• 제목/요약/키워드: thoracic radiography

검색결과 176건 처리시간 0.025초

Long Term Management of Congenital Ventricular Tachyarrhythmia in a Dog

  • Lee, Geonyoung;Kang, Jooyeon;Ko, Minho;Cho, Hyunkee;Choi, Sooyoung;Park, In-Chul;Chung, Jin-Young
    • 한국임상수의학회지
    • /
    • 제34권5호
    • /
    • pp.353-355
    • /
    • 2017
  • A four month old, intact female Jindo dog presented to the Veterinary Teaching Hospital of Kangwon National University with collapse. Physical examination revealed a heart rate of more than 200 beats per minute. Blood tests showed mild anemia and mild neutrophilia, while thoracic radiography and ultrasonography revealed no remarkable findings. Electrocardiography showed ventricular premature complexes (VPCs). The dog was diagnosed with congenital ventricular tachyarrhythmia. The condition was improved by lidocaine infusion. After 10 days, the dog was discharged from the hospital with a prescription of atenolol, pimobendan, diltiazem, furosemide, spironolactone, and L-carnitine. This dog is still alive after 31 months. However, progressive cardiac remodeling was confirmed on radiography and ultrasonography. Congenital ventricular tachyarrhythmia is rare in dogs, and the prognosis of reported cases is poor. This report describes the long-term successful management of a dog with congenital ventricular tachyarrhythmia.

간엽유착과 담낭염을 동반한 선천성 복막심낭 횡격막 허니아의 효과적 수술처치 (Surgical Correction of Congenital Peritoneopericardial Diaphragmatic Hernia with Adhered Hepatic Lobes and Cholecystitis)

  • 남현숙;곽호현;이세호;박경미;박인철;한정희;우흥명
    • 한국임상수의학회지
    • /
    • 제29권1호
    • /
    • pp.87-92
    • /
    • 2012
  • A six months old, male Shih Tzu dog was referred to the Veterinary Medical Teaching Hospital at Kangwon National University, for lethargy, respiratory embarrassment. Survey radiography revealed enlarged cardiac silhouette due to displacement of gas-filled intestine in the pericardium. Although there were no specific clinical signs, this case was diagnosed as peritoneopericardial diaphragmatic hernia (PPDH) based on the results of positive contrast radiography and thoracic ultrasonograpic findings. In addition, the thickened gall bladder wall observed in ultrasonography, increase of alkaline phosphatase and neutrophils indicated cholecystitis. Two hepatic lobes and gall bladder were severely necrotized and adhere to the diaphragm. Direct reduction of the herniated organs might cause hepatic hemorrhage and bile juice leakage which may induce very poor prognosis. To solve the problems, the adhered organs were dissected with part of diaphragm, and lobectomy with cholecystectomy was performed for prevention of some possible complications including peritonitis. This is case report describing resection of part of diaphragm adhered to herniated organ reduce the risk of possible hepatic hemorrhage during surgical correction of PPDH followed bycholecystectomy and lobectomy.

선천성 횡격막 헤르니아로 오인된 좌측 횡격막 내장탈출 2예 (Left Diaphragmatic Eventration Diagnosed as Congenital Diaphragmatic Hernia by Prenatal Sonography)

  • 염정숙;박지숙;박은실;서지현;임재영;박찬후;우향옥;정은정;조재민;윤희상
    • Pediatric Gastroenterology, Hepatology & Nutrition
    • /
    • 제9권1호
    • /
    • pp.92-97
    • /
    • 2006
  • 선천성 횡격막 내장탈출은 드문 질환으로 산전 초음파로 횡격막 헤르니아와 감별하는 것은 쉽지 않다. 선천성 횡격막 내장탈출과 횡격막 헤르니아의 예후가 다르고 수술적 접근 방식이 다를 수 있어 정확한 감별 진단이 필요하다. 저자들은 산전 초음파 검사에서 선천성 횡격막 헤르니아로 진단되었으나 수술 시에 선천성 횡격막 내장탈출로 진단된 두 증례의 후향적 분석을 통하여 비록 출생 직후의 단순 흉부 사진으로는 두 질환의 감별 진단이 어려웠으나 연속적인 단순흉부사진에서 뚜렷하게 드러나는 병변 측 횡격막을 확인하는 경험을 하였다. 따라서 산전 초음파 검사에서 횡격막 헤르니아로 진단되었다 하더라도 출생 이후에 촬영한 연속적인 단순흉부사진의 주의 깊은 판독을 통한 재평가를 강조하고자 한다.

