• Title/Summary/Keyword: tibiae

Search Result 58, Processing Time 0.021 seconds

Bone repair in defects filled with AH Plus sealer and different concentrations of MTA: a study in rat tibiae

  • Jessica Emanuella Rocha Paz;Priscila Oliveira Costa;Albert Alexandre Costa Souza;Ingrid Macedo de Oliveira;Lucas Fernandes Falcao;Carlos Alberto Monteiro Falcao;Maria Angela Area Leao Ferraz;Lucielma Salmito Soares Pinto
    • Restorative Dentistry and Endodontics
    • /
    • v.46 no.4
    • /
    • pp.48.1-48.10
    • /
    • 2021
  • Objectives: This study aimed to evaluate the effects on bone repair of different concentrations of mineral trioxide aggregate (MTA) added to AH Plus. Materials and Methods: Bone tissue reactions were evaluated in 30 rats (Rattus norvegicus) after 7 and 30 days. In the AH + MTA10, AH + MTA20, and AH + MTA30 groups, defects in the tibiae were filled with AH Plus with MTA in proportions of 10%, 20% and 30%, respectively; in the MTA-FILL group, MTA Fillapex was used; and in the control group, no sealer was used. The samples were histologically analyzed to assess bone union and maturation. The Kruskal-Wallis and Mann-Whitney tests were performed for multiple pairwise comparisons (p ≤ 0.05). Results: At the 7-day time point, AH + MTA10 was superior to MTA-FILL with respect to bone union, and AH + MTA20 was superior to MTA-FILL with respect to bone maturity (p < 0.05). At the 30-day time point, both the AH + MTA10 and AH + MTA20 experimental sealers were superior not only to MTA-FILL, but also to AH + MTA30 with respect to both parameters (p < 0.05). The results of the AH + MTA10 and AH + MTA20 groups were superior to those of the control group for both parameters and experimental time points (p < 0.05). Conclusions: The results suggest the potential benefit of using a combination of these materials in situations requiring bone repair.

Histomorphometric Analysis of Two Types of Coated Implants : a Preliminary Study Using the Rabbit Tibia Model

  • Yeo, In-Sung;Lee, Hyo-Jung
    • Journal of Korean Dental Science
    • /
    • v.2 no.1
    • /
    • pp.28-30
    • /
    • 2009
  • Purpose : The purpose of this pilot experiment was to evaluate early bone response in two types of coated implants using the rabbit tibia model. Materials and Methods : Screw type titanium implants manufactured with a calcium metaphosphate (CMP) coating and hydroxyapatite (HA) coating were placed in the tibiae of 3 New Zealand White rabbits. The bone responses at 2 weeks after insertion were evaluated and compared by histomorphometry. Results : There was no significant difference in bone-to-implant contact between the groups (P>.05). However, some qualitative differences on histologic views were found. Conclusions : CMP-coating is suggested to be the preferred candidate for fast osseointegration over HAcoating.

  • PDF

Scaptognathus magnus (Acari: Halacaridae), a New Record from Korea

  • Lee, Jimin;Shin, Jong Hak;Chang, Cheon Young
    • Animal Systematics, Evolution and Diversity
    • /
    • v.36 no.2
    • /
    • pp.175-181
    • /
    • 2020
  • An arenicolous halacarid, Scaptognathus magnus Abé is first recorded from Korea, which was collected from littoral coarse sandy bottom around Simnibawi Rock off Gangreung in the east coast of South Korea. The remarkable characteristics of this species are large body with idiosoma more than 470 ㎛ long, nearly trapezoidal anterior dorsal plate, and a unique chaetotaxy of bipectinate setae 5-3-3-3 on tibiae I-IV. The characteristics of Korean specimens coincide well with the original description from Hokkaido, Japan, except for the number of parambulacral setae on tarsus III and the weak median claws. Detailed illustrations and scanning electron microscope photographs based on Korean specimens are provided.

Scaptognathus teuriensis, a New Record of Halacarid Mite (Acari, Halacaridae) from Dokdo Island of Korea

  • Lee, Jimin;Chang, Cheon Young
    • Animal Systematics, Evolution and Diversity
    • /
    • v.33 no.1
    • /
    • pp.45-50
    • /
    • 2017
  • A halacarid species of Scaptognathus teuriensis $Ab{\acute{e}}$ is recorded from Korea on the basis of the specimens collected from littoral sandy sediments at Dokdo Island, the easternmost island off Uleung Island of South Korea. Korean specimens coincide well with the key characters in the original description for types from Hokkaido, Japan, such as male genitoanal plate comprising only pars sclerosum, bipartite female genitoanal plate with six perigenital setae, rounded posterior margin of anterior dorsal plate, second and fifth dorsal setae both positioned at membranous cuticle, leg chaetotaxy of bipectinate setae on tibiae I-IV of 4-2-2-2, and tarsi of all legs armed with paired large lateral claws with accessary teeth and small median claw. Redescription based on Korean specimens and scanning electron microscope photomicrographs are provided herein. This is the first record of the genus from Korea.

