• Title/Summary/Keyword: thyroid dose

Search Result 304, Processing Time 0.025 seconds

A Study on Radiation Dose and Image Quality according to CT Table Height in Brain CT (두부 CT 검사 시 테이블 높이에 따른 선량과 화질에 관한 연구)

  • Ki-Won Kim;Joo-Young Oh;Jung-Whan Min;Sang-Sun Lee;Young-Bong Lee;Kyung-Hwan Lim;Yun Yi
    • Journal of radiological science and technology
    • /
    • v.46 no.2
    • /
    • pp.99-106
    • /
    • 2023
  • The height of the table should be considered important during computed tomography (CT) examination, but according to previous studies, not all radiology technologists set the table at the patient's center at the examination, which affects the exposure dose and image quality received by the patient. Therefore, this study intends to study the image quality exposure dose according to the height of the table to realize the optimal image quality and dose during the brain CT scan. The head phantom images were acquired using Philips Brilliance iCT 256. When the image was acquired, the table height was adjusted to 815, 865, 915, 965, 1015, and 1030 mm, respectively, and each scan was performed 3 times for each height. For the exposure dose measurement, optically stimulated luminescence dosimeter (OSLD) was attached to the front, side, eye, and thyroid gland of the head phantom. In the signal to noise ratio (SNR) measurement result, The SNR values for each table height were all lower than 915 mm. As a result of exposure dose, the exposure dose on each area increased as the table height decreased. The height of the table has a close relationship with the patient's radiation exposure dose in the CT scan.

The Evaluation and Development of Head and Neck Radiation Protective Device for Chest Radiography in 10 Years Children (소아(10세) 흉부 방사선촬영에서의 두경부 방사선 방어기구 개발 및 평가)

  • Lee, Jun Ho;Lim, Hyun Soo;Lee, Seung Yeol
    • Journal of Radiation Protection and Research
    • /
    • v.40 no.2
    • /
    • pp.118-123
    • /
    • 2015
  • The frequency of diagnostic radiation examinations in medical institutions has recently increased to 220 million cases in 2011, and the annual exposure dose per capita was 1.4 mSv, 51% and 35% respectively, compared to those in 2007. The number of chest radiography was found to be 27.59% of them, the highest frequency of normal radiography. In this study, we developed a shielding device to minimize radiation exposure by shielding areas of the body which are unnecessary for image interpretation, during the chest radiography. And in order to verify its usefulness, we also measured the difference in entrance surface dose (ESD) and the absorbed dose, before and after using the device, by using an international standard pediatric (10 years) phantom and a glass dosimeter. In addition, we calculated the effective dose by using a Monte Carlo simulation-based program (PCXMC 2.0.1) and evaluated the reduction ratio indirectly by comparing lifetime attributable risk of cancer incidence (LAR). When using the protective device, the ESD decreased by 86.36% on average, nasal cavity $0.55{\mu}Sv$ (74.06%), thyroid $1.43{\mu}Sv$ (95.15%), oesophagus $6.35{\mu}Sv$ (78.42%) respectively, and the depth dose decreased by 72.30% on average, the cervical spine(upper spine) $1.23{\mu}Sv$ (89.73%), salivary gland $0.5{\mu}Sv$ (92.31%), oesophagus $3.85{\mu}Sv$ (59.39%), thyroid $2.02{\mu}Sv$ (73.53%), thoracic vertebrae(middle spine) $5.68{\mu}Sv$ (54.01%) respectively, so that we could verify the usefulness of the shielding mechanism. In addition, the effective dose decreased by 11.76% from $8.33{\mu}Sv$ to $7.35{\mu}Sv$ before and after wearing the device, and in LAR assessment, we found that thyroid cancer decreased to male 0.14 people (95.12%) and female 0.77 people (95.16%) per one million 10-year old children, and general cancers decreased to male 0.14 people (11.70%) and female 0.25 people (11.70%). Although diagnostic radiation examinations are necessary for healthcare such as the treatment of diseases, based on the ALARA concept, we should strive to optimize medical radiation by using this shielding device actively in the areas of the body unnecessary for the diagnosis.

