• 제목/요약/키워드: threshold velocity

검색결과 180건 처리시간 0.025초

금을 도우핑한 이중 주입 자기 센서 (Gold-Doped Double Injection Magnetic Sensor)

  • 민남기;이성재
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1995년도 하계학술대회 논문집 C
    • /
    • pp.1248-1251
    • /
    • 1995
  • This paper reports some results of an experimental investigation of planar double injection magnetic sensors. The threshold voltage proved to be very sensitive to an applied magnetic field. The magnitude and direction of the threshold voltage variation depends on the field strength and its orientation with respect to the conduction chennel. The positively-directed field pushes the carriers into the bulk causing an increase in the threhold voltage. These results seem to agree with a path modulation due to Lorentz force. The application of a negative field causes a negative variation, which is dependent on the surface recombination velocity of the silicon-$SiO_2$ interface.

  • PDF

차량의 충돌 유형 및 속도에 따른 에어백 충돌인식 알고리듬에 관한 연구 (A Study on the Airbag Crash Recognition Algorithm for Vechcle Impact Modes and Speeds)

  • 성기안;이창식
    • 한국자동차공학회논문집
    • /
    • 제8권6호
    • /
    • pp.259-266
    • /
    • 2000
  • Crash test data from different impact modes and threshold speeds were used to assess the effects of impact conditions on air bag electronic single point sensing (ESPS) activation requirements. The requirements are expressed in terms of the desired sensor activation time based on unbelted driver dummy kinematics. A crash discriminator pre-displacement is introduced to crash recognition algorithm to the ESPS. The new crash recognition algorithm named Velocity Energy Pre-displacement(VEPD) method is developed and the ESPS algorithm based on the VEPD technique is used to assess the ESPS system performance. It is shown that VEPD method correlates very well with desired sensor activation time and meets the activation requirement.

  • PDF

몬데 칼로 방법을 이용한 실리콘 MOSFET의 드레인영역에서 77 K와 300 K의 Impact Ionization 특성 (Impact Ionization Characteristics Near the Drain of Silicon MOSFET's at 77 and 300 K Using Monte Carlo Method)

  • 이준구;박영준;한민구
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1989년도 추계학술대회 논문집 학회본부
    • /
    • pp.131-135
    • /
    • 1989
  • Hot electron simulation of silicon using Monte Carlo method was carried out to investigate impact ionization characteristics near the drain of MOSFET's at 77 and 300K. We successfully characterized drift velocity and impact ionization at 77 and 300K employing a simplified energy band structure and phonon scattering mechanisms. Woods' soft energy threshold model was introduced to the Monte Carlo simulation of impact ionization, and good agreement with reported experimental results was resulted by employing threshold energy of 1.7 eV. It is suggested that the choice of the critical angle between specular reflection and diffusive scattering of surface roughness scattering may be important in determining the impact ionization charateristics of Monte Carlo simulation near the drain of MOSFET's.

  • PDF

가산 투엽법을 이용한 이동 물체 추적 방법 (A Moving Target Tracking Algorithm Using Integral Projection)

  • 김태원;서일홍;양해원;오상록;임달호
    • 대한전기학회논문지
    • /
    • 제38권7호
    • /
    • pp.569-581
    • /
    • 1989
  • This paper deals with a tracking algorithm based on integral projection which tracks moving targets with varying brightness and size. An adaptive windowing technique is employed to reduce the sensitivity of the system to the complex background image and also to reduce the computational load. The threshold value is determined by considering both the size and the threshold value of the brightness intensity of the recognized target obtained in the previous processing step. Window position is estimated by using the information of the velocity and acceleration of the target. And integral projection is applied to find the position of the target in the window accurately. Experimental results show that moving targets with varying brightness and size can be tracked properly in noisy environments.

  • PDF

넓은 당량비 구간에서 수소함유량에 따른 합성가스(H2/CO)/공기 예혼합화염의 연소속도 및 화염구조에 관한 연구 (A Study on the Laminar Burning Velocity and Flame Structure with H2 Content in a Wide Range of Equivalence Ratio of Syngas(H2/CO)/Air Premixed Flames)

  • 정병규;이기만
    • 한국연소학회지
    • /
    • 제19권1호
    • /
    • pp.17-28
    • /
    • 2014
  • In this study, the laminar burning velocity of syngas fuel($H_2/CO$) and flame structure with various hydrogen contents were studied using both experimental measurements and detailed kinetic analysis. The laminar burning velocities were measured by the angle method of Bunsen flame configuration and the numerical calculations including chemical kinetic analysis were made using CHEMKIN Package with USC-Mech II. A wide range of syngas mixture compositions such as $H_2$ : CO = 10 : 90, 25 : 75, 50 : 50, 75:25 and equivalence ratios from lean condition of 0.5 to rich condition of 5.0 have been considered. The experimental results of burning velocity were in good agreement with previous other research data and numerical simulation. Also, it was shown that the experimental measurements of laminar burning velocity linearly increased with the increment of $H_2$ content although the burning velocity of hydrogen is faster than the carbon monoxide above 10 times. This phenomenon is attributed to the rapid production of hydrogen related radicals such as H radical at the early stage of combustion, which is confirmed the linear increase of radical concentrations on kinetic analysis. Particular concerns in this study are the characteristics of burning velocity and flame structure different from lean condition for rich condition. The decrease of OH radicals and double peaks are observed with $H_2$ content in rich condition once $H_2$ fraction exceeds over threshold.

