Objective : Bilateral C1 lateral mass and C2 pedicle screw fixation (C1LM-C2P) is an ideal technique for correcting atlantoaxial instability (AAI). However, the inevitable situation of vertebral artery injury or unfavorable bone structure may necessitate the use of unilateral C1LM-C2P. This study compares the fusion rates of the C1 lateral mass and C2 pedicle screw in the unilateral and bilateral methods. Methods : Over five years, C1LM-C2P was performed in 25 patients with AAI in our institute. Preoperative studies including cervical X-ray, three-dimensional computed tomography (CT), CT angiogram, and magnetic resonance imaging were performed. To evaluate bony fusion, measurements of the atlanto-dental interval (ADI) and CT scans were performed in the preoperative period, immediate postoperative period, and postoperatively at 1, 3, 6, and 12 months. Results : Unilateral C1LM-C2P was performed in 11 patients (44%). The need to perform unilateral C1LM-C2P was due to anomalous course of the vertebral artery in eight patients (73%) and severe degenerative arthritis in three patients (27%). The mean ADI in the bilateral group was 2.09 mm in the immediate postoperative period and 1.75 mm in 12-months postoperatively. The mean ADI in the unilateral group was 1.82 mm in the immediate postoperative period and 1.91 mm in 12-months postoperatively. Comparison of ADI measurements showed no significant differences in either group (p=0.893), and the fusion rate was 100% in both groups. Conclusion : Although bilateral C1LM-C2P is effective for AAI from a biomechanical perspective, unilateral screw fixation is a useful alternative in patients with anatomical variations.
Sung, Ji Yoon;Cho, Kyu-Sup;Bae, Yong Chan;Bae, Seong Hwan
대한두개안면성형외과학회지
/
제21권1호
/
pp.64-68
/
2020
The coexistence of craniofacial cleft and bilateral choanal atresia has only been reported in three cases in the literature, and only one of those cases involved a Tessier number 3 facial cleft. It is also rare for bilateral choanal atresia to be found in adulthood, with 10 previous cases reported in the literature. This report presents the case of a 19-year-old woman with a Tessier number 3 facial cleft who was diagnosed with bilateral choanal atresia in adulthood. At first, the diagnosis of bilateral choanal atresia was missed and septoplasty was performed. After septoplasty, the patient's symptoms did not improve, and an endoscopic examination revealed previously unnoticed bilateral choanal atresia. Computed tomography showed left membranous atresia and right bony atresia. The patient underwent an operation for opening and widening of the left choana with an image-guided navigation system (IGNS), which enabled accurate localization of the lesion while ensuring patient safety. Postoperatively, the patient became able to engage in nasal breathing and reported that it was easier for her to breathe, and there were no signs of restenosis at a 26-month follow-up. The patient was successfully treated with an IGNS.
Purpose: To investigate the relationship between 3D bone architectural parameters and direction-related elastic moduli of cancellous bone of mandibular condyle. Materials and Methods: Two micro-pigs (Micro-$pig^R$, PWG Genetics Korea) were used. Each pig was about 12 months old and weighing around 44 kg. 31 cylindrical bone specimen were obtained from cancellous bone of condyles for 3D analysis and measured by micro-computed tomography. Six parameters were trabecular thickness (Tb. Th), bone specific surface (BS/BV), percent bone volume (BV/TV), structure model index (SMI), degree of anisotropy (DA) and 3-dimensional fractal dimension (3DFD). Elastic moduli of three orthogonal directions (superior-inferior (SI), medial-lateral (ML), andterior-posterior (AP) direction) were calculated through finite element analysis. Results: Elastic modulus of superior-inferior direction was higher than those of other directions. Elastic moduli of 3 orthogonal directions showed different correlation with 3D architectural parameters. Elastic moduli of SI and ML directions showed significant strong to moderate correlation with BV/TV, SMI and 3DFD. Conclusion: Elastic modulus of cancellous bone of pig mandibular condyle was highest in the SI direction and it was supposed that the change into plate-like structure of trabeculae was mainly affected by increase of trabeculae of SI and ML directions.
2개의 시분할 8시점 영상 채널을 공간적으로 시역을 결합시킴에 의해 16시점 3차원 영상 시스템을 설계했다. 각각의 8시점 채널을 빛의 3원색(빨강, 초록 그리고 파랑)에 대응하는 빛을 발산하는 3개의 CRT들을 한 개의 채널로 결합해주는 이색 빔 분할기(dichroic beam splitter)로 이루어져 있고 각각의 CRT는 8시점의 영상을 시간분할 방식에 의해 표시하며, 각 채널별 영상은 투사광학계를 통과하여 1$\times$0.8$m^2$ 크기의 홀로그래픽 스크린에 투영된다. 이 시스템을 위한 최적 투사광학계를 설계하기 위해 시스템에 적용 가능한 3개의 서로 다른 투사광학계에 대해 그 특성을 광학 설계 프로그램인“ DEMOS ”를 사용하여 시험했다. 설계 시스템의 최적 투사광학계는 각 채널별 영상을 양면 반사경(two-folded mirror)에 의해 결합하여 16개의 띠형 액정 셔터로 구성된 한 개의 LCD 셔터를 통해 투사용 대물렌즈로 입사시키는 구조를 가지는 것이 최적임을 보였다. 단 이 구조에서 셔터는 투사용 대물렌즈의 입력개구(entrance pupil)에 위치해야하며, 양면 반사경의 접혀진 선은 이 셔터의 중심과 맞닿아 대칭이 되도록 위치해야 한다.
