• Title/Summary/Keyword: thickness of the specimen

Search Result 1,056, Processing Time 0.029 seconds

New test method for real-time measurement of SCC initiation of thin disk specimen in high-temperature primary water environment

  • Geon Woo Jeon;Sung Woo Kim;Dong Jin Kim;Chang Yeol Jeong
    • Nuclear Engineering and Technology
    • /
    • v.54 no.12
    • /
    • pp.4481-4490
    • /
    • 2022
  • In this study, a new rupture disk corrosion test (RDCT) method was developed for real-time detection of stress corrosion cracking (SCC) initiation of Alloy 600 in a primary water environment of pressurized water reactors. In the RDCT method, one side of a disk specimen was exposed to a simulated primary water at high temperature and pressure while the other side was maintained at ambient pressure, inducing a dome-shaped deformation and tensile stress on the specimen. When SCC occurs in the primary water environment, it leads to the specimen rupture or water leakage through the specimen, which can be detected in real-time using a pressure gauge. The tensile stress applied to the disk specimen was calculated using a finite element analysis. The tensile stress was calculated to increase as the specimen thickness decreased. The SCC initiation time of the specimen was evaluated by the RDCT method, from which result it was found that the crack initiation time decreased with the decrease of specimen thickness owing to the increase of applied stress. After the SCC initiation test, many cracks were observed on the specimen surface in an intergranular fracture mode, which is a typical characteristic of SCC in the primary water environment.

Influence of dimensional ratio on collapse characteristics for the thin-walled structures of light weight (경량화용 박육부재의 형상비가 압궤특성에 미치는 영향)

  • 정종안;김정호;양인영
    • Journal of the Korean Society of Safety
    • /
    • v.13 no.3
    • /
    • pp.11-23
    • /
    • 1998
  • In this study, collapse test of thin-walled structure is performed under axially quasi-static and impact load in collapse characteristic to develop the optimum structural member for a light-oriented automobile. Furthermore, the energy-absorbing capacity is observed according to the variety of configuration(circular, square), aspect ratio in aluminum specimen to obtain basic data for the improved member of vehicle. In both quasi-static and impact collapse test, Al circular specimens collapse, in general, with axisymmetric mode in case of thin thickness while collapse with non-axisynmetric mode according to the thickness increase. For Al rectangular specimens, they collapse with axisymmetric mode in case of thin thickness, with mixed collapse mode according to the increase of thickness. In terms of initial max. load, Al square specimen turns out the best member among specimens, and then Al square, circular and circular with large scaling ratio, respectively. In case of quasi-static compression test, the absorbed energy per unit volume and mass shows higher in Al circular specimen, and then Al square, circular with large scaling ratio, respectively, according to shape ratio the absorbed energy per unit volume and mass in case of max. impact compression load is higher than that of static load. But the absorbed energy per unit volume and mass shows that Al circular specimen is the best member. Especially, unlike max. compression loan, the absorbed energy per unit volume and mass in impact test turns out the low value.

  • PDF

Dimensional Responses of Wood Under Cyclical Changing Temperature at Constant Relative Humidity

  • Yang, Tiantian;Ma, Erni;Shi, Yi
    • Journal of the Korean Wood Science and Technology
    • /
    • v.43 no.5
    • /
    • pp.539-547
    • /
    • 2015
  • To investigate dimensional responses of wood under dynamic temperature condition, poplar (populous euramericana Cv.) specimens, 20 mm in radial (R) and tangential (T) directions with two thicknesses of 4 and 10 mm along the grain, were exposed to cyclic temperature changes in square wave between $25^{\circ}C$ and $40^{\circ}C$ at 60% relative humidity (RH) for three different cycling periods of 6 h, 12 h and 24 h. R and T dimensional changes measured during the cycling gave the following results: 1) Transverse dimensional changes of the specimens were generally square but at an opposite phase and lagged behind the imposed temperature changes. The phase lag was inversely correlated with cycling period, but positively related to specimen thickness, while the response amplitude was directly proportional to cycling period, but in a negative correlation with specimen thickness. 2) The specimens showed swelling hysteresis behavior. The heat shrinkage coefficient (HSC) became greater as cycling period increased or specimen thickness decreased. 3) Dimensional changes of the specimens produced deformation accumulation during repeated adsorption and desorption. The deformation accumulating ratio decreased with an increase in cycling period and specimen thickness. 4) Wood suffered 1.5 times as many dimensional changes per unit temperature variation as per unit humidity variation, and this deformation behaved even more seriously under static condition.

