• Title/Summary/Keyword: thermometry

Search Result 67, Processing Time 0.021 seconds

Conceptual design of a copper-bonded steam generator for SFR and the development of its thermal-hydraulic analyzing code

  • Im, Sunghyuk;Jung, Yohan;Hong, Jonggan;Choi, Sun Rock
    • Nuclear Engineering and Technology
    • /
    • v.54 no.6
    • /
    • pp.2262-2275
    • /
    • 2022
  • The Korea Atomic Energy Research Institute (KAERI) studied the sodium-water reaction (SWR) minimized steam generator for the safety of the sodium-cooled fast reactor (SFR), and selected the copper bonded steam generator (CBSG) as the optimal concept. This paper introduces the conceptual design of the CBSG and the development of the CBSG sizing analyzer (CBSGSA). The CBSG consists of multiple heat transfer modules with a crossflow heat transfer configuration where sodium flows horizontally and water flows vertically. The heat transfer modules are stacked along a vertical direction to achieve the targeted large heat transfer capacity. The CBSGSA code was developed for the thermal-hydraulic analysis of the CBSG in a multi-pass crossflow heat transfer configuration. Finally, we conducted a preliminary sizing and rating analysis of the CBSG for the trans-uranium (TRU) core system using the CBSGSA code proposed by KAERI.

Direct-contact heat transfer of single droplets in dispersed flow film boiling: Experiment and model assessment

  • Park, Junseok;Kim, Hyungdae
    • Nuclear Engineering and Technology
    • /
    • v.53 no.8
    • /
    • pp.2464-2476
    • /
    • 2021
  • Direct-contact heat transfer of a single saturated droplet upon colliding with a heated wall in the regime of film boiling was experimentally investigated using high-resolution infrared thermometry technique. This technique provides transient local wall heat flux distributions during the entire collision period. In addition, various physical parameters relevant to the mechanistic modelling of these phenomena can be measured. The obtained results show that when single droplets dynamically collide with a heated surface during film boiling above the Leidenfrost point temperature, typically determined by droplet collision dynamics without considering thermal interactions, small spots of high heat flux due to localized wetting during the collision appear as increasing Wen. A systematic comparison revealed that existing theoretical models do not consider these observed physical phenomena and have lacks in accurately predicting the amount of direct-contact heat transfer. The necessity of developing an improved model to account for the effects of local wetting during the direct-contact heat transfer process is emphasized.

Experimental Study on Heat Flux Partitioning in Subcooled Nucleate Boiling on Vertical Wall (수직 벽면에서 과냉 핵비등 시 열유속 분배에 관한 실험적 연구)

  • Song, Junkyu;Park, Junseok;Jung, Satbyoul;Kim, Hyungdae
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.38 no.6
    • /
    • pp.465-474
    • /
    • 2014
  • To validate the accuracy of the boiling heat flux partitioning model, an experiment was performed to investigate how the wall heat flux is divided into the three heat transfer modes of evaporation, quenching, and single-phase convection during subcooled nucleate boiling on a vertical wall. For the experimental partitioning of the wall heat flux, the wall heat flux and liquid-vapor distributions were simultaneously obtained using synchronized infrared thermometry and the total reflection technique. Boiling experiments of water with subcooling of $10^{\circ}C$ were conducted under atmospheric pressure, and the results obtained at the wall superheat of $12^{\circ}C$ and average heat flux of $283kW/m^2$were analyzed. There was a large difference in the heat flux partitioning results between the experiment and correlation, and the bubble departure diameter and bubble influence factor, which account for a portion of the surrounding superheated liquid layer detached by the departure of a bubble, were found to be important fundamental boiling parameters.