Objectives : The purpose of this study is to find the effects of Sa-am liver tonifying and sedating acupuncture on radial pulse. Methods : Sixty healthy people were divided into a liver tonifying acupuncture(LTA) group, liver sedating acupuncture(LSA) group, and control group. The LTA group and LSA group received acupuncture for 20 minutes with a supine position. The Control group took a rest without receiving acupuncture. Radial pulse was measured by three dimensional pulse imaging system(DMP-3000) at four different time points (before, right after, 30 minutes after, and 60 minutes after acupuncture). We compared the three groups and figure out determined the parameters which significantly changed after acupuncture treatment. Results : 1. Pulse period, T1/T, T4/T, (T-T4)/T, T4/(T-T4), T5/T significantly changed after acupuncture. 2. H4, pulse area, systolic pulse area, diastolic pulse area, radial augmentation index(RAI), and pulse power volume / min significantly changed after acupuncture. 3. Frequency of Fourier components, ratio of frequencies of Fourier components, magnitude of Fourier components, and ratio of magnitudes of Fourier components significantly changed after acupuncture. Conclusions : LTA and LSA have an effect on the radial pulse parameters. Further studies on radial pulse change using Sa-Am acupuncture are needed.
Objective : Computed tomography (CT)-based method of three dimensional (3D) analysis ($MIMICS^{(R)}$, Materialise, Leuven, Belgium) is reported as very useful software for evaluation of OPLL, but its reliability and reproducibility are obscure. This study was conducted to evaluate the accuracy of $MIMICS^{(R)}$ system, and inter- and intra-observer reliability in the measurement of OPLL. Methods : Three neurosurgeons independently analyzed the randomly selected 10 OPLL cases with medical image processing software ($MIMICS^{(R)}$) which create 3D model with Digital Imaging and Communication in Medicine (DICOM) data from CT images after brief explanation was given to examiners before the image construction steps. To assess the reliability of inter- and intra-examiner intraclass correlation coefficient (ICC), 3 examiners measured 4 parameters (volume, length, width, and length) in 10 cases 2 times with 1-week interval. Results : The inter-examiner ICCs among 3 examiners were 0.996 (95% confidence interval [CI], 0.987-0.999) for volume measurement, 0.973 (95% CI, 0.907-0.978) for thickness, 0.969 (95% CI, 0.895-0.993) for width, and 0.995 (95% CI, 0.983-0.999) for length. The intra-examiner ICCs were 0.994 (range, 0.991-0.996) for volume, 0.996 (range, 0.944-0.998) for length, 0.930 (range, 0.873-0.947) for width, and 0.987 (range, 0.985-0.995) for length. Conclusion : The medical image processing software ($MIMICS^{(R)}$) provided detailed quantification OPLL volume with minimal error of inter- and intra-observer reliability in the measurement of OPLL.
Background Lymphaticovenular anastomosis (LVA) is a minimally invasive surgical procedure used to treat lymphedema. Volumetric measurements and quality-of-life assessments are often performed to assess the effectiveness of LVA, but there is no method that provides information regarding postoperative morphological changes in lymphatic vessels and veins after LVA. Photoacoustic lymphangiography (PAL) is an optical imaging technique that visualizes the distribution of light-absorbing molecules, such as hemoglobin or indocyanine green (ICG), and provides three-dimensional images of superficial lymphatic vessels and the venous system simultaneously. In this study, we performed PAL in lymphedema patients before and after LVA and compared the images to evaluate the effect of LVA. Methods PAL was performed using the PAI-05 system in three patients (one man, two women) with lymphedema, including one primary case and two secondary cases, before LVA. ICG fluorescence lymphography was performed in all cases before PAL. Follow-up PAL was performed between 5 days and 5 months after LVA. Results PAL enabled the simultaneous visualization of clear lymphatic vessels that could not be accurately seen with ICG fluorescence lymphography and veins. We were also able to observe and analyze morphological changes such as the width and the number of lymphatic vessels and veins during the follow-up PAL after LVA. Conclusions By comparing preoperative and postoperative PAL images, it was possible to analyze the morphological changes in lymphatic vessels and veins that occurred after LVA. Our study suggests that PAL would be useful when assessing the effect of LVA surgery.
