• Title/Summary/Keyword: three-dimensional gait analysis

Search Result 84, Processing Time 0.028 seconds

Musculoskeletal model during isokinetic knee motion;Simulation and Experiment (슬관절 등속 운동시 하지근육구동모델;모의실험과 임상실험)

  • Bae, Tae-Soo;Cho, Hyeon-Seok;Kang, Sung-Jae;Choi, Kyong-Joo;Kim, Shin-Ki;Mun, Mu-Seong
    • Proceedings of the KSME Conference
    • /
    • 2003.11a
    • /
    • pp.1554-1559
    • /
    • 2003
  • This study validated the musculoskeletal model of the human lower extremity by comparative study between calculated muscle parameters through simulation using modified hill-type model and measured them through isokinetic exercise. And the relationship between muscle forces and moments participated in motion was quantified from the results of simulation. For simulation of isokinetic motion, a three-dimensional anatomical knee model was constructed using trials of gait analysis and the EMG-force model was used to determine muscle activation level exciting muscles. The modified Hill-type model was used to calculate individual muscle forces and moments in dynmaic analysis and the results were validated by comparing them of experiments on BIODEX. The results showed that there was a high correlation between calculated torques from simulation and measured them from experiments for isokinetic motion(R=0.97). Therefore we concluded that the simulation by using musculoskeletal model was so useful means to predict and convalesce musculoskeletal-related diseases, and analyze unrealizable experiment such as clash condition.

  • PDF

PERIPHERAL NERVE REGENERATION USING A THREE-DIMENSIONALLY CULTURED SCHWANN CELL CONDUIT (삼차원 배양된 슈반세포 도관을 이용한 말초 신경 재생)

  • Kim, Soung-Min;Lee, Jong-Ho
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.30 no.1
    • /
    • pp.1-16
    • /
    • 2004
  • The use of artificial nerve conduit containing viable Schwann cells is one of the most promising strategies to repair the peripheral nerve injury. To fabricate an effective nerve conduit whose microstructure and internal environment are more favorable in the nerve regeneration than existing ones, a new three-dimensional Schwann cell culture technique using $Matrigel^{(R)}$. and dorsal root ganglion (DRG) was developed. Nerve conduit of three-dimensionally arranged Schwann cells was fabricated using direct seeding of freshly harvested DRG into a $Matrigel^{(R)}$ filled silicone tube (I.D. 1.98 mm, 14 mm length) and in vitro rafting culture for 2 weeks. The nerve regeneration efficacy of three-dimensionally cultured Schwann cell conduit (3D conduit group, n=6) was assessed using SD rat sciatic nerve defect of 10 mm, and compared with that of silicone conduit filled with $Matrigel^{(R)}$ and Schwann cells prepared from the conventional plain culture method (2D conduit group, n=6). After 12 weeks, sciatic function was evaluated with sciatic function index (SFI) and gait analysis, and histomorphology of nerve conduit and the innervated tissues of sciatic nerve were examined using image analyzer and electromicroscopic methods. The SFI and ankle stance angle (ASA) in the functional evaluation were $-60.1{\pm}13.9$, $37.9^{\circ}{\pm}5.4^{\circ}$ in 3D conduit group (n=5) and $-87.0{\pm}12.9$, $32.2^{\circ}{\pm}4.8^{\circ}$ in 2D conduit group (n=4), respectively. And the myelinated axon was $44.91%{\pm}0.13%$ in 3D conduit group and $13.05%{\pm}1.95%$ in 2D conduit group to the sham group. In the TEM study, 3D conduit group showed more abundant myelinated nerve fibers with well organized and thickened extracellular collagen than 2D conduit group, and gastrocnemius muscle and biceps femoris tendon in 3D conduit group were less atrophied and showed decreased fibrosis with less fatty infiltration than 2D conduit group. In conclusion, new three-dimensional Schwann cell culture technique was established, and nerve conduit fabricated using this technique showed much improved nerve regeneration capacity than the silicone tube filled with $Matrigel^{(R)}$ and Schwann cells prepared from the conventional plain culture method.

