A Basic Study on the Analysis Method of Thermography (Thermography의 분석방법에 관한 기초연구)

  • Lee, Hyuk-Jae;Park, Young-Jae;Oh, Hwan-Sup;Lee, Sang-Chul;Park, Young-Bae
    • The Journal of the Society of Korean Medicine Diagnostics
    • /
    • v.9 no.2
    • /
    • pp.110-122
    • /
    • 2005
  • Background: The basic concept of thermographic interpretation is the thermologic equality of both side in normal person. But both sides diseases were limited diagnostic values by thermographic interpretation, and this interpretation does not apply to the case in thermal temperature of each part of body. Nevertheless, the measurement conditions are not standardized. So, for its clinical applications are extended, we think that the measurement conditions are considered the individual variations. Objectives: The purpose of this study is to examine the optimum conditions thermal temperature of the time period and region are not effected by internal and external variables. Methods: After the subjects took off their clothes, the filming were repeatedly five times made on duration of 5minutes during 20minutes. We selected nine regions around acupoints including Yin dang[印堂, HN1], Sugu[水溝, GV26], Ch’ondol[天突, CV22], Chonjung[CV17], Chung-wan[中脘, CV12], Ch’onch'u[天樞 S25], No-gung[勞宮, P8], and calculated based on the utility of R.O.I.(Region of Integer) in our system these points temperature. We measured the optimal time period and region that has little variation of thermal temperature. Results: The results shows that the optimal time period is 20minutes after undressed, and the optimal region is the region around acupoints including Sugu[水溝, GV26]. Conclusions: we obtained the measurement conditions were considered the individual variations. And also, this study offers basic sources for that the measurement conditions would be standardized. Furthermore, based on this results, we expect that clinical applications using thermography would be extended.

  • PDF

A Case Report of Cold Hypersensitivity of Hands, Feet and Low Abdomen (수족, 하복부 냉증 환자의 치험 1례)

  • Yun, Young-Jin;Lee, Jin-Moo;Lee, Chang-Hoon;Jang, Jun-Bock;Lee, Kyung-Sub;Hwang, Deok-Sang
    • The Journal of Korean Obstetrics and Gynecology
    • /
    • v.27 no.1
    • /
    • pp.185-192
    • /
    • 2014
  • Purpose: The purpose of this study is to report the effect on cold hypersensitivity of hands, feet and low abdomen by Sasang constitutional treatment. For this purpose, the effects of a treatment were measured quantitatively using Digital Infrared Thermographic Imaging (DITI). Methods: It was a case of report, the patient was a 25-year-old female whose chief complaint was cold hypersensitivity of hands and feet and low abdomem. We treated the patient with Sasang constitutional treatment, and the effect of a treatment was evaluated by DITI. Results: After Sasang constitutional treatment, the differences of temperature of hands, feet and low abdomem were decreased on DITI screening, respectively. Conclusions: Sasang constitutional treatment on cold hypersensitivity of hands, feet and low abdomen is effective. Further studies on diagnosis tools of low abdomen cold hypersensitivity are needed.

Thermographic Defects Evaluation of Railway Composite Bogie (적외선열화상을 이용한 복합소재대차의 결함평가)

  • Kim, Jeong-Guk;Kwon, Sung-Tae;Kim, Jung-Seok;Yoon, Hyuk-Jin
    • Proceedings of the KSR Conference
    • /
    • 2011.05a
    • /
    • pp.548-553
    • /
    • 2011
  • The lock-in thermography was employed to evaluate the defects in railway bogies. Prior to the actual application on railway bogies, in order to assess the detectability of known flaws, the calibration reference panel was prepared with various dimensions of artificial flaws. The panel was composed of polymer matrix composites, which were the same material with actual bogies. Through lock-in thermography evaluation, the optimal frequency of heat source was determined for the best flaw detection. Based on the defects information, the actual defect assessments on railway bogie were conducted with different types of railway bogies, which were used for the current operation. In summary, it was found that the novel infrared thermography technique could be an effective way for the inspection and the detection of surface defects on bogies since the infrared thermography method provided rapid and non-contact investigation of railway bogies.

  • PDF

Tension Behavior of Nicalon/CAS Ceramic Composites (Nicalon/CAS 세라믹 복합재료의 인장특성)

  • Kim, Jeong-Guk;Kim, Weon-Kyong
    • Proceedings of the KSME Conference
    • /
    • 2004.11a
    • /
    • pp.232-237
    • /
    • 2004
  • The tension behavior of Nicalon/CAS glass-ceramic matrix composites was investigated. Infrared (IR) thermography was employed for two different types of $Nicalon^{TM}/CAS$ composites, i.e., cross-ply and unidirectional specimens. During tensile testing, an IR camera was used for in-situ monitoring of progressive damages of $Nicalon^{TM}/CAS$ samples. The IR camera provided the temperature changes during tensile testing. Microstructural characterization using scanning electron microscopy (SEM) was performed to investigate the fracture mechanisms of $Nicalon^{TM}/CAS$ composites. In this investigation, the thermographic NDE technique was used to facilitate a better understanding of the fracture mechanisms of the $Nicalon^{TM}/CAS$ composites during tensile testing.

