감도해석 및 순차적 선형계획법을 이용한 HDD 서스펜션의 형상 최적화 (Optimization of HDD Suspension Shape Using Sensitivity Analysis and Sequential Linear Proframing)

  • Hwang, Chang-Ho;Kim, Dong-Wook;Park, No-Cheol;Lee, Jongsoo;Park, Young-Pil
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2002년도 추계학술대회논문초록집
    • /
    • pp.319.2-319
    • /
    • 2002
  • The main obstacle to high track density in HDD id the structural resonances of the suspension. The most critical mode is sway mode and second torsion mode, when a data is read and written. It is common fact that the effect of two modes is smaller when a thickness is bulky. But the stiffness of suspension is smaller, the slider can follow a disk better. Because these two fact are reciprocal, a compromise is needed. So we investigated another method to improve band width without changing of the thickness of suspension but with changing of the shape. (omitted)

  • PDF

방사선투과시험(放射線透過試驗)에 있어서 KS와 ASME Code의 비교(比較)에 관(關)한 연구(硏究) (Study on Comparison of Korean Industrial Standard and ASME BPV Code for Radiographic Examination)

  • 김진구;박병철
    • 비파괴검사학회지
    • /
    • 제4권2호
    • /
    • pp.20-29
    • /
    • 1985
  • There are two basic concepts in industrial radiographic examination; one is a radio-graphic sensitivity, and the other is a acceptance criteria. The comparison of these main points are studied for KS Standard and ASME Boiler and Pressure Vessel Code. From the results of the experiment, higher radiographic sensitivity is required in KS Standard when the thickness of material to be examined is less than 20mm in single wall technique. The acceptance criteria for linear type indications are described on same concept in two standards, whereas the acceptance criteria for rounded indications of KS Standard which mainly depends upon the object thickness are more severe than those of ASME BPV Code.

  • PDF

GMR and Magnetization Study of Sputtered Permalloy/Cu Multilayer: The Influence of Temperature, Thickness and Number of Magnetic Layer

  • Lucinski, T.;Stobiecki, F.;Urbaniak, M.
    • Journal of Magnetics
    • /
    • 제4권1호
    • /
    • pp.17-21
    • /
    • 1999
  • The GMR ($d_Cu$) oscillatory behaviour as well as the widths of first and the second antiferromagnetically coupled ranges of the Permalloy ($Py=Ni_{83}Fe_{17}$)/Cu multilayers have been found to be strongly affected not only by the presence of the superparamagnetic/paramagnetic entitles located at the Py/Cu interfaces but mainly by the existence of the magnetic bridges between Py layers. The effectiveness of the magnetic bridges has been found to be temperature dependent, leading to the temperature dependence of the remnant to saturation magnetization ratio ($M_R/M_S$). We have found that for Py/Cu multilayers with equal Py and Cu layer thicknesses a high field sensitivity of the GMR effect (0.4%/Oe) and negligible hysteresis can be achieved when the number of Py layers decreases from 100 to 6. Sensitivity can be further improved by increasing the Py layers thickness, but the hysterstic effect becomes more pronounced then.

  • PDF

Pd이 도핑된 $SnO_2$ 박막 가스감지막의 특성 (Characteristics of Pd doped $SnO_2$ gas sensitive thin films)

  • 김진해;김대현;이용성;김정규;전춘배;박효덕;박기철
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 C
    • /
    • pp.1779-1781
    • /
    • 2000
  • Pd doped $SnO_2$ thin film sensors were prepared on alumina substrate by rf magnetron sputtering method. The sensitivity of thin film was investigated by varying the heat-treatment temperature, film thickness and gas species. The thin film heat-treated at 600$^{\circ}C$ and film thickness of 5000${\AA}$ showed the highest sensitivity at an operating temperature of 400$^{\circ}C$.

