• Title/Summary/Keyword: thickness changes

Search Result 1,691, Processing Time 0.031 seconds

Comparison of Changes in the Thickness of the Abdominal Muscles in Different Standing Positions in Subjects With and Without Chronic Low Back Pain (만성 요통 유무와 자세에 따른 복부근 두께변화 비교)

  • Won, Jong-Im
    • PNF and Movement
    • /
    • v.18 no.3
    • /
    • pp.415-424
    • /
    • 2020
  • Purpose: This study aimed to compare changes in abdominal muscle thickness in different standing postures with a handheld load between subjects with and without chronic low back pain (CLBP). Methods: Twenty subjects with CLBP and 20 controls participated in this study. Ultrasound imaging was used to assess the changes in the thickness of the transverse abdominis (TrA), internal oblique (IO), and external oblique (EO) muscles. Muscle thickness in three different standing postures (standing at rest, standing with loads, standing with lifting loads) was compared with the muscle thickness at rest in the supine position and was expressed as a percentage of change in the thickness of the muscle. Results: While standing with loads, the change in IO muscle thickness in the CLBP patients increased more significantly than in the pain-free controls (p < 0.05). The standing with lifting loads posture showed a significant increase in the change in thickness of the TrA compared with the standing with loads posture (p < 0.05). In addition, the standing with lifting loads posture showed a significant decrease in the change in the thickness of the EO when compared with the standing with loads posture (p < 0.05). Conclusion: The automatic activity of the IO muscle in subjects with CLBP increased more than that of the pain-free controls in the standing with loads posture. These findings suggest that IO muscle function may be altered in those with CLBP while standing with loads. Additionally, TrA the activation level was found to be associated with increased postural demand caused by an elevated center of mass.

Effect of Bridge Exercise on the Thickness of Abdominal Muscle according to Support and Knee Angle (지지면과 무릎관절 각도에 따른 교각운동이 복부근육의 두께에 미치는 영향)

  • Mun, Dal Ju;Park, Jae Cheol;Choi, Suk Ju
    • Journal of Korean Physical Therapy Science
    • /
    • v.25 no.3
    • /
    • pp.25-31
    • /
    • 2018
  • Background: The purpose of this study was to find out how changes in knee angles in stable and unstable support surfaces affect the muscle thickness of core muscles. Methods: The subjects of this study were 25 male adult. Each knee angle of 120, 90 and 60 degrees, they were performed bridge exercise on the stabilized surface and on the unstable support surface using TOGU, and measured the muscle thickness of the external and internal oblique muscle and the abdominal muscles through ultrasound images. Results: There was no significant difference between the thickness of the rectus abdominis and the internal oblique muscle depending on the support surface and the knee joint bending angles. However, there was a significant difference between the external oblique muscle and the transverse abdominis muscle by knee joint flexion angle. Conclusion: While the muscle thickness of the core muscle was not significantly affected by each support surface during the bridge exercise, there were significant changes in the core muscle as a result of changes in knee angle.

Effect of Vibration Exercise Application on the Trunk Muscle Thickness in Children with Spastic Cerebral Palsy

  • Mun, Dal-Ju;Park, Jae-Chul;Oh, Hyun-Ju
    • The Journal of Korean Physical Therapy
    • /
    • v.34 no.2
    • /
    • pp.68-72
    • /
    • 2022
  • Purpose: This study examined the effect of vibration exercise on the thickness of the oblique extrinsic, oblique abdominal, and biceps muscles, which are trunk muscles, targeting children with spastic cerebral palsy. Methods: The participants in this study were 20 children (8 male and 12 female) with cerebral palsy aged 5-10 years. They were classified into two groups using a randomized allocation method, and the trunk muscle thickness was measured using an ultrasound-imaging device before and six weeks after the experiment. A paired t-test was used for the within-group changes, and an independent t-test was used for the inter-group changes. The significance level was set to α=0.05. Results: There was a significant increase in the inter-group change in the experimental group and control group in the intra-group change in the external oblique muscle and internal oblique muscle. After six weeks, there was a significant increase in the experimental group compared to the control group. Conclusion: Vibration exercise had a positive effect on the trunk muscle thickness of children with cerebral palsy. Vibration exercise produced a significant difference in the changes in the trunk muscle thickness in children with cerebral palsy compared to no vibration exercise. These results may provide basic data for future research and as a training method for strengthening the trunk muscles in clinical trials.

