• 제목/요약/키워드: thermal losses

검색결과 246건 처리시간 0.022초

Bottom Ash를 식생블록으로 활용하기 위한 배합비 연구 (A Research of Bottom Ash as a Lihgtweight Vegetation Block to Take Advantage of the Mixing Ratio)

  • 문종욱;오중근;이태구
    • KIEAE Journal
    • /
    • 제12권2호
    • /
    • pp.125-129
    • /
    • 2012
  • With the development of the industry, such as homes and industries of electric energy usage and thereby increase the supply of electrical energy for power generation facilities were also increased. Among them an increase in thermal power plants, such as Bottom Ash was accompanied by an increase in industrial waste. If fly ash is recycled, some ten thousand Fly Ash and Bottom Ash Landfill, the recycling rate is low in most. In this study, in order to resolve the problem of fly ash recycling Bottom Ash to take advantage of low physical and chemical characteristics were analyzed. Evaluation of Physical Properties of Bottom Ash In addition, through the evaluation of functional properties of additives chogyeol condensation of 1 hour or more, within 3 hours of closing, Flow has more than 190mm of wheel load resistance value is less than 3mm flooring developed to study the subsequent emphasis on the Properties is based. Through these studies by developing a functional flooring help with the problem of resource depletion, and losses due to reclamation and pollution is to prevent.

부산지역 대형병원 냉방장비의 용량설정 실태조사 (Survey Study of Optimal Cooling Equipment Capacity of the Large Hospitals in Busan City)

  • 이지원;진경일;김세환
    • KIEAE Journal
    • /
    • 제14권6호
    • /
    • pp.105-110
    • /
    • 2014
  • The basic factors determining the amount of energy used in hospital buildings are weather conditions and building factors. But the real energy consumer is central plant equipment such as boilers and chillers that produce thermal energy for heating and cooling. Inaccurate decision of the primary equipment's size can cause a high initial-cost, an excessive equipment space, a wasted energy by low operation-efficiency and shortening of the machine's life. In this reason, the decision of optimal size for central plant equipment is very important. There are several factors for the decision such as an operation factor, a factor (equipment factor), piping losses and a simultaneous usage factor applied in the sizing process except a basic cooling load. But there is no standard method for applying those factors. Usually, factors are applied individually by an experience or custom of each engineer. In this study, the authors emphasize the meaning and the problem of those factors, examine them by analyzing factors which were applied to actual practices, and propose the recommendation value of safety, load, operation factors and application methods.

패각 폐기물을 이용한 $H_2S$ 제거에 관한 연구(II) -고정층 반응기를 이용한 황화반응특성 (A Study on the H??S Removal with Utilization of Seashell Waste(II) - The Characteristics of Sulfided Reaction Using Fixed Bed Reactor-)

  • 김영식
    • 한국환경보건학회지
    • /
    • 제29권3호
    • /
    • pp.86-90
    • /
    • 2003
  • In this study, lots of methods have been studing to utilize energy and decrease contaminated effluents. There has been great progress on IGCC (Integrated gasification combined cycle) to reduce thermal energy losses. The following results have been conducted from desulfurization experiments using waste shell to remove H$_2$S. Fixed bed desulfurization experiments, to obtain basic data for scale-up was indicated. Oyster was the best among the various sorbents, like the results of TGA. Especially, H$_2$S removal efficiency of uncalcined oyster was the highest. When use oyster as desulfurization sorbents, calcination process was not needed. Thus, high desulfurization efficiency would be expected. Fixed bed reactor experiments were indicated particle size of sorbents. These had influenced on desulfurization capacity. As smaller particle size was found better desulfurization capacity. Large capacity difference was found between 0.613 mm and 0.335 mm. But, differences between 0.335 mm and 0.241 mm was relatively small. As bed temperature increased, H$_2$S removal capacity increased. Therefore, both particle size and bed temperature should be considered to remove H$_2$S by sorbents.