  • PDF

FEM을 이용한 맨드랠(Mandrel) 형광- 음향 수중 청음기의 설계에 관한 연구 (Design studies for mandrel type fiber-hydrophones with FEM)

  • 임종인;노용래
    • 한국음향학회지
    • /
    • 제16권3호
    • /
    • pp.73-80
    • /
    • 1997
  • 본 연구에서는 유한 요소법을 이용하여 작동 주파수 대역이 10kHz까지 이고, 무지향성 감도 특성을 갖는 광음향 변환맨드랠(mandrel)형 하이드로폰의 최적 구조를 설계하고자 하였다. 최적화 변수들은 유연성 구조물인 맨드랠의 형상과 청음기의 각부분 물성들이다. 맨드랠의 반경보다 길이 혹은 몰딩(molding) 두께가 증가할수록 광-음향 수중 청음기의 감도는 증가하였고, 맨드랠과 몰딩의 탄성 계수 및 포아손 비가 낮을수록 감도가 향상되는 경향을 보여주었다. 그리고 맨드랠 재료의 길이가 감소할수록 혹은 탄성율이 증가할수록 사용 주파수 영역이 증가하고, 하이드로폰의 길이가 짧을수록 감도의 무지향 특성이 향상 되었다. 이상의 결과를 이용하여 감도가 $30 {\times} 10_{-7}$ Rad./Pa에 이르고, 작동 주파수 영역이 10 kHz까지이며 5 kHz 주파수에서 무지향성을 갖는 유연성 구조물인 맨드랠형 광음향 하이드로론을 설계하였다.

  • PDF

Study on Electrical Properties of X-ray Sensor Based on CsI:Na-Selenium Film

  • Park Ji-Koon;Kang Sang-Sik;Lee Dong-Gil;Choi Jang-Yong;Kim Jae-Hyung;Nam Sang-Hee
    • Transactions on Electrical and Electronic Materials
    • /
    • 제4권3호
    • /
    • pp.10-14
    • /
    • 2003
  • In this paper, we have introduced the x-ray detector built with a CsI:Na scintillation layer deposited on amorphous selenium. To determine the thickness of the CsI:Na layer, we have estimated the transmission spectra and the absorption of continuous x-rays in diagnostic range by using computer simulation (MCNP 4C). A x-ray detector with 65 ${\mu}m$-CsI:Na/30 ${\mu}m$-Se layer has been fabricated by a thermal evaporation technique. SEM and PL measurements have been performed. The dark current and x-ray sensitivity of the fabricated detector has been compared with that of the conventional a-Se detector with 100 ${\mu}m$ thickness. Experimental results show that both detectors exhibit a similar dark current, which was of a low value below $400 pA/cm^2$ at 10 V/${\mu}m$. However, the CsI:Na-Se detector indicates high x-ray sensitivity, roughly 1.3 times that of a conventional a-Se detector. Furthermore, a CsI:Na-Se detector with an aluminium reflective layer shows a 1.8 times higher x-ray sensitivity than an a-Se detector. The hybrid type detector proposed in this work exhibits a low dark current and high x-ray sensitivity, and, in particular, excellent linearity to the x-ray exposure dose.

Ultrasonographic evaluation of skin thickness in small breed dogs with hyperadrenocorticism

  • Heo, Seonghun;Hwang, Taesung;Lee, Hee Chun
    • Journal of Veterinary Science
    • /
    • 제19권6호
    • /
    • pp.840-845
    • /
    • 2018
  • The purpose of this study was to propose a standard for differentiation between normal dogs and patients with hyperadrenocorticism (HAC) by measuring skin thickness via ultrasonography in small breed dogs. Significant changes in skin thickness of patients treated with prednisolone (PDS) or patients with HAC treated with trilostane were evaluated. Skin thickness was retrospectively measured on three abdominal digital images obtained from small breed dogs weighing < 15 kg that underwent abdominal ultrasonography. Mean skin thickness of normal dogs was $1.03{\pm}0.25mm$ (mean ${\pm}$ SD). Both the HAC and PDS groups showed significantly thinner skin than that in the normal group. Seven of the 10 HAC patients treated with trilostane had increased skin thickness. The area under the curve value of 0.807 was based on the receiver operating characteristics (ROC) curve for differentiating normal dogs from HAC patients. Sensitivity was 76% and specificity was 73% when skin thickness was less than the 0.83 mm cutoff value. In conclusion, measurement of skin thickness in small breed dogs by using ultrasonography is likely to provide clinical information useful in differentiating HAC patients from normal dogs. However, exposure to PDS, trilostane, and other conditions may have a significant effect on skin thickness.

