• 제목/요약/키워드: three-dimensional reconstruction

검색결과 458건 처리시간 0.024초

Experimental Study on Satellite Image Restoration for Vanished Area by Dam Construction

  • Yeon, Sang-Ho;Hong, Il-Hwa
    • 대한원격탐사학회:학술대회논문집
    • /
    • 대한원격탐사학회 2003년도 Proceedings of ACRS 2003 ISRS
    • /
    • pp.1424-1426
    • /
    • 2003
  • It will be a real good news for the people who were lost their hometown by the construction of a large dam to be restored to the former state. Focused on Cheung-Pyung around where most part were flooded by the Chungju large Dam founded in early 1980s, we used Remote Sensing Technique in this study in order to restore topographical features before the flood with 3 dimensional effects. We gathered comparatively good satellite photos and remotely sensed digital images, then we made a new color image from these and the topographical map which had been made before the flood. This task was putting together two kinds of different timed images. And then, we generated DEM including the outskirts of that area as harmonizing current contour lines with the map. That could be a perfect 3D image of Cheung-Pyung around before when it had been flood by making perspective images from all directions, north, south, east and west, for showing there in three dimensions. Also, flying simulation we made for close visiting can bring us to experience their real space at that time.

  • PDF

Cone Beam형 CT와 파노라마 영상에서 하악궁의 영상 왜곡 분석 (Analysis of Image Distortion by Mandibular Arch Form in Cone Beam CT and Panoramic Image)

  • 정천수;이기흔
    • 한국방사선학회논문지
    • /
    • 제7권4호
    • /
    • pp.301-305
    • /
    • 2013
  • Cone Beam CT 데이터를 3차원 컴퓨터 프로그램을 이용하여 기존의 파노라마 영상과 재구성된 파노라마 영상을 재현해서 악궁형태에 따른 치아의 왜곡을 분석하고자 하였다. Cone Beam CT의 횡단면 영상과 재구성 파노라마에서 측정된 치아의 직경은 전치부에서 구치부로 갈수록 큰 변화없이 일치되는 것을 알 수 있었다. 하지만 파노라마는 전치부에서 약간의 왜곡이 보이다가 구치부로 갈수록 왜곡이 더 심한 것을 알 수 있었다. 환자 개개인의 악궁에 맞게 재구성된 파노라마가 일반적으로 사용되는 파노라마 촬영보다 왜곡이 더 감소한다는 것을 알 수 있었다. 또한 파노라마는 전치부에서 구치부로 갈수록 왜곡이 더 심해지는 것을 알 수 있었는데, 이 또한 재구성된 파노라마 영상에서는 왜곡이 감소한다는 것을 알 수 있었다.

디지털 홀로그래피에서의 공초점 렌즈계를 이용한 보다 큰 물체의 기록 (Recording of larger object by using two confocal lenses in digital holography)

  • 김성규;최현희;손정영
    • 한국광학회지
    • /
    • 제14권3호
    • /
    • pp.244-248
    • /
    • 2003
  • 공초점 렌즈의 조합으로 사용되는 두 렌즈의 초점거리의 비율에 해당하는 비율 만큼 입사되는 광의 입사각을 줄일 수 있다. 이 결과로 CCD상의 간섭 패턴의 공간 주파수가 낮아진다. 따라서 CCD의 구성 화소들의 간격에 의해 한정되는 기록 가능한 공간 주파수 보다 높은 공간 주파수의 간섭 패턴을 기록할 수 있어 보다 큰 물체의 간섭 패턴을 기록할 수 있다. 또한 이러한 광학계로 기록한 간섭 패턴의 수치적 재생(Numerical Reconstrction) 결과에서는 0-차 회절광의 면적이 초점거리 비율의 역수의 제곱에 해당하는 만큼 축소되는 장점이 있다.

Real 3D Property Integral Imaging NFT Using Optical Encryption

  • Lee, Jaehoon;Cho, Myungjin;Lee, Min-Chul
    • Current Optics and Photonics
    • /
    • 제6권6호
    • /
    • pp.565-575
    • /
    • 2022
  • In this paper, we propose a non-fungible token (NFT) transaction method that can commercialize the real 3D property and make property sharing possible using the 3D reconstruction technique. In addition, our proposed method enhances the security of NFT copyright and metadata by using optical encryption. In general, a conventional NFT is used for 2D image proprietorial rights. To expand the scope of the use of tokens, many cryptocurrency industries are currently trying to apply tokens to real three-dimensional (3D) property. However, many token markets have an art copyright problem. Many tokens have been minted without considering copyrights. Therefore, tokenizing real property can cause significant social issues. In addition, there are not enough methods to mint 3D real property for NFT commercialization and sharing property tokens. Therefore, we propose a new token management technique to solve these problems using integral imaging and double random phase encryption. To show our system, we conduct a private NFT market using a test blockchain network that can demonstrate the whole NFT transaction process.

