• Title/Summary/Keyword: thickness evaluation

Search Result 1,817, Processing Time 0.037 seconds

Evaluation of the Neural Fiber Tractography Associated with Aging in the Normal Corpus Callosum Using the Diffusion Tensor Imaging (DTI) (확산텐서영상(Diffusion Tensor Imaging)을 이용한 정상 뇌량에서의 연령대별 신경섬유로의 변화)

  • Im, In-Chul;Goo, Eun-Hoe;Lee, Jae-Seung
    • Journal of the Korean Society of Radiology
    • /
    • v.5 no.4
    • /
    • pp.189-194
    • /
    • 2011
  • This study used magnetic resonance diffusion tensor imaging (DTI) to quantitatively analyze the neural fiber tractography according to the age of normal corpus callosum and to evaluate of usefulness. The research was intended for the applicants of 60 persons that was in a good state of health with not brain or other disease. The test parameters were TR: 6650 ms, TE: 66 ms, FA: $90^{\circ}$, NEX: 2, thickness: 2 mm, no gap, FOV: 220 mm, b-value: $800s/mm^2$, sense factor: 2, acquisition matrix size: $2{\times}2{\times}2mm^3$, and the test time was 3 minutes 46 seconds. The evaluation method was constructed the color-cored FA map include to the skull vertex from the skull base in scan range. We set up the five ROI of corpus callosum of genu, anterior-mid body, posterior-mid body, isthmus, and splenium, tracking, respectively, and to quantitatively measured the length of neural fiber. As a result, the length of neural fiber, for the corpus callosum of genu was 20's: $61.8{\pm}6.8$, 30's: $63.9{\pm}3.8$, 40's: $65.5{\pm}6.4$, 50's: $57.8{\pm}6.0$, 60's: $58.9{\pm}4.5$, more than 70's: $54.1{\pm}8.1mm$, for the anterior-mid body was 20's: $54.8{\pm}8.8$, 30's: $58.5{\pm}7.9$, 40's: $54.8{\pm}7.8$, 50's: $56.1{\pm}10.2$, 60's: $48.5{\pm}6.2$, more than 70's: $48.6{\pm}8.3mm$, for the posterior-mid body was 20's: $72.7{\pm}9.1$, 30's: $61.6{\pm}9.1$, 40's: $60.9{\pm}10.5$, 50's: $61.4{\pm}11.7$, 60's: $54.9{\pm}10.0$, more than 70's: $53.1{\pm}10.5mm$, for the isthmus was 20's: $71.5{\pm}17.4$, 30's: $74.1{\pm}14.9$, 40's: $73.6{\pm}14.2$, 50's: $66.3{\pm}12.9$, 60's: $56.5{\pm}11.2$, more than 70's: $56.8{\pm}11.3mm$, and for the splenium was 20's: $82.6{\pm}6.8$, 30's: $86.9{\pm}6.4$, 40's: $83.1{\pm}7.1$, 50's: $81.5{\pm}7.4$, 60's: $78.6{\pm}6.0$, more than 70's: $80.55{\pm}8.6mm$. The length of neural fiber for normal corpus callosum were statistically significant in the genu(P=0.001), posterior-mid body(P=0.009), and istumus(P=0.012) of corpus callosum. In order of age, the length of neural fiber increased from 30s to 40s, as one grows older tended to decrease. For this reason, the nerve cells of brain could be confirmed through the neural fiber tractography to progress actively in middle age.

Color evaluation of low viscosity bulk-fill resin with composite resin capping layer (저점도 벌크필레진과 복합레진 적층수복물의 색조 평가)

  • Yun, Jonghyeon;Jung, Ji-Hye;Chang, Hoon-Sang
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.31 no.4
    • /
    • pp.294-300
    • /
    • 2015
  • Purpose: The purpose of this study was to measure the color of low viscosity bulk-fill resin with a capping layer and to compare it with the color of microhybrid composite resin. Materials and Methods: A low viscosity bulk-fill resin (SDR) and microhybrid composite resin of shade A2 (A2) or A3 (A3) were fabricated to 4 mm thickness and light cured for 20 seconds. CIE $L^*a^*b^*$ values of the resin specimens were measured with a colorimeter. Then shade A2 and A3 microhybrid composite resin was capped over low viscosity bulk-fill resins in 2 mm thickness (SA2, SA3). The resin specimens were light cured for 20 seconds and the color was measured and analyzed (n = 10). Color differences (${\Delta}E$) between SA2 and A2, SA3 and A3 were also calculated. Results: $L^*$ value was highest in SDR followed by SA2 and SA3. $L^*$ value of A2 and A3 was the lowest. $a^*$ value was lowest in SDR followed by SA2 and SA3, and A2 and A3 was the highest. $b^*$ value was lowest in SDR followed by A2 and SA2, and A3 and SA3 was the highest. ${\Delta}E$ between A2 and SA2 (${\Delta}E=3.4$), and that between A3 and SA3 (${\Delta}E=3.1$) was lower than the perceptible color difference threshold of ${\Delta}E=3.7$. Conclusion: ${\Delta}E$ between low viscosity bulk-fill resin with a capping layer and microhybrid resin was lower than the perceptible color difference threshold.

