• 제목/요약/키워드: time/temperature control

검색결과 2,357건 처리시간 0.105초

열연 고강도강의 비정상부 온도제어를 위한 LBCC 개발 (LBCC of Transient State for High Strength Steel in Hot Strip Mills)

  • 박철재;윤강섭
    • 제어로봇시스템학회논문지
    • /
    • 제17권4호
    • /
    • pp.382-387
    • /
    • 2011
  • In this paper, a LBCC (Latter Bank Cooling Control) for the high strength steel is proposed to obtain the desirable temperature and the property of the material along the longitudinal direction of the steel on the ROT (Run-Out Table) process. A cooling valve is modeled to analyze the response of the ROT banks. The control concept is derived from a field data, a valve model considering the valve response and a TTT (Time-Temperature Transformation) diagram. The proposed control is verified from the simulation results under the various carbon quantities. It is shown through the field test of the hot strip mill that the deviation of the CT (Coiling Temperature) is considerably decreased by the proposed temperature control.

실시간 제어를 위한 고속 열처리 공정에서 웨어퍼 온도 분포 추정 기법 (A Prediction Method of Temperature Distribution on the Wafer for Real-Time Control in a Rapid Thermal Process System)

  • 심영태;이석주;김학배
    • 제어로봇시스템학회논문지
    • /
    • 제6권9호
    • /
    • pp.831-835
    • /
    • 2000
  • The uniformity of themperature on a wafer is a wafer is one the most important parameters to conterol the RTF(Rapid Thermal Process) with proper input signals. It is impossible to achieve the uniformity of temperature without the exact estimation of temperature ar all points on the wafer. There fore, it is difficult to understand the internal dynamics as well as the structural complexities of the RTP, which is aprimary obstacle to measure the distributed temperatures on the wafer accurately. Furthermore, it is also hard to accomplish desirable estimation because only a few pyrometers are available in the general equipments. In the paper, a thermal model based on the chamber grometry of the AST SHS200 RTP system is developed to effectively control the thermal uniformity on the wafer. First of all, the estimation method of one-point measurement is developed, which is properly extended to the case of multi-point measurements. This thermal model is validated through simulation and experiments. The proposed work can be utilized to building a run-by -run or a real-time control of the RTP.

  • PDF

Intelligent Tuning of the Two Degrees-of-Freedom Proportional-Integral-Derivative Controller On the Distributed Control System for Steam Temperature Control of Thermal Power Plant

  • Dong Hwa Kim;Won Pyo Hong;Seung Hack Lee
    • KIEE International Transaction on Systems and Control
    • /
    • 제2D권2호
    • /
    • pp.78-91
    • /
    • 2002
  • In the thermal power plant, there are six manipulated variables: main steam flow, feedwater flow, fuel flow, air flow, spray flow, and gas recirculation flow. There are five controlled variables: generator output, main steam pressure, main steam temperature, exhaust gas density, and reheater steam temperature. Therefore, the thermal power plant control system is a multinput and output system. In the control system, the main steam temperature is typically regulated by the fuel flow rate and the spray flow rate, and the reheater steam temperature is regulated by the gas recirculation flow rate. However, strict control of the steam temperature must be maintained to avoid thermal stress. Maintaining the steam temperature can be difficult due to heating value variation to the fuel source, time delay changes in the main steam temperature versus changes in fuel flow rate, difficulty of control of the main steam temperature control and the reheater steam temperature control system owing to the dynamic response characteristics of changes in steam temperature and the reheater steam temperature, and the fluctuation of inner fluid water and steam flow rates during the load-following operation. Up to the present time, the Proportional-Integral-Derivative Controller has been used to operate this system. However, it is very difficult to achieve an optimal PID gain with no experience, since the gain of the PID controller has to be manually tuned by trial and error. This paper focuses on the characteristic comparison of the PID controller and the modified 2-DOF PID Controller (Two-Degrees-Freedom Proportional-Integral-Derivative) on the DCS (Distributed Control System). The method is to design an optimal controller that can be operated on the thermal generating plant in Seoul, Korea. The modified 2-DOF PID controller is designed to enable parameters to fit into the thermal plant during disturbances. To attain an optimal control method, transfer function and operating data from start-up, running, and stop procedures of the thermal plant have been acquired. Through this research, the stable range of a 2-DOF parameter for only this system could be found for the start-up procedure and this parameter could be used for the tuning problem. Also, this paper addressed whether an intelligent tuning method based on immune network algorithms can be used effectively in tuning these controllers.

