• 제목/요약/키워드: three-dimensional FEM analysis

검색결과 301건 처리시간 0.031초

A 3-D Steady-State Analysis of Thermal Behavior in EHV GIS Busbar

  • Lei, Jin;Zhong, Jian-ying;Wu, Shi-jin;Wang, Zhen;Guo, Yu-jing;Qin, Xin-yan
    • Journal of Electrical Engineering and Technology
    • /
    • 제11권3호
    • /
    • pp.781-789
    • /
    • 2016
  • Busbar has been used as electric conductor within extra high voltage (EHV) gas insulated switchgear (GIS), which makes EHV GIS higher security, smaller size and lower cost. However, the main fault of GIS is overheating of busbar connection parts, circuit breaker and isolating switch contact parts, which has been already restricting development of GIS to a large extent. In this study, a coupled magneto-flow-thermal analysis is used to investigate the thermal properties of GIS busbar in steady-state. A three-dimensional (3-D) finite element model (FEM) is built to calculate multiphysics fields including electromagnetic field, flow field and thermal field in steady-state. The influences of current on the magnetic flux density, flow velocity and heat distribution has been investigated. Temperature differences of inner wall and outer wall are investigated for busbar tank and conducting rod. Considering the end effect in the busbar, temperature rise difference is compared between end sections and the middle section. In order to obtain better heat dissipation effect, diameters of conductor and tank are optimized based on temperature rise simulation results. Temperature rise tests have been done to validate the 3-D simulation model, which is observed a good correlation with the simulation results. This study provides technical support for optimized structure of the EHV GIS busbar.

새로운 혼합알고리즘을 이용한 CPFS 내에서의 일어나는 동적 열전달의 수식화 및 해석 (Modeling and analysis of dynamic heat transfer in the cable penetration fire stop system by using a new hybrid algorithm)

  • 윤인섭;윤종필;권성필
    • 한국가스학회지
    • /
    • 제7권4호
    • /
    • pp.44-52
    • /
    • 2003
  • 본 논문은 원자력발전소 방화벽에 설치된 케이블관통부 충전시스템(CPFS: Cable penetration fire stop) 안에서 일어나는 동적 열전달 현상을 수식화하고, 새로운 혼합알고리즘을 이용해서 수치적으로 계산하여, 3차원 그래픽으로 나타내는 작업에 관한 연구이다. CPFS 내에서의 열전도 현상을 주어진 초기조건과 경계조건하에서 포물선 편미분방정식(Parabolic PDE)으로 수식화하였다. 계산을 단순화하기 위하여 전체 열 흐름을 z-축직선상에서의 일어나는 열전도 성분과 x-y-좌표 평면상에서 일어나는 열전도 성분으로 나누었다. z-축과 평행한 직선상에서 일어나는 열전도를 나타내는 PDE는 연속과완화법(SOR: Sequential over-relaxation)을 이용하여 유한불연속 점들에 대한 연립상미분방정식(ODE)으로 만들어서 풀었고, x-y-좌표 평면상에서 일어나는 열전도에 관한 PDE는 Galerkin 유한요소법(FEM: Finite element method)을 적용하여 ODE로 전환해서 풀었다. 여기서 시간과 공간의 함수인 온도는 각 직선상의 점들과 각 평면상의 요소절점들에 대해서 일정한 시간간격으로 초기온도와 경계온도를 업데이트하여 번갈아 가며 계산한다. 이러한 일련의 계산결과를 바탕으로 CPFS시스템 내에서의 온도분포의 동적인 변화를 계산해 낼 수 있었다. 결론적으로 관통하는 케이블이 CPFS시스템의 온도분포에 매우 중요한 역할을 한다는 것을 알 수 있었다. 시뮬레이션 결과는 CPFS내의 온도분포를 쉽게 이해할 수 있도록 3차원 그래픽으로 나타냈으며, 관통하는 케이블이 방화시스템의 온도분포에 매우 중요한 영향을 끼친다는 것을 알 수 있었다. 마지막으로 계산결과를 실험결과와 직접 비교함으로써, 개발된 모델과 계산 알고리즘의 정당성을 보였다.