Experiment on water turbulent natural convection for safety improvement of nuclear power plant (원자력발전소 안전성 평가 향상을 위한 물 자연대류 검증 실험)

  • Kim, Donghyuk;Ryu, Nayoung;Kim, Man-Bae;Park, Chang-Yong;Kim, Jungwoo
    • Journal of the Korean Society of Visualization
    • /
    • v.14 no.3
    • /
    • pp.46-50
    • /
    • 2016
  • The objective of the present study is to perform experiments for water filled cavity heated and cooled from the side at $Ra=8.5{\times}108$. This experiment can provide validation database of the standard k-${\varepsilon}$ turbulence model for single-phase turbulent natural convection which has been regarded as one of the important phenomena in nuclear safety. For the natural convection inside a cavity, temperature and velocity were obtained by thermometry and PIV (Particle Image Velocimetry) methods. These results would be used for validation of standard k-${\varepsilon}$ turbulence model.

Numerical Simulation on Self-heating for Interlayer Tunneling Spectroscopy in $Bi_2Sr_2CaCu_2O_{8+x}$

  • Park, Jae-Hyun;Lee, Hu-Jong
    • Progress in Superconductivity
    • /
    • v.9 no.1
    • /
    • pp.18-22
    • /
    • 2007
  • For interlayer tunneling spectroscopy using a small stack of $Bi_2Sr_2CaCu_2O_{8+x}$ (Bi-2212) intrinsic junctions in a high-bias range, large self-heating takes place due to the poor thermal conductivity of Bi-2212. In this study, we numerically estimate the self-heating around a Bi-2212 sample stack for I-V or dI/dV-V measurements. Our results show that the temperature discrepancy between the Bi-2212 sample stack and top Au electrodes due to bias-induced self-heating is small enough along the c-axis direction of Bi-2212. On the other hand, the lateral temperature discrepancy between the sample stack and the Bi-2212 on-chip thermometer stack can be as large as ${\sim}20\;K$ for the highest bias required to observe the pseudogap hump structure. We thus suggest a new in-situ ac thermometry, employing the Au current-bias electrode itself deposited on top of the sample stack as the resistive thermometer layer, which is supposed to allow safe temperature measurements for the interlayer tunneling spectroscopy.

  • PDF

Construction and Comparison Measurement of Triple Point Water Cells for using Key Comparison and Evaluation of Uncertainty (핵심국제비교용 물의 삼중점 셀 제작과 비교 실험 및 불확도 평가)

  • Kang, Kee-Hoon;Kim, Yong-Gyoo;Gam, Kee-Sool
    • Journal of Sensor Science and Technology
    • /
    • v.13 no.2
    • /
    • pp.114-120
    • /
    • 2004
  • The $Comet{\acute{e}}$ Consultatif de $Thermom{\acute{e}}trie$ (CCT) under the Comete International des Poids et Measures (CIPM) has decided to perform the Key Comparison (KC) for triple point of water cells used as a reference fixed point of thermometry at the 21st meeting held at November 2001, and the Bureau International des Poids et Measures (BIPM) has been nominated as a KC coordinator. According to the KC protocol prepared by BIPM, KRISS performed the KC experiments and evaluate a uncertainty. The temperature difference between two reference cells for the Korea Research Institute of Standards and Science (KRISS) and a test cell for the transfer standard, which is moved to BIPM was 0.024 mK and the combined standard uncertainty evaluated 0.055 mK.

Remote Acoustic Sensing Methods for Studies in Oceanology

  • Akulichev, Victor A.;Bezotvetnykh, Vladimir V.;Burenin, Alexander V.;Voytenko, Evgeny A.;Kamenev, Sergey I.;Morgunov, Yury N.;Polovinka, Yury A.;Strobykin, Dmitry S.
    • Ocean Science Journal
    • /
    • v.41 no.2
    • /
    • pp.105-111
    • /
    • 2006
  • In this paper, the lines of investigation on a problem of the development of remote acoustic sensing methods in oceanology are formulated. This paper summarizes the results of investigations into the possibilities for monitoring temperature and flow fields in shallow seas. In the discussed experiments, the instrumentation being constituents of the complex for long-duration remote monitoring of marine medium climatic variability and that of the acoustic tomography of shallow sea dynamic processes is used. The acoustic instruments were located on the POI FEB RAS acousto-hydrophysical polygon (Pacific Oceanological Institute, Far Eastern Branch of the Russian Academy of Sciences) near the Gamov Peninsula. Acoustic receiving and transmitting systems operating with multiplex phase-manipulated signals (of M-codes) at frequency range 250-2500 Hz form the basis for this complex.