An Experimental Study on the Factors that Affect Fatigue Crack Growth Retardation Behavior in S45C Steel (S45C 강의 피로균열전파 지연거동의 영향인자에 관한 실험적 연구)

  • Kim, Seon-Jin;An, Seok-Hwan
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.25 no.3
    • /
    • pp.470-477
    • /
    • 2001
  • Constant ΔK fatigue crack growth tests were performed by applying an intermediate multiple overload for S45C steel. The purpose of the present study is to investigate effects of specimen thickness at various baseline stress intensity factor range levels (ΔK(sub)b), overload application position (a/W) and overload application frequency (OL(sub)HZ) on fatigue crack growth retardation behavior. The principal results are summarized as follows. The amount of retardation for a given ΔK(sub)b level is increased with increasing the baseline stress intensity factor range level for all specimen thickness. The normalized minimum crack growth rate is increased with increasing the specimen thickness, except for ΔK=45MPa√m. The retardation cycle is decreased with increasing a/W and increased with OL(sub)HZ.

An Experimental Study on the Factors that Affect Fatigue Crack Growth Retardation Behavior in SM45C Steel (SM45C 강의 피로균열전파 지연거동에 미치는 영향인자에 관한 실험적 연구)

  • Kim, Seon-Jin;Kim, Jong-Hoon;Ahn, Seok-Hwan
    • Proceedings of the KSME Conference
    • /
    • 2000.04a
    • /
    • pp.55-60
    • /
    • 2000
  • Constant ${\Delta}K$ fatigue crack growth tests were performed applying an intermediate multiple overload for SM45C steel. The purpose of the present study is to investigate the effects of specimen thickness at various baseline stress intensity levels$({\Delta}K_b)$, overload application frequency(a/W) and overload application frequency$(OL_{HZ})$ on fatigue crack growth retardation behavior. The principal results are summarized as follows. The amount of retardation for a given ${\Delta}K_b$ level is increased with increasing the baseline stress intensity level in all specimen thickness. The normalized minimum crack growth rate is increased with increasing the specimen thickness, except for ${\Delta}K=45MPa \sqrt m$. The retardation cycle is decreased with increasing the overload application position and increased with the overload application frequency.

  • PDF

The Effect of Thickness of Plate on Fatigue Crack Propagation Behavior by Indentations (판두께에 따른 압흔가공에 의한 피로크랙 전파거동)

  • 송삼홍;최진호
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1994.10a
    • /
    • pp.826-830
    • /
    • 1994
  • Making Brinell indentations facing each other near the crack tip is very effective method in increasing fatigue life. In this paper, fatigue test was performed after indentation to investigate the effect of thickness of specimen. The results show that fatigue lives increased my making indentation and retardation cycle is inverse proportional to thickness of specimen.

  • PDF

Effect of Lateral Diffusion on Hydrogen Permeation Measurement in Thick Steel Specimens

