• Title/Summary/Keyword: thickness changes

Search Result 1,690, Processing Time 0.033 seconds

Organic-layer thickness dependent optical properties of top emission organic light-eitting diodes (전면 유기 발광 소자의 유기물층 두께 변화에 따른 광학적 특성)

  • An, Hui-Chul;Joo, Hyun-Woo;Na, Su-Hwan;Kim, Tae-Wan;Hong, Jin-Woong;Oh, Yong-Cheul;Song, Min-Joung
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2008.06a
    • /
    • pp.413-414
    • /
    • 2008
  • We have studied an organic layer thickness dependent optical properties and microcavity effects for top-emission organic light-emitting diodes. Manufactured top emission device, structure is Al(100nm)ITPD(xnm)/$Alq_3$(ynm)/LiF(0.5nm)/Al(23nm). While a thickness of hole-transport layer of TPD was varied from 35 to 65nm, an emissive layer thickness of $Alq_3$ was varied from 50 to 100nm for two devices. A ratio of those two layers was kept to about 2:3. Variation of the layer thickness changes a traverse time of injected carriers across the organic layer, so that it may affect on the chance of probability of exciton formation. View-angle dependent emission spectra were measured for the optical measurements. Top-emission devices show that the emission peak wavelength shifts to longer wavelength as the organic layer thickness increases. For instance, it shifts from 490 to 555nm in the thickness range that we used. View-angle dependent emission spectra show that the emission intensity decreases as the view-angle increases. The organic layer thickness-dependent emission spectra show that the full width at half maximum decreases as the organic layer thickness increases. Top emission devices show that the full width at half maximum changes from 90 to 35nm as the organic layer thickness increases. In top-emission device, the microcavity effect is more vivid as the organic layer thickness increases.

  • PDF

The Use of Real-Time Ultrasound Imaging for Feedback during Abdominal Hollowing (복부 할로잉 운동에서 실시간 초음파 영상 피드백의 사용 효과)

  • Kwon, Nam-Hee;Lee, Hyun-Ok;Park, Du-Jin
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.6 no.3
    • /
    • pp.303-310
    • /
    • 2011
  • Purpose : This study examined the feedback effect of real-time ultrasound imaging on the thickness of transversus abdominis(TrA), internal abdominal oblique(IO) and external abdominal oblique(EO) during abdominal hollowing exercise(AHE) in crook lying. Methods : We performed this study on 30 healthy men who voluntarily consented to participate in this study after listening to its purpose and method. All subject were divided into an experimental group(n=15) with using the real-time ultrasound imaging feedback(RUIF) and a control group(n=15) without the RUIF The thickness changes between rest and AHE were compared between the two groups in crook lying. Results : The difference in TrA and EO thickness changes between the groups were significant in crook lying (p<0.05). Conclusion : The group with using real-time ultrasound imaging feedback showed a higher increase in the thickness of TrA than the other group without real-time ultrasound imaging feedback. And the thickness of EO in the group with using real-time ultrasound imaging feedback decreased than the other group without real-time ultrasound imaging feedback. If the muscle thickness can be regarded as an indicator of muscle activity, RUIF will be helpful for inducing the independent activity of TrA by reducing the activities of abdominal muscles such as EO.

Influence of Multi-directional Dynamic Stabilization Exercise on Thickness of Abdominal Muscles

  • Yu, Jae-Young;Park, Jea-Cheol;Jeong, Jin-Gyu
    • The Journal of Korean Physical Therapy
    • /
    • v.28 no.4
    • /
    • pp.249-253
    • /
    • 2016
  • Purpose: The purpose of this study was to examine the influence of multi-directional dynamic stabilization exercise on the thickness of the external oblique abdominis, internal oblique abdominis, and transversus abdominis. Methods: For the study subjects, 40 adults were taken and divided into two groups and stabilization exercise was performed for 6 weeks. Changes in muscle thickness during the pre-experimental period, and at 2 weeks, 4 weeks, and 6 weeks were analyzed using repeated ANOVA. Results: The thickness of the external oblique abdominis, internal oblique abdominis, and transversus abdominis in the multi-directional dynamic stabilization exercise group showed significant differences per period and an interaction was observed between period and group (p<0.01), while there were no significant differences in changes per group (p>0.05). Conclusion: The effects of multi-directional stabilization exercises on abdominal muscle thickness differed. The results presented herein can be utilized as basic data for future studies and in development of rehabilitation treatments.

Mode Characteristics Analysis of the SH-EMAT Waves for Evaluating the Thickness Reduction (두께감육 평가를 위한 SH-EMAT파의 모드특성 분석)

  • Park, I.K.;Kim, Y.K.
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.19 no.2
    • /
    • pp.198-203
    • /
    • 2010
  • In this paper, study on the mode characteristics analysis of the SH-EMAT (shear horizontal, electromagnetic acoustic transducer) waves for evaluating the thickness reduction in plates such as corrosion and friction is presented. Noncontact methods for ultrasonic wave generation and detection have been a great concern and highly demanded due to their capability of wave generation and reception on surface of high temperature or on rough surface. Mode identification of the SH-EMAT wave is carried out in an aluminum plate with thinning defects using time frequency analysis method such as wavelet transform, compared with theoretically calculated group velocity dispersion curve. The changes of various wave features such as the amplitude and the time-of-flight have been observed and the correlations with the thickness reduction have been investigated. Firstly, experiments have been conducted to confirm that it is possible to selectively generate and receive specific desired SH modes. These modes have then been analyzed to select the parameters that are sensitive to the thickness change. The results show that the mode cutoff and the time-of-flight changes are feasible as key parameters to evaluate the thickness reduction.

