• 제목/요약/키워드: time/temperature control

검색결과 2,357건 처리시간 0.031초

Progress of Composite Fabrication Technologies with the Use of Machinery

  • Choi, Byung-Keun;Kim, Yun-Hae;Ha, Jin-Cheol;Lee, Jin-Woo;Park, Jun-Mu;Park, Soo-Jeong;Moon, Kyung-Man;Chung, Won-Jee;Kim, Man-Soo
    • International Journal of Ocean System Engineering
    • /
    • 제2권3호
    • /
    • pp.185-194
    • /
    • 2012
  • A Macroscopic combination of two or more distinct materials is commonly referred to as a "Composite Material", having been designed mechanically and chemically superior in function and characteristic than its individual constituent materials. Composite materials are used not only for aerospace and military, but also heavily used in boat/ship building and general composite industries which we are seeing increasingly more. Regardless of the various applications for composite materials, the industry is still limited and requires better fabrication technology and methodology in order to expand and grow. An example of this is that the majority of fabrication facilities nearby still use an antiquated wet lay-up process where fabrication still requires manual hand labor in a 3D environment impeding productivity of composite product design advancement. As an expert in the advanced composites field, I have developed fabrication skills with the use of machinery based on my past composite experience. In autumn 2011, the Korea government confirmed to fund my project. It is the development of a composite sanding machine. I began development of this semi-robotic prototype beginning in 2009. It has possibilities of replacing or augmenting the exhaustive and difficult jobs performed by human hands, such as sanding, grinding, blasting, and polishing in most often, very awkward conditions, and is also will boost productivity, improve surface quality, cut abrasive costs, eliminate vibration injuries, and protect workers from exposure to dust and airborne contamination. Ease of control and operation of the equipment in or outside of the sanding room is a key benefit to end-users. It will prove to be much more economical than normal robotics and minimize errors that commonly occur in factories. The key components and their technologies are a 360 degree rotational shoulder and a wrist that is controlled under PLC controller and joystick manual mode. Development on both of the key modules is complete and are now operational. The Korean government fund boosted my development and I expect to complete full scale development no later than 3rd quarter 2012. Even with the advantages of composite materials, there is still the need to repair or to maintain composite products with a higher level of technology. I have learned many composite repair skills on composite airframe since many composite fabrication skills including repair, requires training for non aerospace applications. The wind energy market is now requiring much larger blades in order to generate more electrical energy for wind farms. One single blade is commonly 50 meters or longer now. When a wind blade becomes damaged from external forces, on-site repair is required on the columns even under strong wind and freezing temperature conditions. In order to correctly obtain polymerization, the repair must be performed on the damaged area within a very limited time. The use of pre-impregnated glass fabric and heating silicone pad and a hot bonder acting precise heating control are surely required.

저수온기 넙치 치어에 있어서 발효마늘분말의 사료 내 첨가가 면역반응, 혈액성분 및 주요 어병세균에 대한 질병저항성에 미치는 영향 (Effects of Dietary Supplementation of Fermented Garlic Powder on Immune Responses, Blood Components, and Disease Resistance against Principal Fish Disease of Juvenile Olive Flounder, Paralichthys olivaceus in Low Temperature Season)

  • 김성삼;송진우;임세진;정준범;전유진;여인규;이경준
    • Journal of Animal Science and Technology
    • /
    • 제52권4호
    • /
    • pp.337-346
    • /
    • 2010
  • 우리 연구팀은 넙치를 대상으로 사료 내 발효마늘분말(fermented garlic powder, FGP)의 첨가에 의한 비특이적 면역반응과 어병세균(V. anguillarum, S. iniae, E. tarda)에 대한 질병 저항성에 대해 처음으로 보고한다. 동일한 단백질 함량(45%)과 칼로리(17.1 MJ/kg)를 갖은 4개의 실험사료는 발효마늘분말이 0%, 0.5%, 1% 및 2% (G-0, G-0.5, G-1 및 G-2)가 포함되도록 조성되었다. 실험은 3반복구로 수조 당 30마리의 어류를 대상으로 유수식 시스템에서 수행되었다. 5주간의 성장실험 종료 후, 각 수조에서 건강한 어류를 선별하여 어류의 항병력을 평가하기 위해 3가지 박테리아 부유액(1 ml)을 복강에 주사하였다. 5주간의 성장실험기간 동안에 성장률, 일간성장률, 사료전환효율, 단백질전환효율 및 생존율에서는 실험사료에 의한 유의적인 차이가 없었다. 그러나 사료섭취율은 발효마늘분말이 2% 첨가된 그룹에서 대조구와 비교하여 유의적으로 낮았다. 헤모글로빈, 헤마토크릿, 대식세포 활성 및 라이소자임 활성에서는 사료 내 발효마늘분말 함량이 증가함에 따라 유의적으로 증가하였다. 발효마늘분말 0.5% 첨가구의 혈장 중성지질은 대조구보다 유의적으로 낮았다. 누적사망률은 E. tarda의 경우를 제외한 모든 공격실험에서 발효마늘분말이 포함된 사료를 섭취한 어류가 대조구와 비교하여 유의적으로 낮았다. 이번 연구의 결과를 볼 때, 사료 내 발효마늘분말의 첨가는 넙치에 있어서 V. anguillarum과 S. iniae에 대한 항병력 및 비특이적 면역반응을 향상시킨 것으로 사료된다.

