• Title/Summary/Keyword: thickness of lens

Search Result 187, Processing Time 0.028 seconds

Effect of Hydrogel lens and Silicone-Hydrogel lens on Corneal thickness (하이드로겔 렌즈와 실리콘-하이드로겔 렌즈가 각막 두께에 미치는 영향)

  • Seo, Jung-Ick
    • Journal of Korean Clinical Health Science
    • /
    • v.5 no.4
    • /
    • pp.1021-1025
    • /
    • 2017
  • Purpose: Changes in corneal thickness after wearing hydrogel lens and silicone-hydrogel lens with different oxygen transmission rates wew syudied. Methods: Experiments were performed on 11 subjects(22 eyes). corneal thickness was measured after wearing contact lenses for 8 hours. Corneal thickness was measured using ORB Scan II(ver. 3.14) Results: In the results of the corneal thickness measurement by direction, in the case of the hydrogel-tor lens, the center thickness was $33.63{\mu}m$, the nasal was $34.29{\mu}m$, the temporal was $27.17{\mu}m$, the inferior was $27.17{\mu}m$, the superior was $18.90{\mu}m$, and change rates were 6.28%, 5.71%, 5.40%, 4.75% and 3.09%, respectively. In the results of the corneal thickness measurement by diameter, in the case of the hydrogel-tor lens, the center was $33.63{\mu}m$, the mid-peripheral was $28.19{\mu}m$, the peripheral was $24.18{\mu}m$, and change rates were 6.28%, 4.76%, and 3.79%, respectively. Conclusions: The hydrogel lenses with relatively low oxygen transmission rates resulted in a significant increase in thickness over the entire cornea compared to silicon-hydrogel lenses with high oxygen transmission rates.

The Performance Analysis and Design of Selling Spectacle Lenses in Domestic Market (국내 시판 안경렌즈의 성능 분석 및 설계)

  • Kim, Se-Jin;Lim, Hyeon-Seon
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.15 no.4
    • /
    • pp.355-360
    • /
    • 2010
  • Purpose: Analysis performance for spectacle lens which sales in domestic market and optimization design a spectacle lens which is corrected aberration. Methods: Measured center thickness, radius and aspherical surface coefficient for spherical and aspherical lenses which were ${\pm}$5.00D. Refractive index for every lens was 1.6 and they came from 4 different companies. I used 3 types of equipment to measure lenses. ID-F150 (Mitutoyo) : Center Thickness, FOCOVISION (SR-2, Automation Robotics) : Radius, PGI 1240S (Taylor Hobson) : Aspherical surface coefficient. Designed a lens which had 27 mm of distance from lens rear surface to center of eye, 4 mm of pupil diameter and small aberration on center vision $30^{\circ}C$. To shorten axial distance compared with the measured lens rise merits for cosmetic. Lens Design tool was CODE V (Optical Research Associates). Results: -5.00D aspherical lens had somewhat high astigmatism and distortion compared with the spherical lens. But it had a merit for cosmetic because of short axial height and decrease edge thickness. Improved a performance of distortion and ascertain merits for cosmetic due to short axial height and decrease edge thickness same as (-) lens in case of +5.00 aspherical lens. Though an optimization process front surface aspherical lens had a good performance for astigmatism and distortion and the merit for beauty compared with measured spherical lens. Conclusions: Design trend for domestic aspherical lens is decrease axial height and thickness to increase a merit for cosmetic not but increase performance of aberration. From design theory for optimization design front surface aspherical spectacle lens which has improved performance of aberration and merit for cosmetic at the same time compared with the measured lens. Expect an improved performance from design back aspherical lens compared with front aspherical lens.

An Excel Program for Dk Calculation of Contact Lens (엑셀 프로그램을 이용한 콘택트렌즈의 Dk 결정)

  • Kim, Dae Soo
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.16 no.1
    • /
    • pp.107-116
    • /
    • 2011
  • Purpose: The review article was written to establish an excel program that could calculate minimal Dk of contact lens without $O^2$ deficiency and actual $O^2$ concentration on cornea when contact lens were being fitted by changing lens-related factors. Methods: An excel program was formulated to calculate the thickness of post-lens lacrimal layer, Dk of contact lens and $O^2$ concentration on cornea. Results: With the excel program established, minimal $O^2$ concentration needed on cornea could be calculated when the thickness of post-lens lacrimal layer was changed by varying lens-related factors. A different route in the excel program was needed to choose based on the shape of lacrimal layer. The thickness of lacrimal layer was determined by the shape of meniscus made of tear between lens edge and cornea with flat fit. Thus, the $O^2$ concentration showing negative number in calculation decreased on peripheral cornea with flatter fitting and actual $O^2$ concentration would be zero on cornea. With tight fitting, the thickness of post-lens lacrimal layer is much thicker than lens itself thus negative number in calculation by the excel program is shown indicating zero oxygen on cornea. It can cause $O^2$ deficiency regardless of Dk of contact lens. Conclusions: The calculation of thickness of post-lens lacrimal layer and $O^2$ concentration on cornea by the established excel program is suggested to avoid $O^2$ deficiency when fitting state is varied by changing lens-related factors.