Ablation of Remnant Thyroid Tissue with I-131 in Well Differentiated Thyroid Cancer After Surgery (분화성 갑상선암에서 수술 후 I-131을 이용한 잔여 갑상선 조직의 제거 성적)

  • Kim, Yu-Kyeong;Lee, Dong-Soo;Cho, Bo-Yeon;Jeong, Jae-Min;Lee, Myung-Chul;Koh, Chang-Soon;Chung, June-Key
    • The Korean Journal of Nuclear Medicine
    • /
    • v.31 no.3
    • /
    • pp.339-345
    • /
    • 1997
  • To evaluate the effectiveness of I-131 in ablation of residual thyroid tissue, we analyzed 350 patients with thyroid cancer who were treated with various doses of I-131 after surgery for thyroid cancer Two hundred fifty five patients were treated with 1.1GBq(30mCi) of I-131 for ablation of remnant thyroid and one hundred seventeen patients received more than 2.8GBq(75mCi) of I-131. We determined the effectiveness of ablation by following I-131 whole body scan. Absent visible uptake or minimal uptake in thyroid tissue were considered as successful ablation. Of 255 patients who received doses of 30mCi I-131 therapy, 131 patients(51%) showed successful ablation of residual thyroid tissue with $2.6{\pm}1.7$ times of I-131 therapy. Of 117 patients who received doses of the more than 75mCi I-131, 84 patients(72%) had successful remnant thyroid ablation with $1.6{\pm}1.1$ times of I-131 therapy, According to the extent of surgery, successful ablation rates were 78%, 62%, 54%, 33% in patients who underwent total thyroidectomy, subtotal thyroidectomy, lobectomy and isthmectomy, lobectomy or tumorectomy, respectively. This study showed that ablation of remnant thyroid after surgery with 30mCi I-131 was successful only in 50%. Therefore, in cases of patients with high risk for recurrence, we recommend high dose I-131 for ablation of remnant after total thyroidectomy.

  • PDF

Fluoroscopic Radiation Exposure during Percutaneous Kyphoplasty

  • Choi, Hyun-Chul
    • Journal of Korean Neurosurgical Society
    • /
    • v.49 no.1
    • /
    • pp.37-42
    • /
    • 2011
  • Objective: The author measured levels of fluoroscopic radiation exposure to the surgeon's body based on the different beam directions during kyphoplasty. Methods: This is an observational study. A series of 84 patients (96 vertebral bodies) were treated with kyphoplasty over one year. The patients were divided into four groups based on the horizontal and vertical directions of the X-Ray beams. We measured radiation exposure with the seven dosimetry badges which were worn by the surgeon in each group (total of 28 badges). Twenty-four procedures were measured in each group. Cumulative dose and dose rates were compared between groups. Results: Fluoroscopic radiation is received by the operator in real-time for approximately 50% (half) of the operation time. Thyroid protectors and lead aprons can block radiation almost completely. The largest dose was received in the chest irrespective of beam directions. The lowest level of radiation were received when X-ray tube was away from the surgeon and beneath the bed (dose rate of head, neck, chest, abdomen and knee: 0.2986, 0.2828, 0.9711, 0.8977, 0.8168 mSv, respectively). The radiation differences between each group were approximately 2.7-10 folds. Conclusion: When fluoroscopic guided-KP is performed, the X-Ray tube should be positioned on the opposite side of the operator and below the table, otherwise the received radiation to the surgeon's body would be 2.7-10 times higher than such condition.

Prospective Observation Study on Hyperthyroidism Patients Treated with Korean Medicine (한의치료를 받은 갑상선 기능 항진증 환자에 대한 전향적 관찰연구)

  • Choi, Yu-jin;Shin, Seon-mi;Han, Yang-hee;Ahn, Se-young;Cho, Chung-sik
    • The Journal of Internal Korean Medicine
    • /
    • v.39 no.1
    • /
    • pp.84-96
    • /
    • 2018
  • Objective: This is aprospective clinical case study that includes the administration of Ahnjeonbaekho-tang (AJBHT) to patients who have suffered from Graves' disease for the 8 weeks of the clinical research. Methods: Without administration of an antithyroid drug, AJBHT was administered 3 times a day for 8 weeks. In Case 1, AJBHT without modification was administered and in Case 2, in accordance with the patients' symptoms, a dose of Gypsum Fibrosum was increased by 4g from the beginning of week 2, and further increased by 16 g, for a total of 20 g between week 6 and week 8. Body mass index (BMI), thyroid function test (TFT), thyroid autoantibody test, complete blood cell count (CBC), and blood chemistry (BC) tests were conducted at an interval of 4 weeks, for a total of 3 times during the study. The clinical manifestations, a spectrum of symptoms of the patients, was observed by Wayne's Index, Euro-QOL-5 Dimension (EQ-5D), and Perceived Stress Scale (PSS). Results: In both cases, an acceptable significance of reduction of value in T3, fT4, Thyroid stimulating antibody (TSAb) and Thyroid stimulating hormone receptor antibody (TSH-R-Ab) was observed. After treatment, in TFT, T3 decreased by 31.66%, fT4 decreased by 32.82% in Case 1, and T3 decreased by 43.42%, and fT4 decreased by 37.32% in Case 2. In the thyroid autoantibody test, TSAb decreased by 7.59%, and TSH-R-Ab decreased by 53.19% in Case 1, and TSAb decreased by 33.45%, TSH-R-Ab decreased by at least 7.75% in Case 2. Besides this, there was a decreasing trend of Wayne's index, and a loss of typical symptoms of hyperthyroidism also declared the efficacy. Conclusion: From these results, AJBHT is very effective in the regulation of TFT and improving the symptoms of hyperthyroidism, and is also expected to be an effective alternative to antithyroid drugs for patients who have side effects or drug intolerance.

