• Title/Summary/Keyword: thermionic cathode

Search Result 7, Processing Time 0.022 seconds

Emission Profile Studies of Thermionic Cathodes and Field Emitters

  • Tawa, Yasuhiro;Kai, Junjiro;Tama, Masayoshi;Ijima, Kenji;Saito, Tsunenari
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2002.08a
    • /
    • pp.371-375
    • /
    • 2002
  • Emissions of thermionic cathodes and field emitters were studied using a cathode emission profiler which works based on the anode scanning method. Findings about impregnated cathodes in thermal activation and gas poisoning processes are shown. Effects of surface treatments for field emitters are studied from the viewpoint of emission profiles and characteristics of the emitters.

  • PDF

Experimental for Performance of electron 9un cathode electrode (Y-824) characteristics (전자총 캐소드전극(Y-824)의 특성실험)

  • Son, Y.G.;Kwon, S.J.
    • Proceedings of the KIEE Conference
    • /
    • 2006.07c
    • /
    • pp.1552-1553
    • /
    • 2006
  • A thermionic gun of injector linac for pohang accelerator laboratory is required to generate beam pulse width less than 1 nsec. The gun uses cathode-grid assembly(EIMAC Y824) and operates up to 80 kV anode voltage. In order research characteristics of the electron gun, emission current from gun wear measured by the wall current monitor. In this paper the pulser system and characteristics of the emission current in region from 30 mA to 15 A are described.

  • PDF

Ignition Characteristics Analysis of Pseudospark Discharge using Hybrid Fluid-Particle(Monte Carlo) Method (복합 유체-입자(몬테칼로)법을 이용한 유사스파크 방전의 기동 특성 해석)

  • 주흥진;심재학;강형부
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1997.11a
    • /
    • pp.270-274
    • /
    • 1997
  • The numerical model that can describe the ignition of the pseudospark discharge using hybrid fluid-particle method has been developed. The evolution process of the discharge has been divided into four phases along the potential distribution. After the plasma enters in the hollow cathode, the confining effect which is one of hollow cathode properties occurs and the electron current on anode rises rapidly. As the plasma expands successively, the sheath contracts and as the electric field in the sheath increases, the field-enhanced thermionic emission(Schottky emission) occurs. From numerical results, the physical mechanism that causes the rapid current rise in the ignition of the pseudospark discharge could be identified.

  • PDF

Effects on Addition of Metal Oxides with Low Workfunctions on the Ca-Sr-Ba Oxide Cathodes for VUV Ionizers (VUV 이오나이저용 Ca-Sr-Ba계 산화물 캐소드에 낮은 일함수를 갖는 금속산화물 첨가의 영향)

  • Park, Seung-Kyu;Lee, Jonghyuk;Kim, Ran Hee;Jung, Juhyoung;Han, Wan Gyu;Lee, Soo Huan;Jeon, Sung Woo;Kim, Dae Jun;Kim, Do-Yun;Lee, Kwang-Sup
    • Korean Journal of Materials Research
    • /
    • v.29 no.4
    • /
    • pp.241-251
    • /
    • 2019
  • There are several manufacturing techniques for developing thermionic cathodes for vacuum ultraviolet(VUV) ionizers. The triple alkaline earth metal emitters(Ca-Sr-Ba) are formulated as efficient and reliable thermo-electron sources with a great many different compositions for the ionizing devices. We prepare two basic suspensions with different compositions: calcium, strontium and barium. After evaluating the electron-emitting performance for europium, gadolinium, and yttrium-based cathodes mixed with these suspensions, we selected the yttrium for its better performance. Next, another transition metal indium and a lanthanide metal neodymium salt is introduced to two base emitters. These final composite metal emitters are coated on the tungsten filament and then activated to the oxide cathodes by an intentionally programmed calcination process under an ultra-high vacuum(${\sim}10^{-6}torr$). The performance of electron emission of the cathodes is characterized by their anode currents with respect to the addition of each element, In and Nd, and their concentration of cathodes. Compared to both the base cathodes, the electron emission performance of the cathodes containing indium and neodymium decreases. The anode current of the Nd cathode is more markedly degraded than that with In.

The conductive characteristic of oil-immersed paper (유침절연지의 도전특성)

  • 성영권;이헌용
    • 전기의세계
    • /
    • v.25 no.2
    • /
    • pp.87-91
    • /
    • 1976
  • Experimentally to investigate the conductive characteristic of oil-immersed paper, we observed the leakage current-voltage characteristic of oil-immersed paper, the temperature dependence of ionization rate and the effect of metal electrode on the leakage current. The results showed that the leakage current-voltage characteristic generally followed the experimental equation i=i$_{0}$ exp (K.root.E) and the slope K did not change by the temperature and electric strength, but only when the direct voltage was applied. And also the leakage current seemed to depend on the work function of metal electrode. From the above results we concluded that the deterioration of oil-immersed paper was not only caused by the thermionic emission from the cathode but also by the conductive property of oil-immersed paper in itself and the work function of metal electrode.e.