The Evaluation of Scattering Effects for Various Source Locations within a Phantom in Gamma Camera (감마카메라에서의 팬텀 내 선원 위치 변화에 따른 산란 영향 평가)

  • Yu, A-Ram;Lee, Young-Sub;Kim, Jin-Su;Kim, Kyeong-Min;Cheon, Gi-Jeong;Kim, Hee-Joung
    • Progress in Medical Physics
    • /
    • v.20 no.4
    • /
    • pp.216-224
    • /
    • 2009
  • $^{131}I$ is a radiological isotope being used widely for treatment of cancer as emitting gamma-ray and it is also applied to estimate the function of thyroid for its accumulation in thyroid. However, $^{131}I$ is more difficult to quantitate comapred to $^{99m}Tc$, because $^{131}I$ has multiple energy gamma-ray emissions compared to $^{99m}Tc$ which is a mono energetic gamma-ray source. Especially, scattered ray and septal penetration resulted by high energy gamma ray have a bad influence upon nuclear medicine image. The purpose of this study was to estimate scatter components depending on the different source locations within a phantom using Monte Carlo simulation (GATE). The simulation results were validated by comparing with the results of real experiments. Dual-head gamma camera (ECAM, Chicago, Illinois Siemens) with high energy, general-purpose, and parallel hole collimators (hole radius: 0.17 cm, septal thickness: 0.2 cm, length: 5.08 cm) was used in this experiment. The NaI crystal is $44.5{\times}59.1\;cm$ in height and width and 0.95 cm in thickness. The diameter and height of PMMA phantom were 16 cm and 15 cm, respectively. The images were acquired at 5 different locations of $^{131}I$ point source within the phantom and the images of $^{99m}Tc$ were also acquired for comparison purpose with low energy source. The simulation results indicated that the scattering was influenced by the location of source within a phantom. The scattering effects showed the same tendency in both simulation and actual experiment, and the results showed that the simulation was very adequate for further studies. The results supported that the simulation techniques may be used to generalize the scattering effects as a function of a point source location within a phantom.

  • PDF

Evaluation of Plasma D-dimer Concentration in Cats with Hypertrophic Cardiomyopathy (비대성 심근증이 있는 고양이에서 혈장 D-dimer 농도의 평가)

  • Kim, Tae-Young;Han, Suk-Hee;Choi, Ran;Hyun, Changbaig
    • Journal of Veterinary Clinics
    • /
    • v.31 no.2
    • /
    • pp.85-89
    • /
    • 2014
  • Arterial thromboembolism (ATE) is a common and fatal complication of hypertrophic cardiomyopathy (HCM) in cats. Therefore in this study, we evaluated the hypercoagulability (using plasma concentration of D-dimer) in HCM cats with different stage of heart failure and left atrial enlargement and also investigated the any correlation with echocardiographic indices (including left free wall thickness at diastole, interventricular septal thickness at diastole, LA to Ao ratio, heart failure stage, existence of systolic anterior motion of mitral valve). The median plasma D-dimer concentration in this study population was $0.51{\pm}0.70$ (range 0 to 2.50) ug/mL in the control group, $1.47{\pm}1.29$ (range 0.3 to 5.79) ug/mL in the HCM group, $1.48{\pm}1.65$ (range 0.3 to 5.79) ug/mL in the ISACHC I group, $1.62{\pm}0.4$ (range 1.31 to 2.07) ug/mL in the ISACHC II group, $1.36{\pm}0.91$ (range 0.3 to 2.31) ug/mL in the ISACHC III group, $1.90{\pm}1.60$ (range 0.3 to 5.79) ug/mL in the cat with LA dilation, $1.72{\pm}0.72$ (range 0.6 to 2.31) ug/mL in cats with SEC-T, $1.19{\pm}0.70$ (range 0.3 to 2.31) ug/mL in the cats with SAM, and $1.63{\pm}0.80$ (range 0.6 to 2.31) ug/mL in the cats with ATE. Our study found the median and mean concentration of plasma D-dimer was higher in cat with HCM, ATE, SECT and SAM and clearly provides evidence of hypercoagulability in cats with HCM, although the severity was not correlated to the dilation of LA and the presence of heart failure. This is the first study evaluating the hypercoagulability in cats with HCM in Korea.