  • PDF

Thermographic analysis of body surface temperature of patient with fatigue (피로 호소 환자의 전신 체열 특성)

  • Yoon, Tak Hyun;Lee, Ho Young;Joo, Jong Cheon
    • Journal of the Korean Institute of Oriental Medical Informatics
    • /
    • v.19 no.1
    • /
    • pp.36-42
    • /
    • 2013
  • Background : The aim of this study is assessing the adaption of thermography for fatigue. Method : Thermography was accomplished in three group classified fatigue group with disease, fatigue group without disease, non-fitigue group without disease. Results : Temperatures of fatigue group with disease was lower than those of the other groups. Conclusion : Thermography can be used to diagnosing and assessing the fatigue patients.

  • PDF

Detecting of the defects of pavement of a road by using infrared thermography (열화상 비파괴 검사법을 이용한 도로포장 결함 검출)

  • Sim, Jun-Gi;Kim, Ki-Hyun
    • Journal of the Korean Society for Advanced Composite Structures
    • /
    • v.6 no.3
    • /
    • pp.69-76
    • /
    • 2015
  • The purpose of this paper is to find an limitation to detect the defect of damaged asphalt pavement structures for infrared thermography. We use heat source of a natural light to detect the defect efficiently. The heat source was applied to the asphalt specimens. Four asphalt specimens were used: one was the asphalt containing depth of 1cm internal timber, two was the asphalt containing depth of 2cm internal void, Three was the asphalt containing depth of 3cm internal timber and four was not the asphalt containing internal timber. It was found that the depth of 3cm internal timber could be detected by this method. In addition, we used the image processing to make the damage zone displayed clear in the image obtained from the thermographic operation.

DIGITAL INFRARED THERMAL IMAGING IN OSTEOPOROSIS

  • Lee, Kyung-Sub;Kim, Yong-Suk
    • Journal of Oriental Medical Thermology
    • /
    • v.1 no.1
    • /
    • pp.1-6
    • /
    • 2002
  • This study examined the relationship between bone mineral density and DITI in the diagnosis of osteoporosis. An analysis was performed on the thermographic findings of 20 patients without osteoporosis, 20 with osteopenia and 20 with osteoporosis at the Kangnam Korean Hospital, KyungHee University, Seoul, Korea, from June 1998 to February 1999. The osteoporosis was measured by LUNAR PIXI and the body temperature was assessed by DITI. Thermogrphic measurements were performed on 4 areas(acupuncture point: CV12, CV4, BL23 and BL26). All data were coded for computer analysis and significances were tested by Duncan test. There was no significant difference in age among the three groups of patients. DITI revealed the significant hypothermia (p<0.001) on the osteoporosis patients compared with osteopenia and normal bone density patients. It is believed that DITI may be a favorable alternative to the diagnosis of osteoporosis.

  • PDF

A clinical report on the acne treatment with AMTS (자동 미세침(AMTS)을 이용한 여드름 치험례)

  • Seong, Eun-Jin;Jo, Eun-Hee;Park, Min-Cheol
    • The Journal of Korean Medicine Ophthalmology and Otolaryngology and Dermatology
    • /
    • v.23 no.3
    • /
    • pp.236-246
    • /
    • 2010
  • Background & Objective : Microneedle therapy system(MTS) is popular these days. However, there are few reports about it in oriental medicine academia. This study is performed to evaluate the effect of MTS on acne patients. Methods : This study was conducted to evaluate the effect of MTS. Seven patients were treated for 7 weeks. Follow-up was performed after the treatment with Janus facial analysis system, skindex-29 and Digital Infrared Thermographic Imaging machine. Satisfaction degree and inconvenience were asked from the patients. Results and Conclusions : Microneedle therapy system(MTS) was good for acne like pore, wrinkle, spot(polarised), sebum, porphyrin and skin tone. Especially it had excellent effects on sebum and porphyrin.

Remarks on of Optimizations of Time-Resolved Pulse Thermography for Nondestructive Testing Evaluations (비파괴검사 평가를 위한 시간-분해 펄스열화상의 최적화에 관한 제고)

  • Kim, Wontae
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.33 no.2
    • /
    • pp.226-231
    • /
    • 2013
  • 펄스 열화상에서 서모그램 등 데이터의 플롯에 의해 표시되어지는 로그-로그 플롯을 활용해서 특정하게 정류(rectification)하여 펄스 서모그램을 잘 사용하도록 정의하고 열화상 신호복원(thermographic signal reconstruction; TSR) 기법에 의해 실험 데이터를 피팅하도록 한다, 이와 같은 물리적인 해석 및 수학적 대수기법에 의해 펄스열화상은 단순하면서도 효율적인 정규화가 가능하게 될 수 있다. 펄스열화상의 최적화는 로그대수 유도로 비교되는 콘트라스트(contrast)의 초기 검출과 TSR의 사용이라는 두 가지 돋보이는 접근 방법에 기반하여 이루어진다. 펄스자극열화상을 최적화하기 위해서 두 개의 매개변수, 즉 결함 콘트라스트의 신호 대 잡음비와 추출에 대한 선인식을 고려하는 것이 필요하다.

Infrared thermographic analysis of temperature rise on the surface of Buchanan plugger.

  • Choi, Sung-A;Hwang, In-Nam;Oh, Won-Mann
    • Proceedings of the KACD Conference
    • /
    • 2001.11a
    • /
    • pp.590.2-590
    • /
    • 2001
  • This study was performed to evaluate the temperature rise on various position of the Buchanan plugger, the peak temperature of plugger's type and the temperature change by its touching time of heat control spring. The System B (Model 1005, Analytic Technologies, USA) and the Buchanan pluggers of F, FM, M and ML are used for this study. The temperature was set to $200^{\circ}C$. The power level on it was set to 10. The heat control spring was touched for 1,2,3,4 and 5 seconds respectively. (omitted)

  • PDF