The Effects of Different Angles of Wedged Insoles on Knee Varus Torque in Healthy Subjects

  • Jung, Do-Young;Kwon, Oh-Yun;Yi, Chung-Hwi;Kim, Young-Ho;Kim, Jang-Hwan
    • Physical Therapy Korea
    • /
    • v.11 no.4
    • /
    • pp.31-41
    • /
    • 2004
  • The purpose of this study was to examine the effect of the angle of a wedged insole on knee varus torque during walking. Fifteen healthy subjects were recruited. Knee varus torque was measured using three-dimensional motion analysis (Elite). Knee varus torque was normalized to gait cycle (0%: initial contact; 100%: ipsilateral initial contact) and stance phase (0%: initial contact; 100%: ipsilateral toe off). The average peaks of knee varus torque during the stance phase of the gait cycle according to the different insole angles (10 or 15 degrees) were compared using one-way ANOVA with repeated measures. The results showed that in the early stance phase, the average peak knee varus torque increased significantly for both the medial 10 and 15 degree wedged insole conditions and decreased significantly for both the lateral 10 and 15 degree wedged insole conditions as compared with no insole (p<.05). However, there were no significant differences between the 10 and 15 degree wedged insole conditions with either the medial or lateral wedged insole (p>.05). In the late stance phase, the average peak knee varus torque increased significantly for the medial 10 and 15 degree wedged insole conditions (p<.05), but not for the lateral 10 and 15 degree wedged insole conditions as compared with no insole (p>.05). We suggest that these results may be beneficial for manufacturing foot orthotic devices, such as wedged insoles, to control medial and lateral compartment forces in the knee varus-valgus deformity. Further studies of the effects of wedged insole angle on knee varus torque in patients with medial-lateral knee osteoarthritis are needed.

  • PDF

The Stress Distribution Property on the Customized Ankle Foot Orthoses During the Gait Period (보행주기에 따른 맞춤형 단하지보조기의 응력분포 특성)

  • Choi, Young-Chul;Rhee, Kun-Min;Choi, Hwa-Soon
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.25 no.3
    • /
    • pp.165-175
    • /
    • 2008
  • An ankle-foot orthosis(AFO) is a brace for persons with gait disabilities to support or replace the function of ankle joint. Ankle-foot orthoses(AFO's) are usually prescribed to alleviate the drop-foot by constraining the excessive plantar flexion. The shape and the strength of the AFO are often based on 'trial and error' due to a lack of knowledge of the stress distribution in the AFO. In this study, an improved stress-freezing method was proposed to measure the stress distribution characteristics in the AFO. As a result, a photoelastic material with low freezing temperature was developed to measure the stresses under a person's direct contact loading condition. The three-dimensional stress-1rozen photoelastic models of AFO's for five stages of stance phase such as heel contact, foot flat, mid stance, heel off, and toe off were produced. The results of photoelastic analysis revealed that the stresses developed in the AFO were varied considerably from tensile to compressive or vice versa, during walking. At the posterior part of ankle joint in the AFO, the maximum compressive stress of 1.81MPa was observed in the mid stance, and the maximum tensile stress of 0.74MPa was observed during heel contact. The overall stress levels in the AFO's were low in the toe off phase. The results suggested that the posterior part of ankle joint might be the most fragile part in the AFO.

A Development of an Insole Type Local Shear Measurement Transducer and Measurements of Local Plantar Shear Force During Gait (인솔형 국부 전단센서의 개발 및 보행 시 발바닥의 국부 전단력 측정)

  • Jeong Im Sook;Ahn Seung Chan;Yi Jin Bok;Kim Han Sung;Kim Young Ho
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.22 no.6 s.171
    • /
    • pp.213-221
    • /
    • 2005
  • An insole type local shear force measurement system was developed and local shear stresses in the foot were measured during level walking. The shear force transducer based on the magneto-resistive principle, was a rigid 3-layer circular disc. Sensor calibrations with a specially designed calibration device showed that it provided relatively linear sensor outputs. Shear transducers were mounted on the locations of four metatarsal heads and heel in the insole. Sensor outputs were amplified, decorded in the bluetooth transmission part and then transferred to PC. In order to evaluate the developed system, both shear and plantar pressure measurements, synchronized with the three-dimensional motion analysis system, were performed on twelve young healthy male subjects, walking at their comfortable speeds. The maximum peak pressure during gait was 5.00kPa/B.W at the heel. The time when large local shear stresses were acted correlated well with the time of fast COP movements. The anteroposterior shear was dominant near the COP trajectory, but the mediolateral shear was noted away from the COP trajectory. The vector sum of shear stresses revealed a strong correlation with COP movement velocity. The present study will be helpful to select the material and to design of foot orthoses and orthopedic shoes for diabetic neuropathy or Hansen disease.