A study on searching method of molding condition to control the thickness reduction of optical lens in plastic injection molding process (플라스틱 광학렌즈 사출성형에 있어서 수축 변형량 예측을 위한 사출성형 조건 탐색에 관한 연구)

  • 곽태수;오오모리히토시;배원병
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.21 no.2
    • /
    • pp.27-34
    • /
    • 2004
  • In the injection molding of plastic optical lenses, the molding conditions have critical effects on the quality of the molded lenses. Since there are many molding parameters involved in injection molding process, determination of the molding conditions for lens molding is very important in order to precisely control the surface contours of an optical lens. Therefore this paper presents the application of neural network in suggesting the optimized molding conditions for improving the quality of molded parts based on data of FE Analysis carried out through CAE software, Timon-3D. Suggested model in this paper, which serves to learn from the data of FE Analysis and induce the values for optimized molding conditions. has been implemented for searching the molding conditions without void and with minimized thickness shrinkage at lens center of injection molding optical lens. As the result of this study. we have confirmed that void creation at the inside of lens is primarily determined by mold temperature and thickness shrinkage at center of lens is primarily determined by the parameters such as holding pressure and mold temperature.

Fundamentals of Tight fitted Contact Lens Movement (Tight Fit 콘택트렌즈 운동의 기초)

  • Kim, Dae Soo
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.14 no.3
    • /
    • pp.17-27
    • /
    • 2009
  • Purpose: This review article was written to determine the effects of parameters characterizing a hard contact lens (RGP included), such as BCs, diameters, edge angles, on the time interval for tight fitted lens to return to the equilibrium when it was decentered from blinking. Methods: A mathematical formulation was established to relate or calculate the restoring forces and thickness of lacrimal layer beneath the cornea with the various lens parameters when the tight fitted lens was decentered from blinking. Based on this formulation the differential equations and their numerical solution program were set up to describe the time dependence of the lens on the position and to estimate the time for the lens's return to the equilibrium after blink. Results: It is found that the time interval for the tight fitted lens to return to the equilibrium decreases as either the BC decreases or the diameter increases because both the reduction in BC and increase in diameter result in the increase in the lacrimal layer thickness between the lens and cornea increase which yielded the lowering of the viscous friction in the lens motion. As the edge angle of tight fitted lens increases the time for recentering decreases due to the increase in restoring force without change in lacrimal thickness beneath the lens. In the case of flat fitted hard lens (RGP included), the lacrimal layer thickness under the lens increases as either BC or diameter increases which results in reduction in viscous friction so that the time for the lens's return to the equilibrium were to decrease. The edge angle of flat fitted lens does not affect the lens motion. Conclusions: The effect of BCs on the lens motion (time to approach the equilibrium) was concluded to be significant with both tight and flat fitted lens where its results are contrary with each other. The edge angle of lens only affects the motion in tight fitted lenses.

  • PDF

Change of Corneal Shape with Soft Contact Lens Type (소프트콘택트렌즈의 유형에 따른 각막형태의 변화)

  • Woo, Chul-Min;Lee, Hyun Mee
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.19 no.1
    • /
    • pp.111-120
    • /
    • 2014
  • Purpose: This study was to investigate changes in the thickness of cornea, curvature of cornea, and aberration depending on the water contents, materials, and refractive power of contact lens. Methods: The differences in the corneal thickness between pre- and post-wearing the lenses were compared using 5 kinds of lenses. The changes in the corneal thickness, the curvatures of the anterior and posterior cornea, and high order aberration (HOA) before and after wearing the lenses were investigated at the center of the cornea, and the different distance and the direction away from the center of the cornea. For the equipments of measurement, ORB ScanII (Bausch & Lomb Inc, ver 3.14) was used to measure the corneal topography and thickness, and Zywave (Bausch & Lomb Inc, ver 5.20) was used to analyze the high order aberration. Results: Five (S1, S2, S3, T1, T2) of the lens was used for this study, excluding the lens T2 lens has four lenses and the thickness of the corneal shape, but the impact is minimal. In the case of the hydrogel soft contact lenses (T2 lens) with low oxygen permeability, the corneal thickness showed distinct increasing patterns. The high order aberration and coma aberration were most changed in the silicon hydrogel toric lens, while the depth of anterior was most changed in the hydrogel toric lens. Conclusion: Among the 5 kinds of contact lenses with different water contents, materials, and refractive power used for this study, the corneal shape change was small for the lenses with an oxygen permeability (Dk) of more than 28, and the largest for the lenses with a very low oxygen permeability.