  • PDF

적합도가 다른 임플랜트 지지 보철물의 삼차원적 응력 분석 (Three dimensional stress analysis of implant-supported prosthesis with various misfit)

  • 양홍서;정현주;박영준;박상원
    • 구강회복응용과학지
    • /
    • 제17권4호
    • /
    • pp.307-314
    • /
    • 2001
  • To evaluate the effect of misfit in two implant-supported fixed partial dentures in the posterior of the mandible, variations of the standard finite element models were made by changing the location of the gap as follows: 1) no gap present; 2) located between the gold cylinder and the abutment on the distal implant; 3) gap located between the gold cylinder and the abutment on the mesial implant. The results of this study were as follows: 1. When the location of the gap was close to the load applied on the prosthesis, the stress in the prosthesis, implant components and surrounding bone increased. 2. The presence of cantilever increased the stress in the prosthesis, implant and surrounding bone significantly, regardless of the presence of the gap. 3. When there was a gap between the prosthesis and abutment, the stress in the bone around the implant increased. 4. When passive fit was achieved, the stress was distributed widely in each component with less peak stress in each component. 5. The inner structures of the implant components, the gold screw and the abutment screw bear more stress when the prosthesis did not exhibit passive fit with the abutments than when passive fit was present.

  • PDF

모터의 성능향상을 위한 마그네틱 센서의 3차원 전자장 해석 (3D Electromagnetic Analysis of Magnetic Sensor for Improvement of Motor)

  • 심상오;김기찬
    • 한국산학기술학회논문지
    • /
    • 제14권5호
    • /
    • pp.2381-2387
    • /
    • 2013
  • 본 논문에서는 전동기의 속도 센서로 사용되는 마그네틱 센서의 3차원 전자장 해석 기술 및 분석 방법에 대하여 논하였다. 마그네틱 센서는 레졸버 및 엔코더와 같은 속도센서에 비해 가격이 싸고 활용성이 높은 장점이 있는 반면, 정밀도가 낮으며 외부 자기장에 대하여 간섭을 많이 받는 단점이 존재한다. 마그네틱 센서는 전동기가 회전할 때 사인과 코사인 파형이 발생된다. 그러나 홀 소자 근처에서의 자기적 노이즈로 인하여 사인 및 코사인 신호가 왜곡이 발생하여 각도 오차로 나타난다. 본 논문에서는 마그네틱 센서의 홀 소자의 적절한 위치 선정과 주위에 적절한 요크를 다꾸찌 방법에 의해 최적 설계를 수행하여 이러한 왜곡을 방지하고자 하였다. 해석방법으로는 3차원 유한요소법을 이용하여 해석의 정밀도를 높였다.

우수한 수렴특성을 갖는 3차원 열흐름 방정식의 이산화 방법 (A discretization method of the three dimensional heat flow equation with excellent convergence characteristics)

  • 이은구;윤현민;김철성
    • 전기전자학회논문지
    • /
    • 제6권2호
    • /
    • pp.136-145
    • /
    • 2002
  • 정상상태에서 소자 내부의 격자온도 분포를 해석할 수 있는 시뮬레이터를 개발하였다. Slotboom 변수를 사용하여 열흐름 방정식을 이산화하였고, 요소내에서 열전도율의 적분값을 해석적으로 구할 수 있는 방법을 제안하였다. 제안된 방법의 타당성을 검증하기 위해 $N^+P$ 접합 다이오드와 BJT에 대해 모의실험을 수행하였고 DAVINCI와 MEDICI의 결과와 비교하였다. $N^+P$ 접합 다이오드에서 순방향 인가전압이 1.4[V]일 때 격자 온도분포는 DAVINCI의 결과와 2%의 상대오차를 보였으며 BJT에서 컬렉터 전압이 5.0[V]이고 베이스 전압이 0.5[V]일 때 격자 온도분포는 MEDICI의 결과와 3%의 상대오차를 보였다. BANDIS에서 제안된 열전도율의 적분방법을 사용하는 경우 수렴을 위해 평균 3.45회의 행렬 연산이 필요하나 DAVINCI에서는 평균 5.1회의 행렬 연산이 필요하였고 MEDICI는 평균 4.3회 행렬연산이 필요하였다.

