• 제목/요약/키워드: thimble

검색결과 33건 처리시간 0.037초

Measurements of Thermal Neutron Spectrum Parameters in the TRIGA Mark II Reactor

  • Yang, Jae-Choon
    • Nuclear Engineering and Technology
    • /
    • 제11권1호
    • /
    • pp.21-27
    • /
    • 1979
  • TRIGA Mark II 원자로심에서 반응율을 측정하여 중성자 spectrum parameter인 상대적인 증성자 온도 T$^{n}$ 과 열외중성자 지수 (equation omitted)를 얻기 위해 해석하였다. 측정은 경수 환경하에 있는 central thimble과 F2위치에서 수행되었다. 상대적인 중성자 온도는 Lu과 Mn의 방사화율로 표시되며 열외중성자 지수는 Au와 Mn의 반응율에 의go서 측정된다. 이들 검출박의 상대적인 ${\gamma}$-에너지는 multichannel analyzer에 의해서 분석되었다. 실험 결과는 이론적인 계산치와 비교 평가되었다.

  • PDF

승강기의 종진동에 관한 연구 (A Study on the Longitudinal Vibration of Elevator)

  • 송달호;이유진;최영휴
    • 한국기계연구소 소보
    • /
    • 통권19호
    • /
    • pp.5-14
    • /
    • 1989
  • Analytical and experimental studies are performed to identify the longitudinal vibration characteristics of elevator system such as the natural frequencies, and the magnification factor at resonance. In the analytical study, a computer program is developed to analyze the vibration characteristics of elevator with varing rope length of elevtor, stiffenss of thimble rod spring, and excitation frequency. The shorter rope length and the stiffer thimble rod spring make the natural frequencies of elevator higer. The resonance at the first natural frequency spreads over the entire travelling range, whereas, that at the second one ranges relatively short, region. The first natural frequencies of the Gald-Star Twin Building and the Korea Trading Center Building obtained by the experiment are overall in good agreement with the analysis result..

  • PDF

Analysis of Standard and FLIP Fuel Mixed Loading Patterns in TRIGA Mark-III Reactor

  • Kim, Jung-Do;Lee, Jong-Tai;Yook, Chong-Chul
    • Nuclear Engineering and Technology
    • /
    • 제11권4호
    • /
    • pp.287-293
    • /
    • 1979
  • TRIGA Mark-III 원자로에서 사용하는 표준형 및 FLIP형 핵연로의 혼합장전 방법을 해석하였다. 검토된 핵연로 장전방법중 B링에 표준형 그리고 그외의 링에는 FLIP형 핵연료를 장전하는 방법이 핵연료의 온도, 냉각재의 자연대류 및 central thimble에서의 효율적인 열중성자 이용면에서 가장 바람직함을 입증하였다. 또한 핵연료 장전방법에 따른 beamport에서의 열중성자 이용에 관해서도 평가하였다.

  • PDF

측정기에 따른 고에너지 X-선의 표면 선량 및 최대 선량 지점 고찰 (Consideration of Surface Dose and Depth of Maximum Dose Using Various Detectors for High Energy X-rays)

