;Im, Sang-Kug;Oh, Dong-Whan
    • Proceedings of the KIEE Conference
    • /
    • 2003.11a
    • /
    • pp.17-19
    • /
    • 2003
  • Electric arc furnace has consumed plenty of power. Hence electric arc furnace can be expected to use for demand side management. When electric arc furnace use for demand side management, electric arc furnace frequently occur a starting and a stop. Electric arc furnace irregularity change consumption of power. Due to character of time-varing and non-linear, electirc arc furnace has a problem with voltage quality(flicker, harmonics). Producted harmonic in electric art furnace is different any harmonic source because of electric arc furnace peculiar operating. Accordingly, analysis for generated harmonic in electric arc furnace operating is demanded. This paper analyze effect of harmonic by arc furnace operating.

  • PDF