• 제목/요약/키워드: three-phase faults

검색결과 108건 처리시간 0.027초

전압, 전류 변화 추이를 이용한 전력용 변압기 보호계전 알고리즘 (A New Protective Relaying Algorithm for Power Transformer Based on Three Phase Voltage and Current)

  • 김상태;이승재;강상희;진보건;윤상현;이태성
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제50권4호
    • /
    • pp.157-165
    • /
    • 2001
  • The two criteria to identify the disturbances of the power transformer has been reported in this paper. They have been derived through EMTP simulations of internal faults, inrush and overexcitation for the model of 154/22.9[kV], 40[MVA], Y-Y three-phase power transformer. We propose the crisp algorithm which uses two criteria. A series of test results clearly indicate that the method can identify not only an internal fault but also the other transients. The average of relay operation times is about 7.2[ms]. The proposed algorithm immunes to the transient state.

  • PDF

Enhanced Startup Diagnostics of LCL Filter for an Active Front-End Converter

  • Agrawal, Neeraj;John, Vinod
    • Journal of Power Electronics
    • /
    • 제18권5호
    • /
    • pp.1567-1576
    • /
    • 2018
  • The reliability of grid-connected inverters can be improved by algorithms capable of diagnosing faults in LCL filters. A fault diagnostic method during inverter startup is proposed. The proposed method can accurately generate and monitor information on the peak value and the location of the peak frequency component of the step response of a damped LCL filter. To identify faults, the proposed method compares the evaluated response with the response of a healthy higher-order damped LCL filter. The frequency components in the filter voltage response are first analytically obtained in closed form, which yields the expected trends for the filter faults. In the converter controller, the frequency components in the filter voltage response are computed using an appropriately designed fast Fourier transform and compared with healthy LCL response parameters using a finite state machine, which is used to sequence the proposed startup diagnostics. The performance of the proposed method is validated by comparing analytical results with the simulation and experimental results for a three-phase grid-connected inverter with a damped LCL filter.

Novel Average Value Model for Faulty Three-Phase Diode Rectifier Bridges

  • Rahnama, Mehdi;Vahedi, Abolfazl;Alikhani, Arta Mohammad;Nahid-Mobarakeh, Babak;Takorabet, Noureddine
    • Journal of Power Electronics
    • /
    • 제19권1호
    • /
    • pp.288-295
    • /
    • 2019
  • Rectifiers are widely used in industrial applications. Although detailed models of rectifiers are usually used to evaluate their performance, they are complex and time-consuming. Therefore, the Average Value Model (AVM) has been introduced to meet the demand for a simple and accurate model. This type of rectifier modeling can be used to simplify the simulations of large systems. The AVM of diode rectifiers has been an area of interest for many electrical engineers. However, healthy diode rectifiers are only considered for average value modeling. By contrast, faults occur frequently on diodes, which eventually cause the diodes to open-circuit. Therefore, it is essential to model bridge rectifiers under this faulty condition. Indeed, conventional AVMs are not appropriate or accurate for faulty rectifiers. In addition, they are significantly different in modeling. In this paper, a novel application of the parametric average value of a three-phase line-commutated rectifier is proposed in which one diode of the rectifier is considered open-circuited. In order to evaluate the proposed AVM, it is compared with experimental and simulation results for the application of a brushless synchronous generator field. The results clearly demonstrate the accuracy of the proposed model.

배전선로 전압강하에 대한 이중 여자 풍력발전시스템 특성 해석 (Analysis of doubly-fed induction generator based wind power system for voltage sag)

  • 차한주;이상회
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 제38회 하계학술대회
    • /
    • pp.1234-1235
    • /
    • 2007
  • This paper represents the generating principles of the doubly-fed induction generator (DFIG) based wind power system and developes a simulation model of DFIG by using PSCAD/EMTDC. In addition, this paper analyzes the steady state operation and the transient operation during the voltage sags in the power common coupling. The voltage sags are occurred by three phase line-to-ground faults and full-voltage startup of an induction motor in the simulation.

  • PDF

Satellite Fault Detection and Isolation Scheme with Modified Adaptive Fading EKF

  • Lim, Jun Kyu;Park, Chan Gook
    • Journal of Electrical Engineering and Technology
    • /
    • 제9권4호
    • /
    • pp.1401-1410
    • /
    • 2014
  • This paper presents a modified adaptive fading EKF (AFEKF) for sensor fault detection and isolation in the satellite. Also, the fault detection and isolation (FDI) scheme is developed in three phases. In the first phase, the AFEKF is modified to increase sensor fault detection performance. The sensor fault detection and sensor selection method are proposed. In the second phase, the IMM filer with scalar penalty is designed to detect wherever actuator faults occur. In the third phase of the FDI scheme, the sub-IMM filter is designed to identify the fault type which is either the total or partial fault. An important feature of the proposed FDI scheme can decrease the number of filters for detecting sensor fault. Also, the proposed scheme can classify fault detection and isolation as well as fault type identification.