Evaluation of Cerebral Aneurysm with High Resolution MR Angiography using Slice Interpolation Technique: Correlation wity Digital Subtraction Angiography(DSA) and MR Angiography(MRA) (Slice Interpolation기법의 고해상도 자기공명혈관조영술을 이용한 뇌동맥류의 진단 : 디지탈 감산 혈관조영술과 자기공명 혈관조영술의 비교)

  • ;;;Daisy Chien;Gerhard Laub
    • Investigative Magnetic Resonance Imaging
    • /
    • v.1 no.1
    • /
    • pp.94-102
    • /
    • 1997
  • Purpose: There have been some efforts to diagnose intracranial aneurysm through a non-invasive method using MRA, although the process may be difficult when the lesion is less than 3mm. The present study prospectively compares the results of high resolution, fast speed slice interpolation MRA and DSA thereby examing the potentiality of primary non-invasive screening test. Materials and Methods: A total of 26 cerebral aneurysm lesions from 14 patients with subarachnoid hemorrhage from ruptured aneurysm (RA) and 5 patients with unruptured aneurysm(UA). In all subjects, MRA was taken to confirm the vessel of origin, definition of aneurysm neck and the relationship of the aneurysm to nearby small vessels, and the results were compared with the results of DSA. The images were obtained with 1.5T superconductive machine (Vision, Siemens, Erlangen, Germany) on 4 slabs of MRA using slice interpolation. The settings include TR/TE/FA=30/6.4/25, matrix $160{\times}512$, FOV $150{\times}200$, 7minutes 42 seconds of scan time, effective thickness of 0.7 mm and an entire thickness of 102. 2mm. The images included structures from foramen magnum to A3 portion of anterior cerebral artery. MIP was used for the image analysis, and multiplanar reconstruction (MPR) technique was used in cases of intracranial aneurysm. Results: A total of 26 intracranial aneurysm lesions from 19 patients with 2 patients having 3 lesion, 3 patients having 2 lesions and the rest of 14 patients having 1 lesion each were examined. Among those, 14 were RA and 12 were UA. Eight lesions were less than 2mm in size, 9 lesions were 3-5mm, 7 were 6-9mm and 2 were larger than IOmm. On initial exams, 25 out of 26 aneurysm lesions were detected in either MRA or DSA showing 96% sensitivity. Specificity cannot be estimated since there was no true negative of false positive findings. When MRA and MPR were used concurrently for the confirmation of size and shape, the results were equivalent to those of DSA, while in the confirmation of aneurysm neck and parent vessels, the concurrent use of MRA and MPR was far superior to the sole use of either MRA or DSA. Conclusion: High resolution MRA using slice interpolation technique showed equal results as those of DSA for the detection of intracranial aneurysm, and may be used as a primary non-invasive screening test in the future.

  • PDF

Experimental Study on the Effect of Filter Layers on Pumping Capacity and Well Efficiency in an Unconfined Aquifer (자유면대수층에서 필터층이 취수량 및 우물효율에 미치는 영향에 대한 실험적 연구)