  • Traidia, A.;El-Sherik, A.M.;Attar, H.;Enezi, A.
    • Corrosion Science and Technology
    • /
    • v.16 no.4
    • /
    • pp.201-208
    • /
    • 2017
  • A finite element analysis is proposed to study the effect of specimen dimensions on lateral diffusion of hydrogen during hydrogen permeation flux measurements. The error of measurement on thick specimens because of 1D diffusion approximation may be as much as 70%. A critical condition for accurate measurements is to designate the area of hydrogen monitoring/exit surface smaller than the area of hydrogen charging/entry surface. For thin to medium thickness specimens (ratio of thickness to specimen radius of 5:10 and below), the charging surface should be maximized and the monitoring surface should be minimized. In case of relatively thick specimens (ratio of thickness to specimen radius above of 5:10), use of a hydrogen-diffusion barrier on the specimen boundaries is recommended. It would completely eliminate lateral losses of hydrogen, but cannot eliminate the deviation towards 2D diffusion near the side edges. In such a case, the charging surface should be maximized and the monitoring surface should be as closer in dimension as the charging surface. A regression analysis was carried out and an analytical relationship between the maximum measurement error and the specimen dimensions is proposed.

The Thickness Effect on the Determination of Fracture Toughness Jic (파괴인성치 Jic 결정에 대한 시험편 두께의 영향에 관한 연구)

  • 고성위
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.24 no.2
    • /
    • pp.83-93
    • /
    • 1988
  • Recent Experimental results show that the J integral can be effectively used to obtain a valid parameter for predicting plane strain and plane stress fracture. However, only a few research results have been reported for the effect of thickness where the plane strain state can not be assumed. A purpose of this study is to find the behavior of fracture touhness and tearing modulus varing the specimen thickness. The type of specimen in the present study is compact tension (CT). The thicknesses of the low carbon steel specimens that are used in the experiments are 5, 10, 15, 20 and 25mm. The measurement of crack length is taken by optical measurements method. From the study, the followings are found; 1) The fracture toughness and the tearing modulus which are obtained by using Yoon's and Simpson's formula show more conservative than that by using Rice's and Merkel's. 2) The fracture toughness is increase in specimen thickness which is reached 15mm. Beyond this thickness the fracture toughness is decreased in specimen thickness. 3) In the case of CT specimen with the thickness ranging from 5 to 25mm, the tearing modulus which is applied the same J integral equation is almost constant. 4) By using Yoon's formula, the correlation of the plane slress fracture toughness J sub(C) with specimen thickness B is expressed as the following formula. J sub(C)/J sub(IC)=1.7-15.1(B/W)+112.9(B/W) super(2) -301.3(B/W) super(3) +260.6(B/W) super(4)

  • PDF

Manufacturing and Performance Evaluation on Specimen pipes with Large Size Diameter and Thin Thickness for KSLV-II (한국형 발사체 적용 대형 박판 배관 시편 제작 및 성능 평가)

  • Lee, Hanju;Lee, Jung Ho;Oh, Seung Hyub
    • Aerospace Engineering and Technology
    • /
    • v.12 no.1
    • /
    • pp.81-86
    • /
    • 2013
  • This article deals with the manufacturing and performance evaluation on the specimen pipes which have large size diameter and thin thickness. This specimen is for LOX main pipe of KSLV-II propulsion feeding system. The material of specimen is alloy 21-6-9. Alloy 21-6-9 has higher strength and better weldability rather than STS-300 class pipes. We found that the specimen using alloy 21-6-9 satisfied the requirement by pressurization tests.

Comparative study on the specimen thickness measurement using EELS and CBED methods

  • Yoon-Uk Heo
    • Applied Microscopy
    • /
    • v.50
    • /
    • pp.8.1-8.7
    • /
    • 2020
  • Two thickness measurement methods using an electron energy loss spectroscopy (EELS) and 10a convergent beam electron diffraction (CBED) were compared in an Fe-18Mn-0.7C alloy. The thin foil specimen was firstly tilted to satisfy 10a two-beam condition. Low loss spectra of EELS and CBED patterns were acquired in scanning transmission electron microscopy (STEM) and TEM-CBED modes under the two-beam condition. The log-ratio method was used for measuring the thin foil thickness. Kossel-Möllenstedt (K-M) fringe of the $13{\ba{1}}$ diffracted disk of austenite was analyzed to evaluate the thickness. The results prove the good coherency between both methods in the thickness range of 72 ~ 113 nm with a difference of less than 5%.