Full-color Non-hogel-based Computer-generated Hologram from Light Field without Color Aberration

  • Min, Dabin;Min, Kyosik;Park, Jae-Hyeung
    • Current Optics and Photonics
    • /
    • 제5권4호
    • /
    • pp.409-420
    • /
    • 2021
  • We propose a method to synthesize a color non-hogel-based computer-generated-hologram (CGH) from light field data of a three-dimensional scene with a hologram pixel pitch shared for all color channels. The non-hogel-based CGH technique generates a continuous wavefront with arbitrary carrier wave from given light field data by interpreting the ray angle in the light field to the spatial frequency of the plane wavefront. The relation between ray angle and spatial frequency is, however, dependent on the wavelength, which leads to different spatial frequency sampling grid in the light field data, resulting in color aberrations in the hologram reconstruction. The proposed method sets a hologram pixel pitch common to all color channels such that the smallest blue diffraction angle covers the field of view of the light field. Then a spatial frequency sampling grid common to all color channels is established by interpolating the light field with the spatial frequency range of the blue wavelength and the sampling interval of the red wavelength. The common hologram pixel pitch and light field spatial frequency sampling grid ensure the synthesis of a color hologram without any color aberrations in the hologram reconstructions, or any loss of information contained in the light field. The proposed method is successfully verified using color light field data of various test or natural 3D scenes.

Open Reduction of an Isolated Anterior Nasal Spine Fracture: A Case Report and Review of the Literature

  • Jinwoo Park;In Sik Yun;Tai Suk Roh;Young Seok Kim
    • Archives of Plastic Surgery
    • /
    • 제50권4호
    • /
    • pp.389-392
    • /
    • 2023
  • A 14-year-old girl had a midfacial trauma event caused by hitting against an opening door and experienced discomfort and swelling of the columella and upper lip. Physical examination revealed mild tenderness on light palpation without any discomfort with upper lip movement. A computed tomography scan of the maxillofacial bones with three-dimensional reconstruction showed a fracture of the anterior nasal spine with obvious leftward displacement, mild-deviation of the caudal aspect of the nasal septum, and no sign of nasal bone fracture. Open reduction and internal fixation was performed with regard to aesthetic and functional concerns, including nasal septum deviation. The postoperative course was uneventful, and healing proceeded normally without complications. Herein, we emphasize the importance of differential diagnosis of isolated anterior nasal spine fractures in patients with midfacial trauma and clinicians' strategic decision-making in treatment modalities.

Scanning acoustic microscopy for material evaluation

  • Hyunung Yu
    • Applied Microscopy
    • /
    • 제50권
    • /
    • pp.25.1-25.11
    • /
    • 2020
  • Scanning acoustic microscopy (SAM) or Acoustic Micro Imaging (AMI) is a powerful, non-destructive technique that can detect hidden defects in elastic and biological samples as well as non-transparent hard materials. By monitoring the internal features of a sample in three-dimensional integration, this technique can efficiently find physical defects such as cracks, voids, and delamination with high sensitivity. In recent years, advanced techniques such as ultrasound impedance microscopy, ultrasound speed microscopy, and scanning acoustic gigahertz microscopy have been developed for applications in industries and in the medical field to provide additional information on the internal stress, viscoelastic, and anisotropic, or nonlinear properties. X-ray, magnetic resonance, and infrared techniques are the other competitive and widely used methods. However, they have their own advantages and limitations owing to their inherent properties such as different light sources and sensors. This paper provides an overview of the principle of SAM and presents a few results to demonstrate the applications of modern acoustic imaging technology. A variety of inspection modes, such as vertical, horizontal, and diagonal cross-sections have been presented by employing the focus pathway and image reconstruction algorithm. Images have been reconstructed from the reflected echoes resulting from the change in the acoustic impedance at the interface of the material layers or defects. The results described in this paper indicate that the novel acoustic technology can expand the scope of SAM as a versatile diagnostic tool requiring less time and having a high efficiency.

