Prediction model of 4.5 K sorption cooler for integrating with adiabatic demagnetization refrigerator (ADR)

  • Kwon, Dohoon;Kim, Jinwook;Jeong, Sangkwon
    • Progress in Superconductivity and Cryogenics
    • /
    • v.24 no.1
    • /
    • pp.23-28
    • /
    • 2022
  • A sorption cooler, which utilizes helium-4 as a working fluid, was previously developed and tested in KAIST. The cooler consists of a sorption pump and a thermosyphon. The developed sorption cooler aims to pre-cool a certain amount of the magnetic refrigerant of an adiabatic demagnetization refrigerator (ADR) from 4.5 K to 2.5 K. To simulate the high heat capacitance of the magnetic refrigerant, liquid helium was utilized not only as a refrigerant for the sorption cooling but also as a thermal capacitor. The previous experiment, however, showed that the lowest temperature of 2.7 K which was slightly higher than the target temperature (2.5 K) was achieved due to the radiation heat leak. This excessive heat leak would not occur when the sorption cooler is completely integrated with the ADR. Thus, based on the experimentally obtained pumping speed, the prediction model for the sorption cooler is developed in this study. The presented model in this paper assumes the sorption cooler is integrated with the ADR and the heat leak is negligible. The model predicts the amount of the liquid helium and the required time for the sorption cooling process. Furthermore, it is confirmed that the performance of the sorption cooler is enhanced by reducing the volume of the thermosiphon. The detailed results and discussions are summarized.

Experimental and theoretical justification of passive heat removal system for irradiated fuel assemblies of the nuclear research reactor in a spent fuel pool

  • Ta Van Thuong;O.L. Tashlykov;S.M. Glukhov;D.E. Shumkov;Yu.V. Volchikhina
    • Nuclear Engineering and Technology
    • /
    • v.55 no.6
    • /
    • pp.2088-2095
    • /
    • 2023
  • The safety of nuclear installations is largely determined by the tightness of fuel elements cladding. As the Fukushima nuclear accident showed, the main task in case of loss of power supply is to ensure reliable removal of residual heat release from spent fuel pool (SFP) with irradiated fuel assemblies (IFAs). The paper presents the results of calculated-experimental studies and thermal-hydraulic modeling of temperature storage modes of IFAs in SFP. Experimental studies of SFP's temperature regime and calculated evaluation of residual heat removal due to the thermal conductivity of building structures surrounding the SFP were performed. To ensure the safe operation of research reactors, it's necessary to know the IFA's residual heat power (RHP) in the reactor and SFP, which is determined depending on the operating time of fuel assemblies (FAs) and the IFAs calculated holding time. The FAs operating time depends on the reactor energy output. The IFAs calculated holding time is determined by the fuel burnup, U-235 mass in the fuel, and reactor utilization factor. The IFAs fuel burnup was calculated using the MCU-PTR program. Also presented are the RHP's calculation results using some of the empirical dependencies. The concept of a passive heat removal system (PHRS) based on thermosyphon's operating principle was proposed.

Performance of Natural Circulation Hot Water System with Flat-Plate Solar Collectors (평만형 태양열 집열기 를 설치한 자연 순환식 급탕시스템 의 성능 에 관한 연구)

  • 윤석범;전문헌
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.9 no.5
    • /
    • pp.579-589
    • /
    • 1985
  • The storage tank of the natural-circulation-solar-hot-water system equipped with flat-plate solar collectors is located at higher elevation than the solar collectors. Therefore, the heat loss from the system due to a reversed flow during the night-time is an important factor as well as the day-time thermal performance of the system. The thermal performance of the natural-circulation-solar-hot-water system with flat-plate solar collectors during the day-time depends mainly on the heat collecting efficiency of the solar collectors, whereas its thermal performance during the night-time depends on the system configuration , such as the elevation of the water storage tank with respect to the solar collectors and the piping connections between the storage tank and the solar collectors, as well as thermo-physical properties of the circulating fluid. In the present work, a computer program has been developed to simulate a typical natural-circulation-solar-hot-water-system, and a series of simulation tests have been carried out with the computer program to examine the thermal performance of the system during the day-time as well as the hight-time. In addition , a series of experiment have been conducted under a real sun condition using a natural-circulation-solar-hot-water-system constructed and installed at the KAIST building to compare with the results obtained from computer simulations.