Role of Attentional Focus in Balance Training: Effects on Ankle Kinematics in Patients with Chronic Ankle Instability during Walking - A Double-Blinded Randomized Control Trial

  • Hyun Sik Chang;Hyung Gyu Jeon;Tae Kyu Kang;Kyeongtak Song;Sae Yong Lee
    • Korean Journal of Applied Biomechanics
    • /
    • v.33 no.2
    • /
    • pp.62-72
    • /
    • 2023
  • Objective: Although balance training has been used as an effective ankle injury rehabilitation program to restore neuromuscular deficits in patients with chronic ankle instability, it is not effectively used in terms of motor learning. Attentional focusing can be an effective method for improving ankle kinematics to prevent recurrent ankle injuries. This study aimed to 1) evaluate the effects of attentional focus, including internal and external focus, and 2) determine a more effective focusing method for patients with chronic ankle instability to learn balance tasks. Method: Twenty-four patients with chronic ankle instability were randomly assigned to three groups (external focus, internal focus, and no feedback) and underwent four weeks of progressive balance training. The three-dimensional ankle kinematics of each patient were measured before and after training as the main outcomes. Ensemble curve analysis, discrete point analysis, and post hoc pairwise comparisons were performed to identify interactions between groups and time. Results: The results showed that (1) the external focus group was more dorsiflexed and everted than the internal focus group; (2) the external focus group was more dorsiflexed than the no feedback group; and (3) the no feedback group was more dorsiflexed than the internal focus group. Conclusion: Because dorsiflexion and eversion are ankle motions that oppose the mechanism of lateral ankle sprain, using the external focus method during balance training may be more effective in modifying these motions, thereby reducing the risk of ankle sprain.

Effects of Hallux Valgus Orthoses on Ground Reaction Force Using 3D Motion Analysis in Individuals With Hallux Valgus Deformity

  • Kim, Yong-wook
    • Physical Therapy Korea
    • /
    • v.27 no.4
    • /
    • pp.227-232
    • /
    • 2020
  • Background: Hallux valgus (HV) is a foot deformity developed by mediolateral deviation of the first metatarsophalangeal joint. Although various foot-toe orthoses were used to correct the HV angle, verification of the effects of kinetics variables such as ground reaction force (GRF) through three-dimensional (3D) gait analysis according to the various type of orthoses for HV is insufficient. Objects: This study aimed to investigate the effect of soft and hard types of foot and toe orthoses to correct HV deformity on the GRF in individuals with HV using 3D motion analysis system during walking. Methods: Twenty-six subjects participated in the experiment. Participants had HV angle of more than 15° in both feet. Two force platforms were used to obtain 3D GRF data for both feet and a 3D motion capture system with six infrared cameras was used to measure exact stance phase point such as heel strike or toe off period. Total walk trials of each participant were 8 to 10, the walkway length was 6 m. Two-way repeated measures ANOVA was used to determine the effects of each orthosis condition on the various GRF values. Results: The late anteroposterior maximal force and a first vertical peak force of the GRF showed that the hard type orthosis condition significantly increased GRF compared to the other orthosis conditions (p < 0.05). Conclusion: There were significant effects in GRF values when wearing the hard type foot orthosis. However, the hard type foot orthosis was uncomfortable to wear during walking. Therefore, it is necessary to develop a new foot-toe orthosis that can compensate for these disadvantages.