The Effects of Bridge Exercise with One Hip Joint Adduction on Trunk Muscle Thickness

  • Park, Jae-Cheol;Lee, Dong-Kyu
    • The Journal of Korean Physical Therapy
    • /
    • v.32 no.6
    • /
    • pp.354-358
    • /
    • 2020
  • Purpose: This study aimed to verify the effects of bridge exercise with resistance to one hip joint adductor muscle on the thickness of external and internal oblique abdominal muscles, transversus abdominis muscle, and erector spinae muscle. Methods: The subjects were divided into two exercise groups: 15 for Bridge Exercise Group (BEG) and 15 for One Hip joint Adduction Bridge Exercise Group (OHABEG). The study used an ultrasonic instrument to measure trunk muscle thickness. OHABEG performed a bridge exercise with one hip Joint adduction. BEG performed a bridge exercise without resistance. Results: The external oblique abdominal, internal oblique abdominal, and the transversus abdominis muscles showed a significant increase by period and time in intra-group interactions (p<0.05), while there was no significant difference in inter-group changes (p>0.05). The erector spinae muscle had a significant increase in each period (p<0.05) but no significant difference in time, intra-group interactions, and in inter-group changes (p>0.05). Conclusion: These results demonstrated that bridge exercise with one hip joint adduction had positive effects on trunk muscle thickness. These results confirm that a bridge exercise with one hip joint adduction has a positive effect on the muscle thickness of trunk, suggesting the possibility of using it as a rehabilitation treatment for a lumbar stabilization exercise and as a basic data.

A cone-beam computed tomography evaluation of buccal bone thickness following maxillary expansion

  • Akyalcin, Sercan;Schaefer, Jeffrey S.;English, Jeryl D.;Stephens, Claude R.;Winkelmann, Sam
    • Imaging Science in Dentistry
    • /
    • v.43 no.2
    • /
    • pp.85-90
    • /
    • 2013
  • Purpose: This study was performed to determine the buccal alveolar bone thickness following rapid maxillary expansion (RME) using cone-beam computed tomography (CBCT). Materials and Methods: Twenty-four individuals (15 females, 9 males; 13.9 years) that underwent RME therapy were included. Each patient had CBCT images available before (T1), after (T2), and 2 to 3 years after (T3) maxillary expansion therapy. Coronal multiplanar reconstruction images were used to measure the linear transverse dimensions, inclinations of teeth, and thickness of the buccal alveolar bone. One-way ANOVA analysis was used to compare the changes between the three times of imaging. Pairwise comparisons were made with the Bonferroni method. The level of significance was established at p<0.05. Results: The mean changes between the points in time yielded significant differences for both molar and premolar transverse measurements between T1 and T2 (p<0.05) and between T1 and T3 (p<0.05). When evaluating the effect of maxillary expansion on the amount of buccal alveolar bone, a decrease between T1 and T2 and an increase between T2 and T3 were found in the buccal bone thickness of both the maxillary first premolars and maxillary first molars. However, these changes were not significant. Similar changes were observed for the angular measurements. Conclusion: RME resulted in non-significant reduction of buccal bone between T1 and T2. These changes were reversible in the long-term with no evident deleterious effects on the alveolar buccal bone.

The Immunohistochemical Changes of Skin during Hair Follicle Cycle after Depilation in Mice

  • Kim, Dae-Keun;Lee, Chang-Hyun
    • Biomedical Science Letters
    • /
    • v.16 no.4
    • /
    • pp.349-357
    • /
    • 2010
  • We have examined the histological changes of skin during hair follicle growth after depilation in C57BL/6N mice. We first studied on histological changes of number of mast cells and thickness of skin during hair follicle growth periods (telogen, 1 day, 3 day, 5 day, 10 day, 14 day, 17 day and 21 day after depilation) by toluidine blue, Giemsa and H&E staining methods. We second studied immunoreactive density of cytokines and Brdu labeled cells in skin during hair follicle growth periods after depilation in C57BL/6N mice by immunohistochemical methods. The histological changes on skin thickness was increased from telogen to 14 day. The number of mast cells was decreased in 3,5 and 10 day and increased in 14, 17 and 20 day after depilation. Immunoreactive density of cytokines [protein kinase C-${\alpha}$ (PKC-${\alpha}$), c-kit, and vascular endothelial growth factor (VEGF)] in 1, 3, 5, 10, and 14 day after depilation was mildly stained in bulge and cutaneous trunci m., but immunoreactive density of cytokines in 17 and 21 day was heavily stained in epidermis, bulge, outer root sheath (ORS), inner root sheath (IRS) and cutaneous trunci m.. Immunoreactive density of Brdu labeled cells in skin in 1 and 3 day was heavily stained in bulge, epidermis and connective tissue under the cutaneous trunci m.. In all periods, immunoreactive density of Brdu labeled cells in skin was heavily stained in bulge, subcutaneous tissue, cutaneous trunci m, ORS and IRS. These experiments suggest that histological changes related to hair follicle growth elevated mast cell counts, skin thickness and epidermis thickness and heavily stained immunoreactive density of cytokines and Brdu labeled cutaneous trunci m. and connective tissue under the cutaneous trunci m. after depilation in C57BL/6N mice.