  • PDF

일반 방사선검사의 소요 시간 실태조사 (Investigation of the Time Required for General Radiography)

  • 임우택;주영철;김연민
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제45권3호
    • /
    • pp.255-262
    • /
    • 2022
  • In this study, by analyzing the examination time for each procedure, the appropriate workload of radiologic technologist is analyzed based on the actual examination time in the current clinical setting by comparing with the examination time in the radiology field setting of the health insurance review and assessment service. In addition, this result is introduced into the calculation of relate value units; it was attempted to provide accurate and objective evidence in the field of radiology. From May 2020 to December 2021, the study retrospectively investigated the examination times recorded in the electronic medical record and picture archiving and communication system at 5 tertiary general hospitals and 1 general hospital. The total of 16 examination parts are applied in this study, including the head, sinuses, chest, ribs, abdomen, pelvis, cervical, thoracic, lumbar, shoulder, elbow, wrist, hip, femur, knee, and ankle. The minimum number of images that could be obtained per radiation generator was 3.6 images for one hour, and the maximum was 6.4 images. When 50% median of procedure time is calculated, the minimum number of images that could be obtained was 16.7 images and maximum was 35.3 images; in addition, minimum examination time is 1.7 minutes, and maximum time is 3.6 minutes. In conclusion, it is judged that there will be insufficient explanation time for basic infection instructions such as hand hygiene during the examinations in current clinical practice. It is believed that radiologic technologists will contribute to providing higher-quality of radiation examination services to the public by complying with guidelines for work and setting appropriate workload on their own.

Chest Radiography of Tuberculosis: Determination of Activity Using Deep Learning Algorithm

  • Ye Ra Choi;Soon Ho Yoon;Jihang Kim;Jin Young Yoo;Hwiyoung Kim;Kwang Nam Jin
    • Tuberculosis and Respiratory Diseases
    • /
    • 제86권3호
    • /
    • pp.226-233
    • /
    • 2023
  • Background: Inactive or old, healed tuberculosis (TB) on chest radiograph (CR) is often found in high TB incidence countries, and to avoid unnecessary evaluation and medication, differentiation from active TB is important. This study develops a deep learning (DL) model to estimate activity in a single chest radiographic analysis. Methods: A total of 3,824 active TB CRs from 511 individuals and 2,277 inactive TB CRs from 558 individuals were retrospectively collected. A pretrained convolutional neural network was fine-tuned to classify active and inactive TB. The model was pretrained with 8,964 pneumonia and 8,525 normal cases from the National Institute of Health (NIH) dataset. During the pretraining phase, the DL model learns the following tasks: pneumonia vs. normal, pneumonia vs. active TB, and active TB vs. normal. The performance of the DL model was validated using three external datasets. Receiver operating characteristic analyses were performed to evaluate the diagnostic performance to determine active TB by DL model and radiologists. Sensitivities and specificities for determining active TB were evaluated for both the DL model and radiologists. Results: The performance of the DL model showed area under the curve (AUC) values of 0.980 in internal validation, and 0.815 and 0.887 in external validation. The AUC values for the DL model, thoracic radiologist, and general radiologist, evaluated using one of the external validation datasets, were 0.815, 0.871, and 0.811, respectively. Conclusion: This DL-based algorithm showed potential as an effective diagnostic tool to identify TB activity, and could be useful for the follow-up of patients with inactive TB in high TB burden countries.

Assessment of radiographic left atrial dimension and C-reactive protein in dogs with myxomatous mitral valve disease

  • Jihee Hong;Han-Joon Lee;Dong-Kwan Lee;Kun-Ho Song
    • 한국동물위생학회지
    • /
    • 제47권1호
    • /
    • pp.1-7
    • /
    • 2024
  • Radiographic left atrial dimension (RLAD) is a valuable metric for assessing left atrial enlargement in dogs. While there have been studies on the use of RLAD and the increase in C-reactive protein (CRP) levels based on heart disease stages, there has been no prior research on the correlation between RLAD and CRP. In this study, the objective was to investigate the relationship between the rise in RLAD as myxomatous mitral valve disease (MMVD) stages advance and the increase in CRP levels with MMVD stage progression. In this study, a total of 30 small-breed dogs were included as subjects. These dogs were diagnosed with MMVD at the American College of Veterinary Internal Medicine (ACVIM) stage B1 or B2, or stage C, based on a comprehensive assessment including physical examination, thoracic radiography, and echocardiography. Measurements of VHS and RLAD were compared to assess any significant differences. There were significant differences in RLAD between dogs with MMVD ACVIM stage B1 and those with stage C. The monocytes and CRP levels showed significant differences between ACVIM stage B1, B2 and ACVIM C. Additionally, a significant correlation was observed between the RLAD and VHS measurements. This underscores the notable association between MMVD stage advancement and elevated monocyte and CRP levels. The RLAD scores exhibited a significant difference among dogs with ACVIM stages B1, B2, and C, and significant variations were also observed in monocyte and CRP levels. These results suggest that monocyte and CRP levels may be a valuable diagnostic indicator for heart disease in dogs during the diagnostic evaluation.