Analysis of Diesel Combustion Flames with Highly Oxygenated Fuels

  • Kim Bong-Seock;Ogawa Hideyuki
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제29권6호
    • /
    • pp.662-670
    • /
    • 2005
  • With highly oxygenated fuels the smoke emissions decreased sharply and linearly with increases in the fuel oxygen content and entirely disappeared at an oxygen content of $38wt-\%$ even at stoichiometric mixture conditions The NOx also decreased monotonically with increases in oxygen content. and thermal efficiency slightly improved because of a reduction in cooling loss and improvement in the degree of constant volume combustion. The mechanisms of the significant reductions in emissions and improvement in engine performance were analyzed with a bottom view type DI diesel engine. Together with direct flame images, flame images were taken through an optical fetter passing only two wavelengths for use in 2-D two-color analysis. The results showed that luminous flame decreased significantly with increases in oxygen content and was not detected for neat dimethoxy methane(DMM). The decrease in flame luminosity with highly oxygenated fuels corresponds with decreases in soot and cooling losses, including those due to heat radiation. The 2-D two-color flame analysis indicated that the high temperature flame and high KL factor areas apparently decreased with increasing fuel oxygen content. These results correspond strongly with decreases in NOx. smoke. and cooling loss with increases in oxygen content.

CH4/Air 예혼합화염의 하류영역에서 체류시간 및 열손실에 의한 NOx의 생성특성 (The Effect of Residence Time and Heat Loss on NOx Formation Characteristics in the Downstream Region of CH4/Air Premixed Flame)

  • 황철홍;현승호;탁영조;이창언
    • 대한기계학회논문집B
    • /
    • 제31권1호
    • /
    • pp.99-108
    • /
    • 2007
  • In this study, the NOx formation characteristics of one-dimensional $CH_4$/Air premixed flame using detailed-kinetic chemistry are examined numerically. The combustor length and the amount of heat loss are varied to investigate the effect of residence time and heat loss on the NOx formation in a post-flame region. In the flame region, NO is mainly produced by the Prompt NO mechanism including $N_2$O-intermediate NO mechanism over all equivalence ratios. However, thermal NO mechanism is more important than Prompt NO mechanism in the post-flame region. In the case of adiabatic condition, the increase of combustor length causes the remarkable increase of NO emission at the exit due to the increase of residence time. On the other hand, NO reaches the equilibrium state in the vicinity of flame region, considering radiation and conduction heat losses. Furthermore the NO, in the case of $\phi$=1.2, is gradually reduced in the downstream region as the heat loss is increased. From these results, it can be concluded that the controls of residence time and heat loss in a combustor should be recognized as an important NOx reduction technology.

An Experimental Study on the Characteristic of the Hot Water-Air Heating Generating System with a Solar Collector

  • Rokhman, Fatkhur;Hong, Boo-Pyo;You, Jin-Kwang;Yoon, Jung-In;Choi, Kwang-Hwan
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2012년도 춘계학술발표대회 논문집
    • /
    • pp.360-363
    • /
    • 2012
  • A solar air heating has low efficiency compared with the solar water heating because the heat capacity of the air is small. The heat received by solar collector plate is not fully transferred to the air and then a part of them became the losses to the environment through conduction and convection process. This research is focusing on a design of better combined multi-purposed system suggested by us and aims to secure the more efficient solar energy utilization by combining the hot water and air heating system. The result in this paper has shown that the proposed design has better thermal performance than that of the common design. Furthermore, it was found that the performance of the combined air - water heating system increases the efficiency from 30% to 35%-40%.

  • PDF

영광 3, 4호기 원자로 유동 모델 시험 (YGN 3 & 4 Reactor Flow Model Test)

  • Lee, Kye-Bock;Im, In-Young;Lee, Byung-Jin;Kuh, Jung-Eui
    • Nuclear Engineering and Technology
    • /
    • 제23권3호
    • /
    • pp.340-351
    • /
    • 1991
  • l/5.03 축소 원자로 모델을 이용하여 원자력 발전소 영광 3,4호기를 위한 유동시험을 수행하였다. 이 유동 시험의 목적은 ABB-CE사의 System 80과 영광 3,4호기 원자로 크기의 상대적인 차이로 인해 발생하는 원자로 용기내의 수력학적 영향을 평가하는 것이다. 유동 모델은 상사성 원리에 따라 설계하였다. 이 시험에서 얻은 결과는 노심 입구 유량 분포, 노심 출구 압력 분포, 원자로 입구 노즐에서부터 출구 노즐까지 유동로를 따른 부분 구간 및 전체 압력 손실이다. 이 데이터들은 노심의 열적 여유도 분석에 필요한 입력 자료 제공과 해석적 수력설계 방법의 검증에 이용하게 된다.