Measurement of the Noise according to the Slice Thickness in MDCT (MDCT에서 절편두께에 따른 Noise 측정)

  • Moon, Il-Bong;Dong, Kyung-Rae;Kim, Mi-Hyun;Choi, Sung-Hyun;Kweon, Dae-Cheol;Goo, Eun-Hoe
    • Journal of Radiation Industry
    • /
    • v.11 no.3
    • /
    • pp.151-155
    • /
    • 2017
  • MDCT is used to determine how the noise changes as the slice thickness changes. Noise according to thickness of 1.5, 3.0, 5.0 and 10.0 mm was analyzed using the Siemens (Somatom Definition Flash, Germany) equipment and calibration conditions such as tube voltage and tube current using the calibration QC phantom. 1.5, 3.0, 5.0 and 10.0 mm, respectively. The mean HU was 1.5 mm (7.7 HU), 3.0 mm (4.9 HU) and was reduced by 59.5% from 1.5 mm. 5.0 mm (3.9 HU) and 97.6% compared to 1.5 mm, 10.0 mm (3.1 HU) and 148% less than 1.5 mm. It was found that as slice thickness increased, noise decreased, while slice thickness decreased. In conclusion, setting the appropriate slice thickness for each site may be useful for obtaining appropriate noise and image quality.

Ultrastructural Changes in the Cuticle of Palaemon serrifer (Palaemonidae, Crustacea) during the Intermolt Cycle

  • Park Jeung Sook
    • Fisheries and Aquatic Sciences
    • /
    • v.2 no.1
    • /
    • pp.78-84
    • /
    • 1999
  • Ultrastructural changes in the cuticle of Paleamon serrifer associated with the intermolt cycle were examined and quantified as changes in the cuticular thickness. The cuticular thickness in each zoea stage increased with time elapsed after molting. The cuticle in the premolt stage was about 1.5 and 3 times thicker than that in the postmolt and intermolt stage, respectively. The cuticle in the premolt stage, including the molting space, was more than 5 times as thick as in the postmolt stage. In addition, newly hatched larvae were individually reared in the laboratory and body length for each specimen was measured frequently until the end of zoea VI. An average increase in body length between one zoea stage and the next is about $10\%$ of the length of the previous stage. Within individual zoea stages, the premolt stage had a body length some 0.3% longer than that of the postmolt stage, indicating a growth rate of about 0.03 mm/d.

  • PDF

The effect of wall squat exercise according to the difference in the support surface on the muscle thickness and balance of the trunk (지지면 차이에 따른 월 스쿼트 운동이 몸통 근두께와 균형에 미치는 영향)

  • Jeong, Jin Gyu;Park, Jae Cheol
    • Journal of Korean Physical Therapy Science
    • /
    • v.29 no.1
    • /
    • pp.64-72
    • /
    • 2022
  • Background: The purpose of this study is to investigate the effect of wall squat exercise according to the difference in the support surface on the thickness change of external oblique, internal oblique and transverse abdominalis of the trunk muscles and the change in distance of center of pressure when the eyes are opened and closed. Design: Randomized controlled trial. Methods: The subjects were 26 healthy adults, 18 males and 8 females. The composition of each group using the single-blind method was 13 people in the unstable side wall squat exercise group and 13 people in the stable side wall squat exercise group. Experimental measurements were divided into before, 3 weeks, and 6 weeks after the experiment, and changes in muscle thickness and balance were confirmed. Muscle thickness was measured using ultrasinic, and static balance change was measured using Bio-rescue. Results: There were significant differences in the thickness changes of external oblique, internal oblique and transverse abdominalis according to the wall squat exercise method by period and in the interaction between the period and the group (p<0.05). As a result of the post-hoc analysis, there was a significant difference in the change between the two groups in external oblique muscle after 6 weeks. And there was a significant difference in the distance of the pressure center between eyes open and closed eyes (p<0.05). Conclusion: In terms of instability, wall squat exercise was positive for changes in trunk muscle thickness. It suggests the possibility of using it for trunk muscle strengthening training in the future.

The effect of lip thickness on lip profile change after orthodontically treated patients with 4 first bicuspid extraction (Basic upper lip thickness에 따른 교정치료 후 입술 이동량의 차이)

  • Park, Sun-Hyung;Park, Sung-Hun;Cho, Young-Moon;Kim, Jung-Hoon
    • The korean journal of orthodontics
    • /
    • v.32 no.5 s.94
    • /
    • pp.355-360
    • /
    • 2002
  • After orthodontic treatment, there are several changes in soft tissue profile. Changes appear at lower anterior facial profile area, especially upper and lower lip. But there are many individual variations in the pattern of changes. So, this study was conducted to find out that the basic upper lip thickness could be one of the factors that could influence the treatment results. The samples were composed of 43 adult patients who had their 4 first premolars extracted. Groups were classified by their basic lip thickness. In group 1(thin upper lip group), there was negative relationship between mentolabial angle and lower lip change. In group 2(average lip thickness group), upper lip change was related to upper incisor change, lower incisor change, lower lip change and nasolabial angle change. And lower lip change was related to upper lip change, upper incisor change, lower incisor change. In group 3(thick upper lip group), there was no relation between both lip change and other variables.

