• Title/Summary/Keyword: thermal physiological response

Search Result 59, Processing Time 0.025 seconds

Layering Effects on Clothing Microclimate, Clothing Insulation and Physiological Responses

  • Park, Joonhee;Yoo, Shinjung
    • International Journal of Human Ecology
    • /
    • v.14 no.2
    • /
    • pp.93-103
    • /
    • 2013
  • This study investigated the relationship of clothing microclimate and physiological responses in order to examine the layering effects on the clothing microclimate as an index to predict clothing thermal insulation ($I_{cl}$). Experiments were conducted in a $15^{\circ}C$ environment on six physically active males. Increased clothing layers resulted in higher mean temperature inside the clothing ($\bar{T}_{cl}$) and $I_{cl}$. The $I_{cl}$ had a high correlation with: $\bar{T}_{cl}$ (r = 0.556), the difference between the innermost surface temperature and the outermost surface temperature at the chest (DST) (r = 0.549) and the temperature inside clothing at the abdomen (r = 0.478). $\bar{T}_{cl}$ had the highest correlation with the temperature inside clothing at the abdomen (r = 0.889). $\bar{T}_{cl}$ also had the highest correlation with $\bar{T}_{sk}$ (r = 0.860). The results showed that the relationship between $I_{cl}$ and $\bar{T}_{cl}$ was linear (p < .01). Thermal comfort had a negative correlation with $\bar{T}_{cl-thigh}$ (r=-0.411) and $\bar{T}_{cl}$ (r = -0.323) (p < .01.)

Research on the Thermal Comfort Heating Mode Considering Psychological and Physiological Response of Automobile Drivers (운전자의 심리·생리 반응을 고려한 승용차 쾌적 난방 모드에 관한 연구)

  • Kim, Min Soo;Kum, Jong Soo;Park, Jong Il;Kim, Dong Gyu
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.30 no.3
    • /
    • pp.149-157
    • /
    • 2018
  • In this research, the psychological and physiological reactions of the driver were measured during winter to evaluate thermal comfort. The experiment was conducted using 3 different cases which are hot air heating, warm-wire seat heating and hot air & warm-wire seat heater operating simultaneously. With regard to psychological reaction, the warm-wire heating mode was the most preferred. The reason is that it is dry in other cases. With regard to EEG response, thermal comfort increased by 37% in warm air mode heating. In addition, when the warm-wire heating mode and the hot air & warm-wire heating mode were simultaneously operated, the thermal comfort continuously increased by between 17% and 20% for 20 minutes after boarding. Under the change of the autonomic nervous system, the thermal stress level increased by 23% after 15 minutes on board in the hot air heating mode and decreased continuously by 13% during the warm-wire seat heating mode. We recommended the hot air heating mode is only used for a short time to raise the inside temperature during the early boarding period and that warm-wire seat heating mode be actively utilized.

Effects of Design and Material Change of Firefighter Station Uniform on Thermal Physiological and Subjective Responses (소방 기동복의 디자인과 소재 변화가 착용자의 온열생리 반응 및 주관적 감각에 미치는 영향)

  • Kim, Hee-Eun;Kim, Seong-Suk;Son, Su-Young
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.44 no.4
    • /
    • pp.776-787
    • /
    • 2020
  • This study investigated physiological and subjective responses to different types of firefighter station uniforms made with various designs and materials. Six healthy males participated in this study that consisted of 20 min of rest, 30 min of treadmill exercise, and 30 min of recovery in a hot and humid environment (34℃ and 65%RH). The experimental clothing conditions were as follows. 1) a fitted T-shirt and trouser made of 100% polyester (FC-Uniform), and 2) flame retardant T-shirts made of acrylic and cotton as well as trousers with aramid and polyester, designed for overfitting (Control). There were no significant differences in the body temperature, and sweat rate between the two conditions; however, the heart rate with the FC-Uniform was significantly lower than Control (p=.025). The clothing microclimate temperature at the chest of the FC-Uniform was significantly lower than the Control (p=.037), and a difference of 1℃ was maintained until the recovery was complete. There were no significant differences in the subjective responses; however, participants experienced a humidity sensation faster with FC-Uniform in the recovery phase. The results indicate that changes in the design and material of firefighter station uniforms may have a positive influence on reducing the thermal stress of firefighters.

