• Title/Summary/Keyword: thermocouple

Search Result 361, Processing Time 0.03 seconds

Fabrication of $ZrB_2$ Ceramics for Thermocouple Protective Tubes by SHS Process (SHS 공정에 의한 열전대 보호관용 $ZrB_2$ 세라믹스의 제조)

  • 곽철상;김상배;이윤복;박홍채;오기동
    • Journal of the Korean Ceramic Society
    • /
    • v.34 no.11
    • /
    • pp.1165-1172
    • /
    • 1997
  • ZrB2 powders were prepared from a mixture of ZrO2, B2O3 and Mg by self-propagating high temperature synthesis method. The combustion product was successfully obtained from a mixture of ZrO2:B2O3:Mg=1:2:8.5 molar ratio. By-product, MgO was effectively removed by leaching with 1M HCl solution at 9$0^{\circ}C$ for over 5hours. After leaching, the Mg content was 0.86~1.42 wt%, and the mean particle size was 4.72${\mu}{\textrm}{m}$. The addition of 7.5 wt%(14Ni:1.0C) as a sintering aid greatly densified ZrB2 bodies compared with that of only Ni. The ZrB2 sintered bodies containing 7.5 wt%(14Ni:1.0C) was 94.3% of the theoretical density. In this case, ZrB2 existed as a major phase and had a bend strength of 300 MPa and a vickers hardness of 2000 kg/$\textrm{mm}^2$.

  • PDF

An Experimental Study on the Drop Size and the Combustion Characteristics around the Bluff-body (보염기 주위의 연료액적크기와 연소특성에 관한 실험적 연구)

  • Hwang, S.H.;Kim, D.J.
    • Journal of ILASS-Korea
    • /
    • v.8 no.3
    • /
    • pp.41-48
    • /
    • 2003
  • This work was performed to investigate the distribution of the fuel droplet size around the bluff-body and the combustion characteristics. The bluff-body is used fur the purpose of increasing the combustion efficiency by stabilizing the flame. Diameters of the bluff-body in this experiment are 6, 8, and 10mm and the impingement angles are $30^{\circ},\;60^{\circ}\;and\;90^{\circ}$. The measurement points were at the distances of 20 and 30 mm axially from the nozzle. The geometry of the bluff-body influenced the spray shape and the combustion characteristics. The SMD was acquired by image processing technique (PMAS), and the mean temperatures were measured by thermocouple. In the condition of ${\theta}=60^{\circ}$, the values of SMD are not greatly varied compared to the other conditions. As the angle of bluff-body was increased, the high temperature region was wider along radial direction. When the air-fuel ratio was larger than 5.2, the NOx concentration was decreased, and an increase in the diameter of the bluff-body decreased the NOx of emission.

  • PDF

Performance of the heat flux sensor using thermoelectric semiconductor material (半導體 熱電材料를 利용한 熱流束 測定 센서의 性能)

  • 황동원;정평석;주해호
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.12 no.3
    • /
    • pp.622-629
    • /
    • 1988
  • In order to improve the sensitivity of the wafer type heat flux sensor, some heat flux sensors were manufactured and examined by using thermoelectric semiconductor material (bismuth telluride) whose Seebck coefficient is much larger than those of metallic thermocouple materials. Because the thermoelectric element cannot be bended or welded, a peculiar sensor structure and manufacturing process were designed. As a result, it is revealed that the characteristic sensitivity of the manufactured sensor is about 10 times larger than that of marketed sensor even though there are some troubles in stiffness for reciprocal use. If we make this kind of sensors smaller and thinner, it will be a useful method to measure the local heat flux from the surface of complex configuration.