  • 이용하;박경란;이종영;이익재;박영우;이강규
    • Radiation Oncology Journal
    • /
    • 제21권4호
    • /
    • pp.322-329
    • /
    • 2003
  • 목적 .: 고에너지 X-선의 표면 선량과 선량보강(build-up) 영역에서의 선량 분포는 일반적으로 방사선 계측에 사용되는 전리함 측정기로는 정확한 선량 분포를 얻기가 매우 어렵다. 본 연구는 고에너지 X-선 선량 계측에 보편적으로 사용되고 있는 여러 측정기를 이용하여 팬톰 표면에서의 흡수선량과 최대 선량 지점(d$_{max}$)을 측정하여 측정기 사이의 정확성을 비교 분석하고, 각 치료 기관에서 보편적으로 사용되는 측정기 중 표면 선량 측정에 적절한 측정장치를 제안하고 그 유용성을 제시하고자 한다. 대상 및 방법 : 본 실험에서는 6 MV와 IS MV X-선에 대해 조사면이 10$\times$10 cm$^{2}$, SSD=100 cm에서 TLD, 팀블형전리함(thimble type ion chamber), 다이오드 검출기, 다이아몬드 검출기와 Markus 평행판 전리함 등을 이용하여 심부선량백분율(percent depth dose: PDD)을 측정하여, 표면 선량(suface dose)과 최대 선량 지점(dnu)을 비교 분석하고, 또한 TLD 측정 시와 동일 조건으로 Monte Cario 계산을 실행하여 TLD의 측정 결과와 비교하였다. 결과: 6 WV와 IS MV X-선에 대해 Markus 평행판 전리함을 이용하여 측정한 표면 선량은 각각 29.31$\%$와 23.36$\%$으로 측정되었으며, TLD는 37.17$\%$와 24.06$\%$, 다이아몬드 검출기는 34.78$\%$와 24.06$\%$, 다이오드 검출기는 38.18$\%$와 27.8$\%$, 팀블형 전리함은 47.92$\%$와 36.06$\%$ 였으며, Monte Cario 계산에 의한 표면 선량 값은 S MV X-선에 대해 TLD 측정 시와 동일한 조건으로 팬톰 내에 가상적인 TLD를 삽입한 경우 36.22$\%$로 실제 측정값 37.17$\%$와 유사하였다. 최대 선량 지점의 깊이는 모든 측정기에서 6 MV X-선에 대하여 14$\~$16 mm, IS MV X-선에서는 27$\~$29 mm사이의 측정기에 따라 작은 차이를 보였다. 결론 : 표면 선량의 경우에는 측정기에 따라 현저한 차이를 보였으며 Markus 평행판 전리함이 사용된 측정기 중가장 정확한 결과를 보였고, 팀블형 전리함의 경우 다른 측정기에 비해 약 10$\%$ 이상 높은 선량을 보여 피부 표면에 가까이 위치한 종양에 대한 방사선 치료 계뵉 시에는 임상에서 가장 보편적으로 사용되고 있는 팀블형 전리함의 선량 값을 그대로 사용하기에는 많은 오류가 발생하므로 가능한 표면 선량 측정에 적절한 측정기를 선택하여 사용하거나 측정기 특성을 고려한 보정이 필요할 것으로 생각된다. 최대 선량 지점(d$_{max}$)의 결과는 모든 측정기에서 비슷한 결과를 나타내고 있어 본 실험에서 사용한 모든 측정기는 그 특성에 상관없이 최대 선량 지점 측정에 사용이 가능함을 알 수 있었다.

Validation of a New Design of Tellurium Dioxide-Irradiated Target

  • Fllaoui, Aziz;Ghamad, Younes;Zoubir, Brahim;Ayaz, Zinel Abidine;Morabiti, Aissam El;Amayoud, Hafid;Chakir, El Mahjoub
    • Nuclear Engineering and Technology
    • /
    • 제48권5호
    • /
    • pp.1273-1279
    • /
    • 2016
  • Production of iodine-131 by neutron activation of tellurium in tellurium dioxide ($TeO_2$) material requires a target that meets the safety requirements. In a radiopharmaceutical production unit, a new lid for a can was designed, which permits tight sealing of the target by using tungsten inert gaswelding. The leakage rate of all prepared targets was assessed using a helium mass spectrometer. The accepted leakage rate is ${\leq}10^{-4}mbr.L/s$, according to the approved safety report related to iodine-131 production in the TRIGA Mark II research reactor (TRIGA: Training, Research, Isotopes, General Atomics). To confirm the resistance of the new design to the irradiation conditions in the TRIGA Mark II research reactor's central thimble, a study of heat effect on the sealed targets for 7 hours in an oven was conducted and the leakage rates were evaluated. The results show that the tightness of the targets is ensured up to $600^{\circ}C$ with the appearance of deformations on lids beyond $450^{\circ}C$. The study of heat transfer through the target was conducted by adopting a one-dimensional approximation, under consideration of the three transfer modes-convection, conduction, and radiation. The quantities of heat generated by gamma and neutron heating were calculated by a validated computational model for the neutronic simulation of the TRIGA Mark II research reactor using the Monte Carlo N-Particle transport code. Using the heat transfer equations according to the three modes of heat transfer, the thermal study of I-131 production by irradiation of the target in the central thimble showed that the temperatures of materials do not exceed the corresponding melting points. To validate this new design, several targets have been irradiated in the central thimble according to a preplanned irradiation program, going from4 hours of irradiation at a power level of 0.5MWup to 35 hours (7 h/d for 5 days a week) at 1.5MW. The results showthat the irradiated targets are tight because no iodine-131 was released in the atmosphere of the reactor building and in the reactor cooling water of the primary circuit.