Recent Progress in Air Conditioning and Refrigeration Research - A Review of papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 1998 and 1999 - (공기조화, 냉동 분야의 최근 연구 동향 - 1998년 1999년 학회지 논문에 대한 종합적 고찰 -)

  • 이재헌;김광우;김병주;이재효;김우승;조형희;김민수
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.12 no.12
    • /
    • pp.1098-1125
    • /
    • 2000
  • A review on the papers published in the Korean Journal of Air-Conditioning and Refrigerating Engineering in 1998 and 1999 has been done. Focus has been put on current status of research in the aspect of heating, cooling, ventilation, sanitation and building environment. The conclusions are as follows. 1) A review of the recent studies on fluid flow, turbomachinery and pipe-network shows that many experimental investigations are conducted in applications of impingement jets. Researches on turbulent flows, pipe flows, pipe-networks are focused on analyses of practical systems and prediction of system performance. The results of noise reduction in the turbomachinery are also reported. 2) A review of the recent studies on heat transfer analysis and heat exchanger shows that there were many papers on the channel flow with the application to the design of heat exchanger in the heat transfer analysis. Various experimental and numerical papers on heat exchanger were also published, however, there were few papers available for the analysis of whole system including heat exchanger. 3) A review of the recent studies on heat pump system have focused on the multi-type system and the heat pump cycle to utilize treated sewage as the heat source. The defrosting and the frosting behaviors in the fin-tube heat exchanger is experimentally examined by several authors. Several papers on the ice storage cooling system are presented to show the dynamic simulation program and optimal operation conditions. The study on the micro heat pipes for the cooling of high power electronic components is carried out to examine the characteristics of heat and mass transfer processed. In addition to these, new type of separate thermosyphon is studied experimentally. 4) The recent studies on refrigeration/air conditioning system have focused on the system performance and efficiency for new alternative refrigerants. New systems operating with natural refrigerants are drawing lots of attention. In addition to these, evaporation and condensation heat transfer characteristics of traditional and new refrigerants are investigated for plain tubes and also for microfin tubes. Capillary tubes and orifice are main topics of research as expansion devices and studies on thermophysical properties of new refrigerants and refrigerant/oil mixtures are widely carried out. 5) A review of the recent studies on absorption cooling system shows that numerous experimental and analytical studies on the improvement of absorber performance have been presented. Dynamic analysis of compressor have been performed to understand its vibration characteristics. However research works on tow-phase flow and heat transfer, which could be encountered in the refrigeration system and various phase-change heat exchanger, were seemed to be insufficient. 6) A review of recent studies on duct system shows that the methods for circuit analysis, and flow balancing have been presented. Researches on ventilation are focused on the measurement of ventilation efficiency, and variation of ventilation efficiency with ventilation methods by numerous experimental and numerical studies. Furthermore, many studies have been conducted in real building in order to estimate indoor thermal environments. Many research works to get some information for cooling tower design have been performed but are insufficient. 7) A review on the recent studies on architectural thermal environment and building mechanical systems design shows that thermal comfort analysis is sitting environment, thermal performance analysis of Korean traditional building structures., and evaluation of building environmental load have been performed. However research works to improve the performance of mechanical system design and construction technology were seemed to be insufficient.

  • PDF

Genetic Analyses of Heading and Maturing Dates and Their Relationship to Freezing Resistance in Barley (보리 출수기와 성숙기의 유전분석 및 내동성과의 관계)

  • 천종은;강석원
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.47 no.6
    • /
    • pp.395-401
    • /
    • 2002
  • The combination of early heading time, maturing time and short grain-filling period is very important to develop early varieties in winter barley. The 4 parental half diallel crosses (parents, $F_1$s, $F_2$s) were cultivated at the field. The heading date was from April 3 to 26, maturing date from May 15 to 27 and grain-filling period from 31 days to 42 days, showing that the varietal differences about the 3 traits were remarkable. According to half diallel cross analyses, Dongbori 1 for heading time (late heading) was dominant, but Oweolbori (early heading) was recessive, showing partial dominance with high additive component of genetic variance. Dongbori 1 for maturing time was dominant, but Oweolbori was recessive, showing partial dominance with high additive variance. Reno for grain-filling period (short grain-filling period) was dominant, but Oweolbori (long grain-filling period) was recessive with additive, and partial dominance. There were highly significant mean squares for both GCA and SCA effects on the heading and maturing times, and GCA/SCA ratios for all traits were high, showing the additive gene effects more important. Sacheon 6 and Oweolbori had greater GCA effects for early heading and maturing times, and Dongbori 1 and Reno had greater GCA effects for late times. GCA effects were highly significant in $F_1$ and $F_2$ generations, showing high GCA/SCA ratios (7.02). The heading and maturing times in field were positively correlated with antifreeze proteins concentrations, accumulation, resistance to photoinhibition and winter survival, respectively) but the grain-filling period did negatively correlated with the trails.

