• Title/Summary/Keyword: thread engagement

Search Result 5, Processing Time 0.022 seconds

Experimental study on stripping mechanism of tension controlled bolts (TC볼트의 스트리핑 메카니즘에 대한 실험적 연구)

  • 신근하
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.9 no.1
    • /
    • pp.111-118
    • /
    • 2000
  • Over tightening experiments of the tension-controlled bolts are carried out and the stripping mechanism is reviewed base on the observed results. There are two modes of bolt failure due to the over tightening : one the fracture of the bolt the other the thread stripping Bifurcation between these two modes is rather delicate but it seems being related with the elastic flexibility of the bolt which depends upon the unused thread length. The fracture mode occurs in the bolts with good flexibility while the latter with bad one. According to the ISO Standard some meter coarse threads like M20 and M22 have the same pitch which causes bigger fastener to less resistance in shear and bending compared with the smaller one. however since UNC thread system adapts different pitch for different nominal diameter unified coarse threads show better stripping resistance than their corresponding meter threads.

  • PDF

The effect of various thread designs on the initial stability of taper implants

  • Park, Ju-Hee;Lim, Young-Jun;Kim, Myung-Joo;Kwon, Ho-Beom
    • The Journal of Advanced Prosthodontics
    • /
    • v.1 no.1
    • /
    • pp.19-25
    • /
    • 2009
  • STATEMENT OF PROBLEM. Primary stability at the time of implant placement is related to the level of primary bone contact. The level of bone contact with implant is affected by thread design, surgical procedure and bone quality, etc. PURPOSE. The aim of this study was to compare the initial stability of the various taper implants according to the thread designs, half of which were engaged to inferior cortical wall of type IV bone(Group 1) and the rest of which were not engaged to inferior cortical wall(Group 2) by measuring the implant stability quotient(ISQ) and the removal torque value(RTV). MATERIAL AND METHODS. In this study, 6 different implant fixtures with 10 mm length were installed. In order to simulate the sinus inferior wall of type IV bone, one side cortical bone of swine rib was removed. 6 different implants were installed in the same bone block following manufacturer s recommended procedures. Total 10 bone blocks were made for each group. The height of Group 1 bone block was 10 mm for engagement and that of group 2 was 13 mm. The initial stability was measured with ISQ value using Osstell $mentor^{(R)}$ and with removal torque using MGT50 torque gauge. RESULTS. In this study, we found the following results. 1. In Group 1 with fixtures engaged to the inferior cortical wall, there was no significant difference in RTV and ISQ value among the 6 types of implants. 2. In Group 2 with fixtures not engaged to the inferior cortical wall, there was significant difference in RTV and ISQ value among the 6 types of implants(P < .05). 3. There was significant difference in RTV and ISQ value according to whether fixtures were engaged to the inferior cortical wall or not(P < .05). 4. Under-drilling made RTV and ISQ value increase significantly in the NT implants which had lower RTV and ISQ value in Group 2(P < .05). CONCLUSIONS. Without being engaged to the inferior cortical wall fixtures had initial stability affected by implant types. Also in poor quality bone, under-drilling improved initial stability.

A Study of Teens' Social Media Engagement: Focusing on the Comments for YouTube Beauty Videos (청소년의 소셜 미디어 참여에 관한 연구 - 유튜브 메이크업 영상의 댓글 창을 중심으로 -)

  • Lim, Yeojoo
    • Journal of the Korean BIBLIA Society for library and Information Science
    • /
    • v.32 no.1
    • /
    • pp.415-442
    • /
    • 2021
  • This study analyzed YouTube beauty videos that focus on makeup for teens, based on the assumption that the main viewers of the videos are teens. Through looking at the interaction between beauty information providers and receivers, communication among information receivers, and the way people participate in comment thread, the study examined how teens engage in social media. Many teens who posted comments on YouTube beauty videos praised and envied the beauty of beauty gurus, and tried to connect with them. The comment thread shows that teens answered to each other's questions on makeup tips, shared thoughts and experiences on issues around teen wearing makeup, which helped them build a sense of community, and broaden their views on the way of life. Also observed was power dynamics among youth, such as lecturing or verbal abuse against children and pre-teens by older teens.