Thermal Physiological Response of Functional Knitwears for Health and Comfort (건강 쾌적 니트의류가 온열생리반응에 미치는 영향)

  • Kang, Mi-Jung;Kwon, Young-Ah;Kim, Tae-Kyu
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.31 no.11
    • /
    • pp.1645-1652
    • /
    • 2007
  • The purpose of this study was to evaluate physiological response and subjective sensation of functional knitwears with different materials and designs. The three different types of knitwears were knitted(polar-neck with cotton/chitosan-C, V-neck with cotton/chitosan-CV and polar neck with cotton/chitosan/silver yarn-CS) and evaluated by four healthy female subjects. Eardrum temperature, mean skin temperature, clothing microclimate, and heart rate were measured in climatic chamber($30^{\circ}C$, 50%RH, 0.5m/sec). The results were as follows. 1. Eardrum temperature was generally evaluated as lower in CV and CS than in C. Mean skin temperature was lower in knitwears with silver yarn than in knitwears without silver yarn. 2. Clothing microclimate temperature on the chest was lower in knitwears with silver yarn than in knitwears without silver yarn. 3. Clothing microclimate humidity was generally lower knitwears with silver yarn than knitwears without silver yarn. 4. Heart rate was lower in knitwears with silver yarn than in knitwears without silver yarn and lower in V-neck than in polar neck. 5. Thermal sensation was slightly warmer in knitwears without silver yarn than in knitwears with silver yarn. Overall comfort sensation was evaluated as more comfortable in CV and CS than in C.

Thermal Pain and Thermal Stimulus (열통과 열자극)

  • Kwak, Je-Hi;Kwak, Young-Sae
    • The Korean Journal of Physiology
    • /
    • v.7 no.1
    • /
    • pp.49-51
    • /
    • 1973
  • Denuded nerve fibers containing the node of Ranvier were prepared from the nerve innervating the gastrocnemius muscle of the frog. The effects of temperature rise of the medium surrounding the naked nerve fibers were studied upon the muscle response. A rise in temperature of the order of $50^{\circ}{\sim}90^{\circ}C$ was proved ineffective in the production of contractions in the muscle. It is thus concluded that the widespread concept that heating is one of the nerve stimuli is inadequate, and that thermal pain is the indirect effect of thermal stimuli. The authors' standpoint about thermal stimulus is that thermal stimulus or heating is one thing, cooling is another.

  • PDF

Development of comfort algorism for Indoor temperature chagne in Heating System (변동환경 대응을 위한 난방System의 쾌적 알고리즘 개발)

  • Kim, Dong-Gyu;Jeong, Yong-Hyun;Kum, Jong-Soo
    • Journal of Fisheries and Marine Sciences Education
    • /
    • v.18 no.3
    • /
    • pp.229-235
    • /
    • 2006
  • This study investigated physiology and psychological response of subjects, when heat pump was operated long time within comfort temperature range. Eight subjects were participated for the experiment. Their age was from 22 to 25 years old. The results of this experiment will propose basic data for improving comfort control algorithm in fluctuating environment by using heat pump. When indoor temperature was controlled by heat pump, the conclusion was as follows. 1) When votes of subjects was considered, the thermal comfort neutrality or lower range helped formation of comfort sensation for subjects. 2) When room temperature was lower, thermal comforts of shoulder, knee and foot with subjects thermal comfort showed high correlation. And when room temperature was higher, thermal comfort of face region with subjects thermal comfort showed high correlation. 3) The necessity of temperature change after 50 minutes from initially operating heat pump demands the additional analysis against the physiological signal.

Growth and Physiological Responses of Quercus acutissima Seedling under Drought Stress

  • Lim, Hyemin;Kang, Jun Won;Lee, Solji;Lee, Hyunseok;Lee, Wi Young
    • Plant Breeding and Biotechnology
    • /
    • v.5 no.4
    • /
    • pp.363-370
    • /
    • 2017
  • In this study, Quercus acutissima seedlings were subjected to drought for 30 days then analyzed to determine their response to water deficit. The growth phenotype, chlorophyll fluorescence response, fresh weight, dry weight, photosynthetic pigment levels, soluble sugar content, and malondialdehyde (MDA) were measured to evaluate the effects of drought on plant growth and physiology. The growth phenotype was observed by infrared (IR) digital thermal imaging after 30 days of drought treatment. The maximum, average, and minimum temperatures of drought-treated plant leaves were $1-2^{\circ}C$ higher than those of the control. In contrast, the fresh and dry weights of the dehydrated leaves were generally lower than those of the control. There were no significant differences between treatments in terms of chlorophyll a, chlorophyll b, total chlorophyll, and carotenoid levels. Nevertheless, for the drought treatment, the $F_v/F_m$ and $F_v/F_o$ ratios (chlorophyll fluorescence response) were lower than those for the control. Therefore, photosynthetic activity was lower in the dehydrated plants than the control. The drought-stressed Q. acutissima S0536 had lower soluble sugar (glucose and fructose) and higher MDA levels than the controls. These findings may explain the early growth and physiological responses of Q. acutissima to dehydration and facilitate the selection of drought-resistant tree families.

