• Title/Summary/Keyword: thickness of sand layer

Search Result 72, Processing Time 0.028 seconds

Constant Rate of Strain Consolidation Test with Rowe Cell on the Clay with Sand Seam (샌드심이 존재하는 점토에 Rowe Cell를 이용한 일정변형률 압밀시험)

  • Kim, Jae-Hong;Kim, Chan-Kee;Kim, Tae-Hyung
    • Journal of the Korean Geotechnical Society
    • /
    • v.33 no.5
    • /
    • pp.5-13
    • /
    • 2017
  • The sand layer deposited in clay is called a sand seam, which is formed by inflow of sands due to river flooding or slope failure in the middle of sinking and sediment of clay. When the sand seam exists in clay layer, the drainage direction changes from one way to both ways, and the time of consolidation may be reduced. However, it is not clearly proved due to lack of studies of sand seam and currently is not reflected in the design of soft soil improvement. As a fundamental study about sand seam, the oedometer tests and constant rate of strain tests with Rowe cell were conducted on clay specimens with sand seam. For tests, a frozen method was specially designed for making the sand seam. It was concluded that the test results showed the sand seam affects the coefficient of consolidation of clay. If the thickness of sand seam exceeds 0.05 times of specimen height, the sand seam works as drainage layer of pore water horizontally as well as vertically, and consequently the consolidation is accelerated.

Risk Of Buildings Damage Due To Subsidence During Tunnelling Under The Buildings In Sand-Gravel Layer (빌딩하부 모래자갈층에서 터널시공 중 발생한 지표침하에 의한 빌딩의 손상)

  • Kim, Cheehwan
    • Tunnel and Underground Space
    • /
    • v.25 no.4
    • /
    • pp.383-396
    • /
    • 2015
  • It is analyzed the risk of building damage due to ground surface subsidence occurred during constructing a tunnel below buildings in sand-gravel layer. The overburden and the thickness of sand-gravel layer is about 20m and the width and the height of the tunnel are 12m and 8.6m, respectively. The tunnel is pre-reinforced by umbrella method with three rows of long steel pipes and grouting. Surface subsidence is measured at 36 points surrounding buildings and measured data are used to calculate optimized three dimensional subsidence surface. Depending on the building location, deflection ratio and horizontal strain are calculated to evaluate the risk of building damage. No damage occurs at the buildings because of both the small deflection ratios involved 1~4mm subsidence and compressive horizontal strains.

Evaluation of Horizontal Force on Pile Shaft Surrounded by Vertical PET Aggregate Layer for Fluid Machinery Structure Installation in Cold Region's Plant (동토 플랜트 유체기계 구조물 설치를 위한 PET 골재적용 말뚝의 주면작용 수평력 평가)

  • Ji, Subin;Jang, Sung Min;Hwang, Soon Gap;Lee, Kicheol;Kim, Dongwook
    • The KSFM Journal of Fluid Machinery
    • /
    • v.19 no.3
    • /
    • pp.43-47
    • /
    • 2016
  • Pile foundations constructed on extremely cold regions cause serviceability problems of superstructures from repeated actions of ground freezing and thawing. Oil sand module plants are mainly constructed on seasonal frozen ground. Due to the freezing and thawing actions of grounds, vertical movements of piles have been observed. To solve these erratic pile movement problems, thin vertical layer of PET aggregates is installed around the pile shaft to prevent potential unfavorable pile movements. There is no known method to calculate "thin PET aggregate layer" -surrounded pile shaft resistance (capacity) against vertical loads; therefore, this experimental research is conducted. Specifically, in this study, horizontal (normal) pressures on pile shaft were assessed varying PET aggregate layer thickness based on the experiment.