The Effect of Exhaust Performance by according to Active Muffler Valve Spring (능동형 소음기의 밸브 스프링이 배기 성능에 미치는 영향)

  • Kong, T.W.;Yi, C.S.;Chung, H.S.;Jeong, H.M.;Suh, J.S.;Chun, Y.H.
    • Proceedings of the KSME Conference
    • /
    • 2001.11b
    • /
    • pp.682-687
    • /
    • 2001
  • This study represents effect of exhaust performance by according to active muffler valve spring. The experimental parameter were divided engine speed and torsion coil spring constant. The sound pressure level was generally low at engine speed 2000-2500rpm but That was showed the lowest at spring constant k=0.75. Flow speed of exhaust gas was showed the fast at spring constant k=0.75 but the low value was showed at k=0.97. It was contained a rather low concentration of carbon monoxide(CO) at engine speed 2000-2500rpm and k=0.81, low concentration of hydrocarbon(HC) at spring constant k=0.81 but that was high at spring constant k=0.97. A conclusion based on FFT analysis was generally low concentration value at k=0.79 and k=0.81. The temperature distributions into the muffler was shown similar conditions. Heat transfer was well spreaded at thermocouple No.8 because valve was opened.

  • PDF

Effect of Air Gap Thickness on Top Heat Loss of a Closed-loop Oscillating Heat Pipe Solar Collector

  • Nguyen, Kim-Bao;Choi, Soon-Ho;Yoon, Doo-Ho;Choi, Jae-Hyuk;Oh, Cheol;Yoon, Seok-Hun
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.33 no.7
    • /
    • pp.994-1002
    • /
    • 2009
  • In this paper, effect of air gap thickness between absorber plate and glass cover on top heat loss of a closed loop oscillating heat pipe (CLOHP) solar collector was investigated. The CLOHP, which is made of copper with outer diameter of 3.2mm and inner diameter of 2.0mm, comprises 8 turns with heating, adiabatic and cooling section. The heating section of the heat pipe was attached to absorber plate which heated by solar simulator simulated by halogen lamps. The cooling section of the heat pipe was inserted into collector's cooling section that made of transparent acrylic. Temperatures of absorber plate, glass cover, and ambient air measured by K-type thermocouple and were recorded by MV2000-Yokogawa recorder. Top heat loss coefficients and top heat loss of the collector corresponding to some cases of air gap thickness were determined. The result of experiment shows the optimal air gap thickness for minimum top heat loss of this solar collector.

Combustion Characteristics of the Atomized Hydrocarbon Liquid-fuel Spray Injected through a Slit-jet Nozzle (Slit-jet 노즐을 통해 분사되는 탄화수소계 액체연료 분무의 연소특성)

  • Kim, Min Sung;Kim, Jeong Soo
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.20 no.1
    • /
    • pp.43-49
    • /
    • 2016
  • An experimental study was performed to investigate the combustion characteristics of the liquid hydrocarbon fuel atomized by an ultrasonic oscillator. Configuration of the flame was caught by the DSLR camera, and images were analyzed in detail through a post-processing. Temperature of the flame zone was measured using thermocouple. It is resulted that the flame area is proportional to the mass flow rate of carrier gas as well as the voltage applied to the ultrasonic oscillator. Temperature of the flame zone is measured and analyzed according to variation in the operating condition of the burner, too.

Direct Observation on Pyrolysis of Some Plastics

  • Takasu, Tomio;Itou, Hideyuki;Shibata, Etsuro;Kasai, Eiki;Nakamura, Takashi
    • Proceedings of the IEEK Conference
    • /
    • 2001.10a
    • /
    • pp.742-745
    • /
    • 2001
  • Plastics are one of difficult materials for recycling due to their characteristics in use. Recycling ratio of waste plastics was around 40% in last year in Japan, which includes energy recovery. Feed stock recycling and mechanical recycling are not easy because of additives in commercial plastics. Then, pyrolysis treatments have been done to recovery energy. Although plastics are easy to fire, complete combustion of them is not easy if anti-firing agents are added especially. Therefore, researches on pyrolysis or combustion behaviors of plastics containing additives are important from a view point recycling of plastics. Direct observation of popular plastics like polystyrene (PS), polycarbonate (PC), polyphenyle ether (PPE) and polyvinyl chloride (PVC) to investigate their pyrolysis behaviors in the present study. In case of PS, melting and gas evolution started at 9$0^{\circ}C$ and 39$0^{\circ}C$ respectively. And combustion finished at 445$^{\circ}C$. On the other hand, more than $600^{\circ}C$ and sufficient oxygen are required for complete combustion of PC and PPE.