Riffle beetle genus Leptelmis (Coleoptera Elmidae) in Korea with descriptions of two new species

  • Jung, Sang-Woo;Bae, Yeon-Jae
    • Animal cells and systems
    • /
    • v.16 no.3
    • /
    • pp.254-259
    • /
    • 2012
  • The riffle beetle genus Leptelmis is newly recorded in the Korean fauna with descriptions of two new species, L. coreana, n. sp. and L. ochra, n. sp. Dorsal habitus and line-drawings of diagnostic characters are provided. The adults of L. coreana and L. ochra are similar to those of L. gracilis Sharp or L. parallela Nomura in general appearance, but can be distinguished by the absence of apical spurs on the middle and hind tibiae, light brown body color, smaller body size, and the shape of aedeagus apex. Leptelmis coreana can be distinguished from L. ochra by the absence of hindwings, lack of prominent humeri and wider elytra in posterior portion. Adults of both species occur in lowland streams and large rivers, but L. ochra were encountered relatively infrequently.

Lobohalacarus weberi (Acari, Halacaridae) from Shallow Ground Waters in South Korea

  • Shin, Jong Hak;Lee, Jimin;Chang, Cheon Young
    • Animal Systematics, Evolution and Diversity
    • /
    • v.37 no.3
    • /
    • pp.242-248
    • /
    • 2021
  • Lobohalacarus weberi (Romijn and Viets, 1924) is added to the halacarid fauna of Korea as the third member of freshwater halacarid species. Both the genus and species are newly recorded from Korea. Halacarid mites were collected from two hillside wells and a streamside hyporheic zone in the southeastern region of South Korea. Lobohalacarus weberi is characterized by a well-developed frontal spine-like process, seven dorsal setae, the fourth segment of palp with a short distal and three long proximal setae, and tibiae of legs II to IV with two, one, two pectinate setae, respectively. A few minor individual variabilities were observed in the number of perigenital seta and genital acetabula, the setal armature on genua of legs, and the shape of spinule row on lateral claws.

An Unrecorded Species of the Genus Isobactrus (Acari, Halacaridae) Inhabiting Marine Plastic Debris from Jeju Island, Korea

  • Jimin Lee;Jong Hak Shin;Cheon Young Chang
    • Animal Systematics, Evolution and Diversity
    • /
    • v.39 no.4
    • /
    • pp.289-294
    • /
    • 2023
  • We discovered a halacarid mite species, Isobactrus tuberculatus Abé, 1996, inhabiting marine plastic debris on the coast of Jeju Island, Korea. The key characteristics of these Korean specimens were consistent with those in the original description of specimens from Hokkaido, Japan, including the presence of tuberculate membranous cuticles between the anterior and posterior dorsal plates, fusion of the posterior epimeral plates I and II, tibia II with a bipectinate seta, tibiae III and IV each with five setae, and a pair of subgenital setae in females. However, two small morphological differences were noted: the distance between the anterior and posterior dorsal plates was shorter than that in Japanese specimens, and the location of dorsal seta-2 was closer to the anterior dorsal plate in Korean specimens. We herein provide detailed illustrations of I. tuberculatus, based on the Korean specimens, with a brief taxonomic comment on the similarities among allied congeneric species. The genus Isobactrus is first reported in Korea.

Osseointegration of the titanium implant coated with rhTGF-${\beta}2$/PLGA particles by electrospray: a preliminary microCT analyzing rabbit study (rhTGF-${\beta}2$/PLGA 복합체를 electrospray법으로 코팅한 타이타늄 임플란트 골 유착의 microCT 계측: a preliminary rabbit study)

  • Lee, Woo-Sung;Kim, Seong-Kyun;Heo, Seong-Joo;Koak, Jai-Young;Lee, Joo-Hee;Park, Ji-Man;Park, Yoon-Kyung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.52 no.4
    • /
    • pp.298-304
    • /
    • 2014
  • Purpose: This preliminary rabbit study was conducted to evaluate the effect of recombinant human transforming growth factor-${\beta}2$ (rhTGF-${\beta}2$)/poly lactic-co-glycolic acid (PLGA) coating on osseointegration of the titanium (Ti) implant. Materials and methods: Eight Ti implants were anodized with 300 voltages for three minutes. Four of those were coated with rhTGF-${\beta}2$/PLGA by an electrospray method as the experimental group. The implants were placed into tibiae of four New Zealand rabbits, two implants per a tibia, one implant per each group. After 3 and 6 weeks, every two rabbits were sacrificed and micro-computed tomography (microCT) was taken for histomorphometric analysis. Results: In scanning electron microscope (SEM) image, the surface of rhTGF-${\beta}2$/PLGA coated Ti implant showed well distributed particles. Although statistically insignificant, microCT analysis showed that experimental group has higher bone volume / total volume (BV/TV) and trabecular thickness (Tb.Th) values relatively. Cross sectional view also showed more newly formed bone in the experimental group. Conclusion: In the limitation of this study, rhTGF-${\beta}2$/PLGA particles coating on the Ti implant show the possibility of more favorable quantity of newly formed bone after implant installation.