The Effect of Cold Shock on Function and Morphology of Dog Epididymal Spermatozoa (개에서 cold shock이 정소상체유래의 정자의 기능과 형태에 미치는 영향)

  • Yu Il-jeoung
    • Journal of Veterinary Clinics
    • /
    • v.21 no.4
    • /
    • pp.329-335
    • /
    • 2004
  • Dog spermatozoa were recovered from the caudae epididymides of 23 domestic dogs which were 11 pure breed and 12 mix-breed dogs ranging in age from 0.6 to 3 years. The experimental designs were as follows: 1) the effect of chilling to 0. 10 or 37$^{\circ}C$. 2) the kinetics of chilling injury at 0 or 4$^{\circ}C$, and 3) the effect of sugars at $0^{\circ}C$. Viable spermatozoa were recovered by percoll gradient separation and adjusted to 5${\times}$10$^{7}$ spermatozoa/ml. In experiment 1, spermatozoa were diluted with 0.33 M glucose supplemented with 3% BSA (G-BSA) at 1:2 dilution. Spermatozoa were loaded into straws and exposed at 0, 10 or 37$^{\circ}C$ for 30 min. In experiment 2, spermatozoa were prepared as the experiment 1 and exposed for 0.5, 5, 15, or 30 min at 0 or 4$^{\circ}C$. In experiment 3, spermatozoa were diluted with different sugars (0.33 M galactose, glucose, fructose, mannitol, lactose, sucrose, raffinose) and cooled to $0^{\circ}C$ for 30 min. Sperm membrane integrity, motility and acrosome integrity were assayed after rewarming at 37$^{\circ}C$ for 5 min. Sperm motility and membrane integrity abruptly decreased with decreasing temperature but acrosome integrity gradually decreased (P<0.05). Sperm motility was more sensitive to cold shock than membrane integrity and acrosome integrity. Spermatozoa cooled to $0^{\circ}C$ were more damaged than those at 4$^{\circ}C$. Sperm motility was not different among exposed times at both. 0 and 4$^{\circ}C$. However, membrane integrity of spermatozoa exposed for 30 min at both 0 and 4$^{\circ}C$ was significantly lower (P<0.05). Spermatozoa diluted in 0.33 M fructose or galactose showed lower motility and higher morphological abnormality with coiled tail at $0^{\circ}C$. These sperm characteristics were strongly related. These results indicate that dog epididymal spermatozoa are relatively sensitive to rapid cooling and higher morphological abnormality at $0^{\circ}C$ was shown in spermatozoa diluted in fructose and galactose.

Effect of Leaf Aqueous Extracts from Some Gymnosperm Plant on the Seed Germination, Seedling Growth and Transplant of Hibiscus syriacus Varieties (수종 나자식물의 잎 수용 추출액이 무궁화의 품종별 종자발아와 유식물 및 초기생장에 미치는 영향)

  • 배병호;김용옥
    • The Korean Journal of Ecology
    • /
    • v.26 no.1
    • /
    • pp.39-47
    • /
    • 2003
  • The leaf aqueous extracts from five gymnosperms plant were investigated for allelopathy with five Hibiscus syriacus varieties. The leaf aqueous extract of Pinus rigida had the highest total phenolic compound of 2.21mg/L, whereas the soil under Pinus koraiensis canopy had the highest total phenolic compound of 1.38mg/L. Fourteen phenolic compounds were isolated from five gymnosperm plants by HPLC. Among them, phenolic compounds were the highest in P. rigida (320.56 g/mg) with the primary compound 5-sulfosalicylic acid (312.55 g/mg). The correlation between leaf total phenolic compound and pH was not significant, while the total phenolic compound of the leaf extract changed soil pH. The relative seed germination of H. syriacus varieties showed 25% was threshold concentration. The germination rates of varieties were similar to the control group or showed slight stimulation to treatment of P. koraiensis extract. H. syriacus Cambanha was similar to the control group or showed stimulation in all treated groups. H. syriacus Seohohyang showed stimulation in both root and shoot growth compared to the control group. In other varieties except Seohohyang, shoot growth was similar to the control group, while root growth was stimulated in all treated groups. The extracts of tested gymnosperms showed significantly more stimulation to transplanted Seohohyang seedlings, whereas others were similar to control or inhibited in the greenhouse. The dry weight of Seohohyang was greater in all treated groups than the control group, while other varieties were inhibited. All gymnosperm extracts stimulated the chlorophyll contents of Seohohyang and H. syriacus Koyoro but other varieties were not significantly affected. Accordingly, it is suggested that Seohohyang seems the most desirable when planted within these five gymnosperms.