Chest Radiographic and CT Findings of the 2019 Novel Coronavirus Disease (COVID-19): Analysis of Nine Patients Treated in Korea

  • Soon Ho Yoon;Kyung Hee Lee;Jin Yong Kim;Young Kyung Lee;Hongseok Ko;Ki Hwan Kim;Chang Min Park;Yun-Hyeon Kim
    • Korean Journal of Radiology
    • /
    • 제21권4호
    • /
    • pp.494-500
    • /
    • 2020
  • Objective: This study presents a preliminary report on the chest radiographic and computed tomography (CT) findings of the 2019 novel coronavirus disease (COVID-19) pneumonia in Korea. Materials and Methods: As part of a multi-institutional collaboration coordinated by the Korean Society of Thoracic Radiology, we collected nine patients with COVID-19 infections who had undergone chest radiography and CT scans. We analyzed the radiographic and CT findings of COVID-19 pneumonia at baseline. Fisher's exact test was used to compare CT findings depending on the shape of pulmonary lesions. Results: Three of the nine patients (33.3%) had parenchymal abnormalities detected by chest radiography, and most of the abnormalities were peripheral consolidations. Chest CT images showed bilateral involvement in eight of the nine patients, and a unilobar reversed halo sign in the other patient. In total, 77 pulmonary lesions were found, including patchy lesions (39%), large confluent lesions (13%), and small nodular lesions (48%). The peripheral and posterior lung fields were involved in 78% and 67% of the lesions, respectively. The lesions were typically ill-defined and were composed of mixed ground-glass opacities and consolidation or pure ground-glass opacities. Patchy to confluent lesions were primarily distributed in the lower lobes (p = 0.040) and along the pleura (p < 0.001), whereas nodular lesions were primarily distributed along the bronchovascular bundles (p = 0.006). Conclusion: COVID-19 pneumonia in Korea primarily manifested as pure to mixed ground-glass opacities with a patchy to confluent or nodular shape in the bilateral peripheral posterior lungs. A considerable proportion of patients with COVID-19 pneumonia had normal chest radiographs.

흉부 방사선검사 영상을 이용한 한국인 정상 여성의 임신기와 비 임신기 심장크기와 심흉비 비교 (Comparison of Cardiac Size and Cardiac Thoracic Ratio in Pregnant and Non-pregnant Women of Normal Korean Women Using Chest X-ray)

  • 주영철;김규형
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제41권3호
    • /
    • pp.223-229
    • /
    • 2018
  • The purpose of this study is to present the reference values for cardiac size and cardiothoracic ratio change, normal range and diagnosis of cardiovascular disease in pregnancy and non pregnancy of normal Korean women using chest X-ray. The subjects of this study were 58 women, who were read as normal by chest radiologist, had chest radiography taken on both last month of pregnancy, pre-pregnancy and within 2 years following delivery. In this study, we defined the last month of pregnancy as pregnancy and before or post pregnancy as non-pregnancy. CS and CTR were measured by two radiological technologist who had clinical experience more ten years with Danzer's method. Statistical methods were paired t-test and one-way ANOVA. Significance level ${\alpha}$ was 0.05 and p-value 0.05 or less was statistically significant. For pregnancy, the mean of left and right cardiac size was $40.11{\pm}8.73mm$ and $89.51{\pm}11.9mm$, CS was $128.60{\pm}13.15mm$, CTR was $44.51{\pm}4.21%$. In non pregnancy, $36.50{\pm}8.18mm$ and $77.68{\pm}13.1mm$. CS and CTR were $114.18{\pm}14.28mm$ and $42.03{\pm}4.04%$. Both pregnancy and non pregnancy, the difference of the mean value in left and right cardiac size, CS and CTR were statistically significant (p<0.01). but comparing mean on age, height and weight, the difference of the mean value between groups was not (p>0.05). In the result of this study, the mean size of CS increased by 12.6% in pregnancy($128.60{\pm}13.15mm$) compared to the non pregnancy($114.18{\pm}14.28mm$), and increased by 9.8% in the right side of the heart and 15.2% in the left side. The mean size of CTR increased about 5.9% in pregnancy ($44.5{\pm}4.21%$) compared to non pregnancy($42.03{\pm}4.04%$).