Effect of Pile Head Constraint on Lateral Behavior of Single Rigid Pile in Two-Layered Sand Soil (2개층 사질토지반에서 단일 강성말뚝의 수평거동에 대한 두부 구속영향)

  • 김영수;서인식;김병탁;이상웅
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 1999.03a
    • /
    • pp.217-224
    • /
    • 1999
  • This Paper shows the results of a series of model tests on the behavior of single rigid Pile, which subjected to lateral load, in non-homogeneous Nak-Dong River sands, consisted of two layers, upper and lower layers. The purpose of the present paper is to investigate the effect of ratio of lower layer thickness to embedded pile length ratio of soil modules of upper to lower layer (E$\sub$h1//E$\sub$h2/) and pile head constraint condition on the characteristics of lateral behavior of single pile. These effects can be quantified only by the results of model tests. As a model test result, in non-homogeneous sand, it shows that the lateral behavior depends upon the ratio of soil modules of upper to lower layer more than other factors. And, in respect of deflection, it was found that the reduction ratio of deflection by pile head fixity is the value of 0.5 and 0.6 for E$\sub$h1//E$\sub$h2/=0.18 and E$\sub$h1//E$\sub$h2/=5.56, respectively. The critical thickness of lower layer on the change of deflection is about 25 - 50% of pile embedded length. Also, in respect of maximum bending moment it was found that the reduction ratio of maximum bending moment by pile head fixity is the value of 0.55 and 0.7 for E$\sub$h1//E$\sub$h2/=0.18 and E$\sub$h1//E$\sub$h2/=5.56, respectively.

  • PDF

Finite Element Analysis of Structural Performance of Anti-Freezing Layer via the Korea Pavement Research Program (한국형포장설계프로그램 및 유한요소해석을 이용한 동상방지층의 구조적 성능 평가)

  • Kim, Dowan;Lee, Junkyu;Mun, Sungho
    • International Journal of Highway Engineering
    • /
    • v.18 no.2
    • /
    • pp.83-90
    • /
    • 2016
  • PURPOSES : Nowadays, cavity phenomena occur increasingly in pavement layers of downtown areas. This leads to an increment in the number of potholes, sinkholes, and other failure on the road. A loss of earth and sand from the pavement plays a key role in the occurrence of cavities, and, hence, a structural-performance evaluation of the pavement is essential. METHODS: The structural performance was evaluated via finite-element analysis using KPRP and KICTPAVE. KPRP was developed in order to formulate a Korean pavement design guide, which is based on a mechanical-empirical pavement design guide (M-EPDG). RESULTS: Installation of the anti-freezing layer yielded a fatigue crack, permanent deformation, and international roughness index (IRI) of 13%, 0.7 cm, and 3.0 m/km, respectively, as determined from the performance analysis conducted via KPRP. These values satisfy the design standards (fatigue crack: 20%, permanent deformation: 1.3 cm, IRI: 3.5 m/km). The results of FEM, using KICTPAVE, are shown in Figures 8~12 and Tables 3~5. CONCLUSIONS: The results of the performance analysis (conducted via KPRP) satisfy the design standards, even if the thickness of the anti-freezing layer is not considered. The corresponding values (i.e., 13%, 0.7 cm, and 3.0 m/km) are obtained for all conditions under which this layer is applied. Furthermore, the stress and strain on the interlayer between the sub-grade and the anti-freezing layer decrease gradually with increasing thickness of the anti-freezing layer. In contrast, the strain on the interlayer between the sub-base and the anti-freezing layer increases gradually with this increase in thickness.

Analysis of Settlement Characteristics of Shallow Foundation on Sandy Soil Overlained by Rigid Ground (강성지반위 사질토층에 위치한 얕은기초의 침하량특성분석)

  • Hwang, Hui-Seok;Kim, Dong-Geon;Yoo, Nam-Jae
    • Journal of Industrial Technology
    • /
    • v.34
    • /
    • pp.45-52
    • /
    • 2014
  • In this paper the settlement characteristic of shallow foundation on sandy soil overlained by rigid ground was investigated by analyzing results of model tests. For model experiments, model tests were performed with sandy soils sampled from the field, changing the relative density of sandy soil and the ratio of thickness of sandy layer(H) to the width of model strip footing(B). As result of tests, settlement of sandy soils increases as the value of H/B increases, whereas it increases with relative density of soil. Bearing capacity decreases as the thickness of the sand layer relative to the footing width increases. In order to analyze the settlement characteristics of sandy ground, the results of model tests were compared with the predicted values using the empirical formulas proposed by Terzaghi, De Beer and Schmertmann. The method by De Beer was found to be in good agreements with test results.

