• Title/Summary/Keyword: thickness changes

Search Result 1,707, Processing Time 0.032 seconds

The Effect of Thicknesses on Magnetic Properties of Fe-Hf-N Soft Magnetic Thin Films (Fe-Hf-N 연자성 박막의 자기적 특성에 미치는 박막 두께의 영향)

  • Choi, Jong-Won;Kang, Kae-Myung
    • Journal of the Korean institute of surface engineering
    • /
    • v.44 no.6
    • /
    • pp.255-259
    • /
    • 2011
  • The thickness dependence of magnetic properties was experimentally investigated in nanocrystalline Fe-Hf-N thin films fabricated by a RF magnetron sputtering method. In order to investigate the thickness effect on their magnetic properties, the films are prepared with different thickness ranges from 90 nm to 330 nm. It was revealed that the coercivity of the thin film increased with film thickness. On the contrary, the saturation magnetization decreased with film thickness. On the basis of the SEM and TEM, an amorphous phase forms during initial growth stage and it changes to crystalline structure after heat treatment at $550^{\circ}C$. Nanocrystalline Fe-Hf-N particles are also generated.

The Research via Linear of Tantalum Thin Film Thickness Depending on Revolution Velocity of Spin Coater (스핀코터 회전속도에 따른 탄탈륨 박막두께의 선형모델에 관한 연구)

  • Kim, Seung Wook
    • Journal of the Semiconductor & Display Technology
    • /
    • v.19 no.1
    • /
    • pp.17-22
    • /
    • 2020
  • Recently, the decrease in thin film thickness has been actively studied by changing several physical elements such as the increase in revolution velocity of lower substrate equipped with AC or DC motor. In this paper, we propose a novel spin coater control system that changes AC or DC motor and common use software with limitation of velocity and position control into step motor and LABVIEW software based on GUI to control revolution velocity and position more precisely. By determining six input values of rotation velocity 1, 5, 10, 25, 50, 100 PPS, we fabricated six samples using coating target, TA(tantalum) on silicon substrate and measured their thin film thickness by SEM. Hence, this research can be applied to inferring thin film thickness of tantalum regarding any value of revolution velocity without additional experiments and for linear reference model via property analysis of thin film thickness using other thin-film materials.

The Effect on the growth of landscaping trees by fixed trampling in brick paved under-surface soil physical properties -Sand bed's thickness & prticle size were setted by experimental variable factors (일정 답압시 보도블럭포장재 하부 토양물리성의 변화가 조경수 생육에 미치는 영향 - 포설모레 두께 및 립경을 실험변이 인자로 설정하여 -)

  • 조재현
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.25 no.2
    • /
    • pp.94-103
    • /
    • 1997
  • The purpose of this study is to find out the effects of brick paved under-surface soil physical properties which are changed by fixed trampling. Thus, a sandy loam which is known as a profitable soil for plants is used an experimental soil to study the changes of the soil physical properties. It is related to sand bed's thickness & particle size which are settled by experimental variable factors. According to the variation of sand bed's particle size, bulk density and soil hardness at natural dryed soilcondition result in 0.075~2.00mm>2.00~5.00mm>2.00~8.00mm>5.00~8.00mm, and water content at natural dryed soil condition are observed being insensible change rate from the point that sand thickness is 30~40mm and more sand bed's thickness constructed by the variation of sand bed's thickness.

  • PDF

The Effect of Carbonate Particle Size Distributions on the Thickness Change of MCFC Electrolyte Matrix (전해질 입자크기에 따른 용융탄산염 연료전지 전해질 지지체의 두께변화에 관한 연구)

  • 이형근;김남진;이덕열
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.11 no.5
    • /
    • pp.384-393
    • /
    • 1998
  • A mixed powder of electrolyte and matrix support materials with a proper proportion was used for the fabrication of an electrolyte matrix sheet. The purpose of this study is to reduce the large change in MCFC cell thickness occurring in the initial start-up period when separate sheets of electrolyte and support are used. A focus was put on how small the carbonate particles could be made. The particle size of the carbonate powder was controlled by ball milling and the distribution was measured using a particle size analyser. The thickness change was reduced to 20% by this approach, which could be compared to 27% observed in a conventional cell. The thickness changes of electrolyte matrix have linear relation sizes of carbonate powders.