  • Song, Jae-Yong;Lee, Sang-Moo;Choi, Yong-Soo;Jeong, Gyo-Cheol
    • The Journal of Engineering Geology
    • /
    • v.27 no.4
    • /
    • pp.405-416
    • /
    • 2017
  • This study evaluated a model unconfined aquifer comprising a sand or gravel layer, a filter layer, a pumping well, and an observation well. The model was employed in step drawdown tests and then used to assess the permeability of each test tank. The optimal yield and well efficiency were then calculated. Evaluation of yield by step in sand layer filters of equal thickness gave optimized watering rates of 22.03 L/min in the double filter and 19.71 L/min in the single filter. The double filter's yield was 115.0% that of the single filter. A comparison of double and single filters, each 10 cm thick, showed the double filter to have a maximum yield of 182.7%. Yields for the gravel layer were 73.56 L/min for a double filter and 65.47 L/min for a single filter of the same thickness; the former value is 112.3% of that of the latter. Comparison of double and single filters with 10-cm-thick gravel layers revealed that the double filter had a maximum yield of 160.9%. Results for sand wells showed the double filter to have a maximum efficiency of 70.4% and the single filter to have a minimum efficiency of 37.1%. Gravel-layer well efficiencies were >66.5% for both double and single filters (each 30 cm thick), but only 22.5% for a 10-cm-thick single filter. This study confirms that permeability improved as the filter material became thicker; it also shows that a double filter has a higher yield and well efficiency than a single filter. These results can be applied to the practical design of wells.

Evaluation of the Efficiency of the Foxtail Millet Vacuum Cushion in Skin Cancer Radiation Treatment (자체 제작한 Foxtail Millet Vacuum Cushion의 광자선 피부암 치료 시 유용성 검증)

  • Choi, Shin-Cheol;Lee, Kyung-Jae;Jung, Sung-Min;Oh, Tae-Seong;Park, Jong-Il;Shin, Hyun-Kyo
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.24 no.2
    • /
    • pp.189-196
    • /
    • 2012
  • Purpose: The sufficiency of skin dose and the reemergence of patient set-up position to the success of skin cancer radiation treatment is a very important element. But the conventional methods to increase the skin dose were used to vacuum cushion, bolus and water tank have several weak points. For this reason, we producted Foxtail Millet Vacuum Cushion and evaluated the efficiency of the Foxtail Millet Vacuum Cushion in skin cancer Radiation treatment. Materials and Methods: We measured absolute dose for 3 materials (Foxtail Millet Vacuum Cushion, bolus and solid water phantom) and compared each dose distribution. We irradiated 6 MV 100 MU photon radiation to every material of 1 cm, 2 cm, 3 cm thickness at three times. We measured absolute dose and compared dose distribution. Finally we inspected the CT simulation and radiation therapy planing using the Foxtail Millet Vacuum Cushion. Results: Absolute dose of Foxtail Millet Vacuum Cushion was similar to absolute dose of bolus and solid water phantom's result in each thickness. it Showed only the difference of 0.1~0.2% between each material. Also the same result in dose distribution comparison. About 97% of the dose distribution was within the margin of error in the prescribed ranges ($100{\pm}3%$), and achieved the enough skin dose (Gross Tumor Volume dose : $100{\pm}5%$) in radiation therapy planing. Conclusion: We evaluated important fact that Foxtail Millet Vacuum Cushion is no shortage of time to replace the soft tissue equivalent material and normal vacuum cushion at the low energy radiation transmittance. Foxtail Millet Vacuum Cushion can simultaneously achieve the enough skin dose in radiation therapy planing with maintaining normal vacuum cushion' function. Therefore as above We think that Foxtail Millet Vacuum Cushion is very useful in skin cancer radiation treatment.

  • PDF

Evaluation of Retro recon for SRS planning correction according to the error of recognize to coordinate (SRS의 좌표 인식 오류 시 Retro recon을 이용한 수정 방법에 관한 평가)

  • Moon, hyeon seok;Jeong, deok yang;Do, gyeong min;Lee, yeong cheol;Kim, sun myung;Kim, young bum
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.28 no.2
    • /
    • pp.101-108
    • /
    • 2016
  • Purpose : The purpose of this study was to evaluate the Retro recon in SRS planning using BranLAB when stereotactic location error occurs by metal artifact. Materials and Methods : By CT simulator, image were acquired from head phantom(CIRS, PTW, USA). To observe stereotactic location recognizing and beam hardening, CT image were approved by SRS planning system(BrainLAB, Feldkirchen, Germany). In addition, we compared acquisition image(1.25mm slice thickness) and Retro recon image(using for 2.5 mm, 5mm slice thickness). To evaluate these three images quality, the test were performed by AAPM phantom study. In patient, it was verified stereotactic location error. Results : All the location recognizing error did not occur in scanned image of phantom. AAPM phantom scan images all showed the same trend. Contrast resolution and Spatial resolution are under 6.4 mm, 1.0 mm. In case of noise and uniformity, under 11, 5 of HU were measured. In patient, the stereotactic location error was not occurred at reconstructive image. Conclusion : For BrainLAB planning, using Retro recon were corrected stereotactic error at beam hardening. Retro recon may be the preferred modality for radiation treatment planning and approving image quality.