흉부 전·후방향 검사 시 고관전압 및 산란선 후처리 소프트웨어 적용이 화질과 선량에 미치는 영향 (Effect of High Tube Voltage and Scatter Ray Post-processing Software on Image Quality and Radiation Dose During Chest Anteroposterior Radiography)

  • 김종석;주영철;이승근
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제44권4호
    • /
    • pp.295-300
    • /
    • 2021
  • This study aims to present new chest AP examination exposure conditions through a study on the effect on image quality and patient dose by applying high tube voltage and scatter ray post-processing software during chest AP examination in digital radiography equipment. This study was used a human body phantom and in the chest AP position, the dosimeter was placed horizontally at the thoracic spine 6. The experiment was conducted by dividing into a low tube voltage (70 kVp, 400 mA, 3.2 mAs) group and a high tube voltage (100 kVp, 400 mA, 1.2 mAs) group. The collimation size (14″× 17″) and the source to image receptor distance(110 cm) were same applied to both groups. Radiation dose was presented to dose area product and entrance surface dose. Image quality was compared and analyzed by comparing the difference between the signal-to-noise ratio and the contrast-to-noise ratio of the image according to the application of the scatter ray post-processing software under each condition. The average value of the entrance surface dose in the low and high tube voltage conditions was 93.04±0.45 µGy and 94.25±1.51 µGy, which was slightly higher in the high tube voltage condition, but the dose area product was 0.97±0.04 µGy and 0.93±0.01 µGy. There was a statistically significant difference in the group mean value(p<0.01). In terms of image quality, the values of the signal-to-noise ratio and the contrast noise ratio were higher in the high tube voltage than in the low tube voltage, and decreased when the scattering line post-processing function was used, but the contrast resolution was improved. If there is a scatter ray post-processing function during chest AP examination, it is helpful to actively utilize it to improve the image quality. However, when this function is not available, I thought that applying a higher tube voltage state than a low tube voltage state will help to realize images with a large amount of information without changing the dose.

S-align 기능을 이용한 흉부 전·후 방향 검사 시 적절한 X선관 각도에 관한 연구 (The Study of Appropriate X-ray Tube Angle for the Anterior-posterior Chest Radiography Using S-align Function)

  • 박명주;주영철;김민석;육정원;김한용;김동환
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제45권4호
    • /
    • pp.299-304
    • /
    • 2022
  • This study uses the 'S-align' function to present a reference value of the X-ray tube angle for the realization of an image similar to that of the chest PA image during chest AP radiography. This study targeted dummy phantom and used a 17"×17" DR image receptor. The irradiation conditions were 110 kVp, 160 mA, 50 ms, and the distance between the central X-ray and the image receptor was set to 180 cm and 110 cm, respectively. The end of the catheter was placed at the 11th thoracic height to indicate the nasogastric tube. In the case of lung apex length measurement, the mean value of measurement was 30.53±0.47 in PA. T 0°, TCA 5~25°, TCE 5~15° were 21.07±0.29, 27.60±0.21, 34.13±0.44, 39.86±0.31, 45.96±0.61 mm, 54.13±0.37 mm, 16.16±0.46 mm, 9.81±0.35 mm, 2.75±0.30 mm, respectively. For the depth of the catheter end, the average value measured at PA was 6.70±0.31 mm. T 0°, TCA 5~25°, TCE 5~15° were 15.72±0.38 mm, 24.10±0.50 mm, 29.24±0.86 mm, 34.35±0.35 mm, 41.06±1.08 mm, 48.07±0.38 mm, 12.85±0.25 mm, 7.92±0.36 mm, 3.01±0.39 mm, respectively. The length of the lung apex was similar to that of chest PA when the angle of incidence was adjusted from 5° to 10° in the leg direction, and the depth of the catheter tip was most similar when the X-ray tube angle was incident at 10° in the head direction. Therefore, To change the X-ray tube angle according to the purpose of the examination during the chest AP radiography using 'S-align' function is considered necessary.