Purpose: The transverse abdominis and themultifidus muscle are located in the core. They surround one's trunk and help in body stabilization. Specifically, they control spine articulation to maintain posture and balance. Therefore, weakened deep muscle in the trunk may cause spinal malalignment. This study aims to compare the correlation between the thickness of the transverse abdominis and the multifidus muscle and the spine alignment among college students in their 20s. Methods: This study measured the thickness of the transverse abdominis and the multifidus muscle of 42 healthy college students in their 20s using ultrasonic waves. The thickness of the muscle was measured for the length of the cross-section except for fascia. The thickness of the left and right muscles was measured, and the mean value was calculated. As the thickness of the transverse abdominis can increase because of pressure during exhalation, it was measured at the last moment of exhalation. Spinal alignment was measured by the kyphosis angle, lordosis angle, pelvic tilt, trunk inclination, lateral deviation, trunk imbalance, and surface rotation using Formetric III, which is a three-dimensional imaging equipment. They were measured for three times, and the mean values were calculated. The general characteristics of the subjects were analyzed using descriptive statistics. The correlations between each factor were analyzed using Pearson's correlation analysis. Results: The transverse abdominis showed asignificant correlation with trunk inclination (p<.05). The multifidus muscle showed a significant positive correlation with pelvic tilt and a negative correlation with surface rotation (p<.05). Conclusion: The thickness of transverse abdominis and the multifidus muscle appears to influence spinal alignment. Specifically, the multifidus muscle, which plays an important role on the sagittal plane, influences surface rotation, thus making it an important muscle for scoliosis patients. Therefore, a strengthening training program for the transverse abdominis and the multifidus muscle is necessary according to specific purposes among adults with spinal malalignment.
본 연구에서는 화강암 시편을 대상으로 파쇄 유체의 점성과 주입 속도를 변화시키며 실내 수압 파쇄 실험을 수행하였고, 3D X-ray CT 촬영을 통해 파쇄 후 시편 내부를 관찰하였다. 이미지 처리에 탁월한 성능을 보이는 합성곱 신경망(Convolutional Neural Network, CNN) 기반 Nested U-Net 모델 구조를 활용하여 CT 이미지 내 수압 파쇄 균열 추출을 수행하였고, 복잡한 형상의 미세균열을 정교하게 추출할 수 있었다. CNN 기반 모델로 추출된 균열을 3차원으로 재구성하여 균열의 부피, 두께, 굴곡도, 균열면 거칠기를 분석하였다. 그 결과 파쇄 유체의 점성이 클수록 균열 부피와 두께가 증가하였고, 굴곡도와 균열면의 거칠기가 감소하는 경향을 보였다. 또한 균열면의 굴곡도와 거칠기 이방성이 존재함을 확인할 수 있었다. 본 연구는, CNN 기반의 균열 추출 모델을 활용해 전통적인 이미지 처리 방법보다 정교한 균열 추출을 수행하고, 이를 기반으로 수압 파쇄 균열의 정량 분석을 성공적으로 수행하였다.
The initial motivation in colloid science and engineering was driven by the fact that colloids can serve as excellent models to study atomic and molecular behavior at the mesoscale or microscale. The thermal behaviors of actual atoms and molecules are similar to those of colloids at the mesoscale or microscale, with the primary distinction being the slower dynamics of the latter. While atoms and molecules are challenging to observe directly in situ, colloidal motions can be easily monitored in situ using simple and versatile optical microscopic imaging. This foundational approach in colloid research persisted until the 1980s, and began to be extensively implemented in optics and photonics research in the 1990s. This shift in research direction was brought by an interplay of several factors. In 1987, Yablonovitch and John modernized the concept of photonic crystals (initially conceptualized by Lord Rayleigh in 1887). Around this time, mesoscale dielectric colloids, which were predominantly in a suspended state, began to be self-assembled into three-dimensional (3D) crystals. For photonic crystals operating at optical frequencies (visible to near-infrared), mesoscale crystal units are needed. At that time, no manufacturing process could achieve this, except through colloidal self-assembly. This convergence of the thirst for advances in optics and photonics and the interest in the expanding field of colloids led to a significant shift in the research paradigm of colloids. Initially limited to polymers and ceramics, colloidal elements subsequently expanded to include semiconductors, metals, and DNA after the year 2000. As a result, the application of colloids extended beyond dielectric-based photonic crystals to encompass plasmonics, metamaterials, and metasurfaces, shaping the present field of colloidal optics and photonics. In this review we aim to introduce the research trajectory of colloidal optics and photonics over the past three decades; To elucidate the utility of colloids in photonic crystals, plasmonics, and metamaterials; And to present the challenges that must be overcome and potential research prospects for the future.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.