A Study for an Analytic Conversion between Equivalent Lenses (등가렌즈의 해석적인 변환방법에 대한 연구)

  • Lee, Jong Ung
    • Korean Journal of Optics and Photonics
    • /
    • v.23 no.1
    • /
    • pp.17-22
    • /
    • 2012
  • An equivalent lens is a lens which has the same total power of refraction and the same paraxial imaging characteristics for the marginal rays as another lens, but has a different axial thickness. In this study, an analytic lens conversion from a thick lens to its equivalent lens is investigated, then it is shown that the equivalent lens is a solution of a quadratic equation. Every thick lens corresponds to one of two real roots of this quadratic equation. Therefore, except in the case of a unique solution, the equation has a conjugate solution, the other of the two roots. The conjugate solution has the same axial thickness, power, and paraxial imaging characteristics, but it has different shape and aberration characteristics. The characteristics of an equivalent lens and its conjugate solution are examined by using a sample lens.

Color soft contact lens and corneal thickness

  • Kim, Douk-Hoon
    • Journal of Korean Clinical Health Science
    • /
    • v.7 no.1
    • /
    • pp.1205-1214
    • /
    • 2019
  • Purpose: To investigate the effect of color soft contact lenses on the corneal thickness in young Korean population. Methods: The subjects consisted of 112 eyes (7 males, 49 females) with the mean age of $20.987{\pm}1.093years$ (range 20-25 years) in young Korean population during 2018. Test was compared the corneal thickness before and after wearing color soft contact lenses. The thinnest cornea thickness(TCT), central cornea thickness(CCT), pupil centre thickness(PCT), superior corneal thickness(SCT),inferior corneal thickness(ICT), medial corneal thickness(MCT), lateral corneal thickness(LCT) of the cornea was measured using the Pentacam pachymetry. The statistically analysis was perform the Shaparo-Wilk test. Results: The right eye was a statistically significant among the CCT,LCT, MCT and TCT values(p<0.001) in the compared the corneal thickness before and after wearing soft colour contact lenses. Also the left eye was a statistically significant among the LCT and MCT values(p<0.001) in the compared the corneal thickness before and after wearing soft colour contact lenses. However, there was no statistical difference (p>0.5) in the mean PCT between before and after wearing color soft contact lenses. Conclusion: These results suggested that the color soft contact lens wear can the effect the regional thickness of cornea. Therefore, the analysis of corneal topography with Pentacam can provide correct and useful diagnostic information of the morphology of the RGP contact lens fitting and diagnosis of corneal refraction surgery.

The beam property simulation for the fabrication of a MLA(Micro Lens Array) (MLA(Micro Lens Array) 제작을 위한 광학 시뮬레이션)

  • Oh, Hae-Kwan;Seo, Hyun-Woo;Kim, Geun-Young;Wei, Chang-Hyun;Song, Yo-Tak;Lee, Kee-Keun;Yang, Sang-Sik
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.1497_1498
    • /
    • 2009
  • This paper presents the simulation of micro-lens arrays based on dry and wet etching technique. Code V (Optical Research Associates Ltd) simulation was performed to extract optimal design parameters of a Micro-Lens Array(MLA). Thickness of UV adhesive, wavelength of laser source, curvature, and shape of lens surface were chosen for the design parameters. The simulation results showed that focal length of a MLA decreased with the increase of UV adhesive thickness. And the focal length depended on shape of lens surface and length of laser source.

  • PDF

Correlation of Refractive Error, Axial Length, Chamber Depth, Lens Thickness and Corneal Thickness of Normal University Students (정상 대학생의 눈 굴절이상, 안축장, 전방깊이, 수정체두께 그리고 각막두께의 연관성)

  • Kim, Chang-Sik;Lee, Hak-Jun
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.13 no.1
    • /
    • pp.89-94
    • /
    • 2008
  • Purpose: To make a comparative study of correlation between biometry data of size in eyeball and refractive error. Methods: The subjects were 68 normal university students (male 36, female 32) and the average age was 22.85${\pm}$3.12. We measured the students' eyesight by A-scan ultrasound and refractor. The results were examined it's statistical significance by SPSS 12.0 version. Results: The mean of axial length was 24.31${\pm}$1.24 mm, chamber depth was 3.48${\pm}$0.28 mm, lens thickness was 3.56${\pm}$0.26 mm and corneal thickness was 0.55${\pm}$0.03 mm. Male's Axial length and chamber depth were larger than female's. As reflective error decreases the thickness of lens become thicker. The measurement data between right eye and left eye didn't had difference and there was no correlation with result of T-test. There were statistically significant correlation with length and chamber depth, axial length and corneal thickness, chamber depth and corneal thickness, and refractive error and lens thickness (p<0.01). Refractive error and axial length were minus linear regression (r=-0.56). Conclusions: Eye's refractive error was changed by axial length, chamber depth and lens thickness but it wasn't related with sex and whether it is a right eye or a left eye.

  • PDF