  • PDF

열처리용 단상 PWM인버터시스템의 히터온도 및 인버터 출력전압 제어기법 (Control Strategies of Both the Heater Temperature and the Inverter Output Voltage of a Single-Phase PWM Inverter Systems for Heat Treatment)

  • 양시경;전태원
    • 전기학회논문지
    • /
    • 제67권8호
    • /
    • pp.1047-1054
    • /
    • 2018
  • This paper proposed the strategies for controlling both the heater temperature and the output voltage of a single-phase inverter for the heat treatment. The single-phase inverter system for the heat treatment controls the heater temperature to its reference one, and also it limits the inverter output voltage to 60 V for safety. The stability may be deteriorated due to the large time constant difference between the heater temperature and inverter output voltage. In order to ensure the stability, a hysteresis on/off control approach for the heater temperature control is adapted, and both the open-loop and the closed-loop control strategies of the output voltage are suggested. The performances for the proposed strategies are demonstrated with the experiments.

사출 금형의 능동형 온도제어에 따른 사출특성에 관한 연구 (A Study on Injection Characteristic using Active Temperature Control of Injection mold)

  • 조창연;신홍규;홍남표;서영호;김병희
    • 한국소성가공학회:학술대회논문집
    • /
    • 한국소성가공학회 2007년도 추계학술대회 논문집
    • /
    • pp.302-305
    • /
    • 2007
  • In recent years, many researches on new storage media with high capacity and information are developing. For manufacture of optical storage with high capacity, the injection molding process is generally used. In order to increase the filling ratio of the injection molding structure, the injection molding process required for high injection pressure, packing pressure and temperature control of the mold. However, conventional injection molding process is difficult to increase the filling ratio using injection master with the range of several nanometers and high aspect ratio. In order to improve and increase filling ratio of nano-structure with high aspect ratio, the active temperature control of injection mold was used. Experimental conditions were used injection pressure, time and temperature. Consequently, by using the peltier device into injection mold, we carried out the efficient and active temperature control of mold at low cost.

  • PDF

온수난방시스템 온실의 온도제어 시뮬레이션 (A Simulation of Temperature Control of Greenhouse with Hot-Water Heating System)

  • 정태상;하종규;민영봉
    • 생물환경조절학회지
    • /
    • 제8권3호
    • /
    • pp.152-163
    • /
    • 1999
  • 온수난방시스템 온실의 디지털 온도제어 수식모형을 수립하고, 이 수식모형을 이용하여 제어시뮬레이션을 실시하여 최적의 온도제어 방법을 구명하였다. 이용된 제어기법은 종래의 온수온도 일정 공급ON-OFF 제어, 비례제어, PI 제어, PID 제어기법이었으며, 시뮬레이션을 이용해 제어기법별 제어성능을 비교 분석하였다. 대상유리온실의 실내온도( T$_{i}$ )에 관한 디지털 제어수식모형은 공급온수온도( T$_{w}$ )와 외기온도( T$_{o}$ )가 관련된 T$_{i}$($textsc{k}$+1)= 0.851.T$_{i}$($textsc{k}$)+0.055.T$_{w}$($textsc{k}$)+0.094.T$_{o}$ ($textsc{k}$)로 나타났다. 온실의 실내온도제어 시뮬레이션을 실시한 결과 종래의 온수온도 일정공급 ON-OFF 제어, P 제어, PI 제어,PID 제어의 정정시간, 오버슛트, 정상오차는 각각 무한, 3.5$0^{\circ}C$, 3.5$0^{\circ}C$ / 30분, 2.37$^{\circ}C$, 0.51$^{\circ}C$ / 21분, 0.0$0^{\circ}C$, 0.23$^{\circ}C$ / 18분, 0.0$0^{\circ}C$, 0.23$^{\circ}C$로 나타났으며, 온수난방시스템 온실의 온도제어에 가장 적합한 제어기법은 PI와 PID제어인 것으로 나타났다 또한 미분이득은 온실의 난방계에 거의 영향을 미치지 않지만 적분이득은 큰 영향을 미치는 것으로 나타났다. 나타났다.