Durability Improvement of Engine Bulkhead by Adjusting Design Parameters (설계인자변화에 따른 엔진 벌크헤드 내구성 향상)

  • Yang, Chull-Ho;Han, Moon-Sik
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.19 no.2
    • /
    • pp.111-116
    • /
    • 2011
  • Three-dimensional finite element analyses have been performed to improve the durability of bulkhead. To keep pace with design changes and concentrate on regions of interest, SUBMODEL technique in ABAQUS was used for analysis. An analysis was conducted with following load cases: 1) Cap press-fit, 2) Bearing crush, 3) Bolt assembly, 4) Hot assembly, 5) Firing load, 6) Alternating firing load, 7) 2nd hot assembly. Fatigue analysis was done using commercial software FEMFAT and fatigue factors at the interested regions such as bolt tip area, counter bore, breathing hole, honing clearance were calculated and compared to aid design validation. Finite element modeling in the area of thread engagement used a simple constraint equations. Increasing bolt length, to a minimum of 39 mm above joint face gives a better fatigue resistance to the bulkhead. Breathing hole helps not only circulate the air in the crankcase but also fatigue resistance of bulkhead by relieving the stress at the critical locations.

Surface characteristics and biocompatibility of bioinert nitrides ion plated titanium implant (생불활성 질화물 이온도금된 티타늄 임프란트의 표면특성 및 생체적합성)

  • Chang, Kap-Sung;Kim, Heung-Joong;Park, Joo-Cheol;Kim, Byung-Ock;Han, Kyung-Yoon
    • Journal of Periodontal and Implant Science
    • /
    • v.29 no.1
    • /
    • pp.209-231
    • /
    • 1999
  • Even though titanium(Ti) and its alloys are the most used dental implant materials, there are some problems that Ti wears easily and interferes normal osteogenesis due to the metal ions. Ti coated with bioactive ceramics such as hydroxyapatite has also such problems as the exfoliation or resorption of the coated layer, Recent studies on implant materials have been proceeding to improve physical properties of the implant substrate and biocompatibility of the implant surfaces. The purpose of the present study was to examine the physical property and bone tissue compatibility of bioinert nitrides ion plated Ti, Button type specimens(14mm in diameter, 2.32rrun in height) for the abrasion test and cytotoxicity test and thread type implants(3.75mm in diameter, 6mm in length) for the animal experiments were made from Ti(grade 2) and 316LVM stainless steel. Ti specimens were ion plated with TiN, ZrN by the low temperature arc vapor deposition, and the depth profile of the TiN/Ti, ZrN/Ti ion plated surface was examined by Auger Electron Spectroscopy. Three kind of button type specimens .of TiN/Ti, ZrN/Ti and Ti were used for abrasion test, and HEPAlClC7 cells and CCD cells were cultivated for 4 days with the specimens for cytotoxicity test. Thread type implants of TiN/Ti, ZrN/Ti, Ti, 316LVM were implanted on the femur of 6 adult dogs weighing 10kg-13kg. Two dogs were sacrified for histological examination after 45 days and 90 days, and four dogs were sacrified for the removal torque test of the implant') after 90 days. The removal torque force was measured by Autograph (Shimadzu Co., AGS-1000D series, Japan). Abrasion resistance of TiN/Ti was the highest, and that of ZrN/Ti and Ti were followed. The bioinert nitride ion plated Ti had much better abrasion resistance, compared with Ti, In the cytotoxicity test, the number of both cells were increased in all specimens, and there were no significant difference in cytotoxic reaction among all groups (p>0.1), In histological examination, 316LVM showed the soft tissue engagement in interface between the implant and bone, but the other materials after 45 days noted immature new bone formation in the medullary portion along the implant surface, and those after 90 days showed implant support by new bone formation in both the cortical and the medullary portion, The removal torque force of Tilv/Ti showed significantly higher than that of Ti(p(O,05). The difference in removal torque force between TiN/Ti and ZrN/Ti was not significant(p>0.05), and that of 316LVM was lowest among all groups(p<0.05). These results suggest that bioinert nitrides ion plated Ti can resolve the existing problems of Ti and bioactive ceramics, and it may be clinically applicable to human.

  • PDF