  • PDF

Pathology of the Rotator Cuff in Adhesive Capsulitis Patients (견관절 유착성 관절 낭염 환자에 동반된 회전근 개 병변)

  • Yoo, Jae-Chul;Ahn, Jin-Hwan;Kim, Jae-Hoon;Chang, Moon-Jong;Seo, Hee-Soo;Sul, Eun-Jin
    • Journal of the Korean Arthroscopy Society
    • /
    • v.11 no.1
    • /
    • pp.24-31
    • /
    • 2007
  • Purpose: To evaluate any combined rotator cuff pathologies in adhesive capsulitis patients with magnetic resonance arthrography (MRA) or ultrasonography (USG), and to see any differences in findings between MRA and USG. Materials and Methods: From June to December 2005, 80 consecutive patients with adhesive capsulitis were prospectively evaluated with either MRA or USG. Two groups were randomly assigned for examination. Evaluation were focused on any combined rotator cuff pathologies especially supraspinatus tendon. Results: Small (less than 1 cm) full-thickness SSP tendon tear were seen in 6 patients (MRA 4, USG 2, 8%) and partial-thickness SSP tendon tears in 21 (MRA 12, USG 9, 26%). In addition, supraspinatus tendinopathy were seen in 15 patients (MRA 7, USG 8, 19%). Overall, various SSP pathologies were reported in 42 patients (53%) of the study objects (MRA 23, 68% and USG 19, 41%). Subscapularis tendon partial tears were reported in 9 patients (MRA 6, USG 3, 11%). There were no statistical differences of the findings between MRA and USG in detecting rotator cuff pathologies (p>0.5). Conclusion: Nearly one half of the adhesive capsulitis patients showed various supraspinatus tendon pathology in MRA or USG. Although MRA group showed slight higher percentage of associated rotator cuff pathology than USG group (without statistical significance), this could be attributed to better resolution capacity of MRA than USG.

  • PDF

A study on dose attenuation in bone density when TBI using diode detector and TLD (전신방사선조사(TBI)시 다이오드 측정기(Diode detector) 및 열형광선량계(TLD)를 이용한 골조직 선량감쇄에 대한 고찰)

  • IM Hyun Sil;Lee Jung Jin;Jang Ahn Ki;Kim Wan Seon
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.15 no.1
    • /
    • pp.67-77
    • /
    • 2003
  • I. Purpose Uniform dose distribution of the whole body is essential factor for the total body irradiation(TBI). In order to achieved this goal, we used to compensation filter to compensate body contour irregularity and thickness differences. But we can not compensate components of body, namely lung or bone. The purpose of this study is evaluation of dose attenuation in bone tissue when TBI using diode detectors and TLD system. II. Materials and Methods The object of this study were 5 patients who undergo TBI at our hospital. Dosimetry system were diode detectors and TLD system. Treatment method was bilateral and delivered 10MV X-ray from linear accelerator. Measurement points were head, neck, pelvis, knees and ankles. TLD used two patients and diode detectors used three patients. III. Results Results are as followed. All measured dose value were normalized skin dose. TLD dosimetry : Measured skin dose of head, neck, pelvis, knees and ankles were $92.78{\pm}3.3,\;104.34{\pm}2.3,\;98.03{\pm}1.4,\;99.9{\pm}2.53,\;98.17{\pm}0.56$ respectably. Measured mid-depth dose of pelvis, knees and ankles were $86{\pm}1.82,\;93.24{\pm}2.53,\;91.50{\pm}2.84$ respectably. There were $6.67\%{\sim}11.65\%$ dose attenuation at mid-depth in pelvis, knees and ankles. Diode detector : Measured skin dose of head, neck, pelvis, knees and ankles were $95.23{\pm}1.18,\;98.33{\pm}0.6,\;93.5{\pm}1.5,\;87.3{\pm}1.5,\;86.90{\pm}1.16$ respectably. There were $4.53\%{\sim}12.6\%$ dose attenuation at mid-depth in pelvis, knees and ankles. IV. Conclusion We concluded that dose measurement with TLD or diode detector was inevitable when TBI treatment. Considered dose attenuation in bone tissue, We must have adequately deduction of compensator thickness that body portion involved bone tissue.

  • PDF