POLARITY AND ION RECOMBINATION CORRECTION FACTORS OF A THIMBLE TYPE IONIZATION CHAMBER WITH DEPTH IN WATER IN THE MEGAVOLTAGE BEAMS

  • Kim, Seong-Hoon;Huh, Hyun-Do;Choi, Sang-Hyun;Min, Chul-Hee;Shin, Dong-Oh;Choi, Jin-Ho
    • Journal of Radiation Protection and Research
    • /
    • 제34권2호
    • /
    • pp.43-48
    • /
    • 2009
  • When the PDD (percentage depth dose) in the megavoltage beams is measured in the water phantom, the polarity and ion recombination effects of ionization chambers with depth in water are not usually taken into consideration. We try to investigate if those variations with depth should be taken into consideration or could be ignored for the thimble type semiflex ionization chamber (PTW $31010^{TM}$, SN 1551). According to the recommendation of IAEA TRS-398, the 4 representative depths of $d_s$, $d_{max}$, $d_{90}$ and $d_{50}$ were used for the electron beams. For the photon beams, the 4 depths were arbitrarily chosen for the photon beams, which were $d_s$, $d_{max}$, $d_{10}$ and $d_{20}$. For the high energy photon beam both polarity and ion recombination factors of the chamber with depth in water gives the good agreements within the maximum $\pm$0.2%, while the $C_{polS}$ with depth came within the maximum $\pm$ 0.4% and the $C_{IRS}$ within the maximum $\pm$0.6% in every electron beam used. This study shows that PDI (percentage depth ionization) could be a good approximation to PDD for the chamber used.

노내 핵계측 계통 구동기기의 전자식 한계스위치 개발 (Development of Electronic Limit Switch for the Drive Unit of Incore Detector System Application)

  • 박종범;양승권;이상효
    • 조명전기설비학회논문지
    • /
    • 제14권4호
    • /
    • pp.1-7
    • /
    • 2000
  • 본 논문에서 원전의 핵연료 다발의 중섬자속을 측정할 수 있는 노내중성지속 감시계통의 구동모터를 제어하기 위한 스위치의 오동작 원인 분석 및 이 문제를 해결하기 위한 방안을 제시하고자 한다. 노내중성자속 감시계동은 검출기 안내관을 통해 검출기가 노심으로 삽입되거나 인출될 경우 접점선호를 발생하는 기계식 스위치레버를 장착하고 있다. 그러나 기계적인 열화나 환경적인 요인에 의해 기계식 스위치레버의 특성이 점점 변화되어 마침내 잘못된 접점신호를 발생하게 된다. 그러므로 아들 문제 해결을 위해 기계식 스위지 대선 전자식 스위치를 검출기 안내관 밖에 배치하였고, 공진효과를 이용하여 점점신호를 발생하는 회로개선과 소음 및 전기적 방해를 방지하기 위한 콘데서를 전자회로 전원 입력측에 설치하였다. 이러한 개선을 완료한 후, 여러 조건하에서 이 향상된 스위치 제어회로를 반복적으로 시험하였는데, 결국 이를 통해 원하는 접점신호를 얻게되었을 뿐 아니라 발전소 정상운전 중에 관련시스템의 주기시험을 통해서도 검출기 접점 오동작 신호가 발생되지 않음울 확인할 수 있게 되었다.

  • PDF