3상 전동기 결상에 의한 전기화재 보호를 위한 장치 개발 연구 (A Study on Device Development for Electrical Fire Protection on Open Phase of Three-Phase Motor)

  • 최신형;곽동걸;김진환
    • 한국화재소방학회논문지
    • /
    • 제26권1호
    • /
    • pp.61-67
    • /
    • 2012
  • 3상 전동기를 이용하는 3상 전력계통에서 1상이 결상되면 계통에는 불평형 전류가 흐르거나 단상전력이 공급되어 전동기 코일의 과전류로 인한 화재발생은 물론 전력계통에 큰 피해를 주게 된다. 최근 3상 전동기 결상검출 방식으로는 열동 과전류계전기와 전자식 모터 보호계전기가 대다수 이용되고 있으며, 이들은 선로의 과열이나 과전류가 발생되면 검출하고 차단기를 동작시키는 방식으로 감지속도가 느리고 오동작과 정밀도가 떨어지는 문제점이 있다. 이들을 개선하기위하여 본 논문에서는 반도체 소자를 이용한 새로운 결상보호용 제어회로 토폴로지를 설계하여 감지속도와 정밀도를 향상시키고, 소형 경량으로 제작되어 현장의 3상 전동기 제어반에 용이하게 장착시킬 수 있는 장점이 있다. 그 결과 제안한 결상 보호장치는 3상 전동기를 보호하고 결상으로 발생하는 전기화재를 최소화시키고 그리고 전력계통의 안정적인 운전에 기여할 수 있을 것이다. 제안한 결상 보호장치는 다양한 동작특성 실험을 통하여 그 성능과 신뢰성이 입증된다.

계통사고 시 3상 양방향 AC-DC 컨버터의 동작 분석 (The Operation Analysis of the Three-phase Bi-directional AC-DC Converter during the Grid Faults)

  • 송인범;정두용;이우원;이수원;한기준;원충연
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2011년도 추계학술대회
    • /
    • pp.305-306
    • /
    • 2011
  • 본 논문에서는 3상 양방향 AC-DC 컨버터의 계통사고 검출기법을 제안한다. 3상 양방향 AC-DC 컨버터는 동기좌표법을 이용하여 PLL(Phase locked loop)을 구현하였고, PLL제어에 있어서 dq변환을 수행한다. dq변환은 입력의 크기 정보와 위상정보를 포함하기 때문에 이를 이용하여 계통사고의 검출이 가능하다. 따라서 본 논문에서는 3상 양방향 AC-DC 컨버터를 이용하여, 계통사고에 대한 검출 기법을 제안하였으며, 계통의 d축, q축 전압대하여 사고를 정의하였다.

  • PDF

Fuzzy 추론을 이용한 3상 전력용 변압기 보호계전 알고리즘 (3 phase Power Transformer Protective Relaying Algorithm based on Fuzzy Inference)

  • 김상태;진보건;정상기;이승재;강상희;윤상현;이상윤
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 A
    • /
    • pp.197-199
    • /
    • 2000
  • The various criteria to identify the disturbances of the power transformer has been reported in this paper. They have been derived through EMTP simulations of internal faults, inrush and overexcitation for the model of 154/22.9[kV], 40[MVA], Y-Y three-phase power transformer. We also propose the algorithm which makes bpa Functions and infers the final decision from them based on Modfied Dempster-Shafer's rule of combination.

  • PDF

고조파 성분을 이용한 고저항 지락 사고 검출 기법에 관한 연구 (A Study on High Impedance Fault Detection Method Using Harmonic Components)

  • 유창완;심재철;임화영
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1997년도 하계학술대회 논문집 D
    • /
    • pp.1015-1017
    • /
    • 1997
  • A high impedance fault on the multi-grounded three-phase four-wire distribution system can not be detected by conventional overcurrent sensing devices. In this paper, the neural network is used to detect high impedance faults. The proposed algorithm using back - propagation neural network is demonstrated by simulation with the staged fault test data. The harmonic components of current and the phase of voltage are used as the inputs of neural network. Results of the simulation can be used as a reference for the development of a high impedance fault detector.

  • PDF

Fault Diagnosis of Power Converter for Switched Reluctance Motor based on Discrete Degree Analysis of Wavelet Packet Energy

  • Gan, Chun;Wu, Jianhua;Yang, Shiyou
    • Journal of international Conference on Electrical Machines and Systems
    • /
    • 제2권3호
    • /
    • pp.336-341
    • /
    • 2013
  • Power converter plays a very important role in switched reluctance motor (SRM) systems, and it is also the easiest one to experience failures. Power converter faults will cause the motor to run in non equilibrium states, and a long time fault operation will lead to motor and other modules damaged, and make the system completely lose working stability. This paper uses an asymmetric bridge converter as the research object with three-phase SRM, employs the wavelet packet decomposition for the phase currents. It analyzes and studies the short circuit fault condition of IGBT, uses an energy discrete degree of the wavelet packet nodes as the fault characteristic, and conducts the corresponding experimental and simulation analysis to verify the effectiveness and practicality of the proposed method.