• 제목/요약/키워드: three phase flow

검색결과 591건 처리시간 0.026초

공조 시스템 내의 분배기 출구관의 삽입깊이에 따른 유량분포연구 (A Numerical Study on Refrigerant Distribution according to the Insertion Depth of the Distributor-Outlet Pipes in an Air-Conditioning System)

  • 이희원;박일석
    • 설비공학논문집
    • /
    • 제27권9호
    • /
    • pp.491-496
    • /
    • 2015
  • Generally, the phase of the refrigerants that circulate in air-conditioning systems is repeatedly changed from liquid to gas and from gas to liquid. In vapor-compression refrigeration, the refrigerant at the inlet of the evaporator is in a gas-liquid two-phase state; therefore, to enhance the heat-transfer performance of the evaporator, the even distribution of the refrigerant across multiple passages of the evaporator is essential. Unlike the distribution of a single-phase refrigerant, multi-phase distribution requires further considerations. It is known that the multi-phase distribution at the outlet of the distributor is affected by factors such as the operating condition, the distributor's shape, and the insertion depth of the outlet pipes; here, the insertion depth of the outlet pipes is especially significant. In this study, for a cylindrical distributor with a 90-degree bend entrance and three outlet pipes, the flow uniformity at the outlet pipes was numerically tested in relation to variations of the insertion depth of the outlet pipes.

LES 해석에서 액체제트의 분열에 대한 확률론적 분열 모델링 비교 (Stochastic Model Comparison for the Breakup and Atomization of a Liquid Jet using LES)

  • 유영린;성홍계
    • 한국항공우주학회지
    • /
    • 제45권6호
    • /
    • pp.447-454
    • /
    • 2017
  • 난류 유동장으로 분사되는 두가지 형태의 액체 제트 (수평분사는 디젤연료와 수직분사는 물)의 액주 분열과 미립화 현상에 관한 이상(Two-phase) 유동에 대해 3차원 LES 수치해석을 수행하였다. 기체상태의 공기 유동은 오일러리안 해법을 사용하고, 액체 제트의 액적 추적은 라그랑지안 해법을 사용하여 기체-액체간 이상유동 해석을 수행하였다. 두 종류의 확률론적 분열 모델(Stochastic breakup model)을 사용하여 액적 분열을 모사하였으며, 액체제트의 침투깊이와 액적 분포(Sauter Mean Diameter)를 실험결과와 비교하여 미세하게 분열되는 액체 제트의 분열 현상에 대해 확률론적 분열 모델링의 적합성을 제시하였다.

Analysis of Blood Flow Interacted with Leaflets in MHV in View of Fluid-Structure Interaction

  • Park, Choeng-Ryul;Kim, Chang-Nyung
    • Journal of Mechanical Science and Technology
    • /
    • 제15권5호
    • /
    • pp.613-622
    • /
    • 2001
  • Interaction of blood flow and leaflet behavior in a bileaflet mechanical heart valve was investigated using computational analysis. Blood flows of a Newtonian fluid and a non-Newtonian fluid with Carreau model were modeled as pulsatile, laminar, and incompressible. A finite volume computational fluid dynamics code and a finite element structure dynamics code were used concurrently to solve the flow and structure equations, respectively, where the two equations were strongly coupled. Physiologic ventricular and aortic pressure waveforms were used as flow boundary conditions. Flow fields, leaflet behaviors, and shear stresses with time were obtained for Newtonian and non-Newtonian fluid cases. At the fully opened phase three jets through the leaflets were found and large vortices were present in the sinus area. At the very final stage of the closing phase, the angular velocity of the leaflet was enormously large. Large shear stress was found on leaflet tips and in the orifice region between two leaflets at the final stage of closing phase. This method using fluid-structure interaction turned out to be a useful tool to analyze the different designs of existing and future bileaflet valves.

  • PDF

Numerical study on thermal-hydraulics of external reactor vessel cooling in high-power reactor using MARS-KS1.5 code: CFD-aided estimation of natural circulation flow rate

  • Song, Min Seop;Park, Il Woong;Kim, Eung Soo;Lee, Yeon-Gun
    • Nuclear Engineering and Technology
    • /
    • 제54권1호
    • /
    • pp.72-83
    • /
    • 2022
  • This paper presents a numerical investigation of two-phase natural circulation flows established when external reactor vessel cooling is applied to a severe accident of the APR1400 reactor for the in-vessel retention of the core melt. The coolability limit due to external reactor vessel cooling is associated with the natural circulation flow rate around the lower head of the reactor vessel. For an elaborate prediction of the natural circulation flow rate using a thermal-hydraulic system code, MARS-KS1.5, a three-dimensional computational fluid dynamics (CFD) simulation is conducted to estimate the flow rate and pressure distribution of a liquid-state coolant at the brink of significant void generation. The CFD calculation results are used to determine the loss coefficient at major flow junctions, where substantial pressure losses are expected, in the nodalization scheme of the MARS-KS code such that the single-phase flow rate is the same as that predicted via CFD simulations. Subsequently, the MARS-KS analysis is performed for the two-phase natural circulation regime, and the transient behavior of the main thermal-hydraulic variables is investigated.

유입 방향에 따른 알루미늄 평행류 열교환기 헤더내 공기-물 2 상류 분지 실험 (Air-water two-phase distribution in an aluminum parallel flow heat exchanger header having different inlet orientations)

  • 김내현;함정호;박태균;김도영
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2007년도 춘계학술대회B
    • /
    • pp.2108-2112
    • /
    • 2007
  • The air and water flow distribution are experimentally studied for a round header-ten microchannel tube configuration. Three different inlet orientations (parallel, side, normal) were investigated. Tests were conducted with downward flow configuration for the mass flux from 70 to 130 kg/$m^2s$, quality from 0.2 to 0.6, non-dimensional protrusion depth (h/D) from 0.0 to 0.5. It is shown that, for almost all the test conditions, normal inlet yielded the best flow distribution, followed by side and parallel inlet. Possible reasoning is provided using flow visualization results.