  • PDF

Property of Focal Spot of Electron Beam Depending on the Anode Angle of X-ray Tube Using a Finite Element Method (유한요소법을 이용한 X-선관 양극각도에 의존하는 전자빔 초점 특성 연구)

  • Park, Tae-Young;Noh, Young-Il;Lee, Sang-Suk;Park, Rae-Jun;Kim, Ki-Seon
    • Journal of the Korean Magnetics Society
    • /
    • v.25 no.2
    • /
    • pp.52-57
    • /
    • 2015
  • The focal spot of electron beam depending on the anode angle in the structure and major parts of the X-ray tube was investigated by the OPERA-3D/SCALAR simulation program. The simulation worked on four spaces with with two spaces, including anode and cathode of X-ray tube, by applying the finite element method analysis. The analytical model and dimension for the emission orbit of thermal electrons made from one filament of the focused X-ray cathode is affected to the penumbra of detector for the X-ray depending on any real focal spot size. The model shape of focusing cap and focusing tube with an anode target angle and a cathode filament is analyzed by the current density distribution of thermal electrons. The focusing width of thermal electrons for the X-ray tube depended on the anode angle (${\theta}$). The focusing value of electron beams at a region of anode angle having $10^{\circ}{\sim}17^{\circ}$ maintained to below value of $70{\mu}m$. The minimum focal size of the electron beam was $40{\mu}m$ at an anode angle of $15^{\circ}$. The focused X-ray tube of many variables depended on the thermionic emission of hot electrons from the target trajectory. The focusing tube will contribute to the real design of X-ray for the development of future diagnosis medical device.

Development of the impregnated dispenser cathode for thermionic emission electron gun

  • Hong, Yong-Jun;Lee, Seong;Sin, Jin-U
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2016.02a
    • /
    • pp.182.1-182.1
    • /
    • 2016
  • 전자빔의 운동에너지를 변화시켜 전자기장을 발생시키는 진공튜브 장치는 기본적으로 전자빔 발생부인 전자총을 핵심 구성부로 사용한다. 이러한 전자총을 이용하는 진공튜브로는 핵융합을 위해 플라즈마 가열용의 RF를 발생시키는 자이로트론 튜브와 방사광 가속기에서 전자를 가속시키는데 이용되는 클라이스트론 튜브 등이 있으며, 군사적으로는 레이더를 비롯하여 유도미상일에 들어가는 탐색기, 전투기에서 사용되는 송수신용 마이크로파 발생장치 등의 핵심부품인 진행파관 진공튜브 등이 있다. 이러한 응용분야에서는 기본적으로 고출력의 전자파를 필요로 하기 때문에 반도체를 이용한 장치로는 그 성능을 구현할 수 없다. 따라서 열음극을 사용하는 전자총을 기반으로 한 다양한 형태의 진공튜브 장치가 주로 이용되고 있다. 현재 고출력 마이크로파 진공튜브용 열음극 전자총은 대부분 외국에서 수입하고 있는데 그 이유는 전자총의 핵심 부품인 열음극 캐소드를 국내에서 개발하지 못하였기 때문이다. 하지만 본 연구에서는 텅스텐 기반의 함침형 열음극 캐소드를 국내에서 자체 개발하는데 성공하였다. 전통적으로 미국에서 개발해온 함침형 열음극 캐소드는 텅스텐 소결체에 기공을 학보하고 여기에 Ba을 중심으로 한 알칼리성 물질들을 일정비율로 혼합하여 함침한 것으로 일함수 2.1~2.3 eV 수준의 물성을 갖는다. 이에 따라 방출할 수 있는 전류의 양은 운용 온도 $1000^{\circ}C$ 정도에서 전류밀도로 대략 수 $A/cm^2$ 수준이다. 본 연구에서 개발한 캐소드는 S-type으로 알려진 것으로 BaO : CaO : $Al_2O_3$ = 4 : 1 : 1 비율로 함침되었다. 고진공장치에서 전류측정 결과 $1040^{\circ}C$에서 $10.6A/cm^2$의 전류밀도를 기록하였으며 이에 대하여 Richardson-Dushman equation으로 계산하였을 때, 약 1.9 eV의 일함수를 갖는 것을 알 수 있었다. 이는 현재 많은 응용분야에서 사용하고 있으며 함침형 캐소드에 Os이나 Ir 등의 물질을 코팅하여 일함수를 낮추고 전류밀도를 향상시킨 M-type 캐소드의 결과와 유사한 수준이다.

  • PDF