• 제목/요약/키워드: thickness modes

검색결과 392건 처리시간 0.026초

초음파 모터용 람다형 다방향 변환자 (Multi-directionally Movable Lambda Shape Transducer for Ultrasonic Motor)

  • 도영수;남효덕;김영덕
    • 한국전기전자재료학회논문지
    • /
    • 제21권2호
    • /
    • pp.131-136
    • /
    • 2008
  • The transducer for multi-directionally movable ultrasonic motor having lambda shaped vibrators has been proposed and designed. The two branches cross at a right angle with each other at the tip. FEM analyses of lambda shaped transducer were carried out to find vibration modes for ultrasonic motor. The lambda shaped transducer has one symmetric mode and two anti-symmetric modes. The symmetric mode generates the normal direction motion of the tip. The lateral and vertical direction motion of the tip are excited by two anti-symmetric modes. The normal and lateral direction motions made an lateral elliptic trajectory. And the normal and vertical direction motions made an vertical elliptic trajectory normal to previous one. The transducer with 1 mm in thickness and 25 mm in length has been fabricated and evaluated. The resonance frequencies of the transducer was 32 kHz and 103 kHz. The tangential and vertical vibration displacement of the transducer having the lateral elliptic trajectory were $1.5{\mu}m\;and\;1.1{\mu}m$, respectively at the driving voltage of 100 Vpp and frequency of 32 kHz and 103 kHz. And the tangential and vertical vibration displacement of the transducer having the vertical elliptic trajectory were $0.4{\mu}m\;and\;0.2{\mu}m$, respectively at the same driving condition.

대향류 확산화염의 소염특성에 미치는 직류전기장의 영향에 관한 실험적 연구 (Experimental Study on the Effect of DC Electric Field on Extinction Characteristics of Counterflow Diffusion Flame)

  • 박익형;김민국;원상희;차민석;정석호
    • 한국연소학회:학술대회논문집
    • /
    • 한국연소학회 2006년도 제33회 KOSCO SYMPOSIUM 논문집
    • /
    • pp.253-259
    • /
    • 2006
  • The effect of DC electric fields on the flame extinction was investigated experimentally in counterflow configurations for the methane/oxygen/nitrogen diffusion flame. The electric fields was applied by connecting the high voltage and ground terminals to the upper and lower burners, respectively. In case of having electric fields, several modes of flame extinction was observed according to the electric field intensity and strain rate defined by the exit velocity. To visualize and characterize the flame structure and intensity, planar LIF technique was adopted for OH radicals. Consequently, several length scales, including the flame width, thickness, and height from the burner tip, were introduced to explain the various flame behaviors and to characterize the flame extinctions. It was found that the variation of flame width and the chemical reaction are strongly related to a critical electric field intensity, thus the various modes of diffusion flame extinction could be observed due to the electric fields.

  • PDF

헤드라이너를 포함한 승용차의 차실의 음향모드 특성 (Acoustic Modal Property of a Vehicle Passenger Compartment including Head Liner)

  • 김석현;이진우
    • 산업기술연구
    • /
    • 제22권A호
    • /
    • pp.43-48
    • /
    • 2002
  • Acoustic modes of a vehicle compartment dominate the noise characteristics of the vehicle system in the low frequency range. Vehicle compartments have head liner and air gap of proper thickness to mount a interior lamp, as well as to have a good sound insulation and absorption performance. This study estimates the acoustic modal property of the medium size passenger car by experiment and by finite element analysis and also, investigates the effect of the head liner on the acoustic mode of the passenger compartment to obtain useful information for low noise compartment design.

  • PDF

Long Range Cylindrically Guided Ultrasonic Wave Technique for Inspection

  • Balasubramaniam, Krishnan
    • 비파괴검사학회지
    • /
    • 제23권4호
    • /
    • pp.364-371
    • /
    • 2003
  • In this paper, a review of the current status, on the use of long range cylindrically guided wave modes, and their interaction with cracks and corrosion damage in pipe-like structures will be discussed. Applications of cylindrically guided ultrasonic wave modes have been developed for inspection of corrosion damage in pipelines at chemical plants, flow-accelerated corrosion damage (wall thinning) in feedwater piping, and circumferential stress corrosion cracks in PWR steam generator tubes. It has been demonstrated that this inspection technique can be employed on a variety of piping geometries (diameters from 1 in. to 3 ft, and wall thickness from 0.1 to 6 in.) and a propagation distance of 100 meters or more is sometimes feasible. This technique can also be used in the inspection of inaccessible or buried regions of pipes and tubes.

유연보의 과도 진동 감쇠를 위한 점탄성 재료의 최적 분포 (Optimal Distribution of Viscoelastic Material for Transient Vibration Suppression of a Flexible Beam)

  • 김태우;김지환
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2002년도 추계학술대회논문집
    • /
    • pp.605-610
    • /
    • 2002
  • Eigenvalues are taken as performance criteria for structural damping design using viscoelastic material. Given material properties, optimal distribution of damping material is sought based on eigenvalue sensitivity. For eigenanalysis of frequency dependent viscoelastic material treated structures, Golla-Mushes-McTavish (GHM) model is used and some dominant modes are chosen for consideration. To avoid the intensity of computation caused by increased problem size, an alternative approximate method is proposed which uses elastic modes and can be applied under small damping assumption. A cantilever beam treated with unconstrained viscoelastic layer is tested and optimal distribution of thickness of the layer is illustrated. Partial coverage configurations are compared with the one-sided full coverage case.