Implementation of Motion Analysis System based on Inertial Measurement Units for Rehabilitation Purposes (재활훈련을 위한 관성센서 기반 동작 분석 시스템 구현)

  • Kang, S.I.;Cho, J.S.;Lim, D.H.;Lee, J.S.;Kim, I.Y.
    • Journal of rehabilitation welfare engineering & assistive technology
    • /
    • v.7 no.2
    • /
    • pp.47-54
    • /
    • 2013
  • In this paper, we present an inertial sensor-based motion capturing system to measure and analyze whole body movements. This system implements a wireless AHRS(attitude heading reference system) we developed using a combination of rate gyroscope, accelerometer and magnetometer sensor signals. Several AHRS modules mounted on segments of the patient's body provide the quaternions representing the patient segments's orientation in space. We performed 3D motion capture using the quaternion data calculated. And a method is also proposed for calculating three-dimensional inter-segment joint angle which is an important bio-mechanical measure for a variety of applications related to rehabilitation. To evaluate the performance of our AHRS module, the Vicon motion capture system, which offers millimeter resolution of 3D spatial displacements and orientations, is used as a reference. The evaluation resulted in a RMSE of 2.56 degree. The results suggest that our system will provide an in-depth insight into the effectiveness, appropriate level of care, and feedback of the rehabilitation process by performing real-time limbs or gait analysis during the post-stroke recovery process.

  • PDF

Analysis of Joint Moment in the Intact Limb With Uni-Transfemoral Amputee During Level Walking (편측 대퇴절단자의 보행 시 건측 하지 관절 모멘트 분석)

  • Chang, Yun-Hee;Lee, Wan-Hee
    • Physical Therapy Korea
    • /
    • v.15 no.2
    • /
    • pp.64-72
    • /
    • 2008
  • The purpose of this study was to determine the differences in joint moment in the intact limb of uni-transfemoral amputees and to identify the implications of knee osteoarthritis. As an experimental method, three-dimensional gait analysis was performed on 10 uni-transfemoral amputees and 10 healthy males. Kinematics and kinetics at the hip, knee, and ankle joint were calculated. As a statistical method, independent t-tests were conducted to perform a comparison between the transfemoral amputee group and the control group. The results showed that the external knee adduction moment increased in the transfemoral amputee group (.22 Nm/kg) compared with that of the control group (.13 Nm/kg) at terminal stance (p=.008). External knee flexion moment also increased in the transfemoral amputee group (.24 Nm/kg) but this difference was not statistically significant. External hip flexion moment increased in the transfemoral amputee group (1.35 Nm/kg) compared with that of the control group (.45 Nm/kg) at initial stance, and external hip extension moment decreased in the transfemoral amputee group (-.26 Nm/kg) compared with that of the control group (-.76 Nm/kg) at terminal stance. Although external ankle plantarflexion moment of the transfemoral amputee group increased, it was not found to be statistically significant. The results suggest that the intact limb joint moment of the uni-transfemoral amputees during walking can be different from that of healthy subjects. In conclusion, it was found that there is a link between the increase of external knee adduction moment and the prevalence of knee osteoarthritis in uni-transfemoral amputees. This result is expected to provide some objective data for rehabilitation programs related to knee osteoarthritis in transfemoral amputees.

  • PDF

The Effect of Stair Depth on Ground Reaction Force Parameters - Asymmetric and Variability Indices - (계단보행 시 계단 너비가 지면반력 파라미터에 미치는 영향 -비대칭 지수 및 일관성 지수-)

  • Yoon, Suk-Hoon
    • Korean Journal of Applied Biomechanics
    • /
    • v.18 no.1
    • /
    • pp.169-178
    • /
    • 2008
  • The goals of this study were to provide data of 3 dimensional ground reaction force(GRF) parameters during stair ascent and descent on three different stair runs and to investigate variability and asymmetry index of them. 10 healthy adults participated in this study and performed 7 different types of gait with 10 trials each. After data analysis, following results were found. Firstly, stair run did not affect on the pattern of GRF parameters, coefficient of variation and asymmetry index. Secondly, a significant different GRF pattern was found between level walking and stair walking. Especially, ascending stair walking has only large Fz1 and small Fz3 while level walking and descending stair walking have a "M" shape connected by Fz1, Fz2 and Fz3. Thirdly, only vertical GRF parameters of stair walking revealed acceptable coefficient of variation and asymmetry index.