Patient-specific implants in reverse shoulder arthroplasty

  • Emil R Haikal;Mohamad Y. Fares;Joseph A. Abboud
    • Clinics in Shoulder and Elbow
    • /
    • 제27권1호
    • /
    • pp.108-116
    • /
    • 2024
  • Reverse total shoulder arthroplasty (RTSA) is widely popular among shoulder surgeons and patients, and its prevalence has increased dramatically in recent years. With this increased use, the indicated pathologies associated with RTSA are more likely to be encountered, and challenging patient presentations are more likely to be seen. One prominent challenging presentation is RTSA patients with severe glenoid bone loss. Several techniques with varying degrees of invasiveness, including excessive reaming, alternate centerline, bone grafting, and patient-specific implants (PSIs), have been developed to treat patients with this presentation. PSI treatment uses a three-dimensional reconstruction of a computed tomography scan to design a prosthetic implant or component customized to the patient's glenoid morphology, allowing compensation for any significant bone loss. The novelty of this technology implies a paucity of available literature, and although many studies show that PSIs have good potential for solving challenging shoulder problems, some studies have reported questionable and equivocal outcomes. Additional research is needed to explore the indications, outcomes, techniques, and cost-efficiency of this technology to help establish its role in current treatment guidelines and strategies.

Point-based surface best fit 알고리즘을 이용한 디지털 치아 모형과 3차원 CT 영상의 중첩 정확도 (IMAGE FUSION ACCURACY FOR THE INTEGRATION OF DIGITAL DENTAL MODEL AND 3D CT IMAGES BY THE POINT-BASED SURFACE BEST FIT ALGORITHM)

  • 김봉철;이채은;박원서;강정완;이충국;이상휘
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제34권5호
    • /
    • pp.555-561
    • /
    • 2008
  • Purpose: The goal of this study was to develop a technique for creating a computerized composite maxillofacial-dental model, based on point-based surface best fit algorithm and to test its accuracy. The computerized composite maxillofacial-dental model was made by the three dimensional combination of a 3-dimensional (3D) computed tomography (CT) bone model with digital dental model. Materials and Methods: This integration procedure mainly consists of following steps : 1) a reconstruction of a virtual skull and digital dental model from CT and laser scanned dental model ; 2) an incorporation of dental model into virtual maxillofacial-dental model by point-based surface best fit algorithm; 3) an assessment of the accuracy of incorporation. To test this system, CTs and dental models from 3 volunteers with cranio-maxillofacial deformities were obtained. And the registration accuracy was determined by the root mean squared distance between the corresponding reference points in a set of 2 images. Results and Conclusions: Fusion error for the maxillofacial 3D CT model with the digital dental model ranged between 0.1 and 0.3 mm with mean of 0.2 mm. The range of errors were similar to those reported elsewhere with the fiducial markers. So this study confirmed the feasibility and accuracy of combining digital dental model and 3D CT maxillofacial model. And this technique seemed to be easier for us that its clinical applicability can good in the field of digital cranio-maxillofacial surgery.

폴리우레탄 폼 드레싱재료를 이용한 간단한 손가락 섬피판 디자인 (Polyurethane Foam Template for Simple Design of Digital Island Flap)

  • 김남중;최환준;김준혁
    • Archives of Reconstructive Microsurgery
    • /
    • 제18권1호
    • /
    • pp.35-39
    • /
    • 2009
  • Purpose: Various techniques have been attempted for design of the flaps. However, there are some disadvantages. They have thin, pliable, and two dimensional methods. The aim of this study is to report usefulness of polyurethane foam dressing materials for three dimensional design of the digital island flap. Methods: From June of 2007 to september of 2008, 10 patients received digital island flap surgery for soft tissue defect of the finger. After minimal debridement of the wound, size and shape of the defect were measured using polyurethane foam. We used Medifoam-$5^{(R)}$ And then, designed this inset the wound. The flap was designed on the donor site with a arterial pedicle as the central axis according to size and shape. A full thickness skin graft from the groin is applied on the flap donor defect and secured with a tieover bolster dressing. Results: Reviewing sizes of the flaps, the length and width of flaps ranged from 1.5 to 3.3 cm and 1.0 to 2.5 cm. The PACS(Picture Archiving Communication System) program allows identification of the donor depth of finger. The distance for the soft tissue ranged from 4.3 mm to 6.7 mm. Mean depth of donor site was 5.3${\pm}$0.6 mm. Also, the thickness of Medifoam-$5^{(R)}$ ranged nearly 5 mm. On flap insetting, full-thickness skin graft was necessary. We did not experience any problems in the recipient site size either, regardless of the extended flaps. Conclusion: Polyurethane foam has many advantages over the more conventional templates. Refinements in flap design and surgical technique resulted in favorable functional and cosmetic results. Especially, for beginner, Polyurethane foam dressing material is a simple and safe tool and therefore is an excellent choice for design of the island flap.

  • PDF