An Estimation of Water Structure and Dynamics in the East/Japan Sea Shelf Zone Using Acoustic Tomography

  • Akulichev, Victor Anatolievich;Bezotvetnykh, Vladimir Victorovich;Morgunov, Yury Nikolaevich;Polovinka, Yury Alexandrovich;Strobykin, Dmitry Sergeevich
    • Ocean and Polar Research
    • /
    • v.31 no.1
    • /
    • pp.1-9
    • /
    • 2009
  • When evaluating acoustic methods for measuring physical parameters in the ocean, economical and technical considerations are paramount. As an indirect method of estimating ocean dynamics, acoustic tomography has advantages over more conventional approaches. It allows the reconstruction of temperature and flow fields from the acoustic impulse time-of-flight measured along the rays propagating from the source to the receiver. However, many problems require complicated and expensive systems. To use the acoustic tomography method to best effect, developing hardware systems with sources and receivers mounted permanently on the sea bottom is crucial. Akulichev et al. presented some experimental results from shallow zones of the World Ocean that served as a motive for developing a multifunction system with acoustic hardware and software. Here we present technical features and the sea test results of the system.

Measuement of Temperature Probability Density Functions Variation in a Flame Near Fuel Nozzle of Gas Turbine Combustor Sector Rigs by CARS Thermometry (CARS 장치를 이용한 가스 터빈 연소기의 연료노즐 근처 화염 온도 분포 변화측정)

  • Park, Chul-Woung;Lee, Jong-Ho;Han, Yeoung-Min;Ko, Young-Sung;Lee, Kang-Yeop;Kim, Hyung-Mo;Lee, Soo-Yong;Yang, Soo-Seok;Lee, Dae-Sung;Jeon, Chung-Hwan;Chang, Young-June;Shin, Hyun-Dong;Hahn, Jae-Won
    • Journal of the Korean Society of Combustion
    • /
    • v.7 no.2
    • /
    • pp.7-14
    • /
    • 2002
  • The probability density functions (PDF) of temperature were measured by coherent anti-Stokes Raman Spectroscopy (CARS) in flames of gas turbine combustor sector rig of an aero-engine. The combustor was operated at simulated ground idle conditions with standard kerosene fuel. Temperature PDFs had been measured near fuel nozzle with change of rotation of a swirler and existence of a prefilmer. The characteristic features of temperature PDFs showed the variation of combustion configurations at four experimental conditions. Without a prefilmer, large recirculation of high temperature gas was expected in the co-flow condition and un vaporized fuel fragments were detected in the counter-flow condition. With a prefilmer, the enhanced mixing increased combustion intensity near fuel nozzle in the counter-flow condition and the flame was attached far from the fuel nozzle in the co-flow condition.

  • PDF

Realization of silver fixed-point and application for the high temperature platinum resistance thermometry using the gas-pressure controlled sodium heat-pipe furnace (가스압력조절식 나트륨 열관전기로를 이용한 은 고정점 실현과 고온백금저항온도 계측에의 응용)

  • Gam, K.S.;Choi, I.M.;Yang, I.;Kim, Y.G.
    • Journal of Sensor Science and Technology
    • /
    • v.18 no.2
    • /
    • pp.116-121
    • /
    • 2009
  • Pressure-controlled sodium heat pipe furnace was designed and fabricated, and its characteristics was investigated. Pressure control system was controlled within ${\pm}0.5\;Pa$ at 150 kPa and the stability of pressure was decreased to ${\pm}2.5\;Pa$, when the pressure-controlled system connected with the heat pipe. The melting curve of Ag fixed-point realized well by the adiabatic method using the pressure-controlled sodium heat pipe furnace and its accuracy showed ${\pm}2.27\;mK$ from the calculation of 20% to 80% at the plateau. The freezing curve of Ag fixed-point also realized and its plateau value was 2.23 mK lower than that of the melting curve.