저출력 레이저조사가 동통반응에 미치는 영향 (EFFECT OF LOW - POWER LASER IRRADIATION ON PAIN RESPONSE)

  • 김성교;윤수한;이종흔
    • Restorative Dentistry and Endodontics
    • /
    • 제16권2호
    • /
    • pp.85-98
    • /
    • 1991
  • The aim of this study was to investigate the effect of low - power laser used in the medical field for various purposes to suppress pain responses evoked by noxious electrical or mechanical stimuli. After both inferior alveolar nerves and the left anterior digastric muscle of cats under general anesthesia were exposed, a recording electrode for the jaw opening reflex was inserted into the anterior digastric muscle. The right inferior alveolar nerve was dissected under a surgical microscope until the response of the functional single nerve could be evoked by the electrical stimulation of the dental pulp or oral mucosa. The electrical stimulus was applied with a rectangular pulse of 10 ms duration for measuring the threshold intensity of a single nerve fiber in the inferior alveolar nerve which responds to stimulation of dental pulp and oral mucosa. Then a pulse of 1 ms duration was applied for determination of conduction velocity. A noxious mechanical stimulus to the oral mucosa was applied by clamping the receptive field with an arterial clamp. The Ga-As diodide laser(wave length, 904 nm ; frequency, 1,000 Hz) was irradiated to the prepared tooth cavity, inferior alveolar nerve and oral mucosa as a pulse wave of 2 mW for 6 minutes. This was followed by a continuous wave of 15 mW for 3 minutes. The action potential of the nerve and EMG of the digastric muscle evoked by the noxious electrical stimulus and nerve response to noxious mechanical stimulus were compared at intervals of before, immediately after, and at 5, 10, 20, 40, 60 minutes after laser irradiation. The results were as follows: The conduction velocity of the intrapulpal $A{\delta}$- nerve fiber recorded from the inferior alveolar nerve before irradiation had a mean value of $6.68{\pm}2.07m/sec$. The laser irradiation did not affect the conduction velocity of the AS - nerve fiber and did not change the threshold intensity or amplitude of the action potential either. The EMG of the digastric muscle evoked by noxious electrical stimulation to the tooth was not changed by the laser irradiation, whether in latency, threshold intensity or amplitude. The laser irradiated to the receptive field of the oral mucosa which was subjected to noxious stimuli did not affect the amplitude of the action potential or the frequency either.

  • PDF

가시광 영역의 저간섭성 광원을 이용한 마이겔슨 간섭계 (Low-coherence non-scanning michelson interferometry using visible broadband light source)

  • 송민호;이병호
    • 전자공학회논문지A
    • /
    • 제33A권10호
    • /
    • pp.160-167
    • /
    • 1996
  • A new pathlength deviation detection technique which is composed of michelson interferometer is described and verified experimentally. The technique uses a sub-threshold biased visible laser diode of 20$\mu$m coherence length as a low-coherent light source. And for zeroth-order fringe(which is the largest among fringes) identification we used a piezoelectric transducer with a large modulation smplitude, which enables without the need of constant velocity scanning, to distinguish reflection surfaces separated by more than 10$\mu$m with a resolution of less than half-wavelength.

  • PDF

지주막하 출혈에 따른 Vasospasm에 대한 Transcranial Doppler의 임상적 적용 (Transcranial Doppler Detection of Vasospasm Following Subarachnoid Hemorrhage)

  • 이준홍
    • Annals of Clinical Neurophysiology
    • /
    • 제1권1호
    • /
    • pp.55-59
    • /
    • 1999
  • Vasoconstriction of intracerebral arteries is the leading cause of delayed cerebral infarction and mortality following aneurysmal subarachnoid hemorrhage. Transcranial Doppler studies show and increase in the flow velocities of basal cerebral arteries, which usually start around day 4 following a subarachnoid hemorrhage, and peaking by days 7 to 14. Angiographic studies confirm the presence of at least some degree of MCA vasospasm when the flow velocities are higher than 100 cm/sec. Mean velocities in the 120 to 200 cm/sec range correspond to 25 to 50% luminal narrowing. MCA and ACA vsospasm is detected with around 90% specificity. Sensitivity is 80% and 50% respectively. A 200cm/sec threshold and rapid flow velocity increase exceeding 50 cm/sec on consecutive days, has been associated with subsequent infarction. Transcranial Doppler is also used to monitor the effects of endovascular treatment of vasospasm. Flow velocities decrease following successful angioplasty or papaverine infusion. Overall, transcranial Doppler studies are considered to have acceptable accuracy for the evaluation of vasospasm in aneurysmal subarachnoid hemorrhage, with limitations that have to be taken into consideration in the clinical setting.

  • PDF

An Experimental Study of Valve Seat Material Galling Characteristics in Waterworks

  • Park, Sung-Jun;Kim, Young-Tae;Lee, Sang-Jo
    • International Journal of Precision Engineering and Manufacturing
    • /
    • 제8권1호
    • /
    • pp.46-51
    • /
    • 2007
  • Environmental contamination creates shortages of potable water. In such situations, the leakage of water due to breakage or aging of rubber valve seats is a serious problem. Rubber is apt to break when it is placed between two materials that contact each other. One way to avoid water leakage due to rubber damage and breakdown is to replace the rubber with metal, which is currently taking place in water distribution systems. In tribology, a severe form of wear is characterized by local macroscopic material transfer or removal, or by problems with sliding protrusions when two solid surfaces experience relative sliding under load. One of the major problems when metal slides is the occurrence of galling. Experimentally, various conditions influence incipient galling, such as hardness, surface roughness, temperature, load, velocity, and the external environment. This study sought to verify the galling tendencies of metal according to its hardness, surface roughness, load, and sliding velocity, and determine the quantitative effect of each factor on the galling tendencies.