Pathological Studies on Ovaries, Thyroid Glands and Hypophyses of Rabbits Following Administration of Sulfadimethoxine (Sulfadimethoxine(SDM) 투여(投與) 가토(家兎)의 난소(卵巢), 갑상선(甲狀腺) 및 뇌하수체(雷下垂體)에 관한 병리학적(病理學的) 연구(硏究))

  • Rim, Byung Moo
    • Korean Journal of Veterinary Research
    • /
    • v.16 no.1
    • /
    • pp.77-96
    • /
    • 1976
  • In order to investigate the effects and acting mechanism on ovaries, thyroid glands and hypophyses of rabbits in short term administration of sulfadimethoxine (SDM) as medical dose, a total of 90 virgin albino rabbits (mean body weight, 1,362g) were selected at random and alloted to two groups. Rabbits in one group served as controls and the others were administered SDM of 50 mg/kg/day for 5 weeks, and then reared without medication for 4 weeks. Pathological changes of the three organs were observed each week for 9 weeks and the results obtained were summarized as follows: 1. Mean body weights of both groups manifested slow increasing tendency but mean hypophysis weights fluctuated throughout the experimental term. Mean ovary weights of experiments were decreased significantly from the 3rd to 6th week but mean thyroid weights of experiments were increased significantly from the 1st to 6th week compared with those of controls. 2. Many ovarian follicles of each developing stage showed follicular atresia accompanying atrophy or necrosis of oocytes and of disintegrated follicular cells. Theca interna cells and sudanophilic interstitial cells showed atrophy and diminished sudanophilic granules and also liquor folliculi were diminished. These changes icreased from the 1st week, remaining so for 5 weeks and returned to normal status in the 8th or 9th week. 3. The thyroid gland showed a typical hyperplastic goiter. Hypertrophic and hyperplastic epithelia follicular manifested cuboidal or columnar form showing tiny or small vacuoles in cytoplasm. The follicles showed atrophy and decreasing colloidal materials. Necrotic and regenerative changes were also present. The interfollicular vessels showed congestion and hemorrhage. These changes increased from the 1st week, remaining so for 5 weeks and returned to normal status in the 9th week. 4. The rates of differential cell counts of hypophyses revealed increase of basophils (gonadotrophs and thyrotrophs) and decrease of chromophobes. Basophils which had diminished granules stainable with HE, PAS and AF revealed hypertrophy, hyperplasia, and increasing of tiny or small vacuoles in cytoplasm. These changes increased from the 1st week, remaining so for 5 weeks and returned to normal status in the 8th or 9th week. As summarized above histologically, administration of SDM led thyrotrophs and gonadotrophs of pituitary glands to hyperactivity but revealed retrogressive and compensatory changes with functional disturbance in ovaries and thyroid glands. These changes were transitional and attributed to direct actions of the drugs on the ovaries and thyroid glands.

  • PDF

Effects of the Thyroid Function on the Adrenal Gland, Hypophysis and Gonads in the Guinea Pigs. 1 Effects of the Thyroid Function on the Adrenal Gland in the Guinea Pigs (Guinea pig의 갑상선기능(甲狀腺機能)이 부신(副腎), 뇌하수체(腦下垂體) 및 생식선(生殖腺)에 미치는 영향(影響) I. Guinea pig의 갑상선(甲狀腺)이 부신(副腎)에 미치는 영향(影響))

  • Lee, Kang Wook;Lee, Kyu Sung;Cheong, Young Chai
    • Korean Journal of Veterinary Research
    • /
    • v.8 no.2
    • /
    • pp.110-116
    • /
    • 1968
  • The mature guinea pigs were grouped as indicated in the table 1. Radio-active iodine(I-131)in dose of 4.5mci, was administered to the experimental groups. The animals were killed for examination in 1, 7, 14, 28, 42, and 55 days after the administration the radio-active iodine. The thyroid and adrenal glands were observed histologically. The results obtained were as follows; 1. One day after the administration, thyroid epithelial cells were abnormally enlarged. After seven days, specimens taken from the middle of the thyroid showed that the follicles and epithelial cells were changing to fibrous tissue, however, some follicles still remained in the verge of the thyroid. Follicles were not observed after fourteen days. After twenty-eight days, the follicles had all changed to fibrous tissue, and had lost their function. 2. The size of the zonas gromerulosa of adrenal cortex epually, in both male and female, showed slight fluctuation in size with no tendency to be changed. 3. Among the zones of the adrenal glands, zona fasciculata showed marked changes. Zona fasciculata was atrophied in Process of time. In females, it was atrophied significantly(P<0.05) after fourteen days, and highly significant (P<0.01) in twenty-eight and fifty-six days after the administration of radioactive iodine. In males, it also decreased significantly(P<0.05) in seventy-eight days and highly significant(P<0.01) in forty-two and fifty-six days after the administration. 4. The size of the Zona reticularis of adrenal cortex in the females increased significantly (P<0.05) in twenty-eight days after the administration. In males, it showed slight fluctuation until twenty-eight days, but it increased significantly(P<0.05) in forty-two and fifty-six days after the administration. 5. The size of the adrenal medulla increased significantly(P<0.05) in twenty-eight and forty-two days in females. It was increased significantly(P<0.05) in fourth-two days and high significantly(P<0.01) in fifty-six days after the administration.