  • PDF

SOFT TISSUE CHANGES FOLLOWING BIMAXILLARY SURGERY IN SKELETAL CLASS III MALOCCLUSION PATIENTS (골격성 III급 부정교합 환자에서 양악 수술후 연조직 변화에 대한 연구)

  • Park, Hong-Ju;Choi, Hong-Ran;Ryu, Sun-Youl
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.20 no.4
    • /
    • pp.284-290
    • /
    • 1998
  • The purpose of this study was to assess the soft tissue changes using twenty skeletal class III malocclusion patients who treated with bimaxillary surgery for the correction of dentofacial deformities. Patients were divided into two groups. One was impaction and advancement of maxilla with mandibular set-back (Group 1), the other was downward and advancement of maxilla with mandibular set-back (Group 2). Preoperative and postoperative one year cephalometric data were analyzed and compared. Results obtained were as follows: 1. The ratio of horizontal changes of soft tissue to hard tissue at Nt to ANS, Ls to UI, Li to LI, sPog to Pog were 1:0.60, 1:0.79, 1:0.47, 1:0.63 in group 1 respectively, and 1:0.59, 1:0.48, 1:0.83, 1:1.09 in group 2 respectively. Soft tissue changes were highly predictable at the upper lip, lower lip, and chin area. 2. The ratio of vertical changes of soft tissue to hard tissue at Nt to ANS, Li to LI were 1:0.72, 1:0.06 in group 1, and others showed no statistically significant difference. 3. The ratio of horizontal changes of Ls to hard tissue movements at LI(h) was 1:-0.82 in group 1 and at UI(h), LI(h) were 1:0.48, 1:0.01 in group 2. These ratios of group 1 were greater than those of group 2. 4. The direction of horizontal change of Li was the same as that of hard tissue change. The ratio of horizontal changes of Li to LI was 1:0.47 in group 1 and others showed no statistically significant difference. 5. The changes of upper lip thickness and length were -1.6mm, -1.4mm in group 1, and -1mm, -2.7mm in group 2. 6. The ratios of thickness of upper lip to ANS, UI, LI were 1:-0.83, 1:-0.37, 1:0.11 in group 1. There was similar trend in group 2, and there were no statistically significant difference. These results suggest that prediction of changes in soft tissue of upper lip, lower lip, and chin were 79%, 47%, and 63% in group 1, and 48%, 83%, and 109% in group 2. There was a tendency to decrease in thickness and increase in length of the upper lip.

  • PDF

HARD AND SOFT TISSUE CHANCES AFTER ORTHOGNATHIC SURGERY OF MANDIBULAR PROGNATHISM (하악전돌증 환자의 악교정 수술후 경조직과 연조직 변화에 관한 두부방사선 계측학적 연구)

  • Choe, Yoo-Kyung;Suhr, Cheong-Hoon
    • The korean journal of orthodontics
    • /
    • v.23 no.4 s.43
    • /
    • pp.707-724
    • /
    • 1993
  • The purpose of the study is to estimate hard and soft tissue changes after orthognathic surgery for the correction of the mandibular prognathism and to describe interrelationship and ratios of soft and hard tissue changes. The presurgical and postsurgical lateral cephalograms of 31 treated patients(17 males and 14 females) was used ; these patients had received combined orthodontic-surgical treatment by means of a bilateral sagittal split ramus osteotomy. Their ages ranged from 16 to 31 years and mean age was 21.4 years. A computerized cephalometric appraisal was developed and used to analyse linear and angular changes of skeletal and soft tissue profile. The statistical elaboration of the data was made by means of $SPSS/PC^+$. The results of the study were as follows : 1. The correlations of soft and hard tissue horizontal changes were significantly high and the ratios were $97\%$ at LI, $107\%$ at ILS, and $93\%$ at Pog'. 2. The correlations of vertical changes at Stm, LI and horizontal changes at Pog were high$(26\%)$ and at the other areas were not statistically high. 3. The correlations of soft ad hard tissue vertical changes were not significantly high in all areas except Gn' $(30\%)$ and Me' $(56\%)$. 4. The soft tissue thickness was significantly decreased in upper lip and increased in lower lip, and the amount of changes after surgery was reversely correlated with initial thickness. 5. The facial convexity was increased and relative protrusion of upper lip was increased and that of lower lip was decreased. 6. The upper to lower facial height(Gl-Sn/Sn-Me') was increased and upper to lower jaw height(Sn-Stms/Stmi-Me') was increased.