Er:YAG 레이저 조사가 Streptococcus mutans의 증식억제에 미치는 효과 (INHIBITORY EFFECT OF Er:YAG LASER ON THE GROWTH OF STREPTOCOCCUS MUTANS)

  • 송광철;이창섭;이상호;이난영
    • 대한소아치과학회지
    • /
    • 제30권1호
    • /
    • pp.15-24
    • /
    • 2003
  • Er:YAG 레이저의 구강내 산 생성 세균인 S. mutans에 대한 살균효과를 평가하기 위하여 S. mutans KCTC 3065가 포함된 세균배양액에 $650{\mu}m$ 직경의 조사 beam을 갖는 Er:YAG 레이저를 비접촉식 방법으로, 조사세기(50mJ, 100mJ, 150mJ)와 pulse repetition rate(5Hz, 10Hz, 20hz) 그리고 조사시간(1초, 3초, 5초)을 달리하여 조사하고 이때의 세균 배양액의 온도변화, 세균 군락수, 산 생성능, 불용성 세포외다당류의 양을 측정한 결과 다음과 같은 결과를 얻었다. $10{\mu}l$ 세균 배양액에서는 레이저를 조사한 군이 레이저를 조사하지 않은 대조군에 비해 전반적으로 세균의 군락수가 감소되었으며 조사세기와 pulse repetition rate가 클수록, 그리고 조사시간이 길어질수록 세균 군락수가 비례하여 감소하는 경향을 보였다. 그러나 $100{\mu}l$ 세균 배양액에서는 레이저를 조사하지 않은 대조군에 비해 세균 군락수의 변화가 적었다. $10{\mu}l$ 세균 배양액에서는 레이저 조사에 의해 S. mutans의 산 생성능이 일정시간 동안 억제되었으나 $100{\mu}l$ 세균 배양액에서는 레이저를 조사하지 않은 대조군에 비해 산 생성능의 변화가 관찰되지 않았다. $10{\mu}l$ 세균 배양액에서는 레이저 조사에 의해 S. mutans의 불용성 세포외다당류의 합성이 부분적으로 감소되었으나 $100{\mu}l$ 세균 배양액에서는 변화가 관찰되지 않았다. 이와 같은 사실에 근거해 볼 때 레이저는 S. mutans에 대한 증식억제효과를 가지고 있으며 그 기전은 초음파 등에 의한 기계적 작용이 아닌 열작용에 의한 것임을 추정해 볼 수 있다.ation angle check 등 기존의 기계적 점검을 디지털 영상을 이용하여 실행할 수 있었다. 결 론: 기존의 Flat 또는 정육면체 형태의 기계적 점검 장치로는 쉽게 하기 힘든 non-coplanar field에 적용되는 Gantry와 Couch가 동시에 rotation 되었을 때 그 isocenter의 일치도를 실시간으로 확인할 수 있었다.^{(R)}$를 도포한 후 중합한 군이 산소억제층의 두께가 평균 49%의 감소되었으며(p<0.05), 이들 산소를 차단한 군 간의 유의차는 없었다.며 CYP1A2유전자형에 따른 영향은 관찰할 수 없었다. CYP1A2유전자형에 따른 생체내 대사능을 관찰하는 실험이 향후 이루어 져야 할 것으로 사료된다.san film보다 큰 수증기 투과도를 보였다.적으로 유의한 차이를 보이지 않았다.y tissue layer thinning은 3 군모두에서 관찰되었고 항암 3 일군이 가장 심하게 나타났다. 이상의 실험결과를 보면 술전 항암제투여가 초기에 시행한 경우에는 조직의 치유에 초기 5 일정도까지는 영향을 미치나 7 일이 지나면 정상범주로 회복함을 알수 있었고 실험결과 항암제 투여후 3 일째 피판 형성한 군에서 피판치유가 늦어진 것으로 관찰되어 인체에서 항암 투여후 수술시기는 인체면역계가 회복하는 시기를 3주이상 경과후 적어도 4주째 수술시기를 정하는 것이 유리하리라 생각되었다.한 복합레진은 개발의 초기단계이며, 물성의 증가를 위한 연구가 필요할 것으로 사료된다.또 다른 약물인 glycyrrhetinic acid($100{\mu}M$)도 CCh 자극으로 인한 타액분비를 억제하였다. 이상의 결과로 미루어 gap junction은 흰쥐 악하선 세포로부터의 타액분비 조절에 중요한 역할을 하는데, 이는 gap junction이 세포막 $Ca^{2+}$ 통로를 조절함으로써 수용체 자극으로 유발된