  • PDF

Prediction of temperature using equivalent thermal network in SPMSM (열 등가회로를 이용한 SPMSM 전동기의 온도 예측)

  • Kim, Do-Jin;Kwon, Soon-O;Jung, Jae-Woo;Hong, Jung-Pyo
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.792-793
    • /
    • 2008
  • This paper deals with the temperature calculation using equivalent thermal network for surface mounted permanent magnet synchronous motor(SPMSM) under the steady-state condition. In the equivalent thermal network, heat sources are generated from copper loss and iron loss. Heat transfer consists of conduction, convection and radiation. However, radiation is neglected in this paper because its effect is much smaller than others. Although the heat transfer coefficient in conduction use material property, heat transfer coefficient in convection is difficult to measure due to the atmosphere and ambient condition. Temperatures of each region in SPMSM are measured by thermocouple in operating condition and the thermal resistances of convection are calculated by kirchhoff's current law(KCL) and experimental result. In order to verify the validation and reliability of the proposed equivalent thermal network, temperature which is calculated other load condition is compared with experimental results. Accordingly, temperatures of each region in other SPMSMs will be easily predicted by the proposed equivalent thermal network.

  • PDF

Soot Concentration and Temperature Measurements in Laminar Ethylene Jet Double-concentric Diffusion Flames (동축 이중 에틸렌 확산화염의 매연 농도분포 및 온도 측정)

  • Lee, Gyo-U;Jeong, Jong-Su;Hwang, Jeong-Ho
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.26 no.3
    • /
    • pp.402-409
    • /
    • 2002
  • Experiments were performed with double-concentric diffusion flame(DDF) in order to investigate the characteristics of soot formation and temperature distributions. The flame size and shape of the DDF are similar to those of the well-known normal co-flow diffusion flame(WF), except the formation of a tiny inverse flame near the central tube exit. A laser light extinction technique was used to measure the soot volume fractions. The temperature distributions in the flame were measured by rapid insertion of a R-type thermocouple. Soot concentrations along the flame axis of the DDF were higher than those of the NDF. However, the maximum soot volume fraction of the DDF along the periphery of the flame was lower than that of the NDF. It is mainly due to the effect of nitrogen-dilution from the inner air. Measured temperature distribution explains these trends of soot concentration. The temperature along the flame axis was also higher in DDF than that of the NDF. However, the flame temperatures at the flame front of the two flames were almost same regardless of the inner flame. This phenomenon means that the inverse flame inside the DDF did not affect on the flame structure including the temperature and soot concentration, except the region around the flame axis.

Film Cooling from Two Rows of Holes with Opposite Orientation Angles(II) -Blowing Ratio Effect- (반대방향의 방향각을 갖는 2열 분사구조의 막냉각 특성(II) -분사비의 영향-)

  • Ahn, Joon;Jung, In-Sung;Lee, Joon-Sik
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.25 no.8
    • /
    • pp.1131-1139
    • /
    • 2001
  • Experimental results are presented, which describe the effect of blowing ratio on film cooling from two rows of holes with opposite orientation angles. The inclination angle is fixed at 35°, and the orientation angles are set to be 45°for the downstream row, and -45°for the upstream row. The studied blowing ratios are 0.5, 1.0 and 2.0. The boundary layer temperature distributions are measured using thermocouple at two downstream locations. Detailed adiabatic film cooling effectiveness and heat transfer coefficient distributions are measured with TLC(Thermochromic Liquid Crystal). The adiabatic film cooling effectiveness and heat transfer coefficient distributions are discussed in connection with the injectant behaviors inferred from the boundary layer temperature distributions. Film cooling performance, represented by heat flux is evaluated from the adiabatic film cooling effectiveness and heat transfer coefficient data. The results show that the investigated geometry provides improved film cooling performance at the high blowing ratios of 1.0 and 2.0.