  • PDF

사질토 지반에서 Shell 기초 거동에 대한 연구 (A Study on Shell Foundation Behaviour in Cohesionless Soil)

  • 김상환;이충환;최충식
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2008년도 춘계 학술발표회 초청강연 및 논문집
    • /
    • pp.1144-1154
    • /
    • 2008
  • In this paper, the behaviour of shell foundation was studied. In order to perform this study, three studies such as theoretical, numerical and experimental programs were performed. In the theoretical program, the general shallow foundation theories and failure mechanism developed by Terzaghi, Mayerhof and others were reviewed and compared. Based on the previous shallow foundation behaviour, the shell foundation theory was developed using the upper boundary theorem. In the numerical study, the 2 and 3 dimensional FEM simulations were carried out using an uncoupled-analysis approach. From the analysis results, the adequate depth of shell foundation was evaluated. It was also evaluated the bearing capacity according to the shell angle ($120^{\circ}$, $90^{\circ}$, $60^{\circ}$). In the experimental study, the laboratory model tests were carried out for five cases of different foundation shapes including the rectangular and circular foundation in order to verify the theoretical and nemerical study. According to the results of this study, the bearing capacity of shell foundation was theoretically about 15% larger than that of general foundation. However, in the model test, the bearing capacity of shell foundation was about 25 to 30% larger than that of general foundation. In the case of shell angle, the maximum bearing capacity of shell foundation shows when the shell angle of foundation was $60^{\circ}$. In addition, Even if the shell foundation has the various advantages compared with the general foundations as described above, the practical verifications in full scale size will be necessary to use in the field and will be helpful in the technical development of other special foundations.

  • PDF

3D numerical analysis of piled raft foundation for Ho Chi Minh City subsoil conditions

  • Amornfa, Kamol;Quang, Ha T.;Tuan, Tran V.
    • Geomechanics and Engineering
    • /
    • 제29권2호
    • /
    • pp.183-192
    • /
    • 2022
  • Piled raft foundations are widely used and effective in supporting high-rise buildings around the world. In this study, a piled raft system was numerically simulated using PLAXIS 3D. The settlement comparison results between the actual building measurements and the three-dimensional (3D) numerical analysis, were in good agreement, indicating the usefulness of this approach for the evaluation of the feasibility of using a piled raft foundation in Ho Chi Minh City subsoil. The effects were investigated of the number of piles based on pile spacing, pile length, raft embedment on the settlement, load sharing, bending moments, and the shear force of the piled raft foundation in Ho Chi Minh City subsoil. The results indicated that with an increased number of piles, increased pile length, and embedding raft depth, the total and differential settlement decreased. The optimal design consisted of pile numbers of 60-70, corresponding to pile spacings is 5.5-6 times the pile diameter (Dp), in conjunction with a pile length-to-pile diameter ratio of 30. Furthermore, load sharing by the raft, by locating it in the second layer of stiff clay, could achieve 66% of the building load. The proposed model of piled raft foundations could reduce the total foundation cost by 49.61% compared to the conventional design. This research can assist practicing engineers in selecting pile and raft parameters in the design of piled raft foundations to produce an economical design for high-rise buildings in Ho Chi Minh City, Viet Nam, and around the world.

Three-dimensional numerical analysis of nonlinear phenomena of the tensile resistance of suction caissons

  • Azam, Arefi;Pooria, Ahad;Mehdi, Bayat;Mohammad, Silani
    • Geomechanics and Engineering
    • /
    • 제32권3호
    • /
    • pp.255-270
    • /
    • 2023
  • One of the main parameters that affect the design of suction caisson-supported offshore structures is uplift behavior. Pull-out of suction caissons is profoundly utilized as the offshore wind turbine foundations accompany by a tensile resistance that is a function of a complex interaction between the caisson dimensions, geometry, wall roughness, soil type, load history, pull-out rate, and many other parameters. In this paper, a parametric study using a 3-D finite element model (FEM) of a single offshore suction caisson (SOSC) surrounded by saturated soil is performed to examine the effect of some key factors on the tensile resistance of the suction bucket foundation. Among the aforementioned parameters, caisson geometry and uplift loading as well as the difference between the tensile resistance and suction pressure on the behavior of the soil-foundation system including tensile capacity are investigated. For this purpose, a full model including 3-D suction caisson, soil, and soil-structure interaction (SSI) is developed in Abaqus based on the u-p formulation accounting for soil displacement (u) and pore pressure, P.The dynamic responses of foundations are compared and validated with the known results from the literature. The paper has focused on the effect of geometry change of 3-D SOSC to present the soil-structure interaction and the tensile capacity. Different 3-D caisson models such as triangular, pentagonal, hexagonal, and octagonal are employed. It is observed that regardless of the caisson geometry, by increasing the uplift loading rate, the tensile resistance increases. More specifically, it is found that the resistance to pull-out of the cylinder is higher than the other geometries and this geometry is the optimum one for designing caissons.