  • PDF

조미료(調味料)가 ${\alpha}-amylase$활성(活性)에 미치는 영향(影響) (Effects of Condiments upon ${\alpha}-Amylase$ activity)

  • 서명자
    • Journal of Nutrition and Health
    • /
    • 제9권1호
    • /
    • pp.104-109
    • /
    • 1976
  • 0.2% ${\alpha}-amylase$용액(溶液)에 파, 생강, 마늘, 고추, 후추 mono sodium glutamate. 설탕, 고초냉이, 겨자, 산초등(等) 각종(各種) 조미료(調味料)를 Homogenizer로 마쇄(摩碎) 하여 0.2% ${\alpha}-amylase$용액에 0%, 1%, 5%, 10%씩 첨가(添加)한다음 일정시간(一定時間)마다 Wohlgemuth 법(法)에 의(依)하여 ${\alpha}-amylase$의 활성(活性)을 측정(測定)하여 조미료(調味料)가 ${\alpha}-amylase$의 활성(活性)에 미치는 영향(影響)을 실험(實驗)하여 다음과 같은 결과(結果)를 얻었다. 1)파 0.2% ${\alpha}-amylase$ 용액(溶液)에 파를 1%, 5%, 10% 첨가(添加) 하였을때의 ${\alpha}-amylase$ 활성(活性)은 대조구(對照區)에 비(比)하여 계속 50% 억제 되었다. 2)마 늘 마늘 1%, 5%, 10% 첨가구(添加區)는 대조구(對照區)에 비(比)하여 약(約) 50% 억제 되었다. 3)생 강 생강 첨가구(添加區)는 대조구(對照區)에 비(比)하여 전반적(全般的)으로 7일(日)까지는 50% 억제되었으나 5%, 10% 첨가구(添加區)는 10일(日)에 와서 더욱 억제 되였다. 4)후 추 후추 첨가구(添加區)는 모두 저장(貯臧) 3일(日)까지는 대조구(對照區)에 비(比)하여 50% 억제되었으나 3일(日) 이후(以後)부터는 약(約) 75%의 억제 현상을 나타냈다. 5)고 추 1% 첨가구(添加區)는 대조구(對調區)에 비(比)하여 50% 억제 하였으며 5%, 10% 첨가구(添加區)는 시일경과(時日經過)함에 따라 75%까지 억제하였다. 6)산 초 산초 1%, 5% 첨가구(添加區)는 저장시일(貯臧時日)과 관계(關係)없이 50% 억제하였고 10% 첨가구(添加區)는 3일이후(日以後)부터 계속 억제하여 75%까지 억제 하였다. 7)겨 자 겨자 1%, 5% 첨가구(添加區) 대조구(對照區)에 비(比)하여 ${\alpha}-amylase$ 활성(活性)을 50% 억제 하였으나 10% 첨가구(添加區)는 시일경과(時日經過)에 따라 62.5%의 억제 현상을 보였다. 8) 고초냉이 고초냉이 1%, 5% 첨가구(添加區)는 ${\alpha}-amylase$ 활성(活性)을 50% 억제 하였으나 10% 첨가구(添加區)는 87.5%까지 억제하였다. 9) Mono sodium glutamate Mono sodium glutamate 1% 첨가구(添加區)는 5일(日)까지는 ${\alpha}-amylase$ 활성(活性)을 억제하지 않았으나 그후(後)부터 50% 억제하였고 5%, 10%, 첨가구(添加區)는 시일(時日)이 경과(經過)함에따라 50%에서 82.5%로 억제되었다. 10)설 탕 설탕 1%, 5% 첨가구(添加區)는 저장(貯臧) 3일(日)까지는 50%로, 그 이후(以後)는 75% 억제되었고 설탕 10% 첨가구(添加區)는 계속 75% 억제 하였다.