Effect of push-up plus exercise on shoulder stabilization muscle thickness in healthy adults in their twenties on various support surfaces (다양한 지지면에서 푸쉬업 플러스 운동이 20대 건강한 성인의 어깨 안정화 근육 두께에 미치는 영향)

  • Jeong, Jin Gyu;Park, Jae Cheol
    • Journal of Korean Physical Therapy Science
    • /
    • v.29 no.3
    • /
    • pp.48-55
    • /
    • 2022
  • Background: The purpose of this study is to examine the effect of push-up plus exercise on the changes in the thickness of the trapezius trapezius, serratus anterior and pectoralis major muscles involved in shoulder stability in various support surfaces. Design: Randomized controlled trial. Methods: The thickness change of the shoulder stabilizing muscle was measured using an ultrasound device. Corresponding t-test was performed to confirm the change within the group before the experiment and after 5 weeks. And one-way ANOVA was used to confirm the change between groups after 5 weeks. As a post hoc test, the least significant difference test was performed, and the significance level was set to a=0.05. Results: Changes in the thickness of the trapezius muscle within the group were significantly different between UPEG and SPEG after 5 weeks (p<0.05), and there was a significant difference between groups after 5 weeks (p<0.05). Changes in the thickness of the serratus anterior and pectoralis major muscle within the group were significantly different after 5 weeks in PEG, UPEG and SPEG (p<0.05), and the changes between the groups were significantly different in the serratus anterior muscle after 5 weeks (p<0.05). Conclusion: From the results of this study, it was found that the push-up exercise on an unstable support surface was effective for strengthening the trapezius upper and serratus anterior. This study intends to suggest the possibility of application as basic data for a push-up plus exercise program in clinical practice.

Analysis of the OLEDs Characteristics using Simulation (시뮬레이션을 이용한 유기발광다이오드 특성 해석)

  • Park, Young-Ha;Kim, Weon-Jong;Sin, Hyun-Taek;Cho, Kyung-Soon;Kim, Gwi-Yeol;Hong, Jin-Woong
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2008.11a
    • /
    • pp.46-47
    • /
    • 2008
  • Organic light-emitting diode is quick response speed, low power consumption and the self-interest has many advantages, such as insanity. So, organic light-emitting diode mechanism of light-emitting diode in order to more clearly understand the changes in the thickness of emitting materials for OLED characteristics of the simulation. emitting layer to a thickness of 10 [nm] ~ 100 [nm] changed the experiment, and hole transport layer 190 [nm] as a fixed. and emitting layer 10 [nm] ~ 100 [nm] to change the simulation results. Changes in the thickness of emitting layer gradually increased. depending on the emitting was 20 [nm] in the high 441 [lm / W] shows. and was gradually reduced. emitting layer 190 [nm] when fixed, hole transport layer, depending on changes in the thickness of 70 [nm] in the efficiency maximum value of 477 [lm / W], and was gradually reduced.

  • PDF

Comparison of the Abdominal Muscle Thickness during Abdominal Hollowing Exercise According to the Visual Feedback Method (할로잉 운동 시 시각적 피드백 방법에 따른 복근 두께에 미치는 영향 비교)

  • Kim, Ha-Rim;Son, Ho-Hee
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.16 no.3
    • /
    • pp.107-113
    • /
    • 2021
  • PURPOSE: Selective strengthening of the transverse abdominis muscle (TrA) during abdominal hollowing makes an important contribution to the stability and control of the spine. This study examined the effects of abdominal hollowing exercise (AHE) according to the visual feedback method on the external oblique, internal oblique, and transverse abdominis muscles. METHODS: Twenty healthy subjects were assigned randomly to an AHE with visual feedback from real-time ultrasound image (group A, n = 10), AHE with visual feedback with pressure biofeedback unit (group B, n = 10). Both groups underwent 20 min of AHE with visual feedback once daily, five days/week for two weeks. The changes in the muscle thickness of the TrA, internal oblique abdominal muscle (IO), and external oblique abdominal muscle (EO) were measured by ultrasonography. RESULTS: The thickness of TrA was changed significantly in both groups (p < .05). However, the lowest minimal detectable changes were achieved in Group A. The thickness of the IO and EO muscles in group A was changed significantly, but there were no significant changes in group B. CONCLUSION: Both visual feedback methods were effective for strengthening the TrA muscles selectively. Nevertheless, AHE with visual feedback using real-time ultrasound images may be more useful in trA muscle contraction.