• 제목/요약/키워드: thermo coil

검색결과 14건 처리시간 0.027초

The Applications of the Duplex Stainless Steel as Hyperthermia Materials

  • Kim, Young-Kon
    • 한국재료학회:학술대회논문집
    • /
    • 한국재료학회 2009년도 춘계학술발표대회
    • /
    • pp.7.1-7.1
    • /
    • 2009
  • The use of Duplex stainless steel as a thermo-implant categorizes into two clinical applications: hyperthermia and thermal ablation or destruction. The goal of hyperthermia is to destroy the heat-sensitive abnormal cells and minimize normal cell death maintaining heat between $42^{\circ}C$ and $46^{\circ}C$. Thermal ablation takes place when the local tissue temperature increases greater than $46^{\circ}C$. This elevated temperature denatures protein irreversibly resulting cellular death. The author introduced several thermo-implants such as thermo-rod, thermo-stent, thermo-coil and thermoacupuncture-needle. Those thermo-implants are made of duplex stainless steel which can produce regulated heat by itself within an induction magnetic field. Thermal ablation characteristics of the thermo-rod on tumor hyperthermia depend on configurations of the thermo-rods and the magnitude of the induction magnetic strength. The exothermic properties of the thermo-implants can be characterized using the calorimetric test and the heat affected zone(HAZ) analyses in vitro. Thermal radiation studies using thermo-coils and thermo-stents show the capability of the occlusion of animal blood vessels and inhibiting the proliferation of the abnormal smooth muscle cell growth and inflammatory cell reactions maintaining the heat between $42^{\circ}C$ and $46^{\circ}C$ minimizing a normal cell death in the study on external iliac artery of the New Zealand White (NZW) rabbit. Thermal stimulation study using thermo-acupuncture needles suggests the potential applications of the automated acupunctural therapies.

  • PDF

Tunable Channel Spacing of Dual-wavelength Erbium-doped Fiber Ring Laser using a Single Fiber Bragg Grating with Two Coil Heaters

  • Sohn, Kyung-Rak;Kim, Hyung-Pyo
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제33권1호
    • /
    • pp.153-158
    • /
    • 2009
  • Stable and tunable dual-wavelength erbium-doped fiber ring laser(EDFL) using a single fiber Bragg grating(FBG) and two coil heaters is proposed and demonstrated. Installing two identical coils into a single FBG, the FBG is symmetrically divided into two different portions. While a current supply to the coil, the refractive index of the FBG under the coil is changed. The FBG can operate as a joint of two different FBGs. Due to the thermo-optic effect of a fiber, the resonance wavelength split into two peaks. The spacing between two adjacent channels was changed as much as the difference of heating power. It was tuned up to 3 nm of wavelength under the electrical power with a 1000 mW. Moreover, the lasing wavelength can be individually tuned without influencing to the adjacent channel.

Thermo Motor 설계 및 특성연구 (The study on the Characteristics and Design of the Thermo Motor)

  • 구대현;김진봉;노규석
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1993년도 하계학술대회 논문집 B
    • /
    • pp.1035-1037
    • /
    • 1993
  • Thermo motor that uses driving part as heating part is different from general fan heater. As it uses energy that drives rotor and generate heat at the same coil, it is simpler and cheaper than general fan heater. In this study, shaded-pole motor was used that is low cost and simple in spite of low efficiency.

  • PDF

KSTAR(Korea Superconducting Tokamak Advanced Research) 냉각 시스템에 대한 열해석 연구 (A Study on Thermo-Hydraulic Analysis for KSTAR(Korea Superconducting Tokamak Advanced Research) Cooling Line System)

  • 김홍원;하지수;김대순;이종석;최창호
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2003년도 추계학술대회
    • /
    • pp.296-301
    • /
    • 2003
  • A study on the engineering design and numerical thermo-hydraulic analysis for KSTAR TF coil structure cooling system has been conducted. The numerical analyses have been done to verify the engineering design of cooling using the commercial code, FLUENT and in-house code for calculating helium properties which varies with cooling tube's heat transfer. Through the engineering design process based on the steady heat balance concepts, the circular stainless steel tube with inner diameter of 4 mm for TF coil has been selected as cooling tube. From normal operation mode analysis results, total 28 cooling tubes were finally chosen. Also, three dimensional cool down analysis for TF coil with designed cooling tube was satisfied with next three design criteria. First is cooling work termination within a month, second is maximum temperature difference within 50 K in TF coil structure and third is exit helium pressure above 2 bar. Consequently, these cool down scenario results can afford to adopt as operating scenario data when KSTAR facilities operate.