Evaluation of normal masseter muscles on ultrasonography (초음파영상을 이용한 정상 교근의 평가)

  • Hwang, Hyoung-Zoo;Kim, Gyu-Tae;Choi, Yong-Suk;Hwang, Eui-Hwan
    • Imaging Science in Dentistry
    • /
    • v.38 no.2
    • /
    • pp.73-79
    • /
    • 2008
  • Purpose: To assess the internal echo intensity and morphological variability of masseter muscles on ultrasonography and to establish diagnostic criterion of estimation. Materials and Methods: Participants consisted of 50 young adults (male 25, female 25) without pathologic conditions and with full natural dentitions. Sonographic examinations were done with real time ultrasound equipment as Logiq 500 (GE Medical Systems, Seoul, Korea) at 3 parts according to lines paralleling with ala-tragus line as reference line. The thickness and area of masseter muscles according to reference line in cross-sectional images were measured at rest and at maximum contraction. The visibility and width of the internal echogenic intensity of the masseter muscles were also assessed and the muscle appearance was classified into 4 types. Data were statistically analyzed by paired t-test and $x^2$-test. Results: 1. When comparing the thickness and area of masseter muscles concerning with gender, there was few significant difference between right and left sides, however, there were significant differences between males and females except for the greatest thickness of left side. 2. The changes of the greatest thickness and the area between rest and maximum contraction showed that the part of the least thickness manifested more increase at maximum contraction. 3. Each part the manifestations of the internal echogenic intensity of the masseter muscles were different depending on the locations. But there was no statistically significance. Conclusion: Changes of muscles thickness with contraction and internal echogenic intensity with locations showed great disparity within the masseter muscles, which will be diagnostic criteria for pathophysiologic and anatomic changes of masseter muscles.

  • PDF

Changes in Physicochemical Characteristics of Mature-Green Mume (Prunus mume Sieb. et Zucc) Fruits as Influenced by the Thickness of Packaging Material (포장재 두께에 따른 청매실의 이화학적 특성 변화)

  • 차환수;정명수
    • Food Science and Preservation
    • /
    • v.9 no.2
    • /
    • pp.148-153
    • /
    • 2002
  • Effect of the thickness of low density polyethylene(LDPE) Film as packaging material on changes in physicochemical characteristics of mature-green mume (Prunus mume Sieb. et Zucc) fruits during storage at different temperatures(0, 10 and 25$\^{C}$) were investigated. Fruit samples stored in pouches with 30㎛ thickness of LDPE film maintained well not only external qualities such as Shape and firmness, but also internal chemical properties such as pH, acidity, the content of soluble solid and chlorophyll, and color, comparing with samples stored without packaging material or in other pouches with different film thickness(20 and 40㎛). From the results, it was found that the maintenance of quality of mature-green mume fruits during storage at 0, 10 and 25$\^{C}$ closely related to the changes in respiratory conditions for fruits affected by the film thickness of the packaging material.

Changes of Physical and Mechanical Properties of Firefighter Protective Clothing After Radiant Heat Exposure (노출시간과 열강도에 따른 복사열 노출후의 소방보호복의 물리적 특성과 역학적 특성변화)

  • ;N.Pan;G.Sun
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.23 no.6
    • /
    • pp.853-863
    • /
    • 1999
  • the change of physical properties (thickness, weight, air permeability) and mechanical properties(abrasion resistance breaking load and displacement) of samples were determined after heat exposure by a RPP tester. The effect of exposure time and heat flux intensity on the changes and the relationship between physical properties and mechanical properties were investigated. FR treated cotton Kevlar/PBI and Nomex with different structureal characteristics were chosen for specimens. The changes of physical properties and mechanical properties were calculated based on their initial values before heat exposure. The longer exposure time and the high heat flux intensity the more changes of those properties. Heat flux intensity was more effective on the changes, The showed to be affected by an interplay of shrinkage and pyrolysis products loss. The changes of thickness and abrasion resistance showed to be higher for plain weave fabric and those of air permeabiliyt and breaking load and displacement for twill weave fabric. While FR treated cotton which have high RPP value experienced serious and detrimental changes after heat exposure Kevlar/PBI which has low RPP value showed no high changes. In conclusion it could be confirmed that when total performance of a protective clothing is estimated retention capability of physical and mechanical properties after heat exposure as well as RPP value must be considered.

  • PDF