Evaluation of Thermal Physiological Responses and Comfort in Dox Fabric (한지닥 섬유제품의 인체 생리 반응 및 쾌적성 평가)

  • Im, Soon
    • Journal of the Korean Society of Costume
    • /
    • v.63 no.5
    • /
    • pp.102-114
    • /
    • 2013
  • This study performed the evaluation of skin temperature, heart rate, humidity and temperature inside clothing, and subjective sensation to estimate the physiological responses of the human body and its feeling of comfort for developing value-added dox fabric. Experiments were performed on five healthy adult women whose average age was 21, at climate chamber in which temperature, relative humidity and air current were set up below $28{\pm}5^{\circ}C$, $50{\pm}10%$, 0.2m/s, respectively. Two kinds of clothes were used for the experiments: 100% cotton and dox clothes. The clothes were identical in size and form, and the attire consisted of long-sleeved shirts, long trousers, and socks. The experiment was performed for 30 minutes using ergometer. The results are as follows. 1) It showed low skin temperature of forearm, breast, back, forehead and lower leg in exercise, but high skin temperature of them in recovery. However skin temperature of thigh and foot increased from rest to recovery. 2) It showed significant difference (p<0.001, p<0.01) in average skin temperature between cotton and dox clothes. Cotton clothes had a higher average skin temperature compared to dox. Not only was there a significant difference in temperature inside clothing (p<0.001), this was also the case with humidity inside the clothing (p<0.001).

Diagnosis of Office Occupant's Adaptation Level for Thermal Environment (사무실 근무자의 온열환경에 대한 적응수준 진단)

  • Kim, Yang-Weon
    • Korean Journal of Human Ecology
    • /
    • v.12 no.5
    • /
    • pp.747-754
    • /
    • 2003
  • The actual clothing conditions were surveyed to diagnose clothing condition of Korean female in the view point of the adaptation to the thermal environment according to seasonal changes. Then, clothing microclimate, physiological responses, and subjective sensation were investigated through wearing trials on human body in climatic chamber based on the results from the survey. Factors to evaluate validity of clothing condition were clothing weight, clothing microclimate, physiological response of human body, and subjective sensation. The results were as follows: 1. Clothing weight per body surface area of the season was $856g/m^{2}$, $439g/m^{2}$ in summer, $630g/m^{2}$ in fall, and $1184g/m^{2}$ in winter. Cold - resistance of Korean female in office was superior to Japanese, inferior to residents of rural areas of Korea, and similar to male in office. However, in heat - resistance, female in office was inferior to residents of rural areas of Korea. 2. In spring, fall, winter, clothing microclimate temperature was a little higher than that in summer. Therefore, it was not a desirable wearing condition even though the clothing microclimate was comfortable zone. 3. Mean skin temperature of female in office was including within the range of Winslow's comfortable zone, but the range of comfortable zone in mean skin temperature of female was more narrow than Winslow's. Thus, it has problem for female to adaptation to thermal environment.

  • PDF

A Study on Behavior Pattern and Physiological Changes during Bathing and Showering (목욕 및 샤워시 행동패턴 및 생리적 변화에 대한 연구)

  • Jeong W.W.;Rhee K.;Park K.R.;Chun K.J.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2005.10a
    • /
    • pp.256-259
    • /
    • 2005
  • Analysis of behavior pattern and thermal response during bathing and showering provides important fundamental data when developing an automatic bathing/showering system. The behavior pattern and physiological changes during bathing/showering were measured und analyzed for the aged male group. We recorded the volunteers showering at front, back, left and right view using four CCTV cameras in order to study the behavior pattern during showering. The photographic data were analyzed by counting the frequencies of body contact and identifying zones where hands could reach. In order to study the thermal response, we measured the blood pressure (B.P), heart rate (H.R), body temperature (B.T.), breathing rate (B.R) for the different water temperatures and the locations of immersion for the young and old age groups. The results showed that the frequencies of body contacts were varied for different body sections. Also there were some body sections where hands could not be reached because of reduced pliability and muscular strength of the aged group. But we observed rather uniform body contact frequencies when a towel was used. In partial immersion bath experiments, we observed the changes of B.P. H.R and B.T in the case of young and old age groups, and the changes were more significant in the young age group.

  • PDF