REMOVAL TORQUE AND BONE FORMATION OF ORTHODONTIC MINISCREW IMPLANT (교정용 미니스크류 임플랜트의 제거회전력 및 골형성에 관한 연굴)

  • Yun, Young-Kuk;Ryu, Jae-Jun;Suh, Kyu-Won
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.45 no.4
    • /
    • pp.492-505
    • /
    • 2007
  • Statement of problem: An orthodontic miniscrew implant has been used as a skeletal anchorage for orthodontic treatment. However, any relation among the influence of the cortical bone, morphologic differences of orthodontic miniscrew implants and new bone formation hasn't been made clear yet. Purpose: The purpose of this study was to evaluate whether the orthodontic miniscrew implant could work as an intraoral skeletal anchorage immediately and stably for orthodontic treatment after insertion of it. Material and methods: Two types of orthodontic miniscrew implants were used in this experiment; tapered type and straight type. One hundred and sixty eight orthodontic miniscrew implants were inserted into the tibiae of 21 rabbits and sacrificed on 3, 7, 11, 14, 21 and 28days later after insertion of them to study removal torque values and histologic and histomorphometric analyses. Results: The results were as follows. 1. The removal torque values of the tapered type were higher than those of the straight type in all groups(p<0.05). 2. There wasn't any distinguishing differences between the tapered type and the straight type about the new bone formation percentage. 3. The removal torque values for both the tapered type and the straight type were gradually decreased at early stages of the test but started to increase at the 7 days group of the straight type and the 11 days group of the tapered type. 4. New bone formation percentage was increased gradually for both the tapered and the straight types as time passed(p<0.05). 5. It was found that the tapered type showed lower values in the cortical bone about both the maximum equilibratory stress distribution and the maximum principal stress distribution than the straight type in linear finite elements analysis. Conclusion: According to the research, the removal torque values were decreased at 7 days group of the tapered type and 11 days group of the straight type after the insertion of the orthodontic miniscrew implants in tibiae of rabbits. Considering the human bone activity, it is better to apply the orthodontic force $3{\sim}4$ weeks later than to apply it immediately after the insertion of orthodontic miniscrew implants. Considering that general orthodontic force is about $250{\sim}500$ grams, the tapered type can be worked as a stable skeletal anchor age in an orthodontic treatment even if the orthodontic force is applied on it immediately after the insertion of it.

THE EXPERIMENTAL STUDY ON BONE HEALING AROUND TITANIUM IMPLANTS PLACED IN IRRADIATED RAT'S TIBIAE (방사선 조사 백서 경골에 티타늄 임플랜트 매식후 골 치유에 관한 연구)

  • Kwak, Byung-Hak;Kim, Jong-Ryoul;Park, Bong-Soo;Shin, Sang-Hoon;Sung, Iel-Yong
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.29 no.6
    • /
    • pp.379-391
    • /
    • 2003
  • The present study was undertaken to evaluate bone regenerative capacity around titanium screw implants placed in irradiated rat's tibiae. At one week after single 15-Gy dose irradiation, miniaturized titanium screw implants were inserted into anterior aspect of the upper tibia of rats weighing 200-250g. Seventy rats were involved: 35 rats were control and 35 rats radiation group. The rats were killed at different intervals as 1, 2, 3, 4, 6, 8, 12 weeks after implantation for histologic observation, histomorphometric analysis and immunohistochemical study with fibronectin and CD34 antibody. 1. Histologically, various stages of bone maturation and ossification can be seen at 4 weeks and regenerated bone close to edges demonstrates more advanced calcification, and network of new bone are well formed at 12 weeks in non-irradiated group. In contrast, active bone formation with increased contact of newly formed bone to implant surface was noted at 4 weeks and a significant amount of new bone formation and bone-implant contact is oberved at 12 weeks in irradiated group. 2. Histomorphometrical analysis confirmed these histologic findings. A significant difference in implant-bone contact and bone density was measured between the control and radiation group. Mean MBD was 62.2% in control group and 27.5% in radiation group, mean MBIC was 86.6% in control group and 47.7% in radiation group, and mean TBIC was 87.3% in control group and 45.6% in radiation group at 12 weeks after implantation. 3. In immunohistochemical study with fibronectin and CD34, radiation reduced hematopoietic progenitor cells severely and disturbed differentiation of osteoblast in bone marrow. The results of this study revealed bone healing capacity around implant after radiation therapy was severely impaired and irradiation reduces the capacity for osseointegration of titanium implants. Many factors including radiation dose, period between radiation and implantation, bone quality, time elapse between first and second surgery, type of prosthetics and hyperbaric oxygen therapy must be considered carefully in postradiation implantation.