  • PDF

Micro-computer를 이용(利用)한 Greenhouse의 온도제어(溫度制御) System 개발(開發)에 관한 연구(硏究) (A Study on the Development of Greenhouse Temperature Control System by Using Micro-computer)

  • 서원명;민영봉;윤용철
    • Journal of Biosystems Engineering
    • /
    • 제15권2호
    • /
    • pp.134-142
    • /
    • 1990
  • This study was carried out for the development of greenhouse temperature control system by modifying an APPLE-II microcomputer attached with several interface systems. The interface systems are composed of 12 bit A/D converter, output port, multiplexer, time clock, etc. Under the operation of developed system, the greenhouse temperature was to be manipulated within the setting temperatures assumed to be appropriate for certain plant growth. The temperature control equimpents installed in the greenhouse are one-speed propeller type fan and two-phase electric heater, which are selectively started or stopped according to the control logic programmed in the control system. The results are summarized as follows : 1. The difference between two temperatures measured by the developed system and the self-recording thermometer calibrated with standard thermometer was less than $1^{\circ}C$. 2. When the temperature were measurd by 12 bit A/D converter and both electric heater and ventilation fan were controlled by developed ON/OFF logic, greenhouse temperature showed narrow fluctuation bands of less than $1^{\circ}C$ near the setting temperatures. 3. The temperature acquisition and control system developed in this study is expected to be applicable to environment control system such as greenhouse only by modifying the logic based on long term experimental data. 4. In order to reduce the measurement error and to increase the system control efficiency, it is recommended that continuous study should be carried out in the aspect of eliminating various systematic noises and improving the environmental control logic.

  • PDF

캐비티 온도센서를 이용한 최적 사출공정 제어 (Optimal Control of Injection Molding Process by Using temperature Sensor)

  • 박천수;강철민
    • Design & Manufacturing
    • /
    • 제2권5호
    • /
    • pp.30-33
    • /
    • 2008
  • Injection Molding is the most effective process for mass production of plastic parts. The injection molding process is composed with several steps such as Filling, Packing, Holding, Cooling, Ejecting. Among them, filling and packing process should be considered carefully to improve accuracy of dimension, surface quality of plastic parts. Usually the quality above-mentioned is managed with weight of part after molding on the field. In this paper, a series of experiment for molding automotive front bumper was conducted with cavitity temperature sensor to optimize switch-over time(V-P switching), hot runner vale gate sequence time during filling and packing step for the purpose of uniform quality, weight at every molding. As a result, it was found that it is effective method to use temperature sensor in injection molding for quality control of plastic molding.

  • PDF

가열로의 실시간 최적 제어기 설계 (Design of Real Time Optimization Control System on Heating Furnace)

  • 조현섭;오명관
    • 한국산학기술학회:학술대회논문집
    • /
    • 한국산학기술학회 2009년도 추계학술발표논문집
    • /
    • pp.633-635
    • /
    • 2009
  • It is a quite quality concerning to control temperature of single crystalline growth as it does when you get most of heat treating products. It is also important factor to control temperature when you make the $Al_2O_3$(single crystalline) used to artificial jewels, glass of watches, heat resistant transparent glasses. Thus, it is a major interest to get the proper temperature in accordance with the time process while you are making mixture of oxygen and hydrogen to have the right temperature. In this paper, we will study of electrical valve positioning system for the gas mixture to improve the quality of products.

  • PDF

Analysis of Supply Airflow Control by a Stratified Thermal Model in a VAV System

  • Kim, Seo-Young;Moon, Jeong-Woo;Cho, Hyung-Hee
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제9권3호
    • /
    • pp.46-56
    • /
    • 2001
  • The present study concerns the numerical simulation of a supply airflow control in a variable air volume (VAY) system. A stratified thermal model (multi-zone model) is suggested to predict a local thermal response of an air-conditioned space. The effects of various thermal parameters such as the cooling system capacity, the thermal mass of an air-conditioned space, the time delay of thermal effect, and the building envelope heat transmission are investigated. Further, the influence of control parameters such as the supply air temperature, the PI control factor and the thermostat location on a VAV system is quantitatively delineated. The results obtained show that the previous homogeneous lumped thermal model (single zone model) may overestimate the time taken to the set point temperature. It is also found that there exist the appropriate ranges of the control parameters for the optimal airflow control of the VAV system.

  • PDF