  • PDF

CIP 방법을 사용한 해석법 (A NUMERICAL ANALYSIS USING CIP METHOD)

  • 이정희;허남건
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2009년 추계학술대회논문집
    • /
    • pp.211-217
    • /
    • 2009
  • The numerical program has been developed for the purpose of the complicate geometries application using CIP method. The non-staggered, non-orthogonal, and unstructured grid system can be also used for the various geometries in the program. For validating CIP solver, the lid-driven cavity flow and solitary wave propagation flow are carried out. Test results show a good agreement with the verified results. The dynamic solver was used for the behavior of moving body. Interface process between the two solvers is introduced. The research was performed on the flow problem around torpedo and log and the flow problem in a tank in order to analyze the three phase flow problem Although the comparison to the verified results was not quantitatively performed, the trend of the results was reasonable.

  • PDF

축류송풍기의 실속셀 거동에 관한 실험적 연구 (Experimental Study on the Behavior of Stall Cell in an Axial Flow Fan)

  • 신유환;김광호;강창식
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2002년도 학술대회지
    • /
    • pp.643-646
    • /
    • 2002
  • Experimental study was conducted to reveal the flow mechanism under rotating stall in an axial flow fan. For this study unsteady pressure was measured using high frequency pressure transducers mounted on the casing wall of rotor passage and total pressure fields were measured at the rotor upstream and downstream. The measured pressure signal was analyzed by Wavelet Transform and Double Phase Locked Averaging Technique. From the result of unsteady pressure field of the casing wall, one period of rotating stall was divided into three zones and the flow characteristics on each zone were described in detail. The pressure field was also analyzed in terms of the pressure distribution along pressure side and suction side of blade tip. From the result of total pressure fields at inlet and outlet of the rotor, the useful information on the characteristics of the stall cell in radial direction was provided.

  • PDF

3상 PWM AC/AC Buck 컨버터를 사용한 3상 전압 위상천이기 (Three Phase Voltage Phase Shifter Using Three Phase PWM AC/AC Buck Converter)

  • 최남섭
    • 한국정보통신학회논문지
    • /
    • 제5권6호
    • /
    • pp.1116-1121
    • /
    • 2001
  • 전력의 흐름제어와 전원시스템의 과도안정성 개선을 위하여 전압의 위상을 제어할 필요성이 있는 경우가 있다. 이제까지 위상 천이기는 주로 상변압기와 사이리스터 탭변환기를 사용하여 구성하였는데, 이는 응답속응성이 느리고 제어안정성이 떨어지는 단점이 있다. 본 논문에서는 PWM AC/AC 컨버터를 사용한 3상 전압 위상천이기를 제안한다. 제안된 3상 전압 위상천이기는 PWM제어에 의하여 응답속응성이 우수하고 과도상태에서의 제어안정성을 개선시킬 수 있는 장점이 있다. 본 논문에서는 제안된 시스템의 회로구성, 동작원리와 특성 등을 설명하여 그 특징과 장단점을 나타내고, 이를 PSIM 컴퓨터 시뮬레이션을 통하여 동작과 해석의 타당성을 확인한다.

  • PDF

사출성형에서의 비등온, 3차원 유동해서과 그 응용 (Flow analysis of non-isothermal three dimensional filling phase in injection molding and its application)

  • 김대업;정근섭;이귀영
    • 오토저널
    • /
    • 제15권1호
    • /
    • pp.17-24
    • /
    • 1993
  • 사출성형 문제는 열전달과 유체유동이 복합된 문제라고 할수 있다. 사출성형 공정은 충진(filling), 보압(packing) 및 냉각과정(cooling phase)으로 이루어 진다. 충진과정은 높은 점성의 Non-Newtonian유체가 몰드내의 캐버티로 사출됨으로써 이루어지며 플라스틱의 점성도는 플라스틱의 온도 및 유동속도와 관련이 크며 이 flow-rate는 점도와 더불어 변화한다. CAE 유동해석 프로그램은 유체의 흐름과 열전달을 이용하여 충진과정을 이해하는데 이용되고 있다. 본 고에서는 사출성형 과정 중 충진과정에 대한 컴퓨터 시뮬레이션과 그 적용사례에 대하여 살펴본다.

  • PDF

CUPID 코드를 활용한 2×2 봉다발 부수로 유동 해석 (ASSESSMENT OF THE CUPIDCODE APPLICABILITY TO SUBCHANNEL FLOW IN 2×2 ROD BUNDLE)

  • 이재룡;박익규;김정우
    • 한국전산유체공학회지
    • /
    • 제21권4호
    • /
    • pp.71-77
    • /
    • 2016
  • The CUPID code is a transient, three-dimensional, two-fluid, thermal-hydraulic code designed for a component-scale analysis of nuclear reactor components. The primary objective of this study is to assess the applicability of CUPID to single-phase turbulent flow analyses of $2{\times}2$ rod bundle subchannel. The bulk velocity at the inlet varies from 1.0 m/s up to 2.0 m/s which is equivalent to the fully turbulent flow with the range of Re=12,500 to 25,000. Adiabatic single-phase flow is assumed. The velocity profile at the exit region is quantitatively compared with both experimental measurement and commercial CFD tool. Three different boundary conditions are simulated and quantitatively compared each other. The calculation results of CUPID code shows a good agreement with the experimental data. It is concluded that the CUPID code has capability to reproduce the turbulent flow behavior for the $2{\times}2$ rod bundle geometry.