  • PDF

Analysis of Temperature Dependence of Thermally Induced Transient Effect in Interferometric Fiber-optic Gyroscopes

  • Choi, Woo-Seok
    • Journal of the Optical Society of Korea
    • /
    • 제15권3호
    • /
    • pp.237-243
    • /
    • 2011
  • Thermal characteristics, such as diffusivity and temperature induced change in the fiber mode index of rotation sensing fiber coil are critical factors which determine the time varying, thermo-optically induced bias drift of interferometric fiber-optic gyroscopes (IFOGs). In this study, temperature dependence of the transient effect is analyzed in terms of the thermal characteristics of the fiber coil at three different temperatures. By applying an analytic model to the measured bias in the experiments, comprehensive thermal factors of the fiber coil could be extracted effectively. The validity of the model was confirmed by the fact that the extracted values are reasonable results in comparison with well known properties of the materials of the fiber coil. Temperature induced changes in the critical factors were confirmed to be essential in compensating the transient effect over a wide temperature range.

Coil-to-globule transition of thermo-responsive γ-substituted poly (ɛ-caprolactone) in water: A molecular dynamics simulation study

  • Koochaki, Amin;Moghbeli, Mohammad Reza;Nikkhah, Sousa Javan
    • Current Applied Physics
    • /
    • 제18권11호
    • /
    • pp.1313-1319
    • /
    • 2018
  • The coil-to-globule behavior of poly{${\gamma}$-2-[2-(2methoxyethoxy)ethoxy]ethoxy-3-caprolactone} (PMEEECL) as a ${\gamma}$-substituted poly (${\varepsilon}$-caprolactone) was investigated via atomistic molecular dynamics (MD) simulation. For this purpose, radius of gyration, end-to-end distance and radial distribution function of the chain in the presence of water were calculated. Consequently, the lower critical solution temperature (LCST) of PMEEECL chain at which the coil-to-globule transition takes place, was determined in each calculated parameter curve. The simulation results indicated that the LCST of PMEEECL was occurred at close to 320 K, which is in a good agreement with previous experimental results. Additionally, the appearance of sudden change in both Flory-Huggins interaction parameter (${\chi}$) and interaction energy between the PMEEECL chain and water molecules at about 320 K confirmed the calculated LCST result. The radial distribution function (RDF) results showed that the affinity of the PMEEECL side chain to water molecules is lower than its backbone.

Test Result Analysis of a 1MW HTS Motor for Industry Application

  • Baik, S.K.;Kwon, Y.K.;Kim, H.M.;Lee, E.Y.;Kim, Y.C.;Park, H.J.;Kwon, W.S.;Park, G.S.
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제11권2호
    • /
    • pp.33-36
    • /
    • 2009
  • A 1 MW class HTS (High-Temperature Superconducting) synchronous motor has been developed. This motor is aimed to be utilized for industrial application such as large motors operating in large plants. The HTS field coil of the developed motor is cooled by way of neon thermo siphonmechanism and the stator (armature) coil is cooled by water through hollow copper conductor. This paper also describes evaluation of some electrical parameters from performance test results of our motor, which was conducted at steady state in generator mode and motor mode. Open and short circuit tests were conducted in generator mode while a 1.1 MW rated induction machine was rotating the HTS machine. Electrical parameters such as mutual inductance and synchronous inductance are deduced from these tests. Load test was done upto rating torque during motor mode and efficiency was measured at each load torque.