  • PDF

Evaluation of Vertical Bearing Capacity of Bucket Foundations in Layered Soil by Using Finite Element Analysis (유한요소해석을 통한 다층지반에서의 버킷기초 수직지지력 산정)

  • Park, Jeong-Seon;Park, Duhee;Yoon, Se-Woong;Saeed-ullah, Jan Mandokhai
    • Journal of the Korean Geotechnical Society
    • /
    • v.32 no.7
    • /
    • pp.35-45
    • /
    • 2016
  • Estimation of vertical bearing capacity is critical in the design of bucket foundation used to support offshore structure. Empirical formula and closed form solutions for bucket foundations in uniform sand or clay profiles have been extensively studied. However, the vertical bearing capacity of bucket foundations in alternating layers of sand overlying clay is not well defined. We performed a series of two-dimensional axisymmetric finite element analyses on bucket foundations in sand overlying clay soil, using elasto-plastic soil model. The load transfer mechanism is investigated for various conditions. Performing the parametric study for the friction angles, undrained shear strengths, thickness of sand layer, and aspect ratios of foundation, we present the predictive charts for determining the vertical bearing capacities of bucket foundations in sand overlying clay layer. In addition, after comparing with the finite element analysis results, it is found that linear interpolation between the design charts give acceptable values in these ranges of parameters.

Effect of Pile Head Constraint on Lateral Behavior of Single Flexible Pile in Non-homogeneous Sand (비균질 사질토 지반에서 단일 휨성말뚝의 수평거동에 대한 말뚝 두부 구속효과 연구)

  • 김병탁;김영수;정성관
    • Journal of the Korean Geotechnical Society
    • /
    • v.15 no.5
    • /
    • pp.65-80
    • /
    • 1999
  • This paper shows the results of a series of model tests on the behavior of single flexible pile, which is subjected to lateral load, in non-homogeneous Nak-Dong River sands, consisting of two layers. The purpose of the present paper is to investigate the effects of ratio of lower layer thickness to embedded pile length, ratio of soil modulus of upper layer to lower one, and pile head constraint condition on the characteristics of lateral behavior of single pile. These effects can be quantified only by the results of model tests. Based on the results of model tests, in non-homogeneous sand, it was found that the lateral behavior depends upon the ratio of soil modulus of upper layer to lower one. And, in respect of deflection, it was found that the relationship between the deflection ratio of non-homogeneous to homogeneous sand and the ratio of lower layer thickness to embedded pile length can be fitted to exponential function of H/L and lateral load by model tests results. Also, in respect of maximum bending moment, it was found that the relationship H/L and $MBM_{fixed-head}/MBM_{free-head}$ can be fitted to linear function of H/L by model test results.

  • PDF

지표레이다(GPR) 탐사에 의한 하상퇴적물 조사

  • Jang, Hyeon-Sam;Jeong, Seong-Tae
    • Journal of the Korean Geophysical Society
    • /
    • v.5 no.1
    • /
    • pp.51-62
    • /
    • 2002
  • Investigation of underwater sedimentary layers has been carried out with GPR(Ground Penetration Radar) survey. FPR survey has been proved to be very satisfactory since the target area has shallow water depth of about 2.5 m, is a lake with no water flow, and the thickness of mud layer, which is a main survey target, is relatively thin. The results clearly showed the underwater sedimentary layers, which includes mud, sand, gravel and basement layer. Specially, the distribution and total amount of mud layers from the survey results can be used as a basic data for the dredging of mud layer in the area.

  • PDF

Ultimate Uplift Capacity of Circular Anchors in Layered Soil

  • Shin, Eun-Chul;Das, Braja-M
    • Geotechnical Engineering
    • /
    • v.14 no.3
    • /
    • pp.63-72
    • /
    • 1998
  • Laboratory model test results for ultimate uplift capacity of horizontal circular anchors embedded in soft clay overlain by dense sand are presented. The effect of the critical embedment ratio on the thickness of the clay layer was evalyated. An approximate preocedure for estimating the net ultimate capacity is presented.

  • PDF