역학적-경험적 덧씌우기 포장 설계 프로그램 개발 (Development of Mechanistic-Empirical Overlay Pavement Design Program)

  • 백철민;양성린;박희문;강태욱
    • 한국도로학회논문집
    • /
    • 제14권4호
    • /
    • pp.19-28
    • /
    • 2012
  • PURPOSES : Recently, the mechanistic-empirical overlay pavement design program that is linked with Korea Pavement Research Program (KPRP) has been developed. This paper focused on establishing the framework and developing the program for the asphalt overlay design over the existing asphalt concrete pavement. METHODS : The overlay pavement design program developed in this study was investigated to assess the sensitivity to various pavement conditions, such as the damage level and thickness of existing layers. In addition, the actual overlay design on currently performing pavement was carried out as a practical example. RESULTS : From the sensitivity analysis, it was found that the thickness and damage level of existing asphalt layer mostly affect the overlay design results. In addition, under the same condition, the overlay pavement would better perform in cold region. From the overlay design with the actual condition, it is noted that the overlay thickness varies depending on the given condition. CONCLUSIONS : Based on various evaluations, it was concluded that the overlay design program developed in this study is a reliable and reasonable tool to be used in the actual pavement design.

Ta/NiFe/Cu/Co Pseudo 스핀밸브 구조의 자기저항 효과 (Magnetoresistance Effect of Ta/NiFe/Cu/Co Pseudo Spin Valve Structure)

  • 주호완;최진협;최상대;이기암
    • 한국자기학회지
    • /
    • 제14권1호
    • /
    • pp.25-28
    • /
    • 2004
  • Ta/NiFe/Cu/Co 구조의 Pseudo 스핀밸브 박막을 제작하여 NiFe, Cu, Co 각 층들의 두께변화에 따른 자기저항비(MR-ratio), 보자력, 자기 민감도(sensitivity), 반전자장(Switching Field)의 크기 등의 자기적 특성을 연구하였다. 각 층들의 두께를 변화시키면서 측정한 결과 Ta(4 nm)/NiFe(7.5 nm)/Cu(3 nm)/Co(5 nm)에서 최대 자기저항비 7.26 %를 얻을 수 있었다. 또한 각 층들의 독립적인 자화 과정을 통해 자기저항 특성을 조절할 수 있었다. 특히 Co의 두께를 변화시켜 자기저항비를 비교적 일정하게 유지하면서 보자력의 크기를 조절할 수 있음을 알게 되었다.

비정질 셀레늄 기반의 X선 검출 센서의 전하 수송 특성 (Charge Transport Characteristics of a-Se based X-ray Detector)

  • 강상식;차병열;장기원;김재형;남상희
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2002년도 추계학술대회 논문집 Vol.15
    • /
    • pp.375-378
    • /
    • 2002
  • There has recently been a great deal of interest in amorphous selenium for application of digital x-ray image sensor. The initial number of the electron-hole induced by interaction a-Se with x-ray photons and the collection efficiency to surface of generated charges are important parameters for x-ray sensitivity of the a-Se. Therefore, in this paper, we analyzed that thickness of a-Se film and electric field is affected on the initial number of electron-hole and the collection efficiency. The experimental value of x-ray induced charge about the various thickness and the electric field is compared with estimated absorbed energy through MCNP 4C code to analyze the mechanism x-ray induced signal of a-Se. The experimental results showed that the electric field depends on initial escape coefficient and the thickness depends on collection coefficient than escape efficient.

  • PDF