  • PDF

북방전복, Haliotis discus hannai 에 대한 Bacillus amyloliquefaciens의 probiotic 효과 (Potential use of Bacillus amyloliquefaciens as a probiotic bacterium in abalone culture)

  • 박진영;김위식;김흥윤;김은희
    • 한국어병학회지
    • /
    • 제29권1호
    • /
    • pp.35-43
    • /
    • 2016
  • 전복의 면역, 생리 및 생태에 관한 기초 연구는 매우 부족하며 전복 질병에 관한 연구 또한 어류에 비하여 극히 취약한 상태이다. 외국의 경우 전복 치패에서 vibrios로 인한 피해 사례가 많이 보고되어 있으나 우리나라에서는 세균성 질병으로 인한 전복 폐사에 관한 보고가 드물다. 그러나 폐사체로부터 vibrios가 높은 빈도로 분리되고 있어 이들 Vibrio속 세균과 전복 폐사와의 관련성에 대한 검토가 필요하다. 현재 전복 양식 현장에서는 질병으로 인한 피해를 최소화하기 위해 항균제를 사용하고 있지만 치료 효과는 미미한 수준이다. 이에 대한 대책으로 probiotics에 대한 요구가 증가하고 있어 본 연구에서는 인체에 위해하지 않은 균을 분리하여 전복 probiotics로서의 개발 가능성을 알아보았다. 잘 숙성된 김치액에서 분리된 균들 중 다양한 vibrios에 대하여 항균력을 나타낸 KC16-2을 candidate probiotic 균으로 선발하였다. KC16-2는 생화학적 특성과 16S rRNA gene sequence에 근거하여 Bacillus amyloliquefaciens로 동정되었다 (B. amyloliquefaciens KC16-2). B. amyloliquefaciens KC16-2는 in vitro 실험에서 병원성 비브리오에 대하여 광범위한 생장 억제 효과를 보였으며, 온도 $15{\sim}25^{\circ}C$의 해수에서 4일까지 일정수를 유지하였으므로 겨울 이외의 기간에는 사용이 가능하다고 판단되었다. 또한 담즙에 의해 생장이 억제되었으나 시간 경과에 따라 처음 투여 농도보다 증가하는 양상이 관찰되어 담즙이 있는 곳에서도 생존 가능하다고 판단되었다. 시판 사료에 KC16-2를 혼합하여 12주간 전복에 투여하였을 때 대조구에 비해 다소 좋은 성장을 보였으나 통계학적으로 유의한 차이는 없었다. 한편 전복에 병원성을 가진 Vibrio tubiashii의 인위감염실험에서 probiotic사료를 공급한 수조에서 폐사율을 약 50% 감소시키는 결과를 나타냄으로써 기회성 vibrios로 인한 전복의 폐사를 줄이기 위하여 KC16-2의 사용이 긍정적으로 검토될 수 있음을 시사하였다.

갈색날개매미충 알 기생봉인 날개매미충알벌(Phanuromyia ricaniae)의 생물 특성 (Biological characteristics of Phanuromyia ricaniae(Hemiptera: Platygastroidea), an egg parasitoid of Ricania sublimata (Hemiptera: Ricaniidae))