  • PDF

Properties of the Gold and Palladium-Nickel Alloy Plated Layers on Electrical Contact Materials (접점상에 입힌 Au 및 Pd-Ni 합금도금층의 특성)

  • 백철승;장현구;김회정
    • Journal of the Korean institute of surface engineering
    • /
    • v.25 no.3
    • /
    • pp.107-116
    • /
    • 1992
  • The optimum thickness of Pd-Ni plated layers used as an electrical contact film was investigated by evaluating mechanical, thermal and environmental characteristics. The variations of morphologies and chemical compositions were studied by using SEM, EDS and ESCA. As a result of wear test, the wear resistance behavior of the gold plated layers was not changed with the sliding velocity changes. The palladium-nickel plated layer showed better wear resistance than the gold plated layer at low sliding velocity, but it showed poor wear resistance at high sliding velocity. Under the thermal condition of $400^{\circ}C$ in air, the gold thickness of $2\mu\textrm{m}$ without underplate on phosphorous bronze formed copper oxide on the surface layer by rapid diffusion of copper whereas the gold thickness of $0.8\mu\textrm{m}$ deposited on nickel and palladium-nickel underplate was stable at $400^{\circ}C$. Under the sulfur dioxide environments, the gold thickness of $0.3\mu\textrm{m}$ deposited on the nickel thickness of$ 3\mu\textrm{m}$ and the palladium-nickel thickness of $2\mu\textrm{m}$ underplate was more corrosion-resistant than the gold thickness of $2\mu\textrm{m}$ without underplate on phosphorous bronze. Under the nitric acid vapor environment, corrosion resistance of the gold film was superior to an equivalent thickness of the palladium-nickel film.

  • PDF

HARDNESS CHANGE OF LIGHT-ACTIVATED GLASS IONMER CEMENT WITH THICKNESS AND TIME (광경화형 글래스아이오노머 시멘트의 두께 및 시간경과에 따른 경도의 변화)

  • Lee, Kyoung-Jin;Oh, Won-Mann;Kim, Sun-Hun
    • Restorative Dentistry and Endodontics
    • /
    • v.20 no.1
    • /
    • pp.303-315
    • /
    • 1995
  • An adequate and homogeneous cure of light-activated restroative material is very important for improvement of marginal adaptation and prevention of marginal leakage, secondary caries and pulpal irritation as well as expressing natural physical property of that material. The purpose of this study was to evaluate the change of surface hardness and cure uniformity of light-activated glass ionomer cements. Restorative(Fuji II LC, Vitremer) and lining(Baseline VLC, Vitrebond) light-activated glass ionomer cements were investigated for this study. The surface hardness of the top and bottom surfaces and cure uniformity of each 1mm, 1.5mm, 2mm, 2.5mm & 3mm in the thickness of specimen were measured immediately, at 1 hour, 24 hours and 1 week after light activation. The surface hardness change and cure uniformity of all the specimens were measured by Knoop hardness tester. The results were as follows. 1. The surface hardness of top and bottom surfaces in all groups increased with time(p<0.01). 2. Both top and bottom surfaces hardness of Vitrebond group measured immediately after light-activation were significantly lower than those of the other groups(p<0.01). 3. The surface hardness of top and bottom surfaces of restorative light -activated glass ionomer cements was higher than those of lining materials at 1 week(p<0.10). 4. Surface hardness of Vitremer group decreased as the specimen thickness increased, except top and bottom surfaces hardness of the specimen at 1 week(p<0.01). There was no significant difference in the surface hardness of Fuji II LC with changes in the thickness except bottom surface hardness of specimen at 24 hours and 1 week (p>0.05). 5. Surface hardness of Vitrebond group significantly decreased as the specimen thickness increased(p<0.01). There was no significant difference in the surface hardness of Baseline VLC group with changes in the thickness except bottom surface hardness of specimen measured immediately after light -activation(p>0.05). 6. The hardness ratio of top against bottom surface in all groups decreased with time(p<0.05). 7. There was no significant difference in the hardness ratio of top against bottom surface with changes of the thickness except Vitrebond group, 24 hours and 1 week of Vitremer group and 1 week of Baseline VLC group (p>0.05). These results suggest that surface hardness of restorative ligh-activated glass ionomer cements were highter than those of lining light-activated materials. In all groups, the surface hardness and cure uniformity continuously increased with time.