  • PDF

Organ dose reconstruction for the radiation epidemiological study of Korean radiation workers: The first dose evaluation for the Korean Radiation Worker Study (KRWS)

  • Tae-Eun Kwon;Areum Jeong;Wi-Ho Ha;Dalnim Lee;Songwon Seo;Junik Cho;Euidam Kim;Yoonsun Chung;Sunhoo Park
    • Nuclear Engineering and Technology
    • /
    • v.55 no.2
    • /
    • pp.725-733
    • /
    • 2023
  • The Korea Institute of Radiological and Medical Sciences has started a radiation epidemiological study, titled "Korean Radiation Worker Study," to evaluate the health effects of occupational exposure to radiation. As a part of this study, we investigated the methodologies and results of reconstructing organ-specific absorbed doses based on personal dose equivalent, Hp(10), reported from 1984 to 2019 for 20,605 Korean radiation workers. For the organ dose reconstruction, representative exposure scenarios (i.e., radiation energy and exposure geometry) were first determined according to occupational groups, and dose coefficients for converting Hp(10) to organ absorbed doses were then appropriately taken based on the exposure scenarios. Individual annual doses and individual cumulative doses were reconstructed for 27 organs, and the highest values were observed in the thyroid doses (on average 0.77 mGy/y and 10.47 mGy, respectively). Mean values of individual cumulative absorbed doses for the red bone marrow, colon, and lungs were 7.83, 8.78, and 8.43 mSv, respectively. Most of the organ doses were maximum for industrial radiographers, followed by nuclear power plant workers, medical workers, and other facility workers. The organ dose database established in this study will be utilized for organ-specific risk estimation in the Korean Radiation Worker Study.

Radiation Dose and Image Evaluation for Position Change in Low Extremity Teleography (하지전신계측검사에서 자세의 변화에 따른 방사선량 및 영상평가)

  • Kim, Yeongcheon;Song, Jongnam;Choi, Namgil;Jeong, Yeon;Han, Jaebok
    • Journal of the Korean Society of Radiology
    • /
    • v.8 no.7
    • /
    • pp.409-415
    • /
    • 2014
  • In this study, radiation doses of major organs in various postures in lower extremity teleography were measured and compared to investigate the utility of the test methods. Ten adult males who underwent lower extremity teleography at a tube voltage of 73 kVp, tube current of 32 mAs, and SID of 180 cm. Using rando phantom, glass dosimeter was attached to the eye lens, thyroid gland, and genital gland to measure the radiation dose in each area 5 times in each anteroposterior posture and posteroanterior posture. The results were compared and analyzed through Paired T-test. The images from the anteroposterior posture and posteroanterior posture were evaluated through the blind test on a scale of 5. As a result, the posteroanterior method could reduce the dose than the anteroposterior posture method: less dose for the eye lens by 6%, thyroid gland by 6%, and genital gland by 26%. Since there was no significant difference in image evaluation, the posteroanterior posture is considered better than the anteroposterior posture in lower extremity teleography.

Patient radiation dose and protection from cone-beam computed tomography

  • Li, Gang
    • Imaging Science in Dentistry
    • /
    • v.43 no.2
    • /
    • pp.63-69
    • /
    • 2013
  • After over one decade development, cone beam computed tomography (CBCT) has been widely accepted for clinical application in almost every field of dentistry. Meanwhile, the radiation dose of CBCT to patient has also caused broad concern. According to the literature, the effective radiation doses of CBCTs in nowadays market fall into a considerably wide range that is from $19{\mu}Sv$ to $1073{\mu}Sv$ and closely related to the imaging detector, field of view, and voxel sizes used for scanning. To deeply understand the potential risk from CBCT, this report also reviewed the effective doses from literatures on intra-oral radiograph, panoramic radiograph, lateral and posteroanterior cephalometric radiograph, multi-slice CT, and so on. The protection effect of thyroid collar and leaded glasses were also reviewed.