  • 전성욱;김광호;이관석;서보윤;김지은;강위수;조점래
    • 환경생물
    • /
    • 제38권4호
    • /
    • pp.586-593
    • /
    • 2020
  • 본 연구는 갈색날개매미충을 생물적 방제인자로 활용하기 위해 알 기생 천적인 날개매미충알벌의 발육 특성을 조사하였다. 날개매미충알벌의 온도별 발육기간은 25℃에서 알은 3.8일, 유충 11.1일 및 번데기 16.3일, 30℃에서는 알 3.4일, 유충 7.8일 및 번데기 15.3일이었다. 유충 기간을 제외하고 온도에 따라 유의미한 발육 기간의 차이를 보이지 않았다. 다만 알~번데기까지 전 발육기간은 25℃에 비해 30℃에서 발육기간이 짧아 온도에 따라 유의미한 차이를 보였다. 하루 중 날개매미충알벌의 우화는 불이 켜져 있는 명 기간에 모든 개체가 성충으로 우화하였다. 우화율이 가장 높은 시간대는 10:00~12:00 사이였고(34.5%), 그 다음으로 12:00~14:00 사이였다(22.99%). 암 기간(00:00~08:00)에서는 성충으로 우화하는 개체는 관찰되지 않았다. 날개매미충알벌 성충의 성비는 암컷이 75.8%, 수컷이 24.2%로 암수 비율은 약 3 : 1이었다. 성충의 수명은 20℃에서 암컷과 수컷이 각각 49.0일, 44.0일, 25℃에서 27.6일, 28.4일 및 30℃에서 18.0일, 14.0일로 조사한 온도 중 암수 모두 온도가 낮은 20℃에서 수명이 길었고, 온도가 높을수록 수명은 짧아지는 경향을 보였다. 암컷 성충은 00:00~02:00 사이를 제외하고 모든 시간대에 걸쳐 산란하였고, 산란수가 가장 많은 시간대는 20:00~22:00 사이로 26.1%를 차지하였고, 그 다음으로는 10:00~12:00 사이에 15.7%로 조사되었다. 날개매미충알벌은 수컷을 생산하는 단위생식을 하는 것으로 조사되었다. 따라서 이상의 결과로 날개매미충알벌은 갈색날개매미충을 방제하는 중요한 생물적 방제 인자로 활용할 수 있을 것으로 생각된다.

Sensory Information Processing

  • Yoshimoto, Chiyoshi
    • 대한의용생체공학회:의공학회지
    • /
    • 제6권2호
    • /
    • pp.1-8
    • /
    • 1985
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70$\pm$1.32mmHg/min)compared to CF dialyzers(4.32$\pm$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500, 550, 570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500, 550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100, 300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3, 000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.SpO2 with Plethysmograph.

  • PDF

High Resolution HC$_3$N Observations toward the Central Region of Sagittarius B2

  • H.S-Ching;Oh, M.ishi;M.Morimoto
    • 한국우주과학회:학술대회논문집(한국우주과학회보)
    • /
    • 한국우주과학회 1993년도 한국우주과학회보 제2권2호
    • /
    • pp.17-17
    • /
    • 1993
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70${\pm}$1.32mmHg/min)compared to CF dialyzers(4.32${\pm}$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500,550,570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500,550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100,300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3,000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.

  • PDF

무인헬기용 Macrogranule(GG) 제초제의 안정성 및 살포방법 연구 (Studies on Application Method and Safety of Macrogranule(GG) Herbicide for Remote-controlled Aerial Application)

  • 윤철수;배창휴;이성춘;김경현;이계환;조태경;황인천
    • 한국잡초학회지
    • /
    • 제31권3호
    • /
    • pp.294-307
    • /
    • 2011
  • 무인헬기 살포로 논에 발생하는 잡초를 방제할 목적으로 macrogranule(GG) 제초제를 개발하였다. 약제 제조와 제조약제의 안정성, 살포방법에 따른 적용방법을 조사하였고, 제형별 살포소요시간 경제성을 분석한 결과를 요약하면 다음과 같다. 제조 GG의 입경(粒經)은 2.5~3mm 범위내에 85%이상을 차지하였고, 가비중은 $0.2\sim0.4g\;mL^{-1}$로 수면에서 부유성을 갖고 확산되는 입제고형물이었다. GG의 저장안정성은 $54{\pm}2^{\circ}C$ 항온기에서 2, 4, 6, 8주간 저장 후 halosulfuron-methyl을 HPLC로, mefenacet는 GC로 분석한 결과 유효성분 및 외형 변화가 없이 안정되어 있었다. GG의 수중붕괴성은 온도가 상승할수록 증가하였다. 또 담수 중 pH별 수중붕괴성은 담수 pH의 영향은 없었다. GG의 살포거리는 손살포, 도구살포 및 기계살포 등에서 각각 4~5m, 7m, 10~12m로 살포방법에 따라 달랐다. GG의 약효 및 작물안전성은 손살포, 도구살포, 기계살포 및 무인헬기살포에서 모두 우수하였다. 제형간 $4,000m^2$ 기준 손살포 소요시간은 GG, GR, SC, TB가 각각 38분 4초, 42분 20초, 38분 10초, 21분 4초였으나, 무인헬기 살포시 1분 32초를 나타냈다. 제형의 형태 및 특성상 무인헬기살포가 가능한 제형은 SC, GG였다.