  • PDF

A CEPHALOMETRIC STUDY OF SOFT TISSUE PROFILE CHANGES ASSOCIATED WITH ORTHODONTIC TREATMENT (Cephalogram 분절(分折)에 의(依)한 부정교합자(不正咬合者) 치료전후(治療前後)의 연조직(軟組織) 측모(側貌) 변화(變化)에 관(關)한 연구(硏究))

  • Park, Young Guk;Lee, Ki Soo
    • The korean journal of orthodontics
    • /
    • v.14 no.1
    • /
    • pp.103-113
    • /
    • 1984
  • This work was undertaken to evaluate the integumental response in lower face to hard tissue changes, and to grope the prediction equation for expected integumental profile changes. Cephalometric headplates of 25 persons consisted of 8 Angle's class 1 maxillary protrusive and 17 Angle's class II division 1 patients whose mean age was 15.2 years were traced, diagramatized, and statistically analyzed. The results were as follows; 1. Upper incisor and lips were retracted and convexity of integumental profile decreased concurrently with decrease of hard tissue procumbency, however soft tissue point A', B', and Pog' did not undergo significant changes after orthodontic treatment. 2. Remarkable increment of upper lip thickness and upper lip height was shown and this was related to upper incisor retraction. The ratio between the amount of upper incisor retraction and the increment o f upper lip thickness was approximately 1.16:1. 3. Moderate correlation of upper lip retraction to upper incisor retraction, and of lower lip retraction to lower incisor movement were arranged, and yet comparatively wide variability from subject to subject was shown. 4. It was possible to predict statistically for horizontal alteration of lip position and change of upper lip angulation ground in orthodontic treatment.

  • PDF

THE EFFECTS OF DIABETES ON THE RAT PAROTID GLAND (당뇨병이 백서의 이하선에 미치는 영향에 관한 실험적 연구)

  • Park Chull-Jea;Hwang Eui-Hwan;Lee Sang-Rae
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.26 no.2
    • /
    • pp.75-90
    • /
    • 1996
  • The purpose of this study was to observe microscopic change of salivary gland tissue, which is a cause of xerostomia in diabetic condition; for this target, the author injected streptozotocin 0.1ml/100 gm b.w. on the rat, Sprague Dawley, to induce diabetes, and then observed microscopic changes in parotid gland tissue using light microscopy and electron microscopy. The results were as follows : 1. Parotid gland tissue of the diabetic rat was atrophied or degenerated in lapse of experimental time, but began to repair from 14 days after diabetic induction. 2. In the basal lamina of the vessel of parotid gland tissue in the diabetic rat, lamina lucida was discontinued and lamina densa was increased in thickness, but the number of capillary was gradually increased and dilated. 3. In acinic and intercalated ductal cells of parotid gland in the diabetic rat, changes of mitochondria, RER, secretory granule, free ribosome were prominent. In conclusion, the present study demonstrated that degenerative changes of the parotid gland tissue were due to not completely thickening of the basal lamina of vessels, but many other causal factors, because thickness of the basal lamina of vessels was not related with degenerative changes.

  • PDF