  • PDF

유출유동을 가진 정사각유로 내 열전달 향상을 위한 경사진 요철 최적설계 (Optimization of Angled Ribs for Heat Transfer Enhancement in a Square Channel with Bleed Flow)

  • 이현;김경민;이동현;조형희
    • 대한기계학회논문집B
    • /
    • 제32권4호
    • /
    • pp.300-306
    • /
    • 2008
  • In the present study, the second order response surface method (RSM) is carried out to get optimum thermal design for enhancing heat transfer in a square channel with bleed flow. The RSM is used as an optimization technique. To calculate the heat transfer, RNG k-epsilon model and enhanced wall function are used. To design optimum rib turbulators, two design variables such as attack angle of rib $({\alpha})$ and rib pitch-to-rib height ratio (p/e) are optimized. In these analyses, the channel inlet Reynolds number was fixed at 10,000 in both non-bleeding and bleeding cases. The response surfaces of two design variables are constructed in cases with and without bleed flow. As a result, the optimum (or highest) heat transfer values are almost the same in ranges of two cases with and without bleed flow. However, the friction losses in the case with bleed flow are lower than those without bleed flow.

배터리 에너지 저장장치용 고효율 2kW급 양방향 DC-DC 컨버터 설계 (Design of a 2kW Bidirectional Synchronous DC-DC Converter for Battery Energy Storage System)

  • 이태영;조병극;조영훈;홍찬욱;이한솔;조관열
    • 전력전자학회논문지
    • /
    • 제22권4호
    • /
    • pp.312-323
    • /
    • 2017
  • This paper introduces the bidirectional dc-dc converter design case study, which employs silicon-carbide (SiC) MOSFETs for battery energy storage system (BESS). This converter topology is selected as bidirectional synchronous buck converter, which is composed of a half bridge converter, an inductor, and a capacitor, where the converter has less conduction loss than that of a unidirectional buck and boost converter, and to improve the converter efficiency, both the power stage design and power conversion architecture are described in detail. The conduction and switching losses are compared among three different SiC devices in this paper. In addition, the thermal analysis using Maxwell software of each switching device supports the loss analyses, in which both the 2 kW prototype analyses and experimental results show very good agreement.

난용성 약물의 용출 증가 (제 3 보) -키틴 또는 키토산과의 혼합분쇄물로부터의 푸로세미드의 용출 증가- (Enhancement of Dissolution Properties of Poorly Soluble Drugs (III) -Dissolution Enhancement of Furosemide from Ground Mixtures with Chitin or Chitosan-)

  • 신상철;오인준;이강춘;이용복;고익배
    • Journal of Pharmaceutical Investigation
    • /
    • 제17권4호
    • /
    • pp.175-181
    • /
    • 1987
  • To increase the dissolution rate of furosemide, chitin and chitosan which are widely occurring biodegradable natural materials were used as drug carriers. The ground mixtures of furosemide with chitin or chitosan were prepared by grinding in a ball mill. The ground mixture showed a faster and more enhanced dissolution rate than the physical mixture or intact furosemide. The crystalline peaks of furosemide disappeared in the ground mixtures indicating the production of amorphous form. The comparison of infrared spectra of the physical mixture and the ground mixture showed an interaction such as association between the functional groups of furosemide and chitin or chitosan in the molecular level. The weight losses in TGA curves showed all the same patterns. However, the endothermic peak due to the fusion of furosemide in DTA curve disappeared in the ground mixture indicating the different thermal property. The dissolution of furosemide from ground mixtures was fast in the order of chitosan and then chitin. The co-grinding technique with chitin or chitosan provided a promising way enhancing the dissolution rate of practically insoluble drug.

  • PDF