기후변화에 따른 동해 심층 해수의 물리적 특성 및 순환 변화 연구 : 현황과 전망 (Studies on Changes in the Hydrography and Circulation of the Deep East Sea (Japan Sea) in a Changing Climate: Status and Prospectus)

  • 이호준;남성현
    • 한국해양학회지:바다
    • /
    • 제28권1호
    • /
    • pp.1-18
    • /
    • 2023
  • 동해는 전 세계적으로 가장 빠른 수준의 온난화를 경험하는 해역 중 하나로서, 기후변화에 민감하게 반응할 뿐 아니라 대양에 비해 월등히 짧은 순환 주기를 가지고 있기 때문에 미래의 대양 환경 변화에도 중요한 시사점을 주는 것으로 알려져 있다. 그러나 동해 심층 해수의 특성과 순환의 변화 과정에 대한 연구는 동해 전역의 심층을 정밀하게 조사하기 위한 국제협력 프로그램이 자리잡고, 측정 장비의 분해능을 포함하는 관측기술과 수치모델 모의 능력이 크게 향상된 최근(1990년대 이후)에서야 본격화되고 있다. 여기서는 동해 심층 해수의 물리적 특성과 순환의 변화 과정에 대한 그간의 연구 결과를 요약하고, 향후 남은 과제를 제시하고자 한다. 동해는 내부에서 자체적으로 심층 해수가 생성되며 대양과 분리된 독특한 심층 순환 구조를 가진다. 동해의 수백 m 수심 아래에는 수온이 낮고(<1℃) 염분이 거의 일정(34.0-34.1)한 해수가 분포하기 때문에 오랜 기간 이 해수를 일본해고유수(동해고유수)로 명명된 단일 해수로 여겨 왔다. 그러나 1990년대 이후 정밀한 관측이 이루어지며, 동해 심층을 채우고 있는 해수가 적어도 3개의 서로 다른 물리적 특성을 가진 해수(중앙수, 심층수, 저층수)로 구성됨이 밝혀졌다. 이들 3개 해수의 물리적 특성과 해수 사이의 경계 수심은 항상 일정한 것이 아니라, 지난 수십 년 동안 유의한 수준의 변화를 겪어왔다. 동해 북부 해역의 대마난류 재순환, 해양-대기 열과 담수의 교환량, 해빙 형성에 영향을 받는 대류(심층사면대류 및 심층외양대류) 과정에 따라 심층 해수 생성에 뚜렷한 차이가 발생했기 때문이다. 생성된 심층 해수는 수심이 얕은 곳을 오른쪽에 두고 일본 분지에서부터 반시계 방향으로 울릉 분지, 야마토 분지를 차례로 거쳐 다시 일본 분지로 수송되며, 이 수평적인 심층 순환도 변화를 겪어 왔다. 수평적인 심층 순환은 동시에 남북 및 연직 방향의 순환(자오면 순환) 경로와 강도의 변화를 동반한다. 동해는 수천 년 규모의 순환 주기를 가지는 대양에 비해 훨씬 짧은 수백 년 혹은 그 이내의 순환 시간 규모를 가지기 때문에 동해 심층 해수의 물리적 특성과 자오면 순환의 급격한 변화를 더 뚜렷하게 볼 수 있을 것으로 기대 가능하다. 심층 및 자오면 순환 사이의 연계성, 대양과 동해의 유출입 해수 수송을 포함하는 동해 상층 순환과 심층 순환 사이의 연계성은 아직까지 잘 밝혀지지 않았다. 동해 심층 해수 수송의 경로와 강도를 지배하는 다양한 과정들에 대한 후속 연구들이 요구된다.