수치해석을 이용한 말뚝이 결합된 블록식방파제의 수평저항력에 관한 연구 (A Study of Lateral Resistance of Block Breakwater Combined with Piles)

  • 이원효;권순구;김태형
    • 한국해안·해양공학회논문집
    • /
    • 제34권4호
    • /
    • pp.100-108
    • /
    • 2022
  • 본 연구는 말뚝이 결합된 블록식방파제에 대하여 수평하중 재하에 따른 블록과 말뚝의 거동을 파악하기 위하여 FEM 3차원 수치해석을 실시하였다. 지반구성모델은 Mohr-Coulomb 모델을 향상시킨 Modified Mohr Coulomb 모델을 적용하였다. 말뚝이 블록에만 관입된 경우, 사석층(H = 4.29 cm)까지 근입된 경우, 원지반속에 근입된 2H, 3H, 4H의 경우에 검토하였다. 실내모형실험 결과와 수치해석를 비교한 결과, 수평저항력-변위가 서로 유사한 거동을 보이는 것으로 나타났다. 말뚝의 근입깊이가 1H~ 2H까지는 말뚝이 회전거동을 보이고, 3H~4H의 경우에는 휨거동 양상을 보이는 것으로 해석되었다. 말뚝의 근입깊이가 3H 이상인 경우에는 말뚝이 휨거동을 보이므로 말뚝이 블록식방파제의 수평저항력에 크게 기여한다고 볼 수 있다. 본 연구 결과는 실제 크기 구조물 설계를 위한 다양한 수치해석 시 자료로 활용이 있을 것이다.

3차원 유한요소 모형를 이용한 줄눈 콘크리트포장 하중전달의 민감도 분석 (Sensitivity Analysis of Load Trunsfer of Jointed Concrete Pavements Using 3-D Finite Element Model)

  • 썬런쥬안;임진선;정진훈
    • 한국도로학회논문집
    • /
    • 제10권2호
    • /
    • pp.145-157
    • /
    • 2008
  • 하중전달효율은 다웰이 설치되었거나 설치되지 않은 콘크리트포장 줄눈의 구조적 성능을 나타내기 위해 사용된다. ABAQUS 소프트웨어를 사용한 줄눈 콘크리트장의 3차원 모형이 본 연구를 통하여 구축되었다. 기층과 노상이 접착되어 구성된 하부층 위에 3개의 슬래브가 놓였으며, 스프링 요소를 사용하여 인접한 슬래브를 줄눈에서 연결하였다. 콘크리트포장의 다양한 줄눈강성을 모사하기 위하여 다양한 값의 스프링 상수를 입력값으로 사용하여 그 관계를 조사하였으며, 스프링 상수가 커질수록 줄눈의 하중전달효율이 증가하는 것으로 나타났다. 슬래브와 기증의 다양한 탄성계수와 두께를 사용하여 슬래브의 거동과 하중전달효율에 미치는 재료물성과 기하학적 형상의 영향을 분석하였다. 그 결과 노상의 탄성계수는 기층의 탄성계수와 슬래브 및 기층의 두께보다 더 큰 영향을 미치는 것으로 나타났다. 또한 양 또는 영의 온도구배에서보다는 음의 온도구배에서 슬래브의 거동과 하중 전단효율이 더 민감 하게 변화하였으며, 낮은 강성의 줄눈은 슬래브의 온도구배에 더 민감한 것으로 나타났다.

  • PDF