  • PDF

초음속 공기장에서 Bluff-Body를 이용한 안정화염의 특성과 구조 (The Characteristic Modes and Structures of Bluff-Body Stabilized Flames in Supersonic Coflow Air)

  • 김지호;윤영빈
    • 한국연소학회:학술대회논문집
    • /
    • 한국연소학회 2002년도 제24회 KOSCO SYMPOSIUM 논문집
    • /
    • pp.147-153
    • /
    • 2002
  • Experimental investigations are performed on the stability and the structure of bluff-body stabilized hydrogen flames. The velocities of coflow air are varied from subsonic to supersonic velocity of Mach 1.8 and OH PLIF images and Schilieren images are used for analysis. Three characteristic flame modes are classified into three regimes with the variation of fuel-air velocity ratio; a jet like flame, a central-jet dominated flame and a recirculation zone flame. Stability curves are drawn to find the blowout regimes and to show that flame stability is improved by increasing the lip thickness of fuel nozzle that works as bluff-body. $Damk{\ddot{o}hler$ number is adopted in order to scale the blowout curves of each flame obtained at different sizes of the bluff-body and all blowout curves are scaled successfully regardless of its bluff-body size.

  • PDF

금속층이 포함된 측면 연마 광섬유 결합기의 편광 분리 특성 (Polarization splitting characteristics of the side-polished fiber coupler with a thin metal interlayer)

  • 김광택;황보승
    • 한국광학회지
    • /
    • 제13권3호
    • /
    • pp.228-234
    • /
    • 2002
  • 금속박막이 포함된 측면 연마 광섬유 결합기의 편광 선택적 결합 특성에 관한 이론적 연구 결과를 보고한다. 직교 모드이론을 이용하여 다양한 구조 조건에서 소자의 결합 특성을 분석하였다. 금속 박막의 두께가 증가함에 따라 TE 모드사이의 결합의 세기는 급격히 약해지는 반면에 TM 모드의 결합의 세기는 커짐을 보였다. 높은 편광 소멸비와 낮은 삽입 손실을 가지는 편광 분리기의 설계 조건을 제시하였다.

HDD 서스펜션의 모달 튜닝 (Modal Tuning of HDD suspension system)

  • 김동운;박영필
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2000년도 춘계학술대회논문집
    • /
    • pp.1583-1588
    • /
    • 2000
  • The dynamic characteristics of a HDD suspension system are investigated by finite element analysis and experimental modal analysis. A finite element model of the suspension Type850 was developed for unloaded case. The calculated vibration modes were compared with measurements and agree well in shape and frequency except some local modes. Local thickness and Young's modulus of the finite element model are updated by modal tuning method to develop the precise FE model. A sensitivity matrix of the natural frequencies for some design variables was calculated using finite difference method. Most natural frequencies calculated by the tuned FE model coincide with the measurements and the errors between them are less than 2%.

  • PDF

에어컨 홴 BLDC 전동기의 음향공진에 관한 연구 (Study on Acoustic Resonance of Air-conditioner Fan BLDC Motor)

  • 이홍주;권중학;이창민;황건용;황상문
    • 한국소음진동공학회논문집
    • /
    • 제19권9호
    • /
    • pp.863-869
    • /
    • 2009
  • Acoustic noises generated during motor operation in mechanical system are from electromagnetic, mechanical, aerodynamic and electrical sources. For identification of mechanical noise origins, misalignment, unbalance, fan shape, resonance, and vibration modes have been extensively considered to describe noise behavior. An experiment-based approach as well as a mathematical approach needs to be adopted for a realistic study into noise and vibration of the motor, because motor noise characteristics differ from type to type due to various noise sources. This paper analyzes noise characteristics of a brushless DC motor for air-conditioner fan, and proves that the test motor noise originates from acoustic modes of airspace in the motor. The motor noise sensitivity analysis by design of experiments reveals that the noise characteristics are closely related to switching frequency and frame thickness.

Nonlinear finite element modeling of steel-sheathed cold-formed steel shear walls

  • Borzoo, Shahin;Ghaderi, Seyed Rasoul Mir;Mohebi, Saeed;Rahimzadeh, Ali
    • Steel and Composite Structures
    • /
    • 제22권1호
    • /
    • pp.79-89
    • /
    • 2016
  • Cold formed steel shear panel is one of the main components to bearing lateral load in low and mid-rise cold formed steel structures. This paper uses finite element analysis to evaluate the stiffness, strength and failure mode at cold formed steel shear panels whit steel sheathing and nonlinear connections that are under monotonic loading. Two finite element models based on two experimental model whit different failure modes is constructed and verified. It includes analytical studies that investigate the effects of studs and steel sheathing thickness changes, fasteners spacing at panel edges, one or two sides steel sheathing and height-width ratio of wall on the lateral load capacity. Dominant failure modes include buckling of steel sheet, local buckling in boundary studs and sheet unzipping in the bottom half of the wall.