우(牛) 유래(由來) 장독소(腸毒素) 산생(産生) 대장균(大腸菌)에 대하여 (Studies on Enterotoxigenic Escherichia coli Isolated from Cattle)

  • 이강록;최원필
    • 대한수의학회지
    • /
    • 제26권1호
    • /
    • pp.69-77
    • /
    • 1986
  • The purpose of this study was the examination for presence of K99 antigen (K99), enterotoxigenicity, 0-groups, colicin and antibiotic susceptibility among E. coil isolated from calves and cows. A total of 49(18.7%) among 262 strains, isolated from 30(26.5%) out of 113 calves and cows, possesed K99, and thirty three of 49 $K99^+$ strains produced ST. Of the strains of diarrheal calf origin which less than 15 days old, a high correlation was observed between enterotoxigenic ability and K99: 92.3% of the $K99^+$ strains produced heat stable enterotoxin(ST). In O group typing of 33 $ST^+$ strains, they belonged to O20(48.4%), O8(9.1%), O9(6.1%), O139(6.1%), O149(6.1%), O101(3.0%), O115(3.0%), except six which were untypable or autoagglutinable. Of 262 E. coil isolates, 30 strains(13.3%) produced colicin and K99 were detected in 6 strains. One hundred eighty eight strains(71.8%) of 262 E. coil isolates were resistance to ampicillin, chloramphenicol, gentamicin, kanamycin, streptomycin, tetracycline, alone or in combination thereof. One hundred and fourteen(60.6%) out of 188 drug resistance strains carried R factor($R^+$) which were transferable to the recipients by conjugation. Sixty five $R^+$ strains(57.0%) carried thermo-sensitive R plasmid.

  • PDF

HPT 방식의 온열침대 디자인 개발에 관한 연구 (A Study on Thermo-Bed Design Development of HPT System)

  • 이봉규
    • 한국가구학회지
    • /
    • 제22권1호
    • /
    • pp.72-81
    • /
    • 2011
  • These days, beds have been developed not as furniture to sleep in but Healthcare Furniture. The function of heating, non-electronic-waves and far-infrared rays have been added. Also, eco-friendly materials such as stone, mud, rubber and wood are combined to them together with the radiation-heating method using heat conduction through electronic coil and hot water circulation. Modern people suffer from stress and fatigue. The hot issue is "health." Focused on the health, the development of design for beds considering the influence electronic waves, anions, deep sleep and the density of toxic materials have on human bodies has become urgent. In this study, the trend, specification and efficiency of the functional health-related electronic coil technology are analyzed. Through the analysis, the environmental standards are set. According to them, technology, eco-friendly materials and additional functions for the development of the design are considered. Also, the government is promoting the IEC international standardization for the Korean traditional floor heating style beds. In preparation for that, we adopted new HPT method technology. It enables non-electronic-waves, low electricity and stable temperature maintenance control for the warm top and the cool bottom. Also, the head boards and the frames of the beds can be separated. Through this separation, the beds can be easily moved or installed. Eco-friendly materials such as Hinoki cypress wood and red clay and the existing tables function are combined to the head boards so they can be used as drawers and display shelves. If they are used as separate items, they can be used as covers. This is how we suggest the design for the heating beds.

  • PDF

Hi-CON/H2 BAF와 HNx BAF의 소둔사이클 제어온도에 관한 연구 (A Study on Annealing Cycle Control Temperature of Hi - CON/2 BAF and HNx BAF)

  • 김문경
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제18권1호
    • /
    • pp.114-122
    • /
    • 1994
  • A cold temperature control system for the BAF(batch annealing furnace) has been established in order to reduce energy consumption to imrpove productivity and stabilize the properties of products. Therefore we confirmed a relation between annealing cycle time and atmospheric gas, changing annealing cycle time according to BAF temperature with time during heating and actual temperature measurements cold spot during soaking. The results of the temperature variation effect on the batch annealing are as follows. 1) Cooling rate is increasing gradually with increasing atmospheric gas flow, but heating rate is hardly increasing without atmospheric gas component. Heating time is reduced to one half with increasing atmospheric gas flow rate and changing of atmospheric gas component from HNx to Ax gas and annealing cycle time is reduce to 2.7 times. 2) With enlarging the difference between furnace temperature and soaking temperature at the HNx BAF, heating time becomes short, but cooling time is indifferent. 3) If temperature difference of 300.deg. C in the temperature change of cold spot according to the annealing cycle control temperature, Hi-CON/H2BAF is interchanging at each other at 26hours, but HNxBAF at 50 hours. 4) Soaking time at batch annealing cycle determination is made a decision by the input coil width, and soaking time for quality homogenization of 1219 mm width coil must be 2.5 hours longer then that of 914mm width coil for the same coil weight at Hi-CON/H2BAF. But, it